Knee

SURVIVAL OF CEMENT-LINKED CUSTOM IMPLANTS AND THEIR MEDIUM-TERM OUTCOMES SUPPORT THEIR USE IN COMPLEX AND SALVAGE ARTHROPLASTY

The British Association for Surgery of the Knee (BASK) May 2023 Meeting, London, England, 16–17 May 2023.



Abstract

Abstract

Introduction

Patients presenting with loosening or a fracture between ipsilateral hip and knee replacements provide a unique reconstructive challenge. We present mid-term results of the cement-over megaprosthesis (COM) when managing these complex cases. A COM is cement-linked to the stem of a well-fixed existing implant. We report the largest series to date and show that this may be preferable to total femoral replacement in a cohort of patients who often have significant co-morbidities.

Methodology

A retrospective analysis of patients undergoing COM between 2002–2022 was performed. Primary outcomes were defined as implant survival, displayed with survival analysis. Secondary outcomes included mortality and surgical complications. Functional outcomes included Visual Analogue Score (VAS), EuroQol-5D-3L and Musculoskeletal Tumour Society (MSTS) score at one year post operatively.

Results

34 patients underwent reconstructive cement-over technique. There were 20 custom distal femur replacements and 10 custom proximal femoral replacements. Two patients were revised, with a ten year implant survival of 94%. Fifteen patients died during the study period with an mean time to death of 66 months (25–109). The mean follow up was 75 months. 11 patients (32%) developed surgical complications. Mean VAS score was 4.9 (1–10), EuroQol-5D-3L index 0.45 (−0.59 – 0.88) and MSTS score was 16.8 (2–27) in 29 patients.

Conclusion

The COM technique provides good implant survivorship in complex cases with compromised bone stock and this series confirms this as an established alternative to total femoral replacement in these cases.