The St Leger total knee replacement is a bicondylar prosthesis developed as a cheaper alternative to other similar implants of its time. Between October 1993 and June 1999, 144 St Leger total knee replacements were implanted in 114 patients. The aim of this study was to clinically and radiologically assess these patients after a mean follow up of 10.22 years. Between February and July 2007 ninety-one patients recalled for clinical evaluation (using functional and objective Knee Society Scores) and radiological assessment (using the Knee Society Scoring System). 11 patients had died and 12 were lost to follow up or were medically unfit to attend evaluation. Of the ninety-one patients recalled, 18 had had their prostheses revised (19 knees). 63% of prostheses had survived 10 years or more. Of the patients with St Leger knees in situ (99 knees) the American Knee Scores showed 78% poor, 10% fair, 6% good and 6% excellent results.
The St Leger total knee replacement is a bicondylar prosthesis developed as an cheaper alternative to other similar implants of its time. Between October 1993 and June 1999, 144 St Leger total knee replacements were implanted in 114 patients. The aim of this study was to clinically and radiologically assess these patients after a mean follow up of 10.22 years. Between February and July 2007 ninety-one patients recalled for clinical evaluation (using functional and objective American Knee Society Scores) and radiological assessment (using the American Knee Society Scoring System). 11 patients had died and 12 were lost to follow up or were medically unfit to attend evaluation. Of the ninety-one patients recalled, 18 had had their prostheses revised (19 knees). 63% of prostheses had survived 10 years or more. Of the patients with St Leger knees in situ (99 knees) the American Knee Scores showed 78% poor, 10% fair, 6% good and 6% excellent results.
Hip disease is common in children with cerebral palsy (CP) and can decrease quality of life and function. Surveillance programmes exist to improve outcomes by treating hip disease at an early stage using radiological surveillance. However, studies and surveillance programmes report different radiological outcomes, making it difficult to compare. We aimed to identify the most important radiological measurements and develop a core measurement set (CMS) for clinical practice, research, and surveillance programmes. A systematic review identified a list of measurements previously used in studies reporting radiological hip outcomes in children with CP. These measurements informed a two-round Delphi study, conducted among orthopaedic surgeons and specialist physiotherapists. Participants rated each measurement on a nine-point Likert scale (‘not important’ to ‘critically important’). A consensus meeting was held to finalize the CMS.Aims
Methods
Recently, new metallurgical techniques allowed the creation of 3D metal matrices for cementless acetabular components. Among several different products now available on the market, the Biofoam Dynasty cup (MicroPort Orthopedics® Inc., Arlington, TN, USA) uses an ultraporous Titanium technology but has never been assessed in literature. Coping with this lack of information, our study aims to assess its radiological osteointegration at two years in a primary total hip arthroplasty and compares it to a successful contemporary cementless acetabular cup. This monocentric retrospective study includes 96 Dynasty Biofoam acetabular components implanted between March 2010 and August 2014 with a minimum 2 years radiographic follow-up. Previous acetabular surgery, any septic issue or re-operation for component malposition were exclusion criteria. They were compared to 96 THA using the Trident PSL matched for age, gender, BMI and follow-up. Presence of radiolucencies and sclerotic lines were described on AP pelvis views using the classification of DeLee and Charnley There was no statistical difference between the two groups concerning demographics and mean follow-up (p> 0.05). Shell's anteversion was similar but inclination was greater in the biofoam group (p=0.006). 27,17% of the Biofoam shells presented radiolucencies in 2 zones or more and 0% of the Trident shells. 11,96% of Biofoam cups showed radiolucencies in the 3 zones of DeLee comparing to 0% of the Trident cups. There was no statistical difference between the Biofoam group (n=54/96) and the Trident PSL group (n=57/96) in pre-operative functional scores for both WOMAC subscales and SF-12. When evaluating last follow-up PROM's, no significant differences were found comparing the entirety of both groups, 56 Biofoam and 51 Trident PSL. No difference was found either when comparing Biofoam patients with ³ 2 zones of radiolucencies (n=15) to the whole Trident group (n=51). This study raises concerns about radiologic evidence of osteointegration of the Biofoam acetabular cup. Nevertheless, these radiological findings do not find any clinical correlation considering clinical scores. Thus, it may question the real meaning of these high-rated radiolucencies, which at first sight reflect a poorer osteointegration. The first possible limitation with this study is an overinterpretation of the radiographs. Nevertheless, both observers were blinded regarding the patients groups and clinical outcomes and there was a strong inter-observer reliability. Although both cohorts were matched on their demographics and were similar on the cup anteversion, we noticed a slightly lower abduction angle in the Biofoam population. It could reduce the bone-implant coverage area and hence hinders the bony integration, but this difference was small and both groups remained in the Lewinneck security zone. Furthermore, even if patients were matched on age, gender, BMI and follow-up, other variables can influence early osteointegration (smoke status, osteoporosis) and have not been controlled even though we have no reasons to think their distribution could differ in the 2 groups. The real clinical meaning of these findings remains unknown but serious concerns are raised about the radiographic osteointegration of the Dynasty Biofoam acetabular components. Concerns are all the more lawful that this implants aim to enhance osteointegration.
Stand-alone anterior lumbar interbody fusion (ALIF) provides the opportunity to avoid supplemental posterior fixation. This may reduce morbidity and complication rate, which is of special interest in patients with reduced bone mineral density (BMD). This study aims to assess immediate biomechanical stability and radiographic outcome of a stand-alone ALIF device with integrated screws in specimens of low BMD. Eight human cadaveric spines (L4-sacrum) were instrumented with SynFix-LR™ (DePuy Synthes) at L5/S1. Quantitative computed tomography was used to measure BMD of L5 in AMIRA. Threshold values proposed by the American Society of Radiology 80 and 120 mg CaHa/mL were used to differentiate between Osteoporosis, Osteopenia, and normal BMD. Segmental lordosis, anterior and posterior disc height were analysed on pre- and postoperative radiographs (Fig 1). Specimens were tested intact and following instrumentation using a flexibility protocol consisting of three loading cycles to ±7.5 Nm in flexion-extension, lateral bending, and axial rotation. The ranges of motion (ROM) of the index level were assessed using an optoelectronic system. BMD ranged 58–181mg CaHA/mL. Comparison of pre- and postoperative radiographs revealed significant increase of L5/S1 segmental lordosis (mean 14.6°, SD 5.1, p < 0.001) and anterior disc height (mean 5.8mm, SD 1.8, p < 0.001), but not posterior disc height. ROM of 6 specimens was reduced compared to the intact state. Two specimens showed destructive failure in extension. Mean decrease was most distinct in axial rotation up to 83% followed by flexion-extension. ALIF device with integrated screws at L5/S1 significantly increases segmental lordosis and anterior disc height without correlation to BMD. Primary stability in the immediate postoperative situation is mostly warranted in axial rotation. The risk of failure might be increased in extension for some patients with reduced lumbar BMD, therefore additional posterior stabilization could be considered. For any figures or tables, please contact the authors directly.
Total Elbow Replacements are indicated for pain and disability in patients with rheumatoid and osteoarthritis of the elbow. The quality of the cementation has been specifically studied and shown to be directly related to the clinical outcome and implant survival. The aim of our study is to radiologically assess and grade the cementation around the components following total elbow replacement (GSB 3 or Coonrad Morrey) in two groups of patients. Group I underwent total elbow replacement using Heraeus cement gun with medium palacos viscosity cement and group 2 using Zimmer cement gun with simplex medium viscosity cement. Average age in Group 1 was 72.3 (range 67–88 yrs) and group 2 was 69 years (range 52–87 yrs) 3 Coonrad Morrey and 13 GSB 3 total elbow replacement were used in Group 1 and 2 Coonrad Morrey and 14 GSB 3 in group 2. The primary indication for surgery was osteoarthritis, rheumatoid arthritis, post traumatic arthritis and seronegative arthritis in both groups. The cementation was assessed radiologically using three grading system (Morrey, Gerber & Bristol).Aim
Materials and methods
The current standard of practice following knee arthroplasty is to demonstrate the appropriate alignment of knee replacements using knee radiographs. Recent studies have suggested that standard knee radiographs provide adequate accuracy for tibial prosthesis alignment assessment as compared with long knee view radiographs which are more technically demanding and carry greater radiation exposure. In this study, we aim to address whether alignment measured on standard knee radiographs are reliable and reproducible over time. We examined a cohort of 80 patients 37 male (46%), 43 females (54%), mean age = 68 years) who underwent total knee arthroplasty (TKA). Standard knee anteroposterior radiographs performed within 2 days following surgery were compared to standard knee anteroposterior radiographs taken 1 year following the surgery in patients with well-functioning prosthesis. Tibial prosthesis alignment angles between the longitude of the tibial shaft and the tibial baseplate were calculated using Centricity Enterprise Web V3.0 software. The data was examined using R software. In well-functioning primary knee arthroplasties, tibial prosthesis alignment angles measured in the 1-year follow-up standard view knee radiographs were found to deviate from measurements obtained with the same radiographic specifications in the immediate post-operative period. A significant mean percentage difference was found between the two radiographs. Long knee view radiographs may be required in order to accurately assess tibial prothesis alignment following total knee arthroplasty.
Implant stability and is an important factor for adequate bone remodelling and both are crucial in the long-term clinical survival of total hip arthroplasty (THA). Assessment of early bone remodelling on X-rays during the first 2 years post-operatively is mandatory when stepwise introduction of a new implant is performed. Regardless of fixation type (cemented or cementless), early acetabular component migration is usually the weakest link in THA, eventually leading to loosening. Over the past years, a shift towards uncemented cup designs has occurred. Besides the established hydroxyapatite (HA) coated uncemented cups which provide ongrowth of bone, new uncemented implant designs stimulating ingrowth of bone have increased in popularity. These cups initiate ingrowth of bone into the implant by their open metallic structure with peripheral pores, to obtain a mechanical interlock with the surrounding bone, thereby stabilising the prosthesis in an early stage after implantation. This retrospective study assessed bone remodelling, osseointegration and occurrence of radiolucency around a new ingrowth philosophy acetabular implant. In a retrospectively, single centre cohort study all patients whom underwent primary THA with a Tritanium acetabular component in 2011 were included. Bone remodelling, osseointegration and occurrence of radiolucency were determined by two reviewers from X-ray images that were made at 6 weeks, 3–6-12 and 24 months post-operatively. Bone contact % was calculated based on the original Charnley and DeLee zones. According to Charnley and DeLee the outer surface of an acetabular cup is divided into 3 zones (1-2-3). For our analysis the original 3 zones were further divided into 2 producing 6 zones 1A to 3B. Each of these 6 zones were then further divided into 4 equal sections. We attributed 25 points per section in which complete bone contact without lucency was observed. If lucency was observed no points were attributed to the section. A fully osteointegrated cup in all 24 sections could therefore attain 600 points. The total of each section and zone was subsequently tallied and recalculated to produce the percentage of bone contact on a 1–100% score.Background
Methods
To evaluate the diagnostic characteristics and reliability of radiological methods used to assess scaphoid fracture union through a systematic review and meta-analysis. MEDLINE, Embase, and the Cochrane Library were searched from inception to June 2022. Any study reporting data on the diagnostic characteristics and/or the reliability of radiological methods assessing scaphoid union was included. Data were extracted and checked for accuracy and completeness by pairs of reviewers. Methodological quality was assessed using the QUADAS-2 tool.Aims
Methods
Previous work has demonstrated vulnerability of the femoral nerve to damage by anterior acetabular retractors during THA. The aim of this study was to quantify the proximity of the femoral nerve to the anterior acetabulum, on cadaveric material and MRI studies. A standard posterior approach to the hip was carried out in 6 fresh frozen cadaveric hemipelves. Following dislocation and removal of the femoral head, measurements were taken from the anterior acetabular lip to the posterior aspect of the femoral nerve as it passed over this point. 14 MRI studies of the hip were obtained from the local PACS database (7 male, 7 female; mean age 58 (range 32–80)). T1 weighted axial scans were reviewed. Measurements were obtained from the anterior acetabular lip to the posterior surface of the femoral nerve and artery, and the cross-sectional area of iliopsoas was calculated. There was no significant difference between the mean distances to the femoral nerve in the cadaveric (24 mm) and MRI groups (25.3mm) (p=0.7). On MRI images, the distance between the acetabular wall and both the femoral artery (p=0.003) and femoral nerve (p=0.007) was significantly larger in men. The femoral artery is strikingly close to the acetabulum in females, passing a mean distance of 14.8 mm, whereas in males this was 23.9 mm. The mean femoral nerve distance was 28.7 mm in males and 21.9 mm in females. The cross-sectional area of iliopsoas was significantly smaller in women (5.97 cm2 compared to 11.37 cm2, p<0.001). Both the femoral artery and nerve run in close proximity to the anterior acetabular lip. Care should be taken when placing instruments in this area to avoid neurovascular injury. The increased incidence of femoral nerve damage in women following THA may be due to the significantly smaller bulk of iliopsoas.
Pelvic and acetabular injuries are relatively rare and surgical reconstruction usually occurs only in specialist centres. As part of their work up there is a local protocol for radiological investigations including Judet oblique views for acetabular fractures, pelvic inlet and outlet for pelvic ring fractures and urethrograms for sustaining anterior pelvic injury. The aim of this service evaluation was to assess whether patients had these radiological investigations prior to transfer. The last 50 patients transferred for surgery were evaluated (41 male, 9 female), average age 48 (range 17–86). Four were excluded as original radiology not available and one due to non-acute presentation. Regional PACS systems were accessed and radiological investigations recorded.Introduction
Methods
The radiological analysis was based on 193 AP and lateral x-rays. We measured: 1) the distance separating the superior pole of the cyst from the suprajacent growth cartilage, 2) the largest cyst diameter, 3) the greatest cyst height, 4) the thinnest cortical width facing the cyst, 5) the cyst surface area calculated exactly using surface area software and expressed as a a ratio of shaft diameter (S/d2, Kaelin index). These different parameters were compared for cysts associated with fracture or not.
Comparing the two cohorts of patients demonstrated that the following differences were significant (Student’s t test): 1) cyst width (p=0.0038): below 16 mm none of the cysts fractured. For wider cysts, there was no difference between the fracture and non-fracture cysts. 2) cortical thickness (p=0.0002); cortical thickness greater than 5 mm protected against fracture. If the cortical measured less than 3 mm, the risk of fracture was greater than 50%. 3) Kaelin index: (p<
0.0001) was directly correlated with fracture risk but no cutoff could be identified. For an 80 – 100% risk of fracture, the cyst must have the following characteristics: width >
30 mm, height >
75 mm, cortical thickness <
2.4 mm, Kaelin index >
5. For a 50% risk of fracture, the cyst must have the following characteristics: width >
24 mm, height >
55 mm, cortical thickness <
3 mm, Kaelin index >
3.
Anterior decompression and adequate spine fixation in patients with cervical radiculopathy and myelopathy are essential for functional restoration of cervical spine. In this study, we performed evaluation and comparative radiological assessment of several types of spinal implants in terms of bone block formation, sagittal alignment and effectiveness as a structural support.
Group1. Autograft – 91 patients Group 2. TiNi alloy cages – 74 patients. Group 3. Varilift expandable cages without plate fixation – 22 patients Group 4. Verilift cages with plate fixation – 8 patients Group 5. Bone substitute spacer and plate fixation – 3 patients.
The aim of this study was to assess the results of bone ingrowth into the glenoid component of one design of Total Shoulder Arthroplasty (TSA) in which hydroxyapatite (HA) coating of the glenoid baseplate was introduced since 1997. Glenoid loosening is one of the most important complications of both cemented and uncemented TSA. Between May 1993 and April 1997 over 140 uncemented, porous coated, metal backed glenoid component were used in our Unit. By 1997 it had become clear that a significant number of these glenoid components had developed mechanical loosening and some required revision. We therefore started using an HA coated glenoid component for our TSAs from April 1997. One hundred and seventy-four shoulder arthroplasty procedures were performed between April 1997 and October 1999 of which 37 were TSAs using the HA coated uncemented glenoid. The indications included osteoarthritis (22), rheumatoid arthritis (nine), revision TSA (three), avascular necrosis (two) and cuff arthropathy with cuff reconstruction (one). The minimum follow-up was 18 months. The X rays were evaluated using the MLS (Migration, Lucent lines, Screw problems) system, which had been developed and reported previously. This system of evaluation has been shown to be reproducible for assessment of glenoid fixation. There was one case in which the glenoid liner became displaced and had to be replaced. Our early results at a mean FU of approximately 2 years show an improved radiological fixation compared with those glenoids inserted without HA.