It is reported that more than 10 million Japanese suffer from arthrosis. To cure these cartilage defects, total joint replacements, which are the most popular treatment methods for severe disease situation, have been operated as about two hundred thousand cases a year in Japan. Although the implants made of either ceramics, metals or plastics have high wear resistance quality, it becomes apparent that the endurance life of the artificial joints in considerable cases is limited by aseptic loosening to between 10–15 years. Here we focused on a poly(vinyl alcohol) (PVA) hydrogel as an artificial cartilage tissue to make an improvement of friction surface of the artificial joints. In this paper, we observed morphology of wear
Objectives. This study aimed to characterise and qualitatively grade the severity of the corrosion
Background. Polyethylene (PE) as a bearing material for total joint replacements (TJR) represents the golden standard for the past forty years. However, over the past decade it becomes apparent that PE wear and the biological response to wear products are the limiting factor for the longevity of TJRs. For this reason research has focused onto PE wear
Summary Statement. Antioxidant containing UHMWPE
Introduction. The complex process of inflammation and osteolysis due to wear
Demineralized bone matrix (DBM) is a natural, collagen-based, well-established osteoinductive biomaterial. Nevertheless, there are conflicting reports on the efficacy of this product. The purpose of this study was to evaluate whether DBM collagen structure is affected by
The generation of
INTRODUCTION. Loosening is concerned to be the major cause of revision in the artificial prosthesis. Wear debris of UHMWPE dispersed into the implant-bone interface are phagocytosed by macrophages releasing inflammatory cytokines such as TNF-α which leads to osteolysis and loosening eventually. It is known that the size and structure [1] as well as attached substances on
Today's aging society is seeing an increase of patients with rheumatoid arthritis and osteoarthritis, as well as an increase in joint replacement surgery. The artificial joints used in this surgery frequently uses ultra-high molecular weight polyethylene (UHMWPE) as a bearing material. However, UHMWPE wear
To evaluate the mechanism by which orthopedic implant wear
Introduction. Patients suffering from finger joint pain or dysfunction due to arthritis and traumatic injury may require arthroplasty and joint replacement. Single-part silicone-based implants remain the material of choice and most widely used option, although reports on their long-term clinical performance are variable. For trauma indications, patients have a high expectation of functionality necessitating the use of materials with high wear resistance and mechanical performance. A new proximal inter phalangeal (PIP) joint designed by Zrinski AG (Wurmlingen, Germany), comprising a self-mating carbon fibre reinforced polyetheretherketone (CFR-PEEK) coupling, may provide a suitable alternative. Here we describe the wear performance of the CFR-PEEK components in a PIP joint wear simulator and subsequent characterisation of the wear
We previously reported no clinical differences in short-term results in 26 patients that underwent fixed-bearing (FB) total knee arthroplasty in one knee followed by a rotating-platform (RP) version of the same implant in the contralateral knee at a later date. This study presents intermediate-term results in this unique cohort and uses optimised MRI for detection of
The ability of optimised MRI to detect periarticular bony and soft tissue pathology in the post-arthroplasty hip is well documented; specifically it is able to detect early stages of
Summary Statement. Using the latest Next Generation Sequencing technologies, we have investigated miRNA expression profiles in human trabecular bone from total hip replacement (THR) revision surgery where wear
Endoprosthetic reconstruction for pathologic acetabular fractures is associated with a high risk of periprosthetic joint infection. In this setting, bone defect reconstruction utilising co-delivery of a synthetic bone substitute with an antibiotic, is an attractive treatment option from both, therapeutic and prophylactic perspective. We wished to address some concerns that remain regarding the possible presence of potentially wear inducing
Particulate debris has been demonstrated to have a major role in the aseptic loosening of artificial joints. Biological activity is stimulated by
Summary. Particulate wear debris with different chemical composition induced similar periprosthetic tissue reactions in patients with loosened uncemented and cemented titanium hip implants, which suggests that osteolysis can develop independent of
Introduction: Joint replacement surgery is one of the most common operations that take place in United Kingdom. The major problem in total hip arthroplasty is the generation of particulate wear debris and the subsequent biological responses. Wear debris induces osteolysis and a subsequent failure of the implant that lead to the liberation of greater quantities of particulate and soluble debris to bone marrow, blood, lymph nodes, liver and spleen. Recently, it has been suggested that these adverse effects depend not only on the chemical composition but also on the particulate nature of the material (size and shape).
Introduction: The main problem facing the longevity of total hip replacements (THR) is wear
Deep infection occurs in 2–4% of lower limb arthroplasty resulting in increasing cost, co-morbidity and challenging revision arthroplasty surgery. Identifying the potential sources of infection helps reduce infection rates. The aim of our study is to identify the impact and potential for contamination of our hands and gowns whilst scrubbing using SSHS. A colony-forming unit (CFU) is a pathogenic