Please check your email for the verification action. You may continue to use the site and you are now logged in, but you will not be able to return to the site in future until you confirm your email address.
Purpose: We report the 10 to 13 year results of the PFC knee system at our institution.
Method/Results: Between 1992 and 1995 97 PFC primary knee arthroplasties were performed consecutively in 82 patients. 32 patients have subsequently died (37 knees) and four (4 knees) are lost to follow-up. Clinical and radiological review of 46 patients (56 knees) was performed at a mean of 11.1 years post-operatively. Outcome was assessed using the Charnley modification of the Merle D’Aubigne score, with a median of 5 for pain and 4 for function. Radiological failure was defined as progressive radiolucency (1 case), lysis (1 case) or subsidence (1 case). Polyethylene wear was detectable in 10 cases, with >
50% in two. There was 100% survivorship with revision for aseptic loosening as an endpoint. There has been one revision for infection and one patella resurfacing, giving a 98% survivorship with no re-operation. In addition one periprosthetic fracture above a well fixed femoral component, required a supracondylar nail.
Conclusions: The PFC gives excellent outcome and survivorship at 13 years, regardless of the experience of the operating surgeon. This demonstrates that with careful training the PFC is a reliable knee replacement in the long-term for trainers and trainees alike.