Introduction. The direct anterior approach (DAA) for total hip arthroplasty continues to gain popularity. Consequently, more procedures are being performed with the patient supine. The approach often utilizes a special leg positioner to assist with femoral exposure. Although the supine position may seem to allow for a more reproducible pelvic position at the time of cup implantation, there is limited evidence as to the effects on pelvic tilt with such leg positioners. Furthermore, the DAA has led to increased popularity of specific softwares, ie. Radlink or JointPoint, that facilitate the intra-op analysis of component position from fluoroscopy images. The aim of this study was to assess the difference in
Introduction. The Intellijoint HIP system is a mini-optical navigation system designed to intraoperatively assist with
Introduction. Cup malposition in hip arthroplasty and hip resurfacing is associated with instability, accelerated wear, and the need for revision. The current study assesses the validity of intraoperative assessment using a specialized software to analyze intraoperative radiographs. Methods.
Introduction. The limited field of view with less-invasive hip approaches for total hip arthroplasty can make a reliable cup positioning more challenging. The aim of this study was to evaluate the accuracy of cup placement between the traditional transgluteal approach and the anterior approach in a routine setting. Objectives. We asked if the (1) accuracy, (2) precision, and (3) number of outliers of the prosthetic
Introduction. The resultant
The goal of this study was to validate accuracy and reproducibility of a new 2D/3D reconstruction-based program called “HipRecon” for determining
Introduction. Studies show that cup malpositioning using conventional techniques occurs in 50 to 74% of cases defined. Assessment of the utility of improved methods of placing acetabular components depends upon the accuracy of the method of measuring component positioning postoperatively. The current study reports on our preliminary experience assessing the accuracy of EOS images and application specific software to assess
A 10° deviation from the ideal
The radiographic analysis of over 5000 metal on metal (MoM) hips using Ein Bild Roentgen Analyse (EBRA) software have been recently published in an attempt to determine the influence of
This matched cohort study aims to (a) assess differences in spinopelvic characteristics of patients having sustained a dislocation following THA and a control THA group without dislocation; (b) identify spinopelvic characteristics associated with risk of dislocation and; (c) propose an algorithm to define the optimum
Introduction. Cup malposition in hip arthroplasty and hip resurfacing is associated with instability, accelerated wear, and the need for revision. A recent study measuring
Introduction. Appropriate acetabular
Obtaining consistently an optimal
INTRODUCTION.
Aims: Postoperative dislocation of the implant is still an unsolved problem in THR. Malposition of the socket is reported to be one major risk factor. The aim of this study was to investigate the inßuence of
INTRODUCTION. Poor acetabular
Optimal alignment of the acetabular cup component is crucial for good outcome of total hip arthroplasty [THA]. Increased accuracy of implant positioning may improve clinical outcome. To achieve this, patient specific instrumentation was developed. A patient-specific guide manufactured by 3D printing was designed to aid in positioning of the cup component with a pre-operatively defined anteversion and inclination angle. The guide fits perfectly on the acetabular rim. An alignment K-wire in a pre-operatively planned orientation is used as visual reference during cup implantation. Accuracy of the device was tested on 6 cadaveric specimens. During the experiment, cadavers were positioned for a THA procedure using a posterolateral approach. A normal-sized incision was made and approach used as in the conventional surgical procedure. The PSI was subsequently fitted onto the acetabular rim and secured into its unique position due to its patient specific design. The metallic pin was placed in a drill hole of the PSI. Post-operative CT image data of each acetabulum with the placed pin were transferred to Mimics and the 3D model was registered to the pre-operative one. The anteversion and inclination of the placed pin was calculated and compared to the pre-operatively planned orientation. The absolute difference in degrees was evaluated. A secondary test was carried out to assess the error during impaction while observing the alignment K-wire as a visual reference. In a laboratory setting, error during impaction with a visual reference of the K-wire was measured. Deviation from planning showed to be on average 1.04° for anteversion and 2.19° for inclination. By visually aligning the impactor with this alignment K-wire, the surgeon may achieve cup placement as pre-operatively planned. The effect of the visual alignment itself was also evaluated in a separate test-rig showing minimal deviations in the same range. The alignment validation test resulted in an average deviation of 1.2° for inclination and 1.4° for anteversion between the metallic alignment K-wire used as visual reference and the metallic K-wire impacted by the test subjects. The inter-user variability was 0.9° and 0.8° for anteversion and inclination respectively. The intra-user variability was 1.6° and 1.0° for anteversion and inclination respectively. Tests per test subject were conducted in a consecutive manner. We investigated the accuracy of two factors affecting accuracy in the cup insertion with PSI, i.e. accuracies of the errors of bony fitting and cup impaction. Since the accuracy of the major contributing factors to the overall accuracy of PSI for cup insertion with linear visual reference of a metallic K-wire was within the acceptable range of 2 to 3 degrees, we state that the PSI we have designed assists to achieve the preoperatively planned orientation of the cup and as such leads to the reduction of outliers in
INTRODUCTION. Dislocation is one of the most frequent complications in total hip arthroplasty (THA), affecting an estimated 1% to 5% of THA patients. Malposition of the acetabular cup is thought to be a likely contributor. As the field searches for solutions, new experimental methods can help engineers, scientists, and surgeons better understand the problem as well as evaluate novel techniques and products. OBJECTIVES. Create a laboratory simulation to assess patient positioning and pelvic motion during THA. Apply this simulation to assess (1) variation in patient positioning; (2) various methods to identify the pelvic plane via palpated anatomic landmarks. METHODS. A patient surrogate was developed to recreate patient-like modality, palpation, and motion, especially focusing on the spine's influence on pelvic flexion and rotation. Five different registration methods were evaluated (3 supine, 2 lateral decubitus). An ASIS-to-ASIS measurement was always used in calculations. The other axes measured were: 1) supine/trunk; 2) supine/ASIS-to-Pubis; 3) supine/neutral femoral axis; 4) LD/spine; and 5) LD/trunk. Three infrared LED markers were attached to the iliac spine of the surrogate's pelvis and monitored with an Optotrak Certus motion-tracking camera (Northern Digital). A second sensor was mounted to the top of a patient positioner (Innomed) to measure the orientation of the pelvis relative to the positioner. A third sensor was mounted to a set of calipers, which were aligned with anatomic landmarks during registration. To compare results from registration methods, a reference orientation of the pelvis was recorded by digitizing landmarks comprising the anterior pelvic plane (APP). The APP is the plane created by three points: the left ASIS, right ASIS, and midpoint of pubic tubercles. Theoretical pelvic orientation was calculated using these digitized points. The vectors generated from the gross anatomic registration steps were used to calculate the measured orientation of the pelvis compared to theoretical. The rotation, or error, matrix between theoretical and measured pelvic orientations was computed and then projected on an APP coordinate system to translate the error matrix to cup inclination and version. RESULTS. Inter- and intra-operator variability was good for most registration methods. The error in
The purpose of this preliminary study was to evaluate the feasibility and accuracy of HipAlign (OrthAlign, Inc., USA) system for