Abstract
Abstract
INTRODUCTION
With increasing use of fluoroscopy in Orthopaedic theatres in recent years, the occupational radiation exposure to the surgeons and the theatre staff has increased significantly. Thyroid is one of the most radio-sensitive tissues in the body, but there is a clear lack of awareness among theatre staff of risks of radiation to thyroid.
METHODS
We prospectively reviewed the use of thyroid shield by the theatre staff in the orthopaedic theatre for two weeks period. We also recorded the number of fluoroscopic images taken and total radiation dosage for each case.
RESULTS
Our results showed that of 249 staff in the theatres of which, only 35 people (14.2%) wore thyroid shields during fluoroscopy, whereas 100% were complaint with body protection shield. We noticed that only 30% of the surgeons, 40% of the scrub nurses and 5% anaesthetist use this, while 95% of the radiographers uses thyroid protection in theatre. Average total radiation during upper-limb procedures was 1.25 cGy, during lower-limb procedures it was 43.48 cGy. Total radiations were very high particularly during lower-limb nailing procedures (80.98 cGy).
CONCLUSION
Extensive use of fluoroscopy has a stochastic effect (accumulative effect) on thyroid gland particularly, if the dose in higher than 65 cGy. Despite its availability, only 14% people use the thyroid protection shield. We must emphasise the use of thyroid protection shield to the Orthopaedic surgeons, particularly during lower-limb procedures.