Aims. There are concerns regarding nail/medullary canal mismatch and initial stability after cephalomedullary nailing in unstable pertrochanteric fractures. This study aimed to investigate the effect of an additional anteroposterior blocking screw on fixation stability in unstable pertrochanteric fracture models with a nail/medullary canal mismatch after short cephalomedullary nail (CMN) fixation. Methods. Eight finite element models (FEMs), comprising four different femoral diameters, with and without blocking screws, were constructed, and unstable intertrochanteric fractures fixed with short CMNs were reproduced in all FEMs. Micromotions of distal shaft fragment related to proximal fragment, and stress concentrations at the nail construct were measured. Results. Micromotions in FEMs without a blocking screw significantly increased as nail/medullary canal mismatch increased, but were similar between FEMs with a blocking screw regardless of mismatch. Stress concentration at the nail construct was observed at the junction of the nail body and lag screw in all FEMs, and increased as nail/medullary canal mismatch increased, regardless of blocking screws. Mean stresses over regions of interest in FEMs with a blocking screw were much lower than regions of interest in those without. Mean stresses in FEMs with a blocking screw were lower than the yield strength, yet mean stresses in FEMs without blocking screws having 8 mm and 10 mm mismatch exceeded the yield strength. All mean stresses at distal locking screws were less than the yield strength. Conclusion. Using an additional anteroposterior blocking screw may be a simple and effective method to enhance fixation stability in unstable pertrochanteric fractures with a large nail/medullary canal mismatch due to osteoporosis. Cite this article: Bone Joint Res 2022;11(3):152–161


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 6 - 6
14 Nov 2024
Karjalainen L Lähdesmäki M Ylitalo A Eskelinen A Mattila VM Repo J
Full Access

Background. Cephalomedullary nails are widely used for fixation of unstable pertrochanteric fractures. In 2018, the Depuy Synthes Trochanteric Fixation Nail - Advanced (TFNA) implant was introduced at a level I academic trauma center. Thereafter, the TFNA swiftly replaced the older implant models used at the time. Subsequently, clinical concerns were raised about the use of the TFNA due to reports of nail breakage. The purpose of this study was to investigate whether the concerns raised about the performance of the TFNA were valid and to assess long-term outcomes. Methods. The data consisted of 2397 patients who had undergone a proximal femoral hip fracture procedure between 2014 and 2020. Data were handpicked from patient records. TFNA was compared with TFN, PFNA, Gamma3, and Intertan regarding nail breakage, breakage time and long-term outcomes. Results. After exclusion a total of 23/1667 (1.4%) nails broke during the follow-up period. The TFNA broke the most often with 15 cases (2.0%), followed by the Gamma3 with five cases (1.1 %) and the PFNA with three cases (1.3%). Overall, the mean (SD) nail breakage time was 233 (147.8) days. However, for the TFNA, PFNA, and Gamma3, the mean breakage times were 176.8 days (109.9), 419 days (108.6), and 291.8 (153.4), respectively. In cox regression analysis we observed significant reduction in nail breakage when using PFNA with adjusted hazard risk of 0.081 [95% Ci, 0.011-0.576, p=0.011]. Conclusions. In our data, the TFNA had a slightly higher risk for nail breakage when compared to the PFNA and the Gamma3, with a risk difference of 0.7% and 0.9%, respectively. On average, the TFNA broke nearly four months earlier than the Gamma3 and more than eight months earlier than the PFNA. It should be noted, however, that implant breakage is a relatively infrequent complication


Bone & Joint Research
Vol. 9, Issue 12 | Pages 840 - 847
1 Dec 2020
Nie S Li M Ji H Li Z Li W Zhang H Licheng Z Tang P

Aims. Restoration of proximal medial femoral support is the keystone in the treatment of intertrochanteric fractures. None of the available implants are effective in constructing the medial femoral support. Medial sustainable nail (MSN-II) is a novel cephalomedullary nail designed for this. In this study, biomechanical difference between MSN-II and proximal femoral nail anti-rotation (PFNA-II) was compared to determine whether or not MSN-II can effectively reconstruct the medial femoral support. Methods. A total of 36 synthetic femur models with simulated intertrochanteric fractures without medial support (AO/OTA 31-A2.3) were assigned to two groups with 18 specimens each for stabilization with MSN-II or PFNA-II. Each group was further divided into three subgroups of six specimens according to different experimental conditions respectively as follows: axial loading test; static torsional test; and cyclic loading test. Results. The mean axial stiffness, vertical displacement, and maximum failure load of MSN-II were 258.47 N/mm (SD 42.27), 2.99 mm (SD 0.56), and 4,886 N (SD 525.31), respectively, while those of PFNA-II were 170.28 N/mm (SD 64.63), 4.86 mm (SD 1.66), and 3,870.87 N (SD 552.21), respectively. The mean torsional stiffness and failure torque of MSN-II were 1.72 N m/° (SD 0.61) and 16.54 N m (SD 7.06), respectively, while those of PFNA-II were 0.61 N m/° (SD 0.39) and 6.6 N m (SD 6.65), respectively. The displacement of MSN-II in each cycle point was less than that of PFNA-II in cyclic loading test. Significantly higher stiffness and less displacement were detected in the MSN-II group (p < 0.05). Conclusion. The biomechanical performance of MSN-II was better than that of PFNA-II, suggesting that MSN-II may provide more effective mechanical support in the treatment of unstable intertrochanteric fractures. Cite this article: Bone Joint Res 2020;9(12):840–847


Bone & Joint Open
Vol. 5, Issue 6 | Pages 457 - 463
2 Jun 2024
Coviello M Abate A Maccagnano G Ippolito F Nappi V Abbaticchio AM Caiaffa E Caiaffa V

Aims. Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail. Methods. A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value. Results. A total of 98 of the 112 patients met the inclusion criteria. Overall, 65 patients were female (66.3%), the mean age was 83.23 years (SD 7.07), and the mean follow-up was 378 days (SD 36). Cut-out was observed in five patients (5.10%). The variables identified by univariate analysis with p < 0.05 were included in the multivariate logistic regression model were screw placement and TAD. The TAD was significant with an odds ratio (OR) 5.03 (p = 0.012) as the screw placement with an OR 4.35 (p = 0.043) in the anteroposterior view, and OR 10.61 (p = 0.037) in the lateral view. The TAD threshold value identified was 29.50 mm. Conclusion. Our study confirmed the risk factors for cut-out in the double-screw nail are comparable to those in the single screw. We found a TAD value of 29.50 mm to be associated with a risk of cut-out in double-screw nails, when good fracture reduction is granted. This value is higher than the one reported with single-screw nails. Therefore, we suggest the role of TAD should be reconsidered in well-reduced fractures treated with double-screw intramedullary nail. Cite this article: Bone Jt Open 2024;5(6):457–463


Bone & Joint Open
Vol. 2, Issue 8 | Pages 599 - 610
1 Aug 2021
Hothi H Bergiers S Henckel J Iliadis AD Goodier WD Wright J Skinner J Calder P Hart AJ

Aims. The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices. Methods. We collected ten nails removed from six patients, together with patient clinical data and plain radiograph imaging. We performed macro- and microscopic analysis of all surfaces and graded the presence of corrosion using validated semiquantitative scoring methods. We determined the elemental composition of surface debris using energy dispersive x-ray spectroscopy (EDS) and used metrology analysis to characterize the surface adjacent to the extendable junctions. Results. All nails were removed at the end of treatment, having achieved their intended lengthening (20 mm to 65 mm) and after regenerate consolidation. All nails had evidence of corrosion localized to the screw holes and the extendable junctions; corrosion was graded as moderate at the junction of one nail and severe at the junctions of five nails. EDS analysis showed surface deposits to be chromium rich. Plain radiographs showed cortical thickening and osteolysis around the junction of six nails, corresponding to the same nails with moderate – severe junction corrosion. Conclusion. We found, in fully united bones, evidence of cortical thickening and osteolysis that appeared to be associated with corrosion at the extendable junction; when corrosion was present, cortical thickening was adjacent to this junction. Further work, with greater numbers of retrievals, is required to fully understand this association between corrosion and bony changes, and the influencing surgeon, implant, and patient factors involved. Cite this article: Bone Jt Open 2021;2(8):599–610


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 58 - 58
10 Feb 2023
Ramage D Burgess A Powell A Tangrood Z
Full Access

Ankle fractures represent the third most common fragility fracture seen in elderly patients following hip and distal radius fractures. Non-operative management of these see complication rates as high as 70%. Open reduction and internal fixation (ORIF) has complication rates of up to 40%. With either option, patients tend to be managed with a non-weight bearing period of six weeks or longer. An alternative is the use of a tibiotalocalcaneal (TTC) nail. This provides a percutaneous treatment that enables the patient to mobilise immediately. This case-series explores the efficacy of this device in a broad population, including the highly comorbid and cognitively impaired. We reviewed patients treated with TTC nail for acute ankle fractures between 2019 and 2022. Baseline and surgical data were collected. Clinical records were reviewed to record any post-operative complication, and post-operative mobility status and domicile. 24 patients had their ankle fracture managed with TTC nailing. No intra-operative complications were noted. There were six (27%) post-operative complications; four patients had loosening of a distal locking screw, one significant wound infection necessitating exchange of nail, and one pressure area from an underlying displaced fracture fragment. All except three patients returned to their previous domicile. Just over two thirds of patients returned to their baseline level of mobility. This case-series is one of the largest and is also one of the first to include cognitively impaired patients. Our results are consistent with other case-series with a favourable complication rate when compared with ORIF in similar patient groups. The use of a TTC nail in the context of acute, geriatric ankle trauma is a simple and effective treatment modality. This series shows acceptable complication rates and the majority of patients are able to return to their baseline level of mobility and domicile


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 40 - 40
1 May 2012
Devgan A
Full Access

Introduction. The free hand technique remains the most popular method for distal locking; however, radiation exposure and increased operative time is a major concern. In an endeavor to overcome this concern, a new technique of distal locking with nail over nail technique is evaluated. Method. Seventy patients with femoral diaphyseal fractures treated by intramedullary nailing were divided in two groups: distal locking either with free hand technique (group 1) or with nail over nail technique (group II). Group I contained 35 patients (21 males and 14 females) with average age of 44.14 years. Group II contained 35 patients (19 males and 16 females) with average age of 45.7 years. In group II 1.5 mm of over-reaming was performed to avoid the nail deformation while insertion. Results. Average diameter of the nails used in free hand technique was 11.3 mm and 10.7 mm in nail over nail technique. Precision problems in insertion of distal interlocking screws occurred in 9 screws in group I and 11 screws in group II. The average number of images/exposures taken by image intensifier for nail insertion, for distal locking, and for the complete procedure in group I, were respectively 25.8, 24.2, and 50.08 compared with 24.8, 4.1 and 28.9, respectively in group II. All second distal (more proximal) holes were inserted successfully in group II. The statistically extremely significant decrease in radiation by 44% in the average total number of images required during the complete procedure was observed in nail over nail technique versus free hand technique. Conclusion. This prospective study on distal locking of femoral intramedullary nails shows that radiation exposures to achieve equivalent precision are reduced with the nail over nail technique as compared with the free hand technique. It can also be used when an image intensifier is unavailable or goes out of order peroperatively. However, over reaming of 1.5mm is the key to the success of technique as it avoids nail deformation during insertion. Level of evidence: therapeutic level IV


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 334 - 334
1 Jul 2008
Singh S Vishwanathan K Patel M Daveshwar R
Full Access

Purpose of study: We aimed to compare the efficacy and effect of Ender nail and unreamed interlock nail in the management of Type I, II and IIIA fractures. Methods: 33 cases of open tibial shaft fractures in 32 patients were included in this prospective study. 17 tibial fractures were fixed with Ender nails introduced by antegrade approach and 16 tibial fractures were fixed with statically locked Interlocking nails. The mean follow-up period was 17.8 (6 to 32) months. The mean injury-surgery interval was 5.6 (1 to 16) days. Results: In the Ender nail group, the average union time for open fracture was 19.5 weeks and 18.3 weeks for Type-I fracture. In the Interlock nail group, the average union time for open fracture was 24.8 weeks and 23.8 weeks for Type-I fracture. Mann-Whitney test revealed significant difference between the two groups for the data described above. Treatment with either nails showed no significant difference in union time for Type-II and type-IIIA fractures. Ankle movement restriction was noted more in interlock nail group (p = 0.04). Anterior knee pain, chronic osteomyelitis and breakage of distal screw were observed in interlock nail group. No complication was seen in Ender nail group. Conclusion: Ender nailing is a safe and effective choice for treatment of open tibial shaft fractures due to faster fracture union rate and fewer complications. Ender nail is a good implant in treatment of open tibial shaft fractures especially in regions with limited access to specialized, sophisticated and expensive facilities


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 28 - 28
1 Jun 2023
Musielak B Green N Giles S Madan S Fernandes J
Full Access

Introduction. Intramedullary lengthening devices have been in use in older children with closed /open growth plates with good success. This study aims to present the early experience of the FITBONE nail since withdrawal of the PRECICE nail. Materials & Methods. Retrospective analysis of both antegrade and retrograde techniques were utilized. Only patients where union was achieved and full weight bearing commenced were included. The complication rate, length gained, distraction index, weight bearing index (WBI) as well as mechanical axes were analysed. Results. 14 (7 males, 7 females) of a total of 16 (7 males, 7 females) patients with a mean age of 16.9 years with varied diagnosis of LLD were analysed. The mean length gained was 38 mm with an average distraction index of 0,74 mm/day. WBI in these patients on average was 59,6 days/cm lengthened. 6 complications were observed, including two nonunions (successfully treated) and a knee subluxation. Mechanical axis deviation improved from 13,3 mm to 6 mm on average. Overall there has been a nonsignificant tendency for WBI to decrease (Spearman's rank correlation coefficient −0.47, p=0.08) with increasing number of cases done, while no correlation between length gained and WBI (−0.01, p=0.96, respectively) was observed. Some nuances will be discussed. Conclusions. Limb lengthening with the FITBONE nail is relatively safe and efficient, however no significant change was seen in the outcome with previous motorized nails


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 11 - 11
1 Apr 2022
Baumgart R
Full Access

Introduction. Fully implantable distraction nails are frequently used for lengthening of the lower leg. What are the indications for humerus lengthening and which results can be expected?. Materials and Methods. The humerus as the best healing bone in the human body is suitable for lengthening with a nail as well but the indications are rare in comparison with the lower legs. Especially when driving a car or when working on a tablet length discrepancy of the arms of more than 4–5cm may cause severe hardening of the cervical muscles and induce chronical pain in the upper spine. Results. A distraction nail (FITBONE) was used in 5 cases for humerus lengthening. The nail was inserted in all cases from proximal. The mean age of the patients was 34 years. The mean lengthening amount was 58mm (55–100). In one case the system was exchanged to reach the desired length. There was no infection, no radial nerve irritation and no chronical shoulder pain. The system was removed in 4 cases in an average of 15 months the other nail will be removed soon as well. Conclusions. The preliminary results of our 5 cases demonstrate, that the FITBONE device is advantageous for lengthening the humerus, if the initial length is sufficient for implantation. In comparison with the use of external fixators the functional outcome, the comfort of treatment and the cosmetic result is amazing


Bone & Joint Open
Vol. 2, Issue 10 | Pages 825 - 833
8 Oct 2021
Dailey HL Schwarzenberg P Webb, III EB Boran SAM Guerin S Harty JA

Aims. The study objective was to prospectively assess clinical outcomes for a pilot cohort of tibial shaft fractures treated with a new tibial nailing system that produces controlled axial interfragmentary micromotion. The hypothesis was that axial micromotion enhances fracture healing compared to static interlocking. Methods. Patients were treated in a single level I trauma centre over a 2.5-year period. Group allocation was not randomized; both the micromotion nail and standard-of-care static locking nails (control group) were commercially available and selected at the discretion of the treating surgeons. Injury risk levels were quantified using the Nonunion Risk Determination (NURD) score. Radiological healing was assessed until 24 weeks or clinical union. Low-dose CT scans were acquired at 12 weeks and virtual mechanical testing was performed to objectively assess structural bone healing. Results. A total of 37 micromotion patients and 46 control patients were evaluated. There were no significant differences between groups in terms of age, sex, the proportion of open fractures, or NURD score. There were no nonunions (0%) in the micromotion group versus five (11%) in the control group. The proportion of fractures united was significantly higher in the micromotion group compared to control at 12 weeks (54% vs 30% united; p = 0.043), 18 weeks (81% vs 59%; p = 0.034), and 24 weeks (97% vs 74%; p = 0.005). Structural bone healing scores as assessed by CT scans tended to be higher with micromotion compared to control and this difference reached significance in patients who had biological comorbidities such as smoking. Conclusion. In this pilot study, micromotion fixation was associated with improved healing compared to standard tibial nailing. Further prospective clinical studies will be needed to assess the strength and generalizability of any potential benefits of micromotion fixation. Cite this article: Bone Jt Open 2021;2(10):825–833


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 33 - 33
4 Apr 2023
Pareatumbee P Yew A Koh J Zainul-Abidin S Howe T Tan M
Full Access

To quantify bone-nail fit in response to varying nail placements by entry point translation in straight antegrade humeral nailing using three-dimensional (3D) computational analysis. CT scans of ten cadaveric humeri were processed in 3D Slicer to obtain 3D models of the cortical and cancellous bone. The bone was divided into individual slices each consisting of 2% humeral length (L) with the centroid of each slice determined. To represent straight antegrade humeral nail, a rod consisting of two cylinders with diameters of 9.5mm and 8.5mm and length of 0.22L mm and 0.44L mm respectively joined at one end was modelled. The humeral head apex (surgical entry point) was translated by 1mm in both anterior-posterior and medio-lateral directions to generate eight entry points. Total nail protrusion surface area, maximum nail protrusion distance into cortical shell and top, middle, bottom deviation between nail and intramedullary cavity centre were investigated. Statistical analysis between the apex and translated entry points was conducted using paired t-test. A posterior-lateral translation was considered as the optimal entry point with minimum protrusion in comparison to the anterior-medial translation experiencing twice the level of protrusion. Statistically significant differences in cortical protrusion were found in anterior-medial and posterior-lateral directions producing increased and decreased level of protrusion respectively compared to the apex. The bottom anterior-posterior deviation distance appeared to be a key predictor of cortical breach with the distal nail being more susceptible. Furthermore, nails with anterior translation generated higher anterior-posterior deviation (>4mm) compared to posterior translation (<3mm). Aside from slight posterolateral translation of the entry point from the apex, inclusion of a distal posterior-lateral bend into current straight nail design could improve nail fitting within the curved humeral bone, potentially improving distal working length within the flat and narrow medullary canal of the distal humeral shaft


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 6 - 6
4 Jun 2024
Hussain S Cinar EN Baid M Acharya A
Full Access

Background. RHF nail is an important tool for simultaneous ankle and subtalar joint stabilisation +/− fusion. Straight and curved RHF nails are available to use, but both seem to endanger plantar structures, especially the lateral plantar artery and nerve and Baxter's nerve. There is a paucity of literature on the structures at risk with a straight RHF nail inserted along a line bisecting the heel pad and the second toe (after Stephenson et al). In this study, plantar structures ‘at risk’ were studied in relation to a straight nail inserted as above. Methods. Re-creating real-life conditions and strictly following the recommended surgical technique with regards to the incision and guide-wire placement, we inserted an Orthosolutions Oxbridge nail into the tibia across the ankle and subtalar joints in 6 cadaveric specimens. Tissue flaps were then raised to expose the heel plantar structures and studied their relation to the inserted nail. Results. The medial plantar artery and nerve were always more than 10mm away from the medial edge of the nail, while the Baxter nerve was a mean 14mm behind. The lateral plantar nerve was a mean 7mm medial to the nail, while the artery was a mean 2.3mm away with macroscopic injury in one specimen. The other structures ‘at risk’ were the plantar fascia and small foot muscles. Conclusion. Lateral plantar artery and nerve are the most vulnerable structures during straight RHF nailing. The risk to heel plantar structures could be mitigated by making incisions longer, blunt dissection down to bone, meticulous retraction of soft tissues and placement of the protection sleeve down to bone to prevent the entrapment of plantar structures during guide-wire placement, reaming and nail insertion


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 24 - 24
1 Apr 2022
Giotikas D Guryel E
Full Access

Introduction. Stryde® lengthening nail has been recently withdrawn because of concerns about osteolysis and other bone lesions that have been observed early after implantation. The present study analyses the incidence and features of these bone lesions in our patients. Materials and Methods. This is a retrospective review of a series of patients from two centres specializing in limb reconstruction. Inclusion criteria was a history of surgery with Stryde® lengthening nail with more than one year follow-up available. All postoperative x-rays were and clinical notes were reviewed. Results. 36 patients with 75 bone segments were included. 11 (30.5%) patients and 32 (42.6%) bone segments were without any lesion. In 3 (8.3%) patients and 3 (4%) segments, osteolytic lesions only were noticed. 11(30.5%) patients and 14 (18.6%) segments had combined lytic lesions and periosteal reaction or cortical thickening. 12 (33.3%) patients and 26 (34.6%) segments developed only periosteal reaction or cortical thickening. 54.8% of patients with bilateral nailing had bilateral lesions. 52% of the patients with bone lesions reported late onset of pain after the completion of the lengthening. The average earliest interval that any of the lesions was noticed was 10.2 months post-surgery. Conclusions. Patients with Stryde® nails should be monitored clinically and radiologically at regular intervals until removal. The early failure and withdrawal of Precise Stryde® nail, is a significant event in the field of limb reconstruction; this study adds useful data to the growing pool of published data related to the this event


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 29 - 29
14 Nov 2024
Dhillon M Klos K Lenz M Zderic I Gueorguiev B
Full Access

Introduction. Tibiocalcaneal arthrodesis with a retrograde intramedullary nail is an established procedure considered as a salvage in case of severe arthritis and deformity of the ankle and subtalar joints [1]. Recently, a significant development in hindfoot arthrodesis with plates has been indicated. Therefore, the aim of this study was to compare a plate specifically developed for arthrodesis of the hindfoot with an already established nail system [2]. Method. Sixteen paired human cadaveric lower legs with removed forefoot and cut at mid-tibia were assigned to two groups for tibiocalcaneal arthrodesis using either a hindfoot arthrodesis nail or an arthrodesis plate. The specimens were tested under progressively increasing cyclic loading in dorsiflexion and plantar flexion to failure, with monitoring via motion tracking. Initial stiffness was calculated together with range of motion in dorsiflexion and plantar flexion after 200, 400, 600, 800, and 1000 cycles. Cycles to failure were evaluated based on 5° dorsiflexion failure criterion. Result. Initial stiffness in dorsiflexion, plantar flexion, varus, valgus, internal rotation and external rotation did not differ significantly between the two arthrodesis techniques (p ≥ 0.118). Range of motion in dorsiflexion and plantar flexion increased significantly between 200 and 1000 cycles (p < 0.001) and remained not significantly different between the groups (p ≥ 0.120). Cycles to failure did not differ significantly between the two techniques (p = 0.764). Conclusion. From biomechanical point of view, both tested techniques for tibiocalcaneal arthrodesis appear to be applicable. However, clinical trials and other factors, such as extent of the deformity, choice of the approach and preference of the surgeon play the main role for implant choice. Acknowledgements. This study was performed with the assistance of the AO Foundation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 98 - 98
4 Apr 2023
Lu V Tennyson M Zhang J Zhou A Thahir A Krkovic M
Full Access

Fragility ankles fractures in the geriatric population are challenging to manage, due to fracture instability, soft tissue compromise, patient co-morbidities. Traditional management options include open reduction internal fixation, or conservative treatment, both of which are fraught with high complication rates. We aimed to present functional outcomes of elderly patients with fragility ankle fractures treated with tibiotalocalcaneal nails. 171 patients received a tibiotalocalcaneal nail over a six-year period, but only twenty met the inclusion criteria of being over sixty and having poor bone stock, verified by radiological evidence of osteopenia or history of fragility fractures. Primary outcome was mortality risk from co-morbidities, according to the Charlson co-morbidity index (CCI), and patients’ post-operative mobility status compared to pre-operative mobility. Secondary outcomes include intra-operative and post-operative complications, six-month mortality rate, time to mobilisation and union. The mean age was 77.82 years old, five of whom are type 2 diabetics. The average CCI was 5.05. Thirteen patients returned to their pre-operative mobility state. Patients with low CCI are more likely to return to pre-operative mobility status (p=0.16; OR=4.00). Average time to bone union and mobilisation were 92.5 days and 7.63 days, respectively. Mean post-operative AOFAS ankle-hindfoot and Olerud-Molander scores were 53.0 (range 17-88) and 50.9 (range 20-85), respectively. There were four cases of broken distal locking screws, and four cases of superficial infection. Patients with high CCI were more likely to acquire superficial infections (p=0.264, OR=3.857). There were no deep infections, periprosthetic fractures, nail breakages, non-unions. TTC nailing is an effective treatment methodology for low-demand geriatric patients with fragility ankle fractures. This technique leads to low complication rates and early mobilisation. It is not a life-changing procedure, with many able to return to their pre-operative mobility status, which is important for preventing the loss of socioeconomic independence


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 274 - 274
1 Nov 2002
Shaw A Ramamohan N
Full Access

Introduction: While recent guidelines for the treatment of such fractures do not recommend load-bearing devices, there is little evidence actually condemning them, and there is still a lack of literature on the reconstruction nails now generally used. Aim: To evaluate the clinical outcome of pathological (metastatic) proximal femoral fractures treated by either a long Gamma nail, an AO nail with a spiral blade plate (AO-SBP), or a dynamic hip screw (DHS). Method: Eighty-six operations in 80 patients with average age 63.9 years were followed for 18 months or until death. Thirty-one procedures were prophylactic. Results: Thirty Gamma nails (three bilateral), 28 AO SBP rods (three bilateral) and 28 DHS were implanted. The DHS had complications in 10 cases (35%), all occurred in less than 14 months; three implants fractured, four cut out, and three failed to relieve symptoms. The Gamma nail group had two (7%) complications, both after 20 months; one nail fractured and the other lost fixation. The AO-SBP group had two (7%) complications, with one SBP misplacement, and one postoperative death after bilateral nailing. Pain relief and function were greatly improved by the nailing procedures in 57 out of 58 cases. Survival averaged 5.5 months, and was related to primary disease, and presence of visceral metastases. Conclusion: Both the long Gamma and AO- SBP nails reliably treated metastatic proximal femoral fractures, but loss of fixation occurred with long-term survival. The DHS had a high complication rate when used in these cases, and we do not recommend its use


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 110 - 110
1 Nov 2021
Ahmed M Barrie A Kozhikunnath A Thimmegowda A Ho S Kunasingam K Guryel E Collaborative M
Full Access

Introduction and Objective. Lower limb fractures are amongst the most common surgically managed orthopaedic injuries, with open reduction and internal fixation (ORIF) as the conventional method of treatment of the fibula. In recent years, dedicated intramedullary implants have emerged for fibula fixation in tandem with the move towards minimally invasive surgery in high-risk patients. This is the largest multicentre review to date with the aim of establishing the clinical outcomes following intramedullary nail (IMN) fixation of the fibula and to identify the absolute indication for fibula IMN fixation. Materials and Methods. A retrospective study of adult patients in all UK hospitals, who underwent fibula nail fixation between 01/01/2018 and 31/10/2020 was performed. Primary outcome measures included time to union, infection rate, other post-operative complications associated with the fixation and length of hospital stay. The secondary outcome measure was to identify the indication for fibula nailing. Data tabulation was performed using Microsoft Excel and analysis was performed using SPSS Version 23 (SPSS Statistics). Results. 2 Major Trauma Centres (MTCs) and 9 Trauma Units (TUs) were eligible for inclusion. 102 patients were included and 91% were classified as ankle fractures of 68% (n=69) were Weber B, 24% (n=24) Weber C and 8% (n=9) were either distal tibial fractures with an associated fibula fracture or pilon fractures. The mean age was 64 years of which 45 were male patients and 57 were female. The average BMI was 30.03kg/m. 2. and 44% of patients were ASA 3. 74% of patients had poor pre-op skin condition including swelling and open wounds. The calculated infection rate for fibula nail was 4.9% and metal-work complication rate was 4.9%. The average time to union was 13 weeks and length of inpatient stay was 15 days (SD +/− 12 days). Conclusions. MEFNO has demonstrated that fibula nail is an ideal implant in patients who have a physiologically higher risk of surgery, poor skin condition and a complex fracture pattern. The time to union, complication and infection risks are lower than that reported in literature for ankle ORIFs


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 12 - 12
1 Apr 2022
Baumgart R
Full Access

Introduction. Fully implantable systems are used commonly only after maturity. What are indications to use fully implantable systems at the femur even in children?. Materials and Methods. Implantable lengthening nails (FITBONE) were used retrograde at the femur in minimal invasive technique to correct a limb length discrepancy of >6 cm. In 5 cases a relevant deformity was corrected in the same surgery. In all cases a final step of lengthening was planned at the femur and at the tibia with fully implantable devices at maturity. Results. 18 patients with the medium age of 10,3 years (8–14) were treated. In 17 cases the goal of lengthening was achieved without any complication. In one case of proximal femoral deficiency lengthening had to be stopped because of increasing tendency of knee joint luxation. Bone formation occurred circular around the nail in all cases. Full load bearing was possible in the average after 2,2 days/mm. No technical problems occur. In one case induced deformity in the lateral plane was observed which was corrected at the final step. At the end of treatment functional and cosmetical result was perfect in all cases. Conclusions. Fully implantable motorized distraction nails are a favorable option for lengthening and deformity correction of the femur even for children older than 10 years to correct limb length discrepancy of more than 6 cm. The treatment has a low pain level, is comfortable and nearly no scars are visible


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 2 - 2
10 Oct 2023
Heinz N Bugler K Clement N Low X Duckworth A White T
Full Access

To compare the long-term outcomes of fibular nailing and plate fixation for unstable ankle fractures in a cohort of patients under the age of 65 years. Patients from a previously conducted randomized control trial comparing fibular nailing and plate fixation were contacted at a minimum of 10 years post intervention at a single study centre. Short term data were collected prospectively and long-term data were collected retrospectively using an electronic patient record software. Ninety-nine patients from one trauma centre were included (48 fibular nails and 51 plate fixations). Groups were matched for gender (p = 0.579), age (p = 0.811), body mass index (BMI)(p = 0.925), smoking status (p = 0.209), alcohol status (p = 0.679) and injury type (p = 0.674). Radiographically at an average of 2 years post-injury, there was no statistically significant difference between groups for development of osteoarthritis (p = 0.851). Both groups had 1 tibio-talar fusion (2% of both groups) secondary to osteoarthritis with no statistically significant difference in overall re-operation rate between groups identified (p = 0.518,). Forty-five percent (n=42) of patients had so far returned patient reported outcome measures at a minimum of 10 years (Fibular nail n=19, plate fixation n=23). No significant difference was found between groups at 10 years for the Olerud and Molander Ankle Score (p = 0.990), the Manchester-Oxford Foot Questionnaire (p = 0.288), Euroqol-5D Index (p = 0.828) and Euroqol-5D Visual Analogue Score (p = 0.769). The current study illustrates no difference between fibular nail fixation and plate fixation at a long-term follow up of 10 years in patients under 65 years old, although the study is currently under powered