A number of
Abstract. Introduction. There are several imaging-based measurements for patello-femoral height. Available methods rely predominantly on sagittal images. The latter can be misleading with sagittal oblique slices and when the patella is tilted and/or chronically subluxed. In this study we describe a simple method of
A number of measurements of patella height exist all of which use a position on the tibia as a reference. The Patellotrochlear Index has recently been proposed as a more accurate reflection of the functional height of the patella and described in normal knees. We aimed to compare
A number of measurements of patella height exist all of which use a position on the tibia as a reference. The Patellotrochlear Index has recently been proposed as a more accurate reflection of the functional height of the patella and described in normal knees. Aim: A comparison of
Aims. This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean follow-up of 7.7 years (5 to 10) after fixed-bearing posterior-stabilized total knee arthroplasty (PS-TKA). Methods. We retrospectively evaluated knee radiographs of 165 knees, which underwent fixed-bearing PS-TKA with patella resurfacing. The incidence of patella baja and changes in patellar height over a minimum of five years of follow-up were determined using Insall-Salvati ratio (ISR) measurement. We examined whether patella baja (ISR < 0.8) at final follow-up affected clinical outcomes, knee joint range of motion (ROM), and Knee Society Score (KSS). We also assessed inter- and intrarater reliability of ISR measurements and focused on the relationship between patellar height reduction beyond measurement error and clinical outcomes. Results. The ISR gradually decreased over five years after TKA, and finally 33 patients (20.0%) had patella baja. Patella baja at the final follow-up was not related to passive knee ROM or KSS. Interestingly, when we divided into two groups - patella baja and patella normal-alta (ISR ≥ 0.8) - the patella baja group already had a lower patellar height before surgery, compared with the patella normal-alta group. The ISR measurement error in this study was 0.17. Both passive knee flexion and KSS were significantly decreased in the group with a decrease in ISR of ≥ 0.17 at final follow-up. Conclusion. Patellar height gradually decreased over five years of follow-up after TKA. The reduction in
Background. Patellar instability is a complex, multi-factorial disorder. Radiological assessment is regarded as an important part of the management of this population. The purpose of this study was to determine the intra- and inter-rater reliability of common radiological measurements used to evaluate patellar instability. Methods. One hundred and fifty x-rays from 51 individuals were reviewed by five reviewers: two orthopaedic trainees, a radiological trainee, a consultant radiologist and an orthopaedic physiotherapist. Radiological measurements assessed included patellar shape, sulcus angle, congruence angle, lateral patellofemoral angle (LPA), lateral patellar displacement (LPD), lateral displacement measurement (LDM), boss height, and patellar height ratios (Caton-Deschamps, Blackburne-Peel, Insall-Salvati). All assessors were provided with a summary document outlining the method of assessing each measurement. Bland-Altman analyses were adopted to assess intra- and inter-rater reliability. Results. The results indicated generally low measurement error on intra-rater reliability assessment, particularly for LPD (within-subject variance 0.7mm to 3.7mm), LDM (0.7mm to 3.5mm) and boss height (0.4mm to 1.6mm) for all assessors. There was greater measurement error for the calculation of sulcus angle (0.7° to 10.6°), congruence angle (0.8° to 18.4°) and LPA (0.8° to 16.5°). Whilst the inter-rater reliability between assessors indicated a low mean difference for assessments of
A radiographic review of sixty-nine lateral closing wedge high tibial osteotomies and forty-two medial opening wedge osteotomies was conducted. Patellar height and tibial slope were measured. The Blackburne-Peel (BP) and Insall-Salvati (IS) ratios were used to measure patellar height. Our results show that 18.8% and 47.6% of the lateral closing wedge group had patella-infera (PI) according the the BP and IS ratios respectively. No opening-wedge cases demonstrated patella infera with either ratio. Tibial slope was found to be significantly more neutral in the closing wedge group versus the opening wedge (−2.2° vs. −7.28° respectively). Patients undergoing HTO typically require a definitive arthroplasty procedure at an average of six years post-HTO. Total knee arthroplasty can be complicated by the presence of PI which compromises exposure and increases the risk of patellar tendon avulsion leading to suboptimal results. The current study compares the incidence of PI between lateral closing and medial opening wedge HTO’s. Conversion of opening wedge HTO to TKA should have less technical challenge and improved outcomes as compared to lateral closing wedge HTO conversions. This is attributable to the absence of PI. Of the closing wedge group, 18.8% and 47.6% were found to have PI according to the BP and IS ratios respectively. Of the opening wedge group there were no cases of PI found with either ratio. Tibial slope was found to be significantly more neutral in the closing wedge compared to the opening wedge group (−2.2° vs. −7.28° respectively). The study cohorts were abstracted from surgeon records. Sixty-nine closing wedge and forty-two opening wedge HTO’s were identified. Lateral 30° flexion x-rays were measured for patellar height and tibial slope. Both the Blackburne-Peel (BP) and Insall-Salvati (IS)