Abstract

Limited literature exists providing comprehensive assessment of complications following opening wedge high tibial osteotomy (OWHTO). We performed a retrospective study of local patients who underwent OWHTO for isolated medial compartment knee osteoarthritis from 1997–2013.

One hundred and fifteen patients met inclusion criteria. Mean follow-up = 8.4years. Mean age = 47 (range 32–62). Mean BMI = 29.1 (range 20.3–40.2). Implants used included Tomofix (72%), Puddu plate (21%) and Orthofix (7%) (no significant differences in age/ sex/ BMI). Wedge defects were filled with autologous graft (30%), Chronos (35%) or left empty (35%).

Five year survival rate (conversion to arthroplasty) = 80%. Overall complication rate = 31%. 25% of patients suffered 36 complications including minor wound infections (9.6%), major wound infections (3.5%), metalwork irritation necessitating plate removal (7%), non-union requiring revision (4.3%), vascular injury (1.7%), compartment syndrome (0.9%), and other minor complications (4%). No thromboembolic complications were observed.

A higher BMI (mean 34.2) was apparent in those patients suffering complications than those not (mean 26.9). No significant differences existed in complication rates relative to implant type, type of bone graft used or patient age at surgery.

Complications following OWHTO appear higher than previously reported in the literature; serious complications appear rare.