Aims. Patients with A1 and A2 trochanteric
Aims. Factors associated with high mortality rates in geriatric
Aims. This study aimed to identify risk factors (patient, healthcare system, and socioeconomic) for mortality after
Aims. The aims of this study were to assess quality of life after
Aims. To investigate if preoperative CT improves detection of unstable trochanteric
Aims. The aim of this study was to describe variation in
Aims. The aim of this study was to describe the current pathways of care for patients with a fracture of the hip in five low- and middle-income countries (LMIC) in South Asia (Nepal and Sri Lanka) and Southeast Asia (Malaysia, Thailand, and the Philippines). Methods. The World Health Organization Service Availability and Readiness Assessment tool was used to collect data on the care of
Aims. We assessed the value of the Clinical Frailty Scale (CFS) in the prediction of adverse outcome after
Aims. National
Aims. The aim of this study to compare 30-day survival and recovery of mobility between patients mobilized early (on the day of, or day after surgery for a hip fracture) and patients mobilized late (two days or more after surgery), and to determine whether the presence of dementia influences the association between the timing of mobilization, 30-day survival, and recovery. Methods. Analysis of the National
Aims. The aim of this study was to explore current use of the Global Fragility Fracture Network (FFN) Minimum Common Dataset (MCD) within established national
Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for
Aims.
Aims. Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson’s hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes. Methods. Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries. Results. In total, 1,312 Thompson’s hemiarthroplasties were analyzed (mean age at surgery 82.8 years); 125 complications were recorded, necessitating 82 returns to theatre. These included 14 patients undergoing aspiration or manipulation under anaesthesia, 68 reoperations (5.2%) for debridement and implant retention (n = 12), haematoma evacuation (n = 2), open reduction for dislocation (n = 1), fixation of periprosthetic fracture (n = 5), and 48 revised stems (3.7%), for infection (n = 13), dislocation (n = 12), aseptic loosening (n = 9), persistent pain (n = 6), periprosthetic fracture (n = 4), acetabular erosion (n = 3), and metastatic bone disease (n = 1). Their status at ten years is summarized as follows: 1,180 (89.9%) dead without revision, 34 (2.6%) dead having had revision, 84 (6.6%) alive with the stem unrevised, and 14 (1.1%) alive having had revision. Cumulative implant survivorship was 90.3% at ten years; patient survivorship was 7.4%. Conclusion. The Thompson’s stem demonstrates very low rates of complications requiring reoperation and revision, up to ten years after the index procedure. Fewer than one in ten patients live for ten years after fracture. This study supports the use of a cemented Thompson’s implant as a cost-effective option for frail
Objectives. To study the measurement properties of a joint specific patient
reported outcome measure, a measure of capability and a general
health-related quality of life (HRQOL) tool in a large cohort of
patients with a
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. Controversy exists regarding
the optimal treatment for independent patients with displaced intracapsular fractures
of the proximal femur. The recognised alternatives are hemiarthroplasty
and total hip replacement. At present there is no established standard
of care, with both types of arthroplasty being used in many centres.
The principal advantages of total hip replacement are a functional
benefit over hemiarthroplasty and a reduced risk of revision surgery.
The principal criticism is the increased risk of dislocation. We
believe that an alternative acetabular component may reduce the
risk of dislocation but still provide the functional benefit of
total hip replacement in these patients. We therefore propose to
investigate the dislocation risk of a dual-mobility acetabular component
compared with standard polyethylene component in total hip replacement
for independent patients with displaced intracapsular fractures
of the proximal femur within the framework of the larger WHiTE (Warwick
Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article:
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. Controversy exists regarding
the optimal treatment for patients with unstable trochanteric proximal
femoral fractures. The recognised treatment alternatives are extramedullary
fixation usually with a sliding hip screw and intramedullary fixation
with a cephalomedullary nail. Current evidence suggests that best
results and lowest complication rates occur using a sliding hip screw.
Complications in these difficult fractures are relatively common
regardless of type of treatment. We believe that a novel device,
the X-Bolt dynamic plating system, may offer superior fixation over
a sliding hip screw with lower reoperation risk and better function.
We therefore propose to investigate the clinical effectiveness of
the X-bolt dynamic plating system compared with standard sliding
hip screw fixation within the framework of a the larger WHiTE (Warwick
Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article:
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. The National Hip Fracture
Audit currently provides a framework for service evaluation. This
evaluation is based upon the assessment of process rather than assessment
of patient-centred outcome and therefore it fails to provide meaningful
data regarding the clinical effectiveness of treatments. This study
aims to capture data from the cohort of patients who present with
a fracture of the proximal femur at a single United Kingdom Major
Trauma Centre. Patient-centred outcomes will be recorded and provide
a baseline cohort within which to test the clinical effectiveness
of experimental interventions.
Aims. Ankle fractures are common injuries and the third most common fragility fracture. In all, 40% of ankle fractures in the frail are open and represent a complex clinical scenario, with morbidity and mortality rates similar to
Aims. The aim of this study was to describe services available to patients with periprosthetic femoral fracture (PPFF) in England and Wales, with focus on variation between centres and areas for care improvement. Methods. This work used data freely available from the National