Advertisement for orthosearch.org.uk
Results 1 - 20 of 881
Results per page:
Bone & Joint Open
Vol. 4, Issue 9 | Pages 659 - 667
1 Sep 2023
Nasser AAHH Osman K Chauhan GS Prakash R Handford C Nandra RS Mahmood A

Aims. Periprosthetic fractures (PPFs) following hip arthroplasty are complex injuries. This study evaluates patient demographic characteristics, management, outcomes, and risk factors associated with PPF subtypes over a decade. Methods. Using a multicentre collaborative study design, independent of registry data, we identified adults from 29 centres with PPFs around the hip between January 2010 and December 2019. Radiographs were assessed for the Unified Classification System (UCS) grade. Patient and injury characteristics, management, and outcomes were compared between UCS grades. A multinomial logistic regression was performed to estimate relative risk ratios (RRR) of variables on UCS grade


Bone & Joint Open
Vol. 4, Issue 8 | Pages 612 - 620
21 Aug 2023
Martin J Johnson NA Shepherd J Dias J

Aims. There is ambiguity surrounding the degree of scaphoid union required to safely allow mobilization following scaphoid waist fracture. Premature mobilization could lead to refracture, but late mobilization may cause stiffness and delay return to normal function. This study aims to explore the risk of refracture at different stages of scaphoid waist fracture union in three common fracture patterns, using a novel finite element method. Methods. The most common anatomical variant of the scaphoid was modelled from a CT scan of a healthy hand and wrist using 3D Slicer freeware. This model was uploaded into COMSOL Multiphysics software to enable the application of physiological enhancements. Three common waist fracture patterns were produced following the Russe classification. Each fracture had differing stages of healing, ranging from 10% to 90% partial union, with increments of 10% union assessed. A physiological force of 100 N acting on the distal pole was applied, with the risk of refracture assessed using the Von Mises stress. Results. Overall, 90% to 30% fracture unions demonstrated a small, gradual increase in the Von Mises stress of all fracture patterns (16.0 MPa to 240.5 MPa). All fracture patterns showed a greater increase in Von Mises stress from 30% to 10% partial union (680.8 MPa to 6,288.6 MPa). Conclusion. Previous studies have suggested 25%, 50%, and 75% partial union as sufficient for resuming hand and wrist mobilization. This study shows that 30% union is sufficient to return to normal hand and wrist function in all three fracture patterns. Both 50% and 75% union are unnecessary and increase the risk of post-fracture stiffness. This study has also demonstrated the feasibility of finite element analysis (FEA) in scaphoid waist fracture research. FEA is a sustainable method which does not require the use of finite scaphoid cadavers, hence increasing accessibility into future scaphoid waist fracture-related research. Cite this article: Bone Jt Open 2023;4(8):612–620


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 795 - 800
1 Jul 2023
Parsons N Achten J Costa ML

Aims. To report the outcomes of patients with a fracture of the distal tibia who were treated with intramedullary nail versus locking plate in the five years after participating in the Fixation of Distal Tibia fracture (FixDT) trial. Methods. The FixDT trial reported the results for 321 patients randomized to nail or locking plate fixation in the first 12 months after their injury. In this follow-up study, we report the results of 170 of the original participants who agreed to be followed up until five years. Participants reported their Disability Rating Index (DRI) and health-related quality of life (EuroQol five-dimension three-level questionnaire) annually by self-reported questionnaire. Further surgical interventions related to the fracture were also recorded. Results. There was no evidence of a difference in patient-reported disability, health-related quality of life, or the need for further surgery between participants treated with either type of fixation at five years. Considering the combined results for all participants, there was no significant change in DRI scores after the first 12 months of follow-up (difference between 12 and 24 months, 3.3 (95% confidence interval -1.8 to 8.5); p = 0.203), with patients reporting around 20% disability at five years. Conclusion. This study shows that the moderate levels of disability and reduced quality of life reported by participants 12 months after a fracture of the distal tibia persist in the medium term, with little evidence of improvement after the first year. Cite this article: Bone Joint J 2023;105-B(7):795–800


Bone & Joint Open
Vol. 4, Issue 10 | Pages 728 - 734
1 Oct 2023
Fokkema CB Janssen L Roumen RMH van Dijk WA

Aims. In the Netherlands, general practitioners (GPs) can request radiographs. After a radiologically diagnosed fracture, patients are immediately referred to the emergency department (ED). Since 2020, the Máxima Medical Centre has implemented a new care pathway for minor trauma patients, referring them immediately to the traumatology outpatient clinic (OC) instead of the ED. We investigated whether this altered care pathway leads to a reduction in healthcare consumption and concomitant costs. Methods. In this retrospective cohort study, patients were included if a radiologist diagnosed a fracture on a radiograph requested by the GP from August to October 2019 (control group) or August to October 2020 (research group), on weekdays between 8.30 am and 4.00 pm. The study compared various outcomes between groups, including the length of the initial hospital visit, frequency of hospital visits and medical procedures, extent of imaging, and healthcare expenses. Results. A total of 634 patients were included. The results show a median reduction of 25 minutes in duration of initial hospital visits, one fewer hospital visit, overall fewer medical procedures, and a decrease in healthcare costs of €303.40 per patient in the research group compared to the control group. No difference was found in the amount of imaging. Conclusion. The implementation of the new care pathway has resulted in a substantial reduction in healthcare use and costs. Moreover, the pathway provides advantages for patients and helps prevent crowding at the ED. Hence, we recommend immediately referring all minor trauma patients to the traumatology OC instead of the ED. Cite this article: Bone Jt Open 2023;4(10):728–734


Bone & Joint Research
Vol. 13, Issue 11 | Pages 647 - 658
12 Nov 2024
Li K Zhang Q

Aims. The incidence of limb fractures in patients living with HIV (PLWH) is increasing. However, due to their immunodeficiency status, the operation and rehabilitation of these patients present unique challenges. Currently, it is urgent to establish a standardized perioperative rehabilitation plan based on the concept of enhanced recovery after surgery (ERAS). This study aimed to validate the effectiveness of ERAS in the perioperative period of PLWH with limb fractures. Methods. A total of 120 PLWH with limb fractures, between January 2015 and December 2023, were included in this study. We established a multidisciplinary team to design and implement a standardized ERAS protocol. The demographic, surgical, clinical, and follow-up information of the patients were collected and analyzed retrospectively. Results. Compared with the control group, the ERAS group had a shorter operating time, hospital stay, preoperative waiting time, postoperative discharge time, less intraoperative blood loss, and higher albumin and haemoglobin on the first postoperative day. The time to removal of the urinary catheter/drainage tube was shortened, and the drainage volume was also significantly reduced in the ERAS group. There was no significant difference in the visual analogue scale (VAS) scores on postoperative return to the ward, but the ERAS group had lower scores on the first, second, and third postoperative days. There were no significant differences in the incidence of complications, other than 10% more nausea and vomiting in the control group. The limb function scores at one-year follow-up were similar between the two groups, but time to radiological fracture union and time to return to physical work and sports were significantly reduced in the ERAS group. Conclusion. The implementation of a series of perioperative nursing measures based on the concept of ERAS in PLWH with limb fracture can significantly reduce the operating time and intraoperative blood loss, reduce the occurrence of postoperative pain and complications, and accelerate the improvement of the functional status of the affected limb in the early stage, which is worthy of applying in more medical institutions. Cite this article: Bone Joint Res 2024;13(11):647–658


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1369 - 1371
1 Dec 2024
Tabu I Ivers R Costa ML

In the UK, multidisciplinary teamwork for patients with hip fracture has been shown to reduce mortality and improves health-related quality of life for patients, while also reducing hospital bed days and associated healthcare costs. However, despite rapidly increasing numbers of fragility fractures, multidisciplinary shared care is rare in low- and middle-income countries around the world. The HIPCARE trial will test the introduction of multidisciplinary care pathways in five low- and middle-income countries in South and Southeast Asia, with the aim to improve patients’ quality of life and reduce healthcare costs. Cite this article: Bone Joint J 2024;106-B(12):1369–1371


Bone & Joint Open
Vol. 3, Issue 7 | Pages 566 - 572
18 Jul 2022
Oliver WM Molyneux SG White TO Clement ND Duckworth AD

Aims. The primary aim was to estimate the cost-effectiveness of routine operative fixation for all patients with humeral shaft fractures. The secondary aim was to estimate the health economic implications of using a Radiographic Union Score for HUmeral fractures (RUSHU) of < 8 to facilitate selective fixation for patients at risk of nonunion. Methods. From 2008 to 2017, 215 patients (mean age 57 yrs (17 to 18), 61% female (n = 130/215)) with a nonoperatively managed humeral diaphyseal fracture were retrospectively identified. Union was achieved in 77% (n = 165/215) after initial nonoperative management, with 23% (n = 50/215) uniting after surgery for nonunion. The EuroQol five-dimension three-level health index (EQ-5D-3L) was obtained via postal survey. Multiple regression was used to determine the independent influence of patient, injury, and management factors upon the EQ-5D-3L. An incremental cost-effectiveness ratio (ICER) of < £20,000 per quality-adjusted life-year (QALY) gained was considered cost-effective. Results. At a mean of 5.4 yrs (1.2 to 11.0), the mean EQ-5D-3L was 0.736 (95% confidence interval (CI) 0.697 to 0.775). Adjusted analysis demonstrated the EQ-5D-3L was inferior among patients who united after nonunion surgery (β = 0.103; p = 0.032). Offering routine fixation to all patients to reduce the rate of nonunion would be associated with increased treatment costs of £1,542/patient, but would confer a potential EQ-5D-3L benefit of 0.120/patient over the study period. The ICER of routine fixation was £12,850/QALY gained. Selective fixation based on a RUSHU < 8 at six weeks post-injury would be associated with reduced treatment costs (£415/patient), and would confer a potential EQ-5D-3L benefit of 0.335 per ‘at-risk patient’. Conclusion. Routine fixation for patients with humeral shaft fractures to reduce the rate of nonunion observed after nonoperative management appears to be a cost-effective intervention at five years post-injury. Selective fixation for patients at risk of nonunion based on their RUSHU may confer even greater cost-effectiveness, given the potential savings and improvement in health-related quality of life. Cite this article: Bone Jt Open 2022;3(7):566–572


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 858 - 864
1 Aug 2024
Costa ML Achten J Knight R Campolier M Massa MS

Aims. The aims of this study were to report the outcomes of patients with a complex fracture of the lower limb in the five years after they took part in the Wound Healing in Surgery for Trauma (WHIST) trial. Methods. The WHIST trial compared negative pressure wound therapy (NPWT) dressings with standard dressings applied at the end of the first operation for patients undergoing internal fixation of a complex fracture of the lower limb. Complex fractures included periarticular fractures and open fractures when the wound could be closed primarily at the end of the first debridement. A total of 1,548 patients aged ≥ 16 years completed the initial follow-up, six months after injury. In this study we report the pre-planned analysis of outcome data up to five years. Patients reported their Disability Rating Index (DRI) (0 to 100, in which 100 = total disability), and health-related quality of life, chronic pain scores and neuropathic pain scores annually, using a self-reported questionnaire. Complications, including further surgery related to the fracture, were also recorded. Results. A total of 1,015 of the original patients (66%) provided at least one set of outcome data during the five years of follow-up. There was no evidence of a difference in patient-reported disability between the two groups at five years (NPWT group mean DRI 30.0 (SD 26.5), standard dressing group mean DRI 31.5 (SD 28.8), adjusted difference -0.86 (95% CI -4.14 to 2.40; p = 0.609). There was also no evidence of a difference in the complication rates at this time. Conclusion. We found no evidence of a difference in disability ratings between NPWT compared with standard wound dressings in the five years following the surgical treatment of a complex fracture of the lower limb. Patients in both groups reported high levels of persistent disability and reduced quality of life, with little evidence of improvement during this time. Cite this article: Bone Joint J 2024;106-B(8):858–864


Bone & Joint Open
Vol. 3, Issue 3 | Pages 236 - 244
14 Mar 2022
Oliver WM Molyneux SG White TO Clement ND Duckworth AD

Aims. The primary aim of this study was to determine the rates of return to work (RTW) and sport (RTS) following a humeral shaft fracture. The secondary aim was to identify factors independently associated with failure to RTW or RTS. Methods. From 2008 to 2017, all patients with a humeral diaphyseal fracture were retrospectively identified. Patient demographics and injury characteristics were recorded. Details of pre-injury employment, sporting participation, and levels of return post-injury were obtained via postal questionnaire. The University of California, Los Angeles (UCLA) Activity Scale was used to quantify physical activity among active patients. Regression was used to determine factors independently associated with failure to RTW or RTS. Results. The Work Group comprised 177 patients in employment prior to injury (mean age 47 years (17 to 78); 51% female (n = 90)). Mean follow-up was 5.8 years (1.3 to 11). Overall, 85% (n = 151) returned to work at a mean of 14 weeks post-injury (0 to 104), but only 60% (n = 106) returned full-time to their previous employment. Proximal-third fractures (adjusted odds ratio (aOR) 4.0 (95% confidence interval (CI) 1.2 to 14.2); p = 0.029) were independently associated with failure to RTW. The Sport Group comprised 182 patients involved in sport prior to injury (mean age 52 years (18 to 85); 57% female (n = 104)). Mean follow-up was 5.4 years (1.3 to 11). The mean UCLA score reduced from 6.9 (95% CI 6.6 to 7.2) before injury to 6.1 (95% CI 5.8 to 6.4) post-injury (p < 0.001). There were 89% (n = 162) who returned to sport: 8% (n = 14) within three months, 34% (n = 62) within six months, and 70% (n = 127) within one year. Age ≥ 60 years was independently associated with failure to RTS (aOR 3.0 (95% CI 1.1 to 8.2); p = 0.036). No other factors were independently associated with failure to RTW or RTS. Conclusion. Most patients successfully return to work and sport following a humeral shaft fracture, albeit at a lower level of physical activity. Patients aged ≥ 60 yrs and those with proximal-third diaphyseal fractures are at increased risk of failing to return to activity. Cite this article: Bone Jt Open 2022;3(3):236–244


Bone & Joint Research
Vol. 12, Issue 5 | Pages 331 - 338
16 May 2023
Szymski D Walter N Krull P Melsheimer O Grimberg A Alt V Steinbrueck A Rupp M

Aims. The aim of this investigation was to compare risk of infection in both cemented and uncemented hemiarthroplasty (HA) as well as in total hip arthroplasty (THA) following femoral neck fracture. Methods. Data collection was performed using the German Arthroplasty Registry (EPRD). In HA and THA following femoral neck fracture, fixation method was divided into cemented and uncemented prostheses and paired according to age, sex, BMI, and the Elixhauser Comorbidity Index using Mahalanobis distance matching. Results. Overall in 13,612 cases of intracapsular femoral neck fracture, 9,110 (66.9%) HAs and 4,502 (33.1%) THAs were analyzed. Infection rate in HA was significantly reduced in cases with use of antibiotic-loaded cement compared with uncemented fixated prosthesis (p = 0.013). In patients with THA no statistical difference between cemented and uncemented prosthesis was registered, however after one year 2.4% of infections were detected in uncemented and 2.1% in cemented THA. In the subpopulation of HA after one year, 1.9% of infections were registered in cemented and 2.8% in uncemented HA. BMI (p = 0.001) and Elixhauser Comorbidity Index (p < 0.003) were identified as risk factors of periprosthetic joint infection (PJI), while in THA cemented prosthesis also demonstrated an increased risk within the first 30 days (hazard ratio (HR) = 2.73; p = 0.010). Conclusion. The rate of infection after intracapsular femoral neck fracture was statistically significantly reduced in patients treated by antibiotic-loaded cemented HA. Particularly for patients with multiple risk factors for the development of a PJI, the usage of antibiotic-loaded bone cement seems to be a reasonable procedure for prevention of infection. Cite this article: Bone Joint Res 2023;12(5):331–338


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 623 - 630
1 Jun 2024
Perry DC Dritsaki M Achten J Appelbe D Knight R Widnall J Roland D Messahel S Costa ML Mason J

Aims. The aim of this trial was to assess the cost-effectiveness of a soft bandage and immediate discharge, compared with rigid immobilization, in children aged four to 15 years with a torus fracture of the distal radius. Methods. A within-trial economic evaluation was conducted from the UK NHS and personal social services (PSS) perspective, as well as a broader societal point of view. Health resources and quality of life (the youth version of the EuroQol five-dimension questionnaire (EQ-5D-Y)) data were collected, as part of the Forearm Recovery in Children Evaluation (FORCE) multicentre randomized controlled trial over a six-week period, using trial case report forms and patient-completed questionnaires. Costs and health gains (quality-adjusted life years (QALYs)) were estimated for the two trial treatment groups. Regression was used to estimate the probability of the new treatment being cost-effective at a range of ‘willingness-to-pay’ thresholds, which reflect a range of costs per QALY at which governments are typically prepared to reimburse for treatment. Results. The offer of a soft bandage significantly reduced cost per patient (saving £12.55 (95% confidence interval (CI) -£5.30 to £19.80)) while QALYs were similar (QALY difference between groups: 0.0013 (95% CI -0.0004 to 0.003)). The high probability (95%) that offering a bandage is a cost-effective option was consistent when examining the data in a range of sensitivity analyses. Conclusion. In addition to the known clinical equivalence, this study found that the offer of a bandage reduced cost compared with rigid immobilization among children with a torus fracture of the distal radius. While the cost saving was small for each patient, the high frequency of these injuries indicates a significant saving across the healthcare system. Cite this article: Bone Joint J 2024;106-B(6):623–630


Bone & Joint Open
Vol. 5, Issue 10 | Pages 920 - 928
21 Oct 2024
Bell KR Oliver WM White TO Molyneux SG Graham C Clement ND Duckworth AD

Aims. The primary aim of this study is to quantify and compare outcomes following a dorsally displaced fracture of the distal radius in elderly patients (aged ≥ 65 years) who are managed conservatively versus with surgical fixation (open reduction and internal fixation). Secondary aims are to assess and compare upper limb-specific function, health-related quality of life, wrist pain, complications, grip strength, range of motion, radiological parameters, healthcare resource use, and cost-effectiveness between the groups. Methods. A prospectively registered (ISRCTN95922938) randomized parallel group trial will be conducted. Elderly patients meeting the inclusion criteria with a dorsally displaced distal radius facture will be randomized (1:1 ratio) to either conservative management (cast without further manipulation) or surgery. Patients will be assessed at six, 12, 26 weeks, and 52 weeks post intervention. The primary outcome measure and endpoint will be the Patient-Rated Wrist Evaluation (PRWE) at 52 weeks. In addition, the abbreviated version of the Disabilities of Arm, Shoulder and Hand questionnaire (QuickDASH), EuroQol five-dimension questionnaire, pain score (visual analogue scale 1 to 10), complications, grip strength (dynamometer), range of motion (goniometer), and radiological assessments will be undertaken. A cost-utility analysis will be performed to assess the cost-effectiveness of surgery. We aim to recruit 89 subjects per arm (total sample size 178). Discussion. The results of this study will help guide treatment of dorsally displaced distal radial fractures in the elderly and assess whether surgery offers functional benefit to patients. This is an important finding, as the number of elderly distal radial fractures is estimated to increase in the future due to the ageing population. Evidence-based management strategies are therefore required to ensure the best outcome for the patient and to optimize the use of increasingly scarce healthcare resources. Cite this article: Bone Jt Open 2024;5(10):920–928


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 721 - 728
1 Jun 2022
Johansen A Ojeda-Thies C Poacher AT Hall AJ Brent L Ahern EC Costa ML

Aims. The aim of this study was to explore current use of the Global Fragility Fracture Network (FFN) Minimum Common Dataset (MCD) within established national hip fracture registries, and to propose a revised MCD to enable international benchmarking for hip fracture care. Methods. We compared all ten established national hip fracture registries: England, Wales, and Northern Ireland; Scotland; Australia and New Zealand; Republic of Ireland; Germany; the Netherlands; Sweden; Norway; Denmark; and Spain. We tabulated all questions included in each registry, and cross-referenced them against the 32 questions of the MCD dataset. Having identified those questions consistently used in the majority of national audits, and which additional fields were used less commonly, we then used consensus methods to establish a revised MCD. Results. A total of 215 unique questions were used across the ten registries. Only 72 (34%) were used in more than one national audit, and only 32 (15%) by more than half of audits. Only one registry used all 32 questions from the 2014 MCD, and five questions were only collected by a single registry. Only 21 of the 32 questions in the MCD were used in the majority of national audits. Only three fields (anaesthetic grade, operation, and date/time of surgery) were used by all ten established audits. We presented these findings at the Asia-Pacific FFN meeting, and used an online questionnaire to capture feedback from expert clinicians from different countries. A draft revision of the MCD was then presented to all 95 nations represented at the Global FFN conference in September 2021, with online feedback again used to finalize the revised MCD. Conclusion. The revised MCD will help aspirant nations establish new registry programmes, facilitate the integration of novel analytic techniques and greater multinational collaboration, and serve as an internationally-accepted standard for monitoring and improving hip fracture services. Cite this article: Bone Joint J 2022;104-B(6):721–728


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1821 - 1830
1 Dec 2021
Marson BA Manning JC James M Craxford S Deshmukh SR Perry DC Ollivere BJ

Aims. The aim of this study is to develop a core set of outcome domains that should be considered and reported in all future trials of childhood limb fractures. Methods. A four-phase study was conducted to agree a set of core outcome domains. Identification of candidate outcome domains were identified through systematic review of trials, and outcome domains relevant to families were identified through semi-structured interviews with 20 families (parent-child pairing or group). Outcome domains were prioritized using an international three-round Delphi survey with 205 panellists and then condensed into a core outcome set through a consensus workshop with 30 stakeholders. Results. The systematic review and interviews identified 85 outcome domains as relevant to professionals or families. The Delphi survey prioritized 30 upper and 29 lower limb outcome domains at first round, an additional 17 upper and 18 lower limb outcomes at second round, and four additional outcomes for upper and lower limb at the third round as important domains. At the consensus workshop, the core outcome domains were agreed as: 1) pain and discomfort; 2) return to physical and recreational activities; 3) emotional and psychosocial wellbeing; 4) complications from the injury and treatment; 5) rturn to baseline activities daily living; 6) participation in learning; 7) appearance and deformity; and 8) time to union. In addition, 9a) recovery of mobility and 9b) recovery of manual dexterity was recommended as a core outcome for lower and upper limb fractures, respectively. Conclusion. This set of core outcome domains is recommended as a minimum set of outcomes to be reported in all trials. It is not an exhaustive set and further work is required to identify what outcome tools should be used to measure each of these outcomes. Adoption of this outcome set will improve the consistency of research for these children that can be combined for more meaningful meta-analyses and policy development. Cite this article: Bone Joint J 2021;103-B(12):1821–1830


Bone & Joint Open
Vol. 1, Issue 2 | Pages 3 - 7
5 Feb 2020
Widnall J Capstick T Wijesekera M Messahel S Perry DC

Aims. This study sought to estimate the clinical outcomes and describe the nationwide variation in practice, as part of the feasibility workup for a National Institute for Health and Care Excellence (NICE) recommended randomized clinical trial to determine the optimal treatment of torus fractures of the distal radius in children. Methods. Prospective data collection on torus fractures presenting to our emergency department. Patient consent and study information, including a copy of the Wong-Baker Faces pain score, was issued at the first patient contact. An automated text message service recorded pain scores at days 0, 3, 7, 21, and 42 postinjury. A cross-sectional survey of current accident and emergency practice in the UK was also undertaken to gauge current practice following the publication of NICE guidance. Results. In all, 30 patients with a mean age of 8.9 years were enrolled over a six-week period. Of the 150 potential data points, data was captured in 146, making the data 97.3% complete. Pain scores were recorded at day 0 (mean 6.5 (95% confidence interval (CI) 5.7 to 7.3)), day 3 (4.4 (95% CI 3.5 to 5.2)), day 7 (3.0 (95% CI 2.3 to 3.6)), day 21 (1.2 (95% CI 0.7 to 1.7)) and day 42 (0.4 (95% CI 0.1 to 0.7)). Of the 100 units who participated in the nationwide survey, 38% were unaware of any local or national protocols regarding torus fractures, 41% treated torus fractures with cast immobilization, and over 60% of patients had follow-up arranged, both contradictory to national guidelines. Conclusion. We have demonstrated the severity, recovery trajectory, and variation in pain scores among children with torus fractures. We demonstrate excellent follow-up of patient outcomes using text messages. Despite national guidelines, there is significant variation in practice. This data directly informed the development of an ongoing nationwide randomized clinical trial – the FORearm Fracture Recovery in Children Evaluation (FORCE) study


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 162 - 169
1 Feb 2020
Hoellwarth JS Tetsworth K Kendrew J Kang NV van Waes O Al-Maawi Q Roberts C Al Muderis M

Aims. Osseointegrated prosthetic limbs allow better mobility than socket-mounted prosthetics for lower limb amputees. Fractures, however, can occur in the residual limb, but they have rarely been reported. Approximately 2% to 3% of amputees with socket-mounted prostheses may fracture within five years. This is the first study which directly addresses the risks and management of periprosthetic osseointegration fractures in amputees. Methods. A retrospective review identified 518 osseointegration procedures which were undertaken in 458 patients between 2010 and 2018 for whom complete medical records were available. Potential risk factors including time since amputation, age at osseointegration, bone density, weight, uni/bilateral implantation and sex were evaluated with multiple logistic regression. The mechanism of injury, technique and implant that was used for fixation of the fracture, pre-osseointegration and post fracture mobility (assessed using the K-level) and the time that the prosthesis was worn for in hours/day were also assessed. Results. There were 22 periprosthetic fractures; they occurred exclusively in the femur: two in the femoral neck, 14 intertrochanteric and six subtrochanteric, representing 4.2% of 518 osseointegration operations and 6.3% of 347 femoral implants. The vast majority (19/22, 86.4%) occurred within 2 cm of the proximal tip of the implant and after a fall. No fractures occurred spontaneously. Fixation most commonly involved dynamic hip screws (10) and reconstruction plates (9). No osseointegration implants required removal, the K-level was not reduced after fixation of the fracture in any patient, and all retained a K-level of ≥ 2. All fractures united, 21 out of 22 patients (95.5%) wear their osseointegration-mounted prosthetic limb longer daily than when using a socket, with 18 out of 22 (81.8%) reporting using it for ≥ 16 hours daily. Regression analysis identified a 3.89-fold increased risk of fracture for females (p = 0.007) and a 1.02-fold increased risk of fracture per kg above a mean of 80.4 kg (p = 0.046). No increased risk was identified for bilateral implants (p = 0.083), time from amputation to osseointegration (p = 0.974), age at osseointegration (p = 0.331), or bone density (g/cm2, p = 0.560; T-score, p = 0.247; Z-score, p = 0.312). Conclusion. The risks and sequelae of periprosthetic fracture after press-fit osseointegration for amputation should not deter patients or clinicians from considering this procedure. Females and heavier patients are likely to have an increased risk of fracture. Age, years since amputation, and bone density do not appear influential. Cite this article: Bone Joint J 2020;102-B(2):162–169


Bone & Joint Research
Vol. 9, Issue 12 | Pages 873 - 883
8 Dec 2020
Clement ND Ng N Simpson CJ Patton RFL Hall AJ Simpson AHRW Duckworth AD

Aims. The aims of this meta-analysis were to assess: 1) the prevalence of coronavirus disease 2019 (COVID-19) in hip fracture patients; 2) the associated mortality rate and risk associated with COVID-19; 3) the patient demographics associated with COVID-19; 4) time of diagnosis; and 5) length of follow-up after diagnosis of COVID-19. Methods. Searches of PubMed, Medline, and Google Scholar were performed in October 2020 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) statement. Search terms included “hip”, “fracture”, and “COVID-19”. The criteria for inclusion were published clinical articles reporting the mortality rate associated with COVID-19 in hip fracture patients. In total, 53 articles were identified and following full text screening 28 articles satisfied the inclusion criteria. Results. A total of 28 studies reported the mortality of COVID-19-positive patients, of which 21 studies reported the prevalence of COVID-19-positive patients and compared the mortality rate to COVID-19-negative patients. The prevalence of COVID-19 was 13% (95% confidence interval (CI) 11% to 16%) and was associated with a crude mortality rate of 35% (95% CI 32% to 39%), which was a significantly increased risk compared to those patients without COVID-19 (odds ratio (OR) 7.11, 95% CI 5.04 to 10.04; p < 0.001). COVID-19-positive patients were more likely to be male (OR 1.51, 95% CI 1.16 to 1.96; p = 0.002). The duration of follow-up was reported in 20 (71.4%) studies. A total of 17 studies reported whether a patient presented with COVID-19 (n = 108 patients, 35.1%) or developed COVID-19 following admission (n = 200, 64.9%), of which six studies reported a mean time to diagnosis of post-admission COVID-19 at 15 days (2 to 25). Conclusion. The prevalence of COVID-19 was 13%, of which approximately one-third of patients were diagnosed on admission, and was associated with male sex. COVID-19-positive patients had a crude mortality rate of 35%, being seven times greater than those without COVID-19. Due to the heterogenicity of the reported data minimum reporting standards of outcomes associated with COVID-19 are suggested. Cite this article: Bone Joint Res 2020;9(12):873–883


Bone & Joint Research
Vol. 8, Issue 10 | Pages 489 - 494
1 Oct 2019
Klasan A Bäumlein M Dworschak P Bliemel C Neri T Schofer MD Heyse TJ

Objectives. Periprosthetic femoral fractures (PFFs) have a higher incidence with cementless stems. The highest incidence among various cementless stem types was observed with double-wedged stems. Short stems have been introduced as a bone-preserving alternative with a higher incidence of PFF in some studies. The purpose of this study was a direct load-to-failure comparison of a double-wedged cementless stem and a short cementless stem in a cadaveric fracture model. Methods. Eight hips from four human cadaveric specimens (age mean 76 years (60 to 89)) and eight fourth-generation composite femurs were used. None of the cadaveric specimens had compromised quality (mean T value 0.4 (-1.0 to 5.7)). Each specimen from a pair randomly received either a double-wedged stem or a short stem. A materials testing machine was used for lateral load-to-failure test of up to a maximal load of 5000 N. Results. Mean load at failure of the double-wedged stem was 2540 N (1845 to 2995) and 1867 N (1135 to 2345) for the short stem (p < 0.001). All specimens showed the same fracture pattern, consistent with a Vancouver B2 fracture. The double-wedged stem was able to sustain a higher load than its short-stemmed counterpart in all cases. Failure force was not correlated to the bone mineral density (p = 0.718). Conclusion. Short stems have a significantly lower primary load at failure compared with double-wedged stems in both cadaveric and composite specimens. Surgeons should consider this biomechanical property when deciding on the use of short femoral stem. Cite this article: A. Klasan, M. Bäumlein, P. Dworschak, C. Bliemel, T. Neri, M. D. Schofer, T. J. Heyse. Short stems have lower load at failure than double-wedged stems in a cadaveric cementless fracture model. Bone Joint Res 2019;8:489–494. DOI: 10.1302/2046-3758.810.BJR-2019-0051.R1


Bone & Joint Research
Vol. 6, Issue 10 | Pages 584 - 589
1 Oct 2017
den Teuling J Pauwels B Janssen L Wyers C Janzing HMJ van den Bergh J Morrenhof JW

Objectives. The goal of this study is to investigate the relation between indicators of osteoporosis (i.e., bone mineral density (BMD), and Cortical Index (CI)) and the complexity of a fracture of the proximal humerus as a result of a low-energy trauma. Methods. A retrospective chart review of 168 patients (mean age 67.2 years, range 51 to 88.7) with a fracture of the proximal humerus between 2007 and 2011, whose BMD was assessed at the Fracture Liaison Service with Dual Energy X-ray Absorptiometry (DXA) measurements of the hip, femoral neck (FN) and/or lumbar spine (LS), and whose CI and complexity of fracture were assessed on plain anteroposterior radiographs of the proximal humerus. Results. No significant differences were found between simple and complex fractures of the proximal humerus in the BMD of the hip, FN or LS (all p > 0.3) or in the CI (p = 0.14). Only the body mass index was significantly higher in patients with a complex fracture compared with those with a simple fracture (26.9 vs 25.2; p = 0.05). Conclusion. There was no difference in BMD of the hip, FN, LS or CI of the proximal humerus in simple compared with complex fractures of the proximal humerus after a low-energy trauma. Factors other than the BMD and CI, for example body mass index, may play a more important role in the complexity of this fracture. Cite this article: J.W.A.M. den Teuling, B.S. Pauwels, L. Janssen, C.E. Wyers, H. M. J. Janzing, J.P.W. van den Bergh, J. W. Morrenhof. The Influence of bone mineral density and cortical index on the complexity of fractures of the proximal humerus. Bone Joint Res 2017;6:584–589. DOI: 10.1302/2046-3758.610.BJR-2017-0080


Bone & Joint Research
Vol. 6, Issue 5 | Pages 270 - 276
1 May 2017
Gosiewski JD Holsgrove TP Gill HS

Objectives. Fractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix. Methods. Devices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm. 3. , 0.16 g/cm. 3. and 0.24 g/cm. 3. ). Each torsion test comprised a steady ramp of 1°/minute up to an angular displacement of 10°. Results. The deployable crucifix design (X-Bolt), was more torsionally stable, compared to both the dynamic hip screw (DHS, p = 0.008) and helical blade (DHS Blade, p= 0.008) designs in bone substitute material representative of osteoporotic bone (0.16 g/cm. 3. polyurethane foam). In 0.08 g/cm. 3. density substrate, the crucifix design (X-Bolt) had a higher resistance to torsion than the screw (DHS, p = 0.008). There were no significant differences (p = 0.101) between the implants in 0.24 g/cm. 3. density bone substitute. Conclusions. Our findings indicate that the clinical standard proximal fracture fixator design, the screw (DHS), was the least effective at resisting torsional load, and a novel crucifix design (X-Bolt), was the most effective design in resisting torsional load in bone substitute material with density representative of osteoporotic bone. At other densities the torsional stability was also higher for the X-Bolt, although not consistently significant by statistical analysis. Cite this article: J. D. Gosiewski, T. P. Holsgrove, H. S. Gill. The efficacy of rotational control designs in promoting torsional stability of hip fracture fixation. Bone Joint Res 2017;6:270–276. DOI: 10.1302/2046-3758.65.BJR-2017-0287.R1