Aims. The conversion of previous hip fracture surgery to total hip arthroplasty (CTHA) can be surgically challenging with unpredictable outcomes; reported complication rates vary significantly. This study aimed to establish the medium-term survival and outcomes of CTHA performed following a previous hip fracture surgery. Methods. All CTHAs performed at our tertiary orthopaedic institution between January 2008 and January 2020 following previous ipsilateral hip fracture surgery were included. Patients were followed up clinically using Oxford Hip Scores (OHS), and radiologically until death or revision surgery. Postoperative complications, radiological implant failure, and indications for revision surgery were reviewed. Results. A total of 166 patients (167 hips) were included in the study, with a mean age of 71 years (42 to 99). Of these, 113 patients (67.7%) were female. CTHA followed cannulated screw fixation in 75 cases, hemiarthroplasty in 18, dynamic
Femoral head collapse due to avascular necrosis (AVN) is a relatively rare occurrence following intertrochanteric fractures; however, with over thirty-thousand intertrochanteric fractures per year in England and Wales alone, and an incidence of up to 1.16%, it is still significant. Often patients are treated with a
Objectives. Fractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix. Methods. Devices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm. 3. , 0.16 g/cm. 3. and 0.24 g/cm. 3. ). Each torsion test comprised a steady ramp of 1°/minute up to an angular displacement of 10°. Results. The deployable crucifix design (X-Bolt), was more torsionally stable, compared to both the dynamic hip screw (DHS, p = 0.008) and helical blade (DHS Blade, p= 0.008) designs in bone substitute material representative of osteoporotic bone (0.16 g/cm. 3. polyurethane foam). In 0.08 g/cm. 3. density substrate, the crucifix design (X-Bolt) had a higher resistance to torsion than the screw (DHS, p = 0.008). There were no significant differences (p = 0.101) between the implants in 0.24 g/cm. 3. density bone substitute. Conclusions. Our findings indicate that the clinical standard proximal fracture fixator design, the screw (DHS), was the least effective at resisting torsional load, and a novel crucifix design (X-Bolt), was the most effective design in resisting torsional load in bone substitute material with density representative of osteoporotic bone. At other densities the torsional stability was also higher for the X-Bolt, although not consistently significant by statistical analysis. Cite this article: J. D. Gosiewski, T. P. Holsgrove, H. S. Gill. The efficacy of rotational control designs in promoting torsional stability of
There is continued debate as to whether cemented or cementless implants should be utilized in particular cases based upon chronological age. This debate has been rekindled in the UK and other countries by directives mandating certain forms of acetabular and femoral component fixation based exclusively on the chronological age of the patient. This editorial focuses on the literature-based arguments to support the use of cementless total hip arthroplasty (THA), while addressing potential concerns surrounding safety and cost-effectiveness. Cite this article:
A fluoroscopic based computer enhancement system was designed for accurate insertion of guide wires for
Intra-operative Tip-Apex Distance (TAD) estimation optimises dynamic hip screw (DHS) placement during
The ultimate goal of surgery for acetabular fractures is hip joint preservation for the rest of the patient’s life. However, besides Letournel’s series, long term survi-vorship in this predominantly young patient group has never been published in a very large series. The aim of this study was to determine the cumulative 20-year sur-vivorship of the
The placement of the guide wire in the dynamic hip screw operation can be a challenging task to the trauma surgeon. Complications can arise related to incorrect guide wire entry point, making wrong tracks, or even accepting an unsatisfactory lag screw placement. Insisting to optimise the guide wire position can lead to increase in operation and radiation exposure times. A new non-invasive technique is described to assist precision placement of the guide wire in the dynamic
Failure of intertrochanteric fracture fixation often occurs in patients, who have poor bone quality, severe osteoporosis, or unstable fracture patterns. Hip arthroplasty is a good replacement procedure even though it involves technical issues such as implant removal, bone loss, poor bone quality, trochanteric nonunion and difficulty of surgical exposure. The purpose of this study is to evaluate the outcomes of total hip arthroplasty (THA) as the replacement for failed fixation of intertrochanteric fractures of the femur. 203 patients of failed intertrochanteric fractures between April 2009 and October 2014 were included in the study. All of them underwent total hip arthroplasty through direct lateral approach. 150 patients were male (73.8%) and 53 patients (26.1%) were female and the mean of age was 59.02±10.34 years old (range: 56–90 years). The indications of the failure were nail cut out in 174 (85.7%), non-union in 15 (7.3%), plate failure in 14 cases (6.8%). One patient underwent two-stage protocol due to infection. We evaluated the possible clinical and radiological complications and measured functional outcome with modified Harris hip score (MHHS). We used cementless cup in nearly all of patients (95.2%), cementless long stem in 88.1% of patients.Introduction
Patients and Methods
Aim: To compare the acute haemoglobin level drop following
Quality of reduction was assessed as per Sernbo. Good, if alignment was normal on AP and maximum 20 degrees angulation on lateral radiograph and less than 4mm of displacment of any fragment. To be labelled acceptable, a reduction had to meed the criteria of a good reduction with respect to either alignement or displacement, but not both. A poor reduction met neither.
The use of the dynamic hip screw is common practice for the fixation of intertrochanteric fractures of the femur. The success of this procedure requires accurate guide wire placement. This can prove difficult at times and can result in repeated attempts leading to longer operating time, multiple tracks and more importantly greater radiation exposure to both patient and operating staff. We hypothesised that rather than using the standard anterior-posterior projected image (Figure 1) of a proximal femur, rotating the intensifier image (Figure 2) so that the guide wire appears to pass vertically makes it easier to visualise the projected direction of the guide wire. Fifty Specialist Registrars, thirty participating in the London hip meeting 2009, ten from Oxford and ten from Northern deanery orthopaedic rotations were involved in the study. They were presented with standard AP and rotated images of the femoral neck on paper using 135 degree template to replicate the DHS guide. The participants were asked to mark the entry point on the intertrochanteric area of femur on the image where they would have placed the guide wire. They did this on both standard AP and rotated images aiming for the centre of the head of the femur. Fig. 1 Standard AP image Fig. 2 Rotated imageIntroduction
Methods
Internal fixation of pertrochanteric fractures is evolving as newer implants are being developed. Proximal Femoral Nail Antirotation (PFNA) is a recently introduced implant from AO/ASIF designed to compact the cancellous bone and may be particularly useful in unstable and osteoporotic hip fractures. This study is a single and independent centre experience of this implant used in management of acute hip fractures. 68 patients involving 68 PFNA nailing procedures done over a period of 2 years (2007–09) were included in the study. Average follow-up period of patients was 1 year. AO classification for trochanteric fractures was used to classify all the fractures. Radiological parameters including tip-apex distance and neck shaft angle measurement were assessed.Introduction
Methods
Aims. Total hip arthroplasty (THA) is considered the preferred treatment for displaced proximal femoral neck fractures. However, in many countries this option is economically unviable. To improve outcomes in financially disadvantaged populations, we studied the technique of concomitant valgus hip osteotomy and operative fixation (VOOF). This prospective serial study compares two treatment groups: VOOF versus operative fixation alone with cannulated compression screws (CCSs). Methods. In the first series, 98
Majority of osteoporosis related fractures are treated surgically using metallic fixation devices. Anchorage of fixation devices is sometimes challenging due to poor osteoporotic bone quality that can lead to failure of the fracture fixation. Using a rat osteoporosis model, we employed neutron tomography and histology to study the biological effects of implant augmentation using an isothermally setting calcium sulphate/hydroxyapatite (CaS/HA) biomaterial with synthetic HA particles as recruiting moiety for systemically administered bisphosphonates. Using an osteoporotic sawbones model, we then provide a standardized method for the delivery of the CaS/HA biomaterial at the bone-implant interface for improved mechanical anchorage of a lag-screw commonly used for
The incidence of hip fractures in the elderly is increasing. Minimally displaced and un-displaced hip fractures can be treated with either internal fixation or hemiarthroplasty. The aim was identifying the revision rate of internal fixation and hemiarthroplasty in patients 60 years or older with Garden I or II hip fractures and to identify risk factors associated with each method. A retrospective analysis was conducted from 2 Major Trauma Centres and 9 Trauma Units between 01/01/2015 and 31/12/2020. Patients managed conservatively, treated with a total hip replacement and missing data were excluded from the study. 1273 patients were included of which 26.2% (n=334) had cannulated
Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. Methods. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty). Results. Eight female (29%) and 20 male trainees (71%), mean age 29.4 years, performed 317 DHS operations and 243 hemiarthroplasties during ten months of follow-up. Primary analysis was a random effect model with surgeon-level fixed effects of patient condition, patient age, and surgeon experience, with a random intercept for surgeon. Under the intention-to-treat principle, for hemiarthroplasty there was better implant position in favour of cadaveric training, measured by leg length discrepancy ≤ 10 mm (odds ratio (OR) 4.08 (95% confidence interval (CI) 1.17 to 14.22); p = 0.027). There were significantly fewer postoperative blood transfusions required in patients undergoing hemiarthroplasty by cadaveric-trained compared to standard-trained surgeons (OR 6.00 (95% CI 1.83 to 19.69); p = 0.003). For DHS, there was no significant between-group difference in implant position as measured by tip-apex distance ≤ 25 mm (OR 6.47 (95% CI 0.97 to 43.05); p = 0.053). No between-group differences were observed for any secondary clinical outcomes. Conclusion. Trainees randomized to additional cadaveric training performed
Solid organ transplant (SOT) recipients present an increased medical risk; however, few studies analyze the outcomes of these patients undergoing hip fracture surgery. This study aimes to determine the incidence of hip fracture in SOT patients and to compare the outcomes of SOT patients with matched non-SOT controls after
Lag screw cut-out is a serious complication of dynamic
Appropriate surgical management of hip fractures has major clinical and economic consequences. Recently IMN use has increased compared to SHS constructs, despite no clear evidence demonstrating superiority of outcome. We therefore set out to provide further evidence about the clinical and economic implications of implant choice when considering