Abstract
Introduction
The purpose of this study was to use patient generated digital surveillance PROM's to track outcomes of TKA, Medial PKA, Lateral PKA.
Methods
From Aug 2018 until June 2019 we performed 873 knee arthroplasties. Of these, 41 were fixed bearing lateral partial knee replacements (5%), 309 medial partial knee replacements (35%), and 523 total knee replacements (60%). The average age was 65 years old and 59% were female. KOOS-Jr scores were recorded preoperatively, and 6, 12 months postoperatively using digital surveillance technology with a greater than 90% response rate.
Results
Baseline, 6 month, and 12 month KOOS-JR scores for TKR (54, 76, 79) were not different than baseline, 6 month, and 12 month KOOS-JR scores for medial PKA (56, 78, 82) [p values of 0.23, 0.32, 0.20 respectively]. Baseline and 6 month KOOS-JR scores for TKR were not different than baseline and 6 month KOOS-JR scores for lateral PKA (55, 77) [p values of 0.35 and 0.50 respectively). Where as, the 12 month KOOS-JR scores for TKR (79) were significantly less than 12 month KOOS-JR scores for lateral PKA (84)[p value of 0.04]. Baseline, 6 month, and 12 month KOOS-JR scores for medial PKR were not different than lateral PKR (55, 77, 84) [p values of 0.49, 0.39, 0.20].
Conclusions
Prospective digital surveillance of PROM following knee arthroplasty has proven to be a cost-effective strategy. Short term improvements in PROM's following TKA and medial PKA were not different. Lateral PKA demonstrated statistically significant higher 1 year PROM but unlikely clinically significant. Longer-term follow-up is needed for determination of implant and unreplaced compartment survivorship.
For figures, tables, or references, please contact authors directly.