Over time, the locking mechanism of Modular Universal Tumour and Revision System (MUTARS) knee arthroplasties changed from polyethylene (PE) to polyether-ether-ketone Optima (PEEK) and metal-on-metal (MoM) in an attempt to reduce the risk of mechanical failure. In this study, we aimed to assess the cumulative incidence of locking mechanism revision for symptomatic instability by type of material, and assess potential associated risk factors. The MUTARS Orthopaedic Registry Europe was used for a retrospective review of 316 patients (54% male (n = 170), median age 44 years (IQR 23 to 61)) who underwent a MUTARS knee arthroplasty for oncological indications between December 1995 and January 2023. The minimum follow-up was 12 months, and the median follow-up was 7.9 years (IQR 3.3 to 13.0). A competing risk model was used to estimate the cumulative incidence of first locking mechanism revision with death and revision for any other reason as competing events. Possible risk factors were assessed employing a univariate cause-specific hazards regression model.Aims
Methods
Aims: The knee is the commonest articular location in osteosarcoma (OS). We study the complications in limb salvage due to OS in
A patient in his thirties developed synovitis with grade 4 chondrolysis and a stiff knee with a fixed flexion deformity between three and six years following PLC and PCL reconstruction using LARS (Ligament Augmentation and Reconstruction System, Corin). There was histologic evidence of foreign body reaction, the knee was painful, swollen and stiff. We did not use any further LARS ligaments for soft tissue reconstructions of the kneein our practice. We commenced a recall programme for all 83 patients patients who underwent a soft tissue
Anterior cruciate ligament (ACL) and multiligament knee (MLK) injuries increase the risk of development of knee osteoarthritis and eventual need for total knee arthroplasty (TKA). There is limited data regarding implant use and outcomes in these patients. The aim of this study was to compare the use of constrained implants and outcomes among patients undergoing TKA with a history of prior knee ligament reconstruction (PKLR) to a matched cohort of patients undergoing TKA with no history of PKLR. All patients with history of ACL or MLK reconstruction who underwent TKA between 2007–2018 were identified in a single institution registry. A matched cohort was identified based on patient age, body mass index (BMI), sex, and year of surgery. The primary outcome measure was utilization of constrained implants. Secondary outcomes included rates of deep vein thrombosis (DVT), pulmonary embolism (PE), infection, postoperative transfusion, postoperative knee range of motion (ROM), revision surgery, and patient reported outcomes (Knee Injury and Osteoarthritis Outcome Score for joint replacement (KOOS, JR).Introduction
Methods
How to position a unicompartmental knee replacement (UKR) remains a matter of debate. We suggest an original technique based on the intra-operative anatomic and dynamic analysis of the operated knee by a navigation system, with a patient-specific reconstruction by the UKR. The goal of the current study was to assess the feasibility of the new technique and its potential pitfalls. 100 patients were consecutively operated on by implantation of a UKR with help of a well validated, non-image based navigation system, by one single surgeon. There were 41 men and 59 women, with a mean age of 68 years (range, 51 to 82 years). After data registration, the navigation system provided the dynamic measurement of the coronal tibio-femoral mechanical angle in full extension. The reducibility of the deformation was assessed by a manually applied torque in the valgus direction. The patient-specific analysis was based on the following hypotheses: 1) The normal medial laxity in full extension is 2° (after previous studies), 2) there was no abnormal medial laxity (which may be routinely accepted for varus knees) and 3) the total reducibility is the sum of the patient's own medial laxity and of the bone and cartilage loss. We assumed that the optimal correction may be calculated by the angle of maximal reducibility, less 2° to respect the normal medial laxity. The bone resections were performed accordingly to this calculated goal. No ligamentous balance or retension was performed. The fine tuning of the remaining laxity was performed by adapting the height of polyethylene component with a 1 mm step. The final measurements (coronal tibio-femoral angle in full extension and medial laxity in full extension) were performed with the navigation system after the final components fixation. The implantation had to fulfill these two parameters: optimal correction as defined previously, and a 2 ± 1° of medial laxity.Objectives
Methods
The presence of an unremovable cemented tibial nail presents a unique challenge for limb salvage reconstructions utilizing a rotating hinge knee. All manufacturers’ designs except Link America incorporate a vertically-oriented rotational channel in the proximal tibia to provide the housing for a rotational axis stem. Such channel placement may be impossible in patients with pre-existing tibial hardware that obliterates the proximal tibial intramedullary canal. The Link America design utilizes a superiorly-projecting rotational stem that articulates with a housing located on the rotational yoke component; however it requires an intramedullary tibial stem for component stabilization. Thus all currently available rotating hinge knees require placement of a stem or a stem equivalent into the tibial intramedullary canal. We describe a limb salvage case employing a Link America rotating hinge knee with a tibial component incorporating a custom hollow stem in a patient with an unremovable centralized, straight, cemented tibial nail. This reconstruction was required following an intra-articular fracture of a successfully incorporated massive proximal tibial osteoarticular allograft. The allograft had been implanted seven years previously following resection of a proximal tibia osteosarcoma. This custom device allowed a relatively simple limb salvage reconstruction with good results and only a two day hospital stay. This custom hollow-stemmed device allowed limb salvage in a situation that otherwise would have required either an amputation or resection of a healed tibial allograft that had successfully incorporated, replacing approximately 50% of the length of the tibia shaft. While rarely required, such an implant can allow a relatively simple and straight-forward functional salvage of an extremity in those patients whose only other choices for limb salvage include much more extensive bone resections and complex reconstructions. The potential for subsequent articular level failure should be considered whenever utilizing an osteoarticular allograft. A cemented, retrograde inserted, intramedullary nail can provide reliable internal fixation of such an allograft. If such fixation is selected, a straight intramedullary nail (as in this case) should be utilized, so that the intramedullary device is centered in the proximal tibia. This will allow for future revision to a total knee with a hollow stemmed tibial component should the need arise.
The anterolateral ligament (ALL) is considered as an important stabilizer of the knee joint. This ligament prevents anterolateral subluxation of the proximal tibia on the femur when the knee is flexed and internally rotated. Injury of the ALL was not investigated in patients with knee dislocation. The aim of the current research is to study the prevalence and characteristics of ALL injury in dislocated knees. A retrospective review of charts and radiological images was done for patients who underwent multiligamentous
Objectives. Congenital cruciate ligament deficiency is a rare condition that may occur in isolation or in association with longitudinal limb deficiencies such as fibular hemimelia or proximal femoral focal deficiency. Often anomalies of the menisci and their attachments can be very abnormal and impact on surgical management by standard techniques. Arthroscopic surgical
While surgeon-industry relationships in orthopaedics have a critical role in advancing techniques and patient outcomes, they also present the potential for conflict of interest (COI) and increased risk of bias in surgical education. Consequently, robust processes of disclosure and mitigation of potential COI have been adopted across educational institutions, professional societies, and specialty journals. The past years have seen marked growth in the use of online video-based surgical education platforms that are commonly used by both trainees and practicing surgeons. However, it is unclear to what extent the same COI disclosure and mitigation principles are adhered to on these platforms. Thus, the purpose of the present study was to evaluate the frequency and adequacy of potential COI disclosure on orthopaedic online video-based educational platforms. We retrospectively reviewed videos from a single, publicly-accessible online peer-to-peer orthopaedic educational video platform (VuMedi) that is used as an educational resource by a large number of orthopaedic trainees across North America. The 25 highest-viewed videos were identified for each of 6 subspecialty areas (hip reconstruction,
Introduction. The purpose of the study was to determine access to and, ability to use telemedicine technology in an adult hip and
OSSTEC is a pre-spin-out venture at Imperial College London seeking industry feedback on our orthopaedic implants which maintain bone quality in the long term. Existing orthopaedic implants provide successful treatment for knee osteoarthritis, however, they cause loss of bone quality over time, leading to more dangerous and expensive revision surgeries and high implant failure rates in young patients. OSSTEC tibial implants stimulate healthy bone growth allowing simple primary revision surgery which will provide value for all stakeholders. This could allow existing orthopaedics manufacturers to capture high growth in existing and emerging markets while offering hospitals and surgeons a safer revision treatment for patients and a 35% annual saving on lifetime costs. For patients, our implant technology could mean additional years of quality life by revising patients to a primary TKA before full revision surgery. Our implants use patent-filed additive manufacturing technology to restore a healthy mechanical environment in the proximal tibia; stimulating long term bone growth. Proven benefits of this technology include increased bone formation and osseointegration, shown in an animal model, and restoration of native load transfer, shown in a human cadaveric model. This technology could help capture the large annual growth (24%) currently seen in the cementless
Acute total knee dislocations are uncommon injuries for which some surgeons use artificial ligaments as their choice of graft for reconstruction. The goal of this study is to evaluate on a short and long term basis the stability and function of the LARS reconstructed knee. Flexion ROM was the only parameter which showed significant difference (p<
0.05) between subgroups. Therefore this treatment option for dislocated
Introduction. Although total knee replacement became a widespread procedure for the purpose of
Much is made of the role of good judgment in the reduction of error, although it is undeniable that error has a role in the development of such judgment. Hence retrospectives from those with experience have merit if we can assume they have introspection and insight as well. In this panel discussion we will explore the experience of a group of renowned surgeons in the field of hip and
To evaluate the value of the use of massive prostheses in periprosthetic infections both in one stage and two stages procedures. Between 2008 and 2014, 236 revisions for PJI had been performed in our hospital by the same surgeon. For the most complex cases, we decided to introduce megaprostheses in our practice in 2011. We report a prospective series of 33 infected patients treated between 2011 and the end of 2014, 14 male and 19 female with on average 67.9 years old (38–85) Infection involved TKA in 22 cases (17 TKA revisions, 4 primary TKA), THA in 9 cases (6 revisions, 3 primary THA), a femoral pseudo-arthrosis with posttraumatic gonarthrosis in one case and a septic humeral pseudoarthrosis in one case. We used a total femoral component for two patients: the first one for a hip PJI with extended diaphyseal bone loss and multiples sinus tracks, and the second one for a massive infected knee prosthesis used in a
Purpose: This study was carried out in order to assess the results of reconstruction of a deficient extensor mechanism in the presence of total knee replacement using Connective Tissue Prosthesis (CTP). Methods &
results: The CTPs are available as flat tapes constructed from polyester in an open weave structure. They were used to reinforce and reconstruct the extensor mechanism which was deficient in three patients who had undergone total knee replacement or were about to undergo total knee replacement. Two cases had extensor mechanism deficiency as a complication following total knee replacement while the third case had extensor mechanism deficiency at the time of the primary
Full-thickness burns around the knee can involve the extensor mechanism. The gastrocnemius flap is well described for soft tissue reconstruction around the knee. We describe a method where a Whichita Fusion Nail¯ knee arthrodesis, combined with a medial gastrocnemius muscle flap was used to salvage the knee and preserve the lower leg following a full-thickness contact burn. The gastrocnemius flap for wound coverage of an open knee joint was originally described in 1970 and remains the workhorse for soft tissue
The purpose of this study was to evaluate the outcome of posterior cruciate ligament (PCL) reconstruction with a double tunnel technique, using prospective pre &
post-operative functional scoring and clinical evaluation. We reviewed those patients who underwent PCL reconstruction between October 2001 and October 2006. 24 patients were identified, 23 male and 1 female. Mean age 30.1 years (range 17–43). Mean follow up 56 months (range 29–86). The commonest mode of injury was football. 3 patients had isolated PCL injuries, 21 had concomitant knee ligament injuries which were treated surgically at the same operation. Patients were prospectively scored pre-operatively and at 3, 6, 12 &
24 months post-op using the Lysholm, IKDC 2000 &
KOOS scoring systems. These scores were compared to an injury matched control group who underwent comparable knee ligament reconstructions, but who had intact PCL’s. The knee scores showed a significant improvement in all PCL reconstructed patients post-op (p<
0.05). However, significant differences were found between the PCL reconstructed and PCL intact groups. Both groups had high return to employment and return to sports rates. We describe our method of double tunnel reconstruction. Conclusions: PCL injury is usually associated with concomitant soft tissue knee injuries. PCL deficiency contributes significantly to the morbidity of the multiple ligament injured
Aim. The use of megaprostheses for