Aim. We present the long-term surgical outcomes, complications, implant survival and causes of implant failure in patients treated with the modified
Introduction: The aim of this study is to compare the efficacy of the AO Universal Spine System (AO USS) with Harrington-Luque instrumentation for the treatment of King type II idiopathic scoliosis. Methods/Results: A retrospective analysis was performed on two groups of patients with King II adolescent idiopathic scoliosis. The first group consisted of 40 consecutive patients treated with Harrington-Luque instrumentation between 1990 and 1993. The second group consisted of 25 consecutive patients treated with AO USS instrumentation between 1994 and 1996. The groups were well matched with respect to age, sex and curve severity. Inclusion criteria were patients over the age of 12 years with a King II curve pattern and a Cobb angle of greater than 40°. Half of the patients in each group underwent anterior release prior to posterior fusion. All patients were followed up six monthly for 18 months. The thoracic curve, lumbar curve, kyphosis and lordosis were measured using the Cobb method. The mean pre-operative thoracic and lumbar curves were 62° and 43.9° respectively in the
Study design: To analyse the long term effect of
Introduction: In 1962
Objective: To evaluate the long term radiological and clinical outcome after posterior correction of adolescent right thoracic idiopathic scoliosis with Cotrel-Dubousset instrumentation (CDI) and
Guidelines for the management of patients with metastatic bone
disease (MBD) have been available to the orthopaedic community for
more than a decade, with little improvement in service provision
to this increasingly large patient group. Improvements in adjuvant
and neo-adjuvant treatments have increased both the number and overall
survival of patients living with MBD. As a consequence the incidence
of complications of MBD presenting to surgeons has increased and
is set to increase further. The British Orthopaedic Oncology Society
(BOOS) are to publish more revised detailed guidelines on what represents
‘best practice’ in managing patients with MBD. This article is designed
to coincide with and publicise new BOOS guidelines and once again
champion the cause of patients with MBD. A series of short cases highlight common errors frequently being
made in managing patients with MBD despite the availability of guidelines.Objectives
Methods
Objectives. We investigated the reliability of the cobalt-chromium (CoCr) synovial joint fluid ratio (JFR) in identifying the presence of a severe aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) response and/or suboptimal taper performance (SOTP) following metal-on-metal (MoM) hip arthroplasty. We then examined the possibility that the CoCr JFR may influence the serum partitioning of Co and Cr. Methods. For part A, we included all revision surgeries carried out at our unit with the relevant data, including volumetric wear analysis, joint fluid (JF) Co and Cr concentrations, and ALVAL grade (n = 315). Receiver operating characteristic curves were constructed to assess the reliability of the CoCr JFR in identifying severe ALVAL and/or SOTP. For part B, we included only patients with unilateral prostheses who had given matched serum and whole blood samples for Co and Cr analysis (n = 155). Multiple regression was used to examine the influence of JF concentrations on the serum partitioning of Co and Cr in the blood. Results. A CoCr JFR > 1 showed a specificity of 83% (77% to 88%) and sensitivity of 63% (55% to 70%) for the detection of severe ALVAL and/or SOTP. In patients with CoCr JFRs > 1, the median blood Cr to serum Cr ratio was 0.99, compared with 0.71 in patients with CoCr JFRs < 1 (p < 0.001). Regression analysis demonstrated that the blood Cr to serum Cr value was positively associated with the JF Co concentration (p = 0.011) and inversely related to the JF Cr concentration (p < 0.001). Conclusion. Elevations in CoCr JFRs are associated with adverse biological (severe ALVAL) or tribocorrosive processes (SOTP). Comparison of serum Cr with blood Cr concentrations may be a useful additional clinical tool to help to identify these conditions. Cite this article: D. J. Langton, S. Natu, C. F.
The treatment of acetabular metastases with total hip arthroplasty is technically challenging often with significant loss of structural continuity in the medial wall and roof of the acetabulum, as described by
The treatment of massive chronic tears is problematic. The re-tear rate following surgery for extensive cuff tears remains high, and there is little consensus regarding optimum treatment. To investigate the outcome of a cohort of patients who had open repair of an extensive cuff tear using the Leeds Kuff patch as an augment. A retrospective cohort study of consecutive patients with a massive cuff tear who had surgery in our regional elective orthopaedic centre over a two year period from January 2015 to Dec 2016. All patients followed identical rehabilitation protocols, supervised by physiotherapists with an interest in the shoulder. Outcomes assessment was undertaken at a minimum of 12 months by a registrar or physiotherapist who was not part of the treating team. Pre-op data collection included; range of motion, pain score, Oxford shoulder score (OSS), assessment of muscle atrophy on MRI. Data collection was completed in 15 patients. The mean age was 62 yrs (56 – 75). The mean pre-op OSS was 22, improving to a mean of 43. The range of motion and pain score improved. There were no intra-operative complications. One patient required a second surgery for evacuation of a haematoma at 10 days post op. One patient had an obvious re-tear at 4 months. Open rotator cuff repair with synthetic Kuff patch augmentation for chronic degenerative tears appears worthwhile when assessed at 12 months and they continuous to improve even at 18 months. This treatment method may be a useful option for patients > 70 years old.
We report the case of an 80-year-old woman treated by palliative knee arthrodesis for metastases of the proximal left tibia secondary to bladder carcinoma, using percutaneous femortibial intramedullary arthrodesis nailing. The technique provided a simple alternative to massive allografting, total joint prosthesis or amputation, with advantages of low morbidity, short operating time, minimal blood loss, immediate ambulation and weight bearing, relief of pain, restoration of independence, and ease of nursing care. We are satisfied with the procedure of percutaneous femorotibial intramedullary nailing as a palliative treatment of proximal tibial metastases in an elderly patient.
The outcome of complex acetabular reconstruction was evaluated in twenty-one patients who were confined to a wheelchair or bed because of pain from acetabular metastases. Reconstruction rings were used where bone loss exceeded 50% of the acetabulum. Six roof reinforcement-rings, eight ilioischial-rings and eight
Total hip arthroplasty (THA) is a physically demanding procedure where the surgeon is subject to fatigue with increased energy expenditure comparable to exercise[1]. Robotic technologies have been introduced into operating rooms to assist surgeons with ergonomically challenging tasks and to reduce overall physical stress and fatigue[2]. Greater exposure to robotic assisted training may create efficiencies that may reduce energy expenditure[3]. The purpose of this study was to assess surgeon energy expenditure during THA and perceived mental and physical demand. 12 THAs (6 cadavers) randomized by BMI were performed by two surgeons with different robotic assisted experience. Surgeon 1 (S1) had performed over 20 robotic assisted THAs on live patients and Surgeon 2 (S2) had training on 1 cadaver with no patient experience. For each cadaver, laterality was randomized and manual total hip arthroplasty (MTHA) was performed first on one hip and robotic assisted total hip arthroplasty (RATHA) on the contralateral hip. A biometric shirt collected surgeon data on caloric energy expenditure (CEE) throughout acetabular reaming (AR) and acetabular implantation (AI) for each THA procedure. Surgeon mental and physical demand was assessed after each surgery. Scores were reported from 1–10, with 10 indicating high demand. A paired sample t-test was performed between MTHA and RATHA within each surgeon group with a confidence interval of (α =0.05).Introduction
Methods
Pathologic fractures about the hip are an uncommon, but increasingly prevalent, clinical scenario encountered by orthopaedic surgeons. These fractures about the hip usually necessitate operative management. Life expectancy must be taken into account in management, but if survivorship is greater than 1 month, operative intervention is indicated. Determination must be made prior to operative management if the lesion is a solitary or metastatic lesion. Imaging of the entire femur is necessary to determine if there are other lesions present. Bone lesions that have a large size, permeative appearance, soft tissue mass, and rapid growth are all characteristics that suggest an aggressive lesion. Biopsy of the lesion in coordination with the operative surgeon should be conducted if the primary tumor is unknown. Metastatic disease is much more common than primary tumors in the adult population. Many metastatic fractures in the intertrochanteric region, and all fractures in the femoral neck and head are an indication for hemiarthroplasty or total hip arthroplasty. Cemented femoral implants are generally indicated. This allows immediate weight bearing in a bone with compromised bone stock, thus reducing the risk of peri-operative fractures. Additionally, patients are often treated with radiation and/or chemotherapy, which may prevent proper osseointegration of an ingrowth femoral component. Highly porous ingrowth shells have been shown to provide reliable and durable fixation even in these situations. Management of a periacetabular pathologic fracture, particularly resulting in a pelvic discontinuity is a particularly challenging situation. Use of a highly porous acetabular component combined with an acetabular cage, a custom acetabular component, a cemented
The management of scapho-lunate (SL) instability remains controversial. Since 2001, the senior author has used a modified Brunelli tenodesis to achieve soft tissue stabilization in patients presenting with dynamic or static SL instability. From 2001 to 2009, 13 patients were prospectively studied. All patients complained of painful clicking in the wrist, inability to use the wrist for loading activities, and all had a positive scaphoid shift test (Kirk Watson). Wrist arthroscopy was performed to confirm the diagnosis and to confirm the absence of degenerative change in all cases. Data collection pre-operatively included, range of motion, grip strength, DASH score and pain score. All patients had wrist immobilisation in a forearm cast for six weeks post operatively. Physiotherapy commenced at that stage and clinical assessment was performed at 3 months, six months and 12 months post surgery. Patients were discharged from follow-up after 12 months. A significant improvement in grip strength and DASH score was documented at the 12 month post operative assessment. The range of wrist flexion was decreased in all patients. The majority returned to their original employment. All patients reported that their wrist instability symptoms were improved. Scapho-lunate ligament reconstruction using a split flexor carpi radialis tendon graft to achieve soft tissue stabilization, provided satisfactory results in patients with chronic SL instability. Improvement in DASH score and grip strength were documented at one year follow-up.Conclusion
The failure rate of Total Hip Replacement (THR) has been shown to be strongly influenced by the nature of the articulating interfaces, with Metal-on-Metal (MoM) articulations having three times the failure rate of Metal-on-Polyethylene (MoP) components. It has been postulated that this observation is related to edge wear and increased bearing torque of large MoM heads, which would lead to increased loading and wear at the head taper junction and, subsequently, to the release of metal ions and corrosion products. This suggests that taper wear and corrosion should not be as prevalent in large head MoP implants as in large head MoM implants. This study was undertaken to test the hypotheses that: (i) MoM implants exhibit higher rates of corrosion and fretting at the head taper junction than MoP implants, and that (ii) the severity of corrosion and fretting is greater in components of larger head diameter. Our study included 90 modular implants (41 MoM; 49 MoP) retrieved during revision hip arthroplasties performed between 1992 and 2012. Only retrievals with head diameters greater than 32 mm were included, and trunnion sizes ranged from 10/12 mm to 14/16 mm with 12/14 mm being the most common size. The stem trunnion and head taper surfaces were examined under stereomicroscope by a single observer. Each surface was scored for both corrosion (using a modified Goldberg scoring system) and fretting (using the standard Goldberg scoring system). For both the trunnion and head tapers, the student's t-test was used to determine if differences exist in the severity of corrosion or fretting between the MoM and MoP groups and between different head sizes of the same articulation type.Introduction
Materials and Methods
Titanium and its alloys are attractive biomaterials attributable to their desirable corrosion, mechanical, biocompatibility and osseointegration properties. In particular, β – titanium alloys like the TMZF possess other advantages such as its lower modulus compared to Ti6Al4V alloy. This reduces stress shielding effect in Total Hip Arthroplasty (THA) and the replacement of V in the Ti6Al4V alloy, eliminates A ball-on-flat configuration was utilised in this study to achieve a Hertzian point contact for CoCrMo – Ti6Al4V and CoCrMo – TMZF material combinations. These were assessed at a fretting displacement of ±50 µm at an initial contact pressure of 1 GPa. Each fretting test lasted 6000 cycles at a frequency of 1 Hz. A two-electrode cell set-up was used to monitor Introduction
Method
The orthopaedic surgeon is often consulted to manage pathologic fractures due to metastatic disease, even though he or she may not be an orthopaedic oncologist. A good understanding of the principles of management of metastatic disease is therefore important. The skeleton remains a common site for metastasis, and certain cancers have a predilection for bone, namely, tumors of the breast, prostate, lung, thyroid, and kidney. Myeloma and lymphoma also often involve bone. The proximal femur and pelvis are most commonly affected, so we will focus on those anatomic sites. The patient may present with pain and impending fracture, or with actual fracture. Careful preoperative medical optimization is recommended. If the lesion is solitary, or the primary is unknown, the diagnosis must be made by a full workup and biopsy before definitive treatment is planned. For patients with known metastasis (the most common situation), the options for treatment of pathologic lesions of the proximal femur generally center on internal fixation versus prosthetic replacement. Patients with breast or prostate metastasis can live for several years after pathologic fracture, so constructs must be relatively durable. If fixation is chosen, it must be stable enough to allow full weight bearing, since the overwhelming majority of pathologic fractures will never heal. In general, long constructs are chosen to protect the entire length of the bone. Nails should protect the femoral neck as well, so cephalomedullary devices are typically chosen. Megaprostheses can be useful in situations where bony destruction precludes stable internal fixation. Postoperative radiation is recommended after wound healing. Acetabular involvement typically requires reinforcement rings or cement augmentation with the
Blood transfusion requirement in shoulder surgery has been reported from 8.1% to up to 15%. Our observation was that blood transfusion rarely required after open shoulder surgery. We therefore decided to conduct a retrospective case notes study to look at the crossmatch-transfusion ratio for shoulder surgery. A total of 211 patients were included in the study. Results were analysed using paired T-test from SPSS (15.0). There were 63 elective procedures and 148 trauma procedures during that period. Ten patients (4.8%) required intra-operative or post operative transfusion. Crossmatch-transfuison ratio was 21. There should be a clear equation between crossmatch and its use, intra-operatively and post operatively. This study highlighted unnecessary cross-matching for shoulder operations which puts extra pressure on the laboratory staff, the blood bank and also has financial implications.
At present patients who require shoulder hemiarthroplasty in our unit routinely have two units of blood cross matched pre-operatively. Our observation was that blood transfusion rarely required after open shoulder surgery. We therefore decided to look at the crossmatch-transfusion ratio for the following procedures in our department; elective shoulder hemiarthroplasty, reverse total shoulder replacement, open rotator cuff repair, shoulder hemi-arthroplasty for trauma, open reduction and internal fixation of proximal humeral fractures. We undertook a retrospective review of all such patients during the period of 2002 to 2005. All trauma and elective surgery included. Hospital notes were analysed to include age, sex, pre operative haemoglobin level, blood transfusion intra-operatively and post-operatively. A total of 211 patients were included in the study. There were 63 elective procedures and 148 trauma procedures during that period. No patient required intra-operative or post operative transfusion. Three patients who required transfusions post operatively, due to other associated injury (liver laceration x1, spleen injuries x 2) were excluded from the study. Crossmatch-transfuison ratio was >
2. There should be a clear equation between cross-match and its use, intra-operatively and post operatively. This study highlighted unnecessary cross-matching for shoulder operations in our unit which puts extra pressure on the laboratory staff, the blood bank and also has financial implications. We recommend, Standardised approach for pre-operative cross match practise, pre-operative group and screen to detect atypical antibodies and efficient hospital pathology services, to provide blood for transfusion within specified time, for atypical antibody negative blood, should it require.