Introduction.
Aims. Optimal glenoid positioning in reverse shoulder arthroplasty (RSA) is crucial to provide impingement-free range of motion (ROM). Lateralization and inclination correction are not yet systematically used. Using planning software, we simulated the most used glenoid implant positions. The primary goal was to determine the configuration that delivers the best theoretical impingement-free ROM. Methods. With the use of a 3D planning software (Blueprint) for RSA, 41 shoulders in 41 consecutive patients (17 males and 24 females; means age 73 years (SD 7)) undergoing RSA were planned. For the same anteroposterior positioning and retroversion of the glenoid implant, four different glenoid baseplate configurations were used on each shoulder to compare ROM: 1) no correction of the RSA angle and no lateralization (C-L-); 2) correction of the RSA angle with medialization by inferior reaming (C+M+); 3) correction of the RSA angle without lateralization by superior compensation (C+L-); and 4) correction of the RSA angle and additional lateralization (C+L+). The same humeral inlay implant and positioning were used on the humeral side for the four different glenoid configurations with a 3 mm symmetric 135° inclined polyethylene liner. Results. The configuration with lateralization and correction of the RSA angle (C+L+) led to better ROM in flexion, extension, adduction, and external rotation (p ≤ 0.001). Only internal rotation was not significantly different between groups (p = 0.388). The configuration where correction of the inclination was done by medialization (C+M+) led to the worst ROM in adduction, extension, abduction, flexion, and external rotation of the shoulder. Conclusion. Our software study shows that, when using a 135° inlay reversed humeral implant, correcting
Background. Virtual planning of shoulder arthroplasty has gained recent popularity. Combined with patients specific instrumentation, several systems have been developed that allow the surgeon to accurately appreciate and correct glenoid deformities in version and inclination. While each virtual software platform utilizes a consistent algorithm for calculating these measurements, it is imperative for the surgeon to recognize any differences that may exist amongst software platforms and characterize any variability. Methods. A case-control study of all CT scans of patients previously pre-operatively planned using MatchPoint SurgiCase® software were uploaded into the BluePrint software. The cohort represents surgical planning for total shoulder arthroplasty and reverse shoulder arthroplasty with varying degrees of glenoid deformity. Glenoid version and inclination will be recorded for each CT scan using both software platforms. Results. A total of 38 patient CT scans previously planned using MatchPoint Surgicase® software were uploaded into the BluePrint software. The mean difference for glenoid version between the two software programs was 2.497° (±1.724°) with no significant differences in measured glenoid version readings between BluePrint and SurgiCase software (p=0.8127). No significant differences were seen in the measured
To provide a comprehensive radiographic, clinical, and functional description of the shoulder in Apert Syndrome. A cohort of nine Apert Syndrome patients (ages nine to twenty-seven) followed at a tertiary care facility was included in this prospective study. Patients were clinically assessed with physical examination and completion of two validated functional assessment tools, the Shoulder Pain and Disability Index (SPADI) and AAOS Paediatrics Questionnaire (PODCI). Radiographs were obtained of both shoulders and a standardised protocol MRI was performed on the dominant shoulder of all participants. All patients had some degree of functional impairment attributable to their shoulder pathology. Physical examination consistently revealed reduced forward flex-ion and abduction. Radiographic findings were similar to previous reports, with pervasive osseous dysplasia of the shoulder joint. Medial humeral head hypoplasia was seen in eight out of nine patients and greater tuberosity overgrowth in seven out of nine patients. MR imaging of the shoulder, not previously performed in a cohort of Apert patients, allowed better delineation of abnormalities seen radiographically such as a central glenoid cleft, seen in eight out of nine patients. It also revealed a new finding of inferior
Background. Degeneration of the shoulder joint is a frequent problem. There are two main types of shoulder degeneration: Osteoarthritis and cuff tear arthropathy (CTA) which is characterized by a large rotator cuff tear and progressive articular damage. It is largely unknown why only some patients with large rotator cuff tears develop CTA. In this project, we investigated CT data from ‘healthy’ persons and patients with CTA with the help of 3D imaging technology and statistical shape models (SSM). We tried to define a native scapular anatomy that predesignate patients to develop CTA. Methods. Statistical shape modeling and reconstruction:. A collection of 110 CT images from patients without glenohumeral arthropathy or large cuff tears was segmented and meshed uniformly to construct a SSM. Point-to-point correspondence between the shapes in the dataset was obtained using non-rigid template registration. Principal component analysis was used to obtain the mean shape and shape variation of the scapula model. Bias towards the template shape was minimized by repeating the non-rigid template registration with the resulting mean shape of the first iteration. Eighty-six CT images from patients with different severities of CTA were analyzed by an experienced shoulder surgeon and classified. CT images were segmented and inspected for signs of glenoid erosion. Remaining healthy parts of the eroded scapulae were partitioned and used as input of the iterative reconstruction algorithm. During an iteration of this algorithm, 30 shape components of the shape model are optimized and the reconstructed shape is aligned with the healthy parts. The algorithm stops when convergence is reached. Measurements. Automatic 3D measurements were performed for both the healthy and reconstructed shapes, including
Introduction. The Walch Type B2 glenoid has the hallmark features of posteroinferior glenoid erosion, retroversion, and posterior humeral head subluxation. Although our understanding of the pathoanatomy of bone loss and its evolution in Type B's has improved, the etiology remains unclear. Furthermore, the morphology of the humerus in Walch B types has not been studied. The purpose of this imaging based anthropometric study was to examine the humeral torsion in Walch Type B2 shoulders. We hypothesized that there would be a compensatory decrease in humeral retroversion in Walch B2 glenoids. Methods. Three-dimensional models of the full length humerus were generated from computed tomography data of normal cadaveric (n = 59) and Walch Type B shoulders (n = 59). An anatomical coordinate system referencing the medial and lateral epicondyles was created for each model. A simulated humeral head osteotomy plane was created and used to determine humeral version relative to the epicondylar axis and the head-neck angle. Measurements were repeated by two experienced fellowship-trained shoulder surgeons to determine inter-rater reliability. Glenoid parameters (version, inclination and 2D critical shoulder angle) and posterior humeral head subluxation were calculated in the Type B group to determine the pathologic glenohumeral relationship. Two-way ANOVAs compared group and sex within humeral version and head-neck angle, and intra-class correlation coefficients (ICCs) with a 2-way random effects model and absolute agreement were used for inter-rater reliability. Results. There were statistically significant differences in humeral version between normal and Type B shoulders (p < .001) and between males and females within the normal group (p = .043). Normal shoulders had a humeral retroversion of 36±12°, while the Walch Type B group had a humeral retroversion of 14±9° relative to the epicondylar axis. For head-neck angle, there were no significant differences between sexes (p = .854), or between normal and Type B shoulders when grouped by sex (p = .433). In the Type B group, the mean glenoid version was 22±7°,
BACKGROUND. Abnormal glenoid version positioning has been recognized as a cause of glenoid component failure caused by the rocking horse phenomenon. In contrast, the importance of the
Purpose: The purpose of this retrospective studies is to evaluate the real effectiveness, with clinical and radiologic evalutation, of the eccentric glenosphere and also how a correct position can prevent the scapular notching. Material and Methods: We inplanted in 18 patients, with eccentric arthopaty, a 36 mm eccentric glenoshere.24 months’ clinical and radiographic follow up. All patient were assessed preoperatively and postoperatively with the Constant Score. In the post-operative radiographic control we have taken in consideration: the presence of notching, psna (prosthesis-scapular neck angle), pgrd (peg glenoid distance),
Pre-operative 3D glenoid planning improves component placement in terms of version, inclination, offset and orientation. Version and inclination measurements require the position of the inferior angle. As a consequence, current planning tools require a 3D model of the full scapula to accurately determine the glenoid parameters. Statistical shape models (SSMs) can be used to reconstruct the missing anatomy of bones. Therefore, the objective of this study is to develop and validate an SSM for the reconstruction of the inferior scapula, hereby reducing the irradiation exposure for patients. The training dataset for the statistical shape consisted of 110 CT images from patients without observable scapulae pathologies as judged by an experienced shoulder surgeon. 3D scapulae models were constructed from the segmented images. An open-source non-rigid B-spline-based registration algorithm was used to obtain point-to-point correspondences between the models. A statistical shape model was then constructed from the dataset using principal component analysis. Leave-one-out cross-validation was performed to evaluate the accuracy of the predicted glenoid parameters from virtual partial scans. Five types of virtual partial scans were created on each of the training set models, where an increasing amount of scapular body was removed to mimic a partial CT scan. The statistical shape model was reconstructed using the leave-one-out method, so the corresponding training set model is no longer incorporated in the shape model. Reconstruction was performed using a Monte Carlo Markov chain algorithm, random walk proposals included both shape and pose parameters, the closest fitting proposal was selected for the virtual reconstruction. Automatic 3D measurements were performed on both the training and reconstructed 3D models, including
Reverse shoulder arthroplasty has a high complication rate related to glenoid implant instability and screw loosening. Better radiographic post-operative evaluation may help in understanding complications causes. Medical radiographic imaging is the conventional technique for post-operative component placement analysis. Studies suggest that volumetric CT is better than use of CT slices or conventional radiographs. Currently, post-operative CT use is limited by metal-artifacts in images. This study evaluated inter-observer reliability of pre-operative and post-operative CT images registration to conventional approaches using radiographs and CT slices in measuring reverse shoulder arthroplasty glenoid implant and screw percentage in bone. Pre-operative and post-operative CT scans, and post-operative radiographs were obtained from six patients that had reverse shoulder arthroplasty. CT scans images were imported into a medical imaging processing software and each scapula, glenoid implant and inferior screw were reconstructed as 3D models. Post-operative 3D models were imported into the pre-operative reference frame and matched to the pre-operative scapula model using a paired-point and a surface registration. Measurements on registered CT models were done in reference to the pre-operative scapula model coordinate frame defined by a computer-assisted designed triad positioned in respect to the center of the glenoid fossa and trigonum scapulae (medial-lateral, z axis) and superior and inferior glenoid tubercle (superior-inferior, y axis). The orthogonal triad third axis defined the anterior-posterior axis (x axis). A duplicate triad was positioned along the central axis of the glenoid implant model. Using a virtual protractor, the
Severe glenoid bone loss in patients with osteoarthritis with intact rotator cuff is associated with posterior glenoid bone loss and posterior humeral subluxation. Management of severe glenoid bone loss during shoulder arthroplasty is controversial and technically challenging and options range from humeral hemiarthroplasty, anatomic shoulder replacement with glenoid bone grafting or augmented glenoid component implantation, to reverse replacement with reaming to correct version or structural bone grafting or metallic augmentation of the bone deficiency. Shoulder replacement with severe glenoid bone loss is technically challenging and characterised by higher rates of complications and revisions. Hemiarthroplasty has limited benefit for pain relief and function especially if eccentric glenoid wear exists. Bone loss with >15 degrees of retroversion likely requires version correction include bone-grafting, augmented glenoid components, or reverse total shoulder replacement. Asymmetric reaming may improve version but is limited to 15 degrees of version correction in order to preserve subchondral bone and glenoid bone vault depth. Bone-grafting of glenoid wear and defects has had mixed results with graft-related complications, periprosthetic radiolucent lines, and glenoid component failure of fixation. Implantation of an augmented wedge or step polyethylene glenoid component improves joint version while preserving subchondral bone, but is technically demanding and with minimal short term clinical follow-up. A Mayo study demonstrated roughly 50% of patients with posteriorly augmented polyethylene had radiolucent lines and 1/3 had posterior subluxation. Another wedge polyethylene design had 66% with bone ingrowth around polyethylene fins at 3 years. Long term outcomes are unknown for these new wedge augmented glenoid components. Reverse shoulder arthroplasty avoids many risks of anatomic replacement glenoid component fixation and stability but is associated with a high complication rate (15%) including neurologic and baseplate loosening and often requires structural bone grafting behind the baseplate with suboptimal outcomes or metallic augmented baseplates with limited evidence and short term outcomes. Reverse replacement with baseplate bone grafting or metal augmentation is technically challenging due to limited native glenoid bone stock available for baseplate component ingrowth and long term fixation. Failure to correct
Aim: To investigate the natural history and the impact of reconstruction in shoulder deformities due to obstetrical brachial plexus palsy. Methods: Pre and postoperative CT scans of bilateral upper extremities of 28 patients with obstetrical palsy were studied. The age during the preoperative CT scan ranged from 1.5 months to 10 years (average: 4 ± 3 years). 17 patients had Erbñs palsy and 11 global plexus involvement. Eighteen had primary shoulder reanimation mainly via intraplexus neurotization. Palliative surgery in 25 patients included trapezius transfer for shoulder abduction, adductors release and rerouting of the latissimus dorsi and terres major for external rotation, scapula stabilization and rotational osteotomy of the humerus. The CT measurements included: humeral head retroversion, spinoscapular angle,
For any image guided surgery, independently of the technique which is used (navigation, templates, robotics), it is necessary to get a 3D bone surface model from CT or MR images. Such model is used for planning, registration and visualization. We report that graphical representation of patient bony structure and the surgical tools, inter-connectively with the tracking device and patient-to-image registration, are crucial components in such system. For Total Shoulder Arthroplasty (TSA), there are many challenges. The most of cases that we are working with are pathological cases such as rheumatoid arthritis, osteoarthritis disease. The CT images of these cases often show a fusion area between the glenoid cavity and the humeral head. They also show severe deformations of the humeral head surface that result in a loss of contours. These fusion area and image quality problems are also amplified by well-known CT-scan artefacts like beam-hardening or partial volume effects. The state of the art shows that several segmentation techniques, applied to CT-Scans of the shoulder, have already been disclosed. Unfortunately, their performances, when used on pathological data, are quite poor. In severe cases, bone-on-bone arthritis may lead to erosion-wearing away of the bone. Shoulder replacement surgery, also called shoulder arthroplasty, is a successful, pain-relieving option for many people. During the procedure, the humeral head and the glenoid bone are replaced with metal and plastic components to alleviate pain and improve function. This surgical procedure is very difficult and limited to expert centres. The two main problems are the minimal surgical incision and limited access to the operated structures. The success of such procedure is related to optimal prosthesis positioning. For TSA, separating the humeral head in the 3D scanner images would allow enhancing the vision field for the surgeon on the glenoid surface. So far, none of the existing systems or software packages makes it possible to obtain such 3D surface model automatically from CT images and this is probably one of the reasons for very limited success of Computer Assisted Orthopaedic Surgery (CAOS) applications for shoulder surgery. This kind of application often has been limited due to CT-image segmentation for severe pathologic cases and patient to image registration. The aim of this paper is to present a new image guided planning software based on CT scan of the patient and using bony structure recognition, morphological and anatomical analysis for the operated region. Volumetric preoperative CT datasets have been used to derive a surface model shape of the shoulder. The proposed planning software could be used with a conventional localisation system, which locates in 3D and in real time position and orientation for surgical tools using passive markers associated to rigid bodies that will be fixed on the patient bone and on the surgical instruments. 20 series of patients aged from 42 years to 91 years (mean age of 71 years) were analysed. The first step of this planning software is fully automatic segmentation method based on 3D shape recognition algorithms applied to each object detected in the volume. The second step is a specific processing that only treats the region between the humerus and the glenoid surface in order to separate possible contact areas. The third step is a full morphological analysis of anatomical structure of the bone. The glenoid surface and the glenoid vault are detected and a 3D version and inclination angle of the glenoid surface are computed. These parameters are very important to define an optimal path for drilling and reaming glenoid surface. The surgeon can easily modify the position of the implant in 3D aided by 3D and 2D view of the patient anatomy. The