Advertisement for orthosearch.org.uk
Results 1 - 20 of 813
Results per page:
Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims. Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery. Methods. A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group. Results. A total of 15 patients were treated with 3D surgical planning in which 83 screws were placed by using drilling guides. The median deviation of the achieved screw trajectory from the planned trajectory was 3.4° (interquartile range (IQR) 2.5 to 5.4) and the difference in entry points (i.e. plate position) was 3.0 mm (IQR 2.0 to 5.5) compared to the 3D preoperative planning. The length of 72 screws (86.7%) were according to the planning. Compared to the historical cohort, 3D-guided surgery showed an improved surgical reduction in terms of median gap (3.1 vs 4.7 mm; p = 0.126) and step-off (2.9 vs 4.0 mm; p = 0.026). Conclusion. The use of 3D surgical planning including drilling guides was feasible, and facilitated accurate screw directions, screw lengths, and plate positioning. Moreover, the personalized approach improved fracture reduction as compared to a historical cohort. Cite this article: Bone Jt Open 2024;5(1):46–52


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 37 - 37
23 Feb 2023
van der Gaast N Huitema J Brouwers L Edwards M Hermans E Doornberg J Jaarsma R
Full Access

Classification systems for tibial plateau fractures suffer from poor interobserver agreement, and their value in preoperative assessment to guide surgical fixation strategies is limited. For tibial plateau fractures four major characteristics are identified: lateral split fragment, posteromedial fragment, anterior tubercle fragment, and central zone of comminution. These fracture characteristics support preoperative assessment of fractures and guide surgical decision-making as each specific component requires a respective fixation strategy. We aimed to evaluate the additional value of 3D-printed models for the identification of tibial plateau fracture characteristics in terms of the interobserver agreement on different fracture characteristics. Preoperative images of 40 patients were randomly selected. Nine trauma surgeons, eight senior and eight junior registrars indicated the presence or absence of four fracture characteristics with and without 3D-printed models. The Fleiss kappa was used to determine interobserver agreement for fracture classification and for interpretation, the Landis and Koch criteria were used. 3D-printed models lead to a categorical improvement in interobserver agreement for three of four fracture characteristics: lateral split (Kconv = 0.445 versus K3Dprint = 0.620; P < 0.001), anterior tubercle fragment (Kconv = 0.288 versus K3Dprint = 0.449; P < 0.001) and zone of comminution (Kconv = 0.535 versus K3Dprint = 0.652; P < 0.001). The overall interobserver agreement improved for three of four fracture characteristics after the addition of 3D printed models. For two fracture characteristics, lateral split and zone of comminution, a substantial interobserver agreement was achieved. Fracture characteristics seem to be a more reliable way to assess tibial plateau fractures and one should consider including these in the preoperative assessment of tibial plateau fractures compared to the commonly used classification systems


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 83 - 83
1 Dec 2022
Bornes T Kubik J Klinger C Altintas B Dziadosz D Ricci W
Full Access

Tibial plateau fracture reduction involves restoration of alignment and articular congruity. Restorations of sagittal alignment (tibial slope) of medial and lateral condyles of the tibial plateau are independent of each other in the fracture setting. Limited independent assessment of medial and lateral tibial plateau sagittal alignment has been performed to date. Our objective was to characterize medial and lateral tibial slopes using fluoroscopy and to correlate X-ray and CT findings. Phase One: Eight cadaveric knees were mounted in extension. C-arm fluoroscopy was used to acquire an AP image and the C-arm was adjusted in the sagittal plane from 15° of cephalad tilt to 15 ° of caudad tilt with images captured at 0.5° increments. The “perfect AP” angle, defined as the angle that most accurately profiled the articular surface, was determined for medial and lateral condyles of each tibia by five surgeons. Given that it was agreed across surgeons that more than one angle provided an adequate profile of each compartment, a range of AP angles corresponding to adequate images was recorded. Phase Two: Perfect AP angles from Phase One were projected onto sagittal CT images in Horos software in the mid-medial compartment and mid-lateral compartment to determine the precise tangent subchondral anatomic structures seen on CT to serve as dominant bony landmarks in a protocol generated for calculating medial and lateral tibial slopes on CT. Phase Three: 46 additional cadaveric knees were imaged with CT. Tibial slopes were determined in all 54 specimens. Phase One: Based on the perfect AP angle on X-ray, the mean medial slope was 4.2°+/-2.6° posterior and mean lateral slope was 5.0°+/-3.8° posterior in eight knees. A range of AP angles was noted to adequately profile each compartment in all specimens and was noted to be wider in the lateral (3.9°+/-3.8°) than medial compartment (1.8°+/-0.7° p=0.002). Phase Two: In plateaus with a concave shape, the perfect AP angle on X-ray corresponded with a line between the superiormost edges of the anterior and posterior lips of the plateau on CT. In plateaus with a flat or convex shape, the perfect AP angle aligned with a tangent to the subchondral surface extending from center to posterior plateau on CT. Phase Three: Based on the CT protocol created in Phase Two, mean medial slope (5.2°+/-2.3° posterior) was significantly less than lateral slope (7.5°+/-3.0° posterior) in 54 knees (p<0.001). In individual specimens, the difference between medial and lateral slopes was variable, ranging from 6.8° more laterally to 3.1° more medially. In a paired comparison of right and left knees from the same cadaver, no differences were noted between sides (medial p=0.43; lateral p=0.62). On average there is slightly more tibial slope in the lateral plateau than medial plateau (2° greater). However, individual patients may have substantially more lateral slope (up to 6.8°) or even more medial slope (up to 3.1°). Since tibial slope was similar between contralateral limbs, evaluating slope on the uninjured side provides a template for sagittal plane reduction of tibial plateau fractures


Bone & Joint Research
Vol. 9, Issue 6 | Pages 258 - 267
1 Jun 2020
Yao X Zhou K Lv B Wang L Xie J Fu X Yuan J Zhang Y

Aims. Tibial plateau fractures (TPFs) are complex injuries around the knee caused by high- or low-energy trauma. In the present study, we aimed to define the distribution and frequency of TPF lines using a 3D mapping technique and analyze the rationalization of divisions employed by frequently used classifications. Methods. In total, 759 adult patients with 766 affected knees were retrospectively reviewed. The TPF fragments on CT were multiplanar reconstructed, and virtually reduced to match a 3D model of the proximal tibia. 3D heat mapping was subsequently created by graphically superimposing all fracture lines onto a tibia template. Results. The cohort included 405 (53.4%) cases with left knee injuries, 347 (45.7%) cases with right knee injuries, and seven (0.9%) cases with bilateral injuries. On mapping, the hot zones of the fracture lines were mainly concentrated around the anterior cruciate ligament insertion, posterior cruciate ligament insertion, and the inner part of the lateral condyle that extended to the junctional zone between Gerdy’s tubercle and the tibial tubercle. Moreover, the cold zones were scattered in the posteromedial fragment, superior tibiofibular syndesmosis, Gerdy’s tubercle, and tibial tubercle. TPFs with different Orthopaedic Trauma Association/AO Foundation (OTA/AO) subtypes showed peculiar characteristics. Conclusion. TPFs occurred more frequently in the lateral and intermedial column than in the medial column. Fracture lines of tibial plateau occur frequently in the transition zone with marked changes in cortical thickness. According to 3D mapping, the four-column and nine-segment classification had a high degree of matching as compared to the frequently used classifications. Cite this article: Bone Joint Res 2020;9(6):258–267


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 49 - 49
17 Apr 2023
Cooper G Kennedy M Jamal B Shields D
Full Access

Our objective was to conduct a systematic review and meta-analysis, comparing differences in clinical outcomes between either autologous or synthetic bone grafts in the operative management of tibial plateau fractures: a traumatic pattern of injury, associated with poor long-term functional prognosis. A structured search of MEDLINE, EMBASE, The Bone & Joint and CENTRAL databases from inception until 07/28/2021 was performed. Randomised, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture non-union or chondral defects were excluded. Outcome data was assessed using the Risk of Bias 2 (ROB2) framework and synthesised in random-effect meta-analysis. Preferred Reported Items for Systematic Review and Meta-Analysis guidance was followed throughout. Six comparable studies involving 352 patients were identified from 3,078 records. Following ROB2 assessment, five studies (337 patients) were eligible for meta-analysis. Within these studies, more complex tibia plateau fracture patterns (Schatzker IV-VI) were predominant. Primary outcomes showed non-significant reductions in articular depression at immediate postoperative (mean difference −0.45mm, p=0.25, 95% confidence interval (95%CI): −1.21-0.31mm, I. 2. =0%) and long-term (>6 months, standard mean difference −0.56, p=0.09, 95%CI: −1.20-0.08, I. 2. =73%) follow-up in synthetic bone grafts. Secondary outcomes included mechanical alignment, limb functionality, defect site pain, occurrence of surgical site infections, secondary surgery, perioperative blood loss, and duration of surgery. Blood loss was lower (90.08ml, p<0.001, 95%CI: 41.49-138.67ml, I. 2. =0%) and surgery was shorter (16.17minutes, p=0.04, 95%CI: 0.39-31.94minutes, I. 2. =63%) in synthetic treatment groups. All other secondary measures were statistically comparable. Our findings supersede previous literature, demonstrating that synthetic bone grafts are non-inferior to autologous bone grafts, despite their perceived disadvantages (e.g. being biologically inert). In conclusion, surgeons should consider synthetic bone grafts when optimising peri-operative patient morbidity, particularly in complex tibial plateau fractures, where this work is most applicable


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 77 - 77
1 Aug 2020
Wong M Bourget-Murray J Desy N
Full Access

Surgical fixation of tibial plateau fractures in elderly patients with open reduction and internal fixation (ORIF) provides inferior outcomes compared to younger patients. Primary total knee arthroplasty (TKA) may be of benefit in patients with pre-existing arthritis, marked osteopenia, or severe fracture comminution. Rationale for primary TKA includes allowing early mobility in hopes of reducing associated complications such as deconditioning, postoperative pneumonia, or venous thromboembolism, and reducing post-traumatic arthritis which occurs in 25% to 45% of patients and requires revision TKA in up to 15%. Subsequent revision TKA has been shown to have significantly worse outcomes than TKA for primary osteoarthritis. This systematic review sought to elicit the clinical outcomes and peri-operative complication rates following primary TKA for tibial plateau fractures. A comprehensive search of MEDLINE, Embase, and PubMed databases from inception through March 2018 was performed in accordance with PRISMA guidelines. Two reviewers independently screened papers for inclusion and identified studies featuring perioperative complications and clinical outcomes following primary TKA for tibial plateau fractures. Studies were included for final data analysis if they met the following criteria: (1) studies investigating TKA as the initial treatment for tibial plateau fractures, (2) patients must be ≥ 18 years old, (3) have a minimum ≥ 24-month follow-up, and (4) must be published in the English language. Case series, cohort, case-control, and randomized-control trials were included. Weighted means and standard deviations are presented for each outcome. Seven articles (105 patients) were eligible for inclusion. The mean age was 73 years and average follow-up was 39 months. All-cause mortality was 4.75% ± 4.85. The total complication rate was 15.2% ± 17.3% and a total of eight patients required revision surgery. Regarding functional outcomes, the Knee Society score was most commonly reported. The average score on the knee subsection was 85.6 ± 5.5 while the average function subscore was 64.6 ± 13.7. Average range of motion at final follow-up was 107.5° ± 10°. Total knee arthroplasty for the treatment of acute tibial plateau fractures is enticing to allow early mobility and weightbearing. However, complication rates remain high. Functional outcomes are similar to patients treated with ORIF or delayed arthroplasty. Given these findings, surgeons should be highly selective in performing TKA for the immediate treatment of tibial plateau fractures


Bone & Joint Open
Vol. 4, Issue 4 | Pages 273 - 282
20 Apr 2023
Gupta S Yapp LZ Sadczuk D MacDonald DJ Clement ND White TO Keating JF Scott CEH

Aims. To investigate health-related quality of life (HRQoL) of older adults (aged ≥ 60 years) after tibial plateau fracture (TPF) compared to preinjury and population matched values, and what aspects of treatment were most important to patients. Methods. We undertook a retrospective, case-control study of 67 patients at mean 3.5 years (SD 1.3; 1.3 to 6.1) after TPF (47 patients underwent fixation, and 20 nonoperative management). Patients completed EuroQol five-dimension three-level (EQ-5D-3L) questionnaire, Lower Limb Function Scale (LEFS), and Oxford Knee Scores (OKS) for current and recalled prefracture status. Propensity score matching for age, sex, and deprivation in a 1:5 ratio was performed using patient level data from the Health Survey for England to obtain a control group for HRQoL comparison. The primary outcome was the difference in actual (TPF cohort) and expected (matched control) EQ-5D-3L score after TPF. Results. TPF patients had a significantly worse EQ-5D-3L utility (mean difference (MD) 0.09, 95% confidence interval (CI) 0.00 to 0.16; p < 0.001) following their injury compared to matched controls, and had a significant deterioration (MD 0.140, 95% CI 0 to 0.309; p < 0.001) relative to their preoperative status. TPF patients had significantly greater pre-fracture EQ-5D-3L scores compared to controls (p = 0.003), specifically in mobility and pain/discomfort domains. A decline in EQ-5D-3L greater than the minimal important change of 0.105 was present in 36/67 TPF patients (53.7%). Following TPF, OKS (MD -7; interquartile range (IQR) -1 to -15) and LEFS (MD -10; IQR -2 to -26) declined significantly (p < 0.001) from pre-fracture levels. Of the 12 elements of fracture care assessed, the most important to patients were getting back to their own home, having a stable knee, and returning to normal function. Conclusion. TPFs in older adults were associated with a clinically significant deterioration in HRQoL compared to preinjury level and age, sex, and deprivation matched controls for both undisplaced fractures managed nonoperatively and displaced or unstable fractures managed with internal fixation. Cite this article: Bone Jt Open 2023;4(4):273–282


Aims. Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures. Methods. A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture nonunion, or chondral defects were excluded. Outcome data were assessed using the Risk of Bias 2 (ROB2) framework and synthesized in random-effect meta-analysis. The Preferred Reported Items for Systematic Review and Meta-Analyses guidance was followed throughout. Results. Six studies involving 353 fractures were identified from 3,078 records. Following ROB2 assessment, five studies (representing 338 fractures) were appropriate for meta-analysis. Primary outcomes showed non-significant reductions in articular depression at immediate postoperative (mean difference -0.45 mm, p = 0.25, 95%confidence interval (CI) -1.21 to 0.31, I. 2. = 0%) and long-term (> six months, standard mean difference -0.56, p = 0.09, 95% CI -1.20 to 0.08, I. 2. = 73%) follow-up in synthetic bone grafts. Secondary outcomes included mechanical alignment, limb functionality, and defect site pain at long-term follow-up, perioperative blood loss, duration of surgery, occurrence of surgical site infections, and secondary surgery. Mean blood loss was lower (90.08 ml, p < 0.001, 95% CI 41.49 to 138.67) and surgery was shorter (16.17 minutes, p = 0.04, 95% CI 0.39 to 31.94) in synthetic treatment groups. All other secondary measures were statistically comparable. Conclusion. All studies reported similar methodologies and patient populations; however, imprecision may have arisen through performance variation. These findings supersede previous literature and indicate that, despite perceived biological advantages, autologous bone grafting does not demonstrate superiority to synthetic grafts. When selecting a void filler, surgeons should consider patient comorbidity, environmental and societal factors in provision, and perioperative and postoperative care provision. Cite this article: Bone Jt Open 2022;3(3):218–228


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 9 - 9
1 Jul 2022
Fleming T Torrie A Murphy T Dodds A Engelke D Curwen C Gosal H Pegrum J
Full Access

Abstract. INTRODUCTION. COVID-19 reduced availability of cross-sectional imaging, prompting the need to clinically justify pre-operative computed tomography (CT) in tibial plateau fractures (TPF). The study purpose was to establish to what extent does a CT alter the pre-operative plan in TPF compared to radiographs. There is a current paucity of evidence assessing its impact on surgical planning. METHODOLOGY. 50 consecutive TPF with preoperative CT were assessed by 4 consultant surgeons. Anonymised radiographs were assessed defining the column classification, planned setup, approach, and fixation technique. At a 1-month interval, randomised matched CT scans were assessed and the same data collected. A tibial plateau disruption score (TPDS) was derived for all 4 quadrants (no injury=0,split=1,split/depression=2 and depression=3). Radiograph and CT TPDS were assessed using an unpaired T-test. RESULTS. 26 female and 24 male patients, mean age 50.3, were included. Mean TPDS on radiographs and CT scans were 2.77 and 3.17 respectively. A significant higher net CT TPDS was observed of 0.4 (95%CI 0.10-0.71)[P=0.0093]. Both radiograph and CT TPDS ANOVA were significant (P<0.0001), showing high intraobserver variability for TPF classification. Fracture apex requiring fixation changed in 34% of cases between the radiographs and CT, whilst set-up and surgical approach changed in 27% and 28.5% of cases respectively. All surgeons agreed no CT was required in only 11 out of 50 cases. CONCLUSION. CT scanning in TPF significantly affects the classification, setup, approach and fixation technique when compared to radiographs alone and can justifiably be requested as part of pre-operative planning


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 55 - 55
1 Nov 2022
Jimulia D Saad A Malik A
Full Access

Abstract. Background. Anterior cruciate ligament (ACL) injuries with coinciding posterolateral tibial plateau (PLTP) depression fractures are rare. According to the most up to date literature, addressing the PLTP is crucial in preventing failure of the ACL. However, the surgical management of these injuries pose a great challenge to orthopaedic surgeons, given the anatomical location of the depressed PTP fragment. We report a case of a 17-year-old patient presenting to our department with this injury and describe a novel fixation method, that has not been described in the literature. Surgical Technique. A standard 2-portal arthroscopy is used to visualise the fractures. The PLTP is addressed first. With the combined use of arthroscopy and fluoroscopy, a guide pin is triangulated from the anteromedial aspect of the tibia, towards the depressed plateau fragment. Once the guide pin is approximately 1cm from the centre of the fragment, it is over-drilled with a cannulated drill, and simultaneously bluntly punched up to its original anatomical location. Bone graft is then used to fill the void, supported by two subchondral screws. Both fluoroscopy and arthroscopy are used to confirm adequacy of fixation. Finally, the tibial spine avulsion fracture is repaired arthroscopically using the standard suture bridging technique. Conclusion. We describe a novel, one-stage, minimally invasive approach that addresses both the ACL injury and PLTP fracture. We highlight the advantages of utilising this approach and functional outcomes


Bone & Joint Research
Vol. 8, Issue 8 | Pages 357 - 366
1 Aug 2019
Zhang B Sun H Zhan Y He Q Zhu Y Wang Y Luo C

Objectives. CT-based three-column classification (TCC) has been widely used in the treatment of tibial plateau fractures (TPFs). In its updated version (updated three-column concept, uTCC), a fracture morphology-based injury mechanism was proposed for effective treatment guidance. In this study, the injury mechanism of TPFs is further explained, and its inter- and intraobserver reliability is evaluated to perfect the uTCC. Methods. The radiological images of 90 consecutive TPF patients were collected. A total of 47 men (52.2%) and 43 women (47.8%) with a mean age of 49.8 years (. sd. 12.4; 17 to 77) were enrolled in our study. Among them, 57 fractures were on the left side (63.3%) and 33 were on the right side (36.7%); no bilateral fracture existed. Four observers were chosen to classify or estimate independently these randomized cases according to the Schatzker classification, TCC, and injury mechanism. With two rounds of evaluation, the kappa values were calculated to estimate the inter- and intrareliability. Results. The overall inter- and intraobserver agreements of the injury mechanism were substantial (κ. inter. = 0.699, κ. intra. = 0.749, respectively). The initial position and the force direction, which are two components of the injury mechanism, had substantial agreement for both inter-reliability or intrareliability. The inter- and intraobserver agreements were lower in high-energy fractures (Schatzker types IV to VI; κ. inter. = 0.605, κ. intra. = 0.721) compared with low-energy fractures (Schatzker types I to III; κ. inter. = 0.81, κ. intra. = 0.832). The inter- and intraobserver agreements were relatively higher in one-column fractures (κ. inter. = 0.759, κ. intra. = 0.801) compared with two-column and three-column fractures. Conclusion. The complete theory of injury mechanism of TPFs was first put forward to make the TCC consummate. It demonstrates substantial inter- and intraobserver agreement generally. Furthermore, the injury mechanism can be promoted clinically. Cite this article: B-B. Zhang, H. Sun, Y. Zhan, Q-F. He, Y. Zhu, Y-K. Wang, C-F. Luo. Reliability and repeatability of tibial plateau fracture assessment with an injury mechanism-based concept. Bone Joint Res 2019;8:357–366. DOI: 10.1302/2046-3758.88.BJR-2018-0331.R1


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 12 - 12
1 Dec 2021
Samsami S Pätzold R Winkler M Herrmann S Müller PE Chevalier Y Augat P
Full Access

Abstract. Objective. Bi-condylar tibia plateau fractures are one of challenging injuries due to multi-planar fracture lines. The risk of fixation failure is correlated with coronal splits observed in CT images, although established fracture classifications and previous studies disregarded this critical split. This study aimed to experimentally and numerically compare our innovative fracture model (Fracture C), developed based on clinically-observed morphology, with the traditional Horwitz model (Fracture H). Methods. Fractures C and H were realized using six samples of 4th generation tibia Sawbones and fixed with Stryker AxSOS locking plates. Loading was introduced through unilateral knee replacements and distributed 60% medially. Loading was initiated with six static ramps to 250 N and continued with incremental fatigue tests until failure. Corresponding FE models of Fractures C and H were developed in ANSYS using CT scans of Sawbones and CAD data of implants. Loading and boundary conditions similar to experimental situations were applied. All materials were assumed to be homogenous, isotropic, and linear elastic. Von-Mises stresses of implant components were compared between fractures. Results. Fracture C showed 46% lower static stiffness than Fracture H, and it was 38–59% laxer than Fracture H during cyclic loading. Fractures C and H failed at 368±63N and 593±159N, respectively. Von-Mises stress distributions of locking plates indicated that for Fracture C peak stresses, observed around the proximal-inferior and proximal-threadless holes, were 55% higher than Fracture H's, which occurred around the kick-stand hole. The Kick-stand screw of Fracture C demonstrated 65% higher stress than Fracture H's. Conclusions. Experimental outcomes revealed that coronal splits significantly reduced structural stability. Von-Mises stress distributions demonstrated that potential fatigue failure points of implant components depend on the fracture geometry. Therefore, coronal fracture lines should be counted to precisely assess different fixation methods and find the optimum option for this problematic trauma


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 30 - 30
1 Nov 2016
Martin R Meulenkamp B Desy N Duffy P Korley R Puloski S Buckley R
Full Access

Tibial plateau fractures are common injuries. Displaced fractures are treated with open reduction and internal fixation (ORIF). Goals of treatment include restoration of extremity axial alignment, joint stability and congruity, allowing for early motion and prevention of osteoarthritis. Short term results of surgical fixation of tibial plateau fractures are good, however, longer term outcomes have demonstrated a higher risk of end-stage arthritis and total knee arthroplasty. Despite the vast literature around tibial plateau fractures, to our knowledge there are no series examining post-operative reductions using axial imaging. It is our goal to define the incidence of articular malreductions following surgical fixation of tibial plateau fractures, to identify patient or surgeon factors associated with malreductions, and to define any regional patterns of malreduction location. De-identified post operative computed tomography (CT) scans were reviewed to identify tibial plateau malreductions with a step or gap greater than 2 mm, or condylar width greater than 5 mm. Three independent assessors reviewed the scans meeting criteria using Osirix DICOM software. Steps and gaps were mapped onto the axial sequence at the level of the joint line. Images were then matched to side and overlaid as best fit in Photoshop software to create a map of malreductions. A grid was created to divide the medial and lateral plateaus into quadrants to identify the density of malreductions by location. A multi-variate regression model was used to assess risk factors for malreduction. Sixty five post-operative CT scans were reviewed. Twenty one reductions had a step or gap more than 2 mm for a malreduction incidence of 32.3%. The incidence in patients undergoing submeniscal arthrotomy or fluoroscopic assisted reduction was 16.6% and 41.4%, respectively (p <0.001). Side of injury, age, BMI, AO fracture type, and use of locking plates were not predictive of malreduction. Malreductions were heavily weighted to the posterior lateral tibial plateau. The incidence of articular malreductions was high at 32.3%. Fluoroscopic reduction alone was a predictor for articular malreduction with most malreductions located in the posterior lateral quadrants of the plateau


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 76 - 76
1 Jul 2020
Alaqeel M Crapser A Tat J Lee-Howes J Schupbach J Tamimi I Martineau PA
Full Access

Anterior cruciate ligament (ACL) injuries are frequent among athletes and a leading cause of time away from competition. Stability of the knee involves the ACL for limiting anterior tibial translation and the ALL (anterolateral ligament) to restrain internal rotation of the tibia. Present indications for treatment with a combined ACL-ALL reconstruction remain unclear and mostly subjective. We mathematically modeled the tibial plateau geometry to try and identify patients at risk of ACL injury, and develop an objective trigger point for the decision to proceed with additional surgery to optimize rotational stability in these higher risk patients. We hypothesized that an increased convexity and steepness of the posterior aspect of the lateral plateau would subject knees to higher rotational torques leading to potentially a higher risk of ACL injury. The study design was a case-control study involving ACL reconstruction cases (n=68) and matched controls (n=68) between 2008–2015 at our institution. We used a two-dimensional approach, evaluating sagittal MRI images of the knee to model the posterior convexity of the lateral tibial plateau. Points were selected along the articular surface, and a least-squares regression was used to curve-fit a power function (y = a xn). In the equation, larger coefficient a and n represented steeper slopes. The cases and controls were compared using a Mann-Whitney-U test, and the statistical significance was set at α < 0.05. A subgroup analysis for females and males was also performed for the curve-fit coefficients. We observed a significant difference in the tibial surface geometry between our ACL reconstruction cases and matched controls (Figure 1). The modeled power equation for our ACL cases had larger coefficients compared to controls for all groups. For all pooled subjects, coefficient a (ACL recon cases = 0.90 vs controls = 0.68, p < 0.0001) and coefficient n (ACL recon cases = 0.34 vs controls = 0.30, p = 0.07) (Table 1). For the statistically significant coefficient a, we found it had a sensitivity of 78.9% and specificity of 77.5% for the statistically significant coefficient a, we found it had a sensitivity of 78.9% and specificity of 77.5% for predicting injury, using a cut off coefficient of a = 0.78. The odds ratio was 12.6 [5.5 – 29]. The posterolateral cartilaginous slope of the tibial plateau was mathematically modeled in patients with ACL injury. Patients with ACL injury demonstrated abnormally steep and fast slopes compared to controls that may play predispose to ACL injury by increasing anterior translation forces and internal rotation torques sustained by their knee joint. A steeper slope may also explain high-grade pivot shifts on physical exam that are thought to be a relative indication for adding an associated ALL reconstruction. Our findings are promising for adding more objectivity to surgical decision-making, especially with identifying high-risk patients that may be candidates for combined ACL-ALL reconstructions. For any figures or tables, please contact the authors directly


Bone & Joint Research
Vol. 10, Issue 7 | Pages 380 - 387
5 Jul 2021
Shen J Sun D Fu J Wang S Wang X Xie Z

Aims. In contrast to operations performed for other fractures, there is a high incidence rate of surgical site infection (SSI) post-open reduction and internal fixation (ORIF) done for tibial plateau fractures (TPFs). This study investigates the effect of induced membrane technique combined with internal fixation for managing SSI in TPF patients who underwent ORIF. Methods. From April 2013 to May 2017, 46 consecutive patients with SSI post-ORIF for TPFs were managed in our centre with an induced membrane technique. Of these, 35 patients were included for this study, with data analyzed in a retrospective manner. Results. All participants were monitored for a mean of 36 months (24 to 62). None were subjected to amputations. A total of 21 patients underwent two-stage surgeries (Group A), with 14 patients who did not receive second-stage surgery (Group B). Group A did not experience infection recurrence, and no implant or cement spacer loosening was noted in Group B for at least 24 months of follow-up. No significant difference was noted in the Lower Extremity Functional Scale (LEFS) and the Hospital for Special Surgery Knee Score (HSS) between the two groups. The clinical healing time was significantly shorter in Group B (p<0.001). Those with longer duration of infection had poorer functional status (p<0.001). Conclusion. Management of SSI post-ORIF for TPF with induced membrane technique combined with internal fixation represents a feasible mode of treatment with satisfactory outcomes in terms of infection control and functional recovery. Cite this article: Bone Joint Res 2021;10(7):380–387


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 13 - 13
1 May 2021
Davies-Branch NR Oliver WM Davidson EK Duckworth AD Keating JF White TO
Full Access

The aim was to report operative complications, radiographic and patient-reported outcomes following lateral tibial plateau fracture fixation augmented with calcium phosphate cement (CPC). From 2007–2018, 187 patients (median age 57yrs [range 22–88], 63% female [n=118/187]) with a Schatzker II/III fracture were retrospectively identified. There were 103 (55%) ORIF and 84 (45%) percutaneous fixation procedures. Complications and radiographic outcomes were determined from outpatient records and radiographs. Long-term follow-up was via telephone interview. At a median of 6 months (range 0.1–138) postoperatively, complications included superficial peroneal nerve injury (0.5%, n=1/187), infection (6.4%, n=12/187), prominent metalwork (10.2%, n=19/187) and post-traumatic osteoarthritis (PTOA; 5.3%, n=10/187). The median postoperative medial proximal tibial angle was 89o (range 82–107) and posterior proximal tibial angle 82o (range 45–95). Three patients (1.6%) underwent debridement for infection and 27 (14.4%) required metalwork removal. Seven patients (4.2%) underwent total knee replacement for PTOA. Sixty percent of available patients (n=97/163) completed telephone follow-up at a median of 6yrs (range 1–13). The median Oxford Knee Score was 42 (range 3–48), Knee injury and Osteoarthritis Outcome Score 88 (range 10–100), EuroQol 5-Dimension score 0.812 (range −0.349–1.000) and Visual Analogue Scale 75 (range 10–100). There were no significant differences between ORIF and percutaneous fixation in patient-reported outcome (all p>0.05). Fixation augmented with CPC is safe and effective for lateral tibial plateau fractures, with a low complication rate and good long-term knee function and health-related quality of life. Percutaneous fixation offers a viable alternative to ORIF with no detriment to patient-reported outcome


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_3 | Pages 7 - 7
1 Feb 2014
Davidson E Oliver W White T Keating J
Full Access

Tibial plateau fractures are common intraarticular fractures. The principal long-term complication is post-traumatic osteoarthritis (PTOA) with the usual salvage procedure being total knee arthroplasty (TKA). Our aim was to define the incidence of PTOA requiring TKA following tibial plateau fractures and identify the risk factors. We looked at all tibial plateau fractures between 1995 and 2008. There were 888 tibial plateau fractures. 23% were Schatzker I, 25% II, 14% III, 22% IV, 8% V and 8% VI. To date 25 have undergone TKA (2.8%). The mean age of patients at time of fracture was 56 in the overall cohort and 65 in those requiring TKA; this was statistically significant (p=0.04). 4% of females with tibial plateau fractures required TKA in comparison to 2% of males. The Schatzker I fractures were the least likely to require TKA at 1% with the most likely requiring arthroplasty surgery being type III at 6%. Only 1% of the patients treated non-operatively later underwent TKA. The overall incidence of TKA after tibial plateau fractures was 3%. For displaced fractures requiring internal fixation this rose to 4%. Risk factors were increasing age, split depression fractures and female gender. Although tibial plateau fractures are commonly associated with degenerative radiographic changes, we concluded that the incidence of symptomatic OA severe enough to require TKA is low


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_6 | Pages 5 - 5
20 Mar 2023
Gupta S Sadczuk D Riddoch F Oliver W Davidson E White TO Keating JF Scott CEH
Full Access

We aimed to determine the rate of and risk factors for post-traumatic osteoarthritis (PTOA) and total knee arthroplasty (TKA) requirement after operative management of tibial plateau fractures (TPF) in older adults. We conducted a retrospective cohort study of 182 operatively managed TPFs in 180 patients ≥60 years old over a 12-year period with minimum follow up 1 year. Data including patient demographics, clinical frailty scores, mechanism of injury, management, reoperation and mortality were recorded. Radiographs were reviewed for: Schatzker classification; pre-existing knee osteoarthritis (KOA); severe joint depression >15mm; and development of PTOA. Kaplan Meier survival analysis was performed. Regression analysis was used to identify risk factors for radiographic indication for TKA and actual TKA. Forty-seven percent were Schatzker II fractures. Radiographic KOA was present at fracture in 32.6%. Fracture fixation was performed in 95.6% cases and acute TKA in 4.4%. Thirteen patients underwent late TKA (7.5%). At five-years, 11.8% (6.0-16.7 95% CI) had required TKA and 20.9% (14.4-27.4 95% CI) had a radiographic indication for TKA. Severe joint depression and pre-existing KOA were associated with worse survival for endpoints radiographic indication for TKA and actual TKA. Severe joint depression (HR 2.49(1.35-4.61 95% CI), p=0.004), pre-existing KOA (HR 2.23(1.17-4.23), p=0.015) and inflammatory arthropathy (HR 2.4(1.04-5.53), p=0.039) were independently associated with radiographic indication for TKA. In conclusion, severe joint depression and pre-existing arthritis are independent risk factors for both severe PTOA and TKA after TPFs in older adults. These features should be considered as an indication for primary management with acute TKA


Introduction. Schatzker V & VI tibial plateau fractures are serious life-changing injuries often resulting in significant complications including post-traumatic arthritis. Reported incidence of secondary TKA following ORIF of all tibial plateau fractures is 7.3% and 13% for Schatzker V & VI tibial. This study reports a 15-year single centre experience of CEF of Schatzker V & VI fractures including PROMs and incidence of secondary TKA. This study was approved by the local Institutional board. Materials & Methods. All patients from 2007 – 2022 with Schatzker V or VI fractures treated with CEF were identified from a departmental limb reconstruction registry and included in this retrospective study. Patients’ demographics were collected from electronic institutional patient system. Further data was collected for secondary intervention, adverse events, and alignment at discharge. All deceased patients at the time of the study were excluded. Each participant completed a questionnaire about secondary intervention, EQ-5D-3L and Oxford Knee Score (OKS). Results. 90 patients (from 130 eligible) with an average age of 58.3 years completed the questionnaire. At an average follow up of 7.4 years (SD=3.8) the incidence of secondary TKA was 7.8%. There was no significant correlation between articular incongruity and the incidence of secondary TKA. The mean OKS score was 31.7 (SD=13.3). The mean EQ-VAS was 69.3 (SD=23.3) and the mean EQ-5D Index was 0.595 (SD=0.395), both were significantly lower than UK normal population means. Conclusions. This study is probably one of the largest and with the longest follow-up reporting the outcomes of Schatzker V and VI fractures treated with CEF. It appears that articular incongruity has no significant correlation with secondary TKA. Patients reported EQ-5D-3L scores were significantly lower than those for the normal UK population, and the average EQ-VAS has deteriorated with time. This study would be relevant in counselling and consenting patients with this severe injury


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 27 - 27
1 Jan 2022
De C Kainth N Harbham P Brooks M Agarwal S
Full Access

Abstract. Background. This study aims to estimate the risk of acquiring a medical complication or death from COVID-19 infection in patients who were admitted for orthopaedic trauma surgery during the peak and plateau of pandemic. Unlike other recently published studies, where patient-cohort includes a more morbid group and cancer surgeries, we report on a group more akin to those having routine elective orthopaedic surgery. Methods. The study included 214 patients who underwent orthopaedic trauma surgeries in the hospital between 12th March and 12th May 2020 when the COVID-19 pandemic was on the rise in the United Kingdom. Data was collected on demographic profile including comorbidities, ASA grade, COVID-19 test results, type of procedures and any readmissions, complications or mortality due to COVID-19. Results. There were 7.9% readmissions and 52.9% of it was for respiratory complications. Only one patient had positive COVID-19 test during readmission. 30-day mortality for trauma surgeries was 0% if hip fractures were excluded and 2.8% in all patients. All the mortalities were for neck of femur fracture surgeries and between ASA Grade 3 and 4 or in patients above the age of 70 years. Conclusion. This study suggests that presence of COVID-19 virus in the community and hospital did not adversely affect the outcome of orthopaedic trauma surgeries or lead to excess mortality or readmissions in patients undergoing limb trauma surgery. The findings also support resumption of elective orthopaedic surgeries with appropriate risk stratification, patient optimization and with adequate infrastructural support amidst the recovery phase of the pandemic