Advertisement for orthosearch.org.uk
Results 1001 - 1020 of 1129
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 459 - 466
1 Apr 2013
Fisher WD Agnelli G George DJ Kakkar AK Lassen MR Mismetti P Mouret P Turpie AGG

There is currently limited information available on the benefits and risks of extended thromboprophylaxis after hip fracture surgery. SAVE-HIP3 was a randomised, double-blind study conducted to evaluate the efficacy and safety of extended thromboprophylaxis with the ultra-low molecular-weight heparin semuloparin compared with placebo in patients undergoing hip fracture surgery. After a seven- to ten-day open-label run-in phase with semuloparin (20 mg once daily subcutaneously, initiated post-operatively), patients were randomised to once-daily semuloparin (20 mg subcutaneously) or placebo for 19 to 23 additional days. The primary efficacy endpoint was a composite of any venous thromboembolism (VTE; any deep-vein thrombosis and non-fatal pulmonary embolism) or all-cause death until day 24 of the double-blind period. Safety parameters included major and clinically relevant non-major bleeding, laboratory data, and treatment-emergent adverse events (TEAEs). Extended thromboprophylaxis with semuloparin demonstrated a relative risk reduction of 79% in the rate of any VTE or all-cause death compared with placebo (3.9% vs 18.6%, respectively; odds ratio 0.18 (95% confidence interval 0.07 to 0.45), p < 0.001). Two patients in the semuloparin group and none in the placebo group experienced clinically relevant bleeding. TEAE rates were similar in both groups. In conclusion, the SAVE-HIP3 study results demonstrate that patients undergoing hip fracture surgery benefit from extended thromboprophylaxis.

Cite this article: Bone Joint J 2013;95-B:459–66.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 25 - 27
1 Feb 2013

The February 2013 Shoulder & Elbow Roundup360 looks at: whether we should replace fractured shoulders; the limited evidence for shoulder fractures; cuffs and early physio; matrix proteins and cuff tears; long-term SLAP tear outcomes; suture anchors; recurrent Bankart repairs; and acromial morphology and calcific tendonitis.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 27 - 30
1 Feb 2013

The February 2013 Spine Roundup360 looks at: complications with anterior decompression and fusion; lumbar claudication and peripheral vascular disease; increasing cervical instability in rheumatoids; kyphoplasty; cervical stenosis; exercise or fusion for chronic lower back pain; lumbar disc arthroplasty and adjacent level changes; and obese disc prolapses.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 30 - 32
1 Feb 2013

The February 2013 Trauma Roundup360 looks at: the risk of ankle fractures; absorbable implants; minimally invasive heel fracture fixation; pertrochanteric fractures; arthroplasty and intracapsular hip fractures; and extensor mechanism disruption.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1077 - 1085
1 Aug 2012
Yin Z Zhang J Kan S Wang X

Follow-up radiographs are usually used as the reference standard for the diagnosis of suspected scaphoid fractures. However, these are prone to errors in interpretation. We performed a meta-analysis of 30 clinical studies on the diagnosis of suspected scaphoid fractures, in which agreement data between any of follow-up radiographs, bone scintigraphy, magnetic resonance (MR) imaging, or CT could be obtained, and combined this with latent class analysis to infer the accuracy of these tests on the diagnosis of suspected scaphoid fractures in the absence of an established standard. The estimated sensitivity and specificity were respectively 91.1% and 99.8% for follow-up radiographs, 97.8% and 93.5% for bone scintigraphy, 97.7% and 99.8% for MRI, and 85.2% and 99.5% for CT. The results were generally robust in multiple sensitivity analyses. There was large between-study heterogeneity for the sensitivity of follow-up radiographs and CT, and imprecision about their sensitivity estimates.

If we acknowledge the lack of a reference standard for diagnosing suspected scaphoid fractures, MRI is the most accurate test; follow-up radiographs and CT may be less sensitive, and bone scintigraphy less specific.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 16 - 19
1 Feb 2013

The February 2013 Knee Roundup360 looks at: mobile-bearing TKRs; arthroscopic ACL reconstruction; the use of chondrocytes for osteochondral defects; ACL reconstruction and the return to pivoting sports; ACLs and the MOON study; the benefit of knee navigation; and trabecular metal.


Bone & Joint Research
Vol. 2, Issue 2 | Pages 33 - 40
1 Feb 2013
Palmer AJR Thomas GER Pollard TCB Rombach I Taylor A Arden N Beard DJ Andrade AJ Carr AJ Glyn-Jones S

Objectives

The number of surgical procedures performed each year to treat femoroacetabular impingement (FAI) continues to rise. Although there is evidence that surgery can improve symptoms in the short-term, there is no evidence that it slows the development of osteoarthritis (OA). We performed a feasibility study to determine whether patient and surgeon opinion was permissive for a Randomised Controlled Trial (RCT) comparing operative with non-operative treatment for FAI.

Methods

Surgeon opinion was obtained using validated questionnaires at a Specialist Hip Meeting (n = 61, 30 of whom stated that they routinely performed FAI surgery) and patient opinion was obtained from clinical patients with a new diagnosis of FAI (n = 31).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 58 - 60
1 Nov 2012
Munro JT Garbuz DS Masri BA Duncan CP

Tapered, fluted, modular, titanium stems have a long history in Europe and are increasing in popularity in North America. We have reviewed the results at our institution looking at stem survival and clinical outcomes. Radiological outcomes and quality of life assessments have been performed and compared to cylindrical non-modular cobalt chromium stems. Survival at five years was 94%. This fell to 85% at ten years due to stem breakage with older designs. Review of radiology showed maintenance or improvement of bone stock in 87% of cases. Outcome scores were superior in tapered stems despite worse pre-operative femoral deficiency. Tapered stems have proved to be a useful alternative in revision total hip arthroplasty across the spectrum of femoral bone deficiency.


Bone & Joint 360
Vol. 1, Issue 6 | Pages 10 - 12
1 Dec 2012

The December 2012 Hip & Pelvis Roundup360 looks at: swimming against the tide with resurfacing; hip impingement surgery; the relationship between obesity and co-morbidities and joint replacement infection; cemented hips; cross-linked polyethylene notching; whether cement is necessary in oncological arthroplasty; and how total hip replacement may result in weight gain.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 135 - 142
1 Jan 2013
Yeranosian M Horneff JG Baldwin K Hosalkar HS

Fractures of the femoral neck in children are rare, high-energy injuries with high complication rates. Their treatment has become more interventional but evidence of the efficacy of such measures is limited. We performed a systematic review of studies examining different types of treatment and their outcomes, including avascular necrosis (AVN), nonunion, coxa vara, premature physeal closure (PPC), and Ratliff’s clinical criteria. A total of 30 studies were included, comprising 935 patients. Operative treatment and open reduction were associated with higher rates of AVN. Delbet types I and II fractures were most likely to undergo open reduction and internal fixation. Coxa vara was reduced in the operative group, whereas nonunion and PPC were not related to surgical intervention. Nonunion and coxa vara were unaffected by the method of reduction. Capsular decompression had no effect on AVN. Although surgery allows a more anatomical union, it is uncertain whether operative treatment or the type of reduction affects the rate of AVN, nonunion or PPC, because more severe fractures were operated upon more frequently. A delay in treatment beyond 24 hours was associated with a higher incidence of AVN.

Cite this article: Bone Joint J 2013;95-B:135-41.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1121 - 1126
1 Aug 2013
Núñez-Pereira S Pellisé F Rodríguez-Pardo D Pigrau C Bagó J Villanueva C Cáceres E

This study evaluates the long-term survival of spinal implants after surgical site infection (SSI) and the risk factors associated with treatment failure.

A Kaplan-Meier survival analysis was carried out on 43 patients who had undergone a posterior spinal fusion with instrumentation between January 2006 and December 2008, and who consecutively developed an acute deep surgical site infection. All were appropriately treated by surgical debridement with a tailored antibiotic program based on culture results for a minimum of eight weeks.

A ‘terminal event’ or failure of treatment was defined as implant removal or death related to the SSI. The mean follow-up was 26 months (1.03 to 50.9). A total of ten patients (23.3%) had a terminal event. The rate of survival after the first debridement was 90.7% (95% confidence interval (CI) 82.95 to 98.24) at six months, 85.4% (95% CI 74.64 to 96.18) at one year, and 73.2% (95% CI 58.70 to 87.78) at two, three and four years. Four of nine patients required re-instrumentation after implant removal, and two of the four had a recurrent infection at the surgical site. There was one recurrence after implant removal without re-instrumentation.

Multivariate analysis revealed a significant risk of treatment failure in patients who developed sepsis (hazard ratio (HR) 12.5 (95% confidence interval (CI) 2.6 to 59.9); p < 0.001) or who had > three fused segments (HR 4.5 (95% CI 1.25 to 24.05); p = 0.03). Implant survival is seriously compromised even after properly treated surgical site infection, but progressively decreases over the first 24 months.

Cite this article: Bone Joint J 2013;95-B:1121–6.


Bone & Joint Research
Vol. 1, Issue 11 | Pages 310 - 314
1 Nov 2012
Griffin XL Achten J Parsons N Boardman F Griffiths F Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. The National Hip Fracture Audit currently provides a framework for service evaluation. This evaluation is based upon the assessment of process rather than assessment of patient-centred outcome and therefore it fails to provide meaningful data regarding the clinical effectiveness of treatments. This study aims to capture data from the cohort of patients who present with a fracture of the proximal femur at a single United Kingdom Major Trauma Centre. Patient-centred outcomes will be recorded and provide a baseline cohort within which to test the clinical effectiveness of experimental interventions.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 868 - 873
1 Jul 2013
Cho SK Lu Y Lee D

Dysphagia is a common complication of anterior surgery of the cervical spine. The incidence of post-operative dysphagia may be as high as 71% within the first two weeks after surgery, but gradually decreases during the following months. However, 12% to 14% of patients may have some persistent dysphagia one year after the procedure. It has been shown that female gender, advanced age, multilevel surgery, longer operating time and severe pre-operative neck pain may be risk factors. Although the aetiology remains unclear and is probably multifactorial, proposed causes include oesophageal retraction, prominence of the cervical plate and prevertebral swelling. Recently, pre-operative tracheal traction exercises and the use of retropharyngeal steroids have been proposed as methods of reducing post-operative dysphagia.

We performed a systematic review to assess the incidence, aetiology, risk factors, methods of assessment and management of dysphagia following anterior cervical spinal surgery.

Cite this article: Bone Joint J 2013;95-B:868–73.


Bone & Joint 360
Vol. 1, Issue 5 | Pages 17 - 19
1 Oct 2012

The October 2012 Wrist & Hand Roundup360 looks at: osteoarticular flaps to the PIPJ; prognosis after wrist arthroscopy; adipofascial flaps and post-traumatic adhesions; the torn TFCC alone; ulna-shortening osteotomy for ulnar impaction syndrome; Dupuytren’s disease; when a wrist sprain is not a sprain; and shrinking the torn intercarpal ligament.


Bone & Joint 360
Vol. 1, Issue 5 | Pages 19 - 21
1 Oct 2012

The October 2012 Shoulder & Elbow Roundup360 looks at: fast-absorbing suture anchors for use in shoulder labral tears; double-row rotator cuff repair; degenerate massive rotator cuff tears addressed with partial repair; open and arthroscopic stabilisation of Bankart lesions; predicting the risk of revision humeral head replacement; arthroscopic treatment for frozen shoulder; and long-term follow-up of the Bristow-Latarjet procedure.


Bone & Joint Research
Vol. 1, Issue 6 | Pages 118 - 124
1 Jun 2012
Grawe B Le T Williamson S Archdeacon A Zardiackas L

Objectives

We aimed to further evaluate the biomechanical characteristics of two locking screws versus three standard bicortical screws in synthetic models of normal and osteoporotic bone.

Methods

Synthetic tubular bone models representing normal bone density and osteoporotic bone density were used. Artificial fracture gaps of 1 cm were created in each specimen before fixation with one of two constructs: 1) two locking screws using a five-hole locking compression plate (LCP) plate; or 2) three non-locking screws with a seven-hole LCP plate across each side of the fracture gap. The stiffness, maximum displacement, mode of failure and number of cycles to failure were recorded under progressive cyclic torsional and eccentric axial loading.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1511 - 1516
1 Nov 2012
Chang CB Cho W

In a prospective multicentre study we investigated variations in pain management used by knee arthroplasty surgeons in order to compare the differences in pain levels among patients undergoing total knee replacements (TKR), and to compare the effectiveness of pain management protocols. The protocols, peri-operative levels of pain and patient satisfaction were investigated in 424 patients who underwent TKR in 14 hospitals. The protocols were highly variable and peri-operative pain levels varied substantially, particularly during the first two post-operative days. Differences in levels of pain were greatest during the night after TKR, when visual analogue scores ranged from 16.9 to 94.3 points.

Of the methods of managing pain, the combined use of peri-articular infiltration and nerve blocks provided better pain relief than other methods during the first two post-operative days. Patients managed with peri-articular injection plus nerve block, and epidural analgesia were more likely to have higher satisfaction at two weeks after TKR. This study highlights the need to establish a consistent pain management strategy after TKR.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 43 - 50
1 Jan 2012
Khan RJK Maor D Hofmann M Haebich S

We undertook a randomised controlled trial to compare the piriformis-sparing approach with the standard posterior approach used for total hip replacement (THR). We recruited 100 patients awaiting THR and randomly allocated them to either the piriformis-sparing approach or the standard posterior approach. Pre- and post-operative care programmes and rehabilitation regimes were identical for both groups. Observers were blinded to the allocation throughout; patients were blinded until the two-week assessment. Follow-up was at six weeks, three months, one year and two years. In all 11 patients died or were lost to follow-up.

There was no significant difference between groups for any of the functional outcomes. However, for patients in the piriformis-sparing group there was a trend towards a better six-minute walk test at two weeks and greater patient satisfaction at six weeks. The acetabular components were less anteverted (p = 0.005) and had a lower mean inclination angle (p = 0.02) in the piriformis-sparing group. However, in both groups the mean component positions were within Lewinnek’s safe zone. Surgeons perceived the piriformis-sparing approach to be significantly more difficult than the standard approach (p = 0.03), particularly in obese patients.

In conclusion, performing THR through a shorter incision involving sparing piriformis is more difficult and only provides short-term benefits compared with the standard posterior approach.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1429 - 1434
1 Oct 2010
Mehin R Burnett RS Brasher PMA

A new generation of knee prostheses has been introduced with the intention of improving post-operative knee flexion. In order to evaluate whether this goal has been achieved we performed a systematic review and meta-analysis. Systematic literature searches were conducted on MEDLINE and EMBASE from their inception to December 2007, and proceedings of scientific meetings were also searched. Only randomised, clinical trials were included in the meta-analysis. The mean difference in the maximum post-operative flexion between the ‘high-flex’ and conventional types of prosthesis was defined as the primary outcome measure. A total of five relevant articles was identified.

Analysis of these trials suggested that no clinically relevant or statistically significant improvement was obtained in flexion with the ‘high-flex’ prostheses. The weighted mean difference was 2.1° (95% confidence interval −0.2 to +4.3; p = 0.07).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1305 - 1312
1 Oct 2012
Adams J Ryall C Pandyan A Metcalf C Stokes M Bradley S Warwick DJ

We systematically reviewed all the evidence published in the English language on proximal interphalangeal joint (PIPJ) replacement, to determine its effectiveness on the function of the hand and the associated post-operative complications.

Original studies were selected if they reported clinical outcome with a minimum of one year’s follow-up. Quality was assessed using the Cowley systematic review criteria modified for finger-joint replacements. Of 319 articles identified, only five were adequately reported according to our quality criteria; there were no randomised controlled trials. PIPJ replacements had a substantial effect size on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1) and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach was most successful. Post-operative loosening occurred in 10% (95% CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon replacements. Post-operative complications occurred in 27.8% (95% CI 20 to 37).

We conclude that the effectiveness of PIPJ replacement has not been established. Small observational case studies and short-term follow-up, together with insufficient reporting of patient data, functional outcomes and complications, limit the value of current evidence.

We recommend that a defined core set of patients, surgical and outcome data for this intervention be routinely and systematically collected within the framework of a joint registry.