Kiapour AM Murray MM

Injury to the anterior cruciate ligament (ACL) is one of the most devastating and frequent injuries of the knee. Surgical reconstruction is the current standard of care for treatment of ACL injuries in active patients. The widespread adoption of ACL reconstruction over primary repair was based on early perception of the limited healing capacity of the ACL. Although the majority of ACL reconstruction surgeries successfully restore gross joint stability, post-traumatic osteoarthritis is commonplace following these injuries, even with ACL reconstruction. The development of new techniques to limit the long-term clinical sequelae associated with ACL reconstruction has been the main focus of research over the past decades. The improved knowledge of healing, along with recent advances in tissue engineering and regenerative medicine, has resulted in the discovery of novel biologically augmented ACL-repair techniques that have satisfactory outcomes in preclinical studies. This instructional review provides a summary of the latest advances made in ACL repair. Cite this article: Bone Joint Res 2014;3:20–31


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 32 - 32
1 Dec 2022
Kamikovski I Woodmass J McRae S Lapner P Jong B Marsh J Old J Dubberley J Stranges G MacDonald PB
Full Access

Previously, we conducted a multi-center, double-blinded randomized controlled trial comparing arthroscopic Bankart repair with and without remplissage. The end point for the randomized controlled trial was two years post-operative, providing support for the benefits of remplissage in the short term in reducing recurrent instability. The aim of this study was to compare the medium term (3 to 9 years) outcomes of patients previously randomized to have undergone isolated Bankart repair (NO REMP) or Bankart repair with remplissage (REMP) for the management of recurrent anterior glenohumeral instability. The rate of recurrent instability and instances of re-operation were examined. The original study was a double-blinded, randomized clinical trial with two 1:1 parallel groups with recruitment undertaken between 2011 and 2017. For this medium-term study, participants were reached for a telephone follow-up in 2020 and asked a series of standardized questions regarding ensuing instances of subluxation, dislocation or reoperation that had occurred on their shoulder for which they were randomized. Descriptive statistics were generated for all variables. “Failure” was defined as occurrence of a dislocation. “Recurrent instability” was defined as the participant reporting a dislocation or two or more occurences of subluxation greater than one year post-operative. All analyses were undertaken based on intention-to-treat whereby their data was analyzed based on the group to which they were originally allocated. One-hundred and eight participants were randomized of which 50 in the NO REMP group and 52 in the REMP group were included in the analyses in the original study. The mean number of months from surgery to final follow-up was 49.3 for the NO REMP group and 53.8 for the REMP group. The rates of re-dislocation or failure were 8% (4/52) in the REMP group at an average of 23.8 months post-operative versus 22% (11/50) in the NO REMP at an average of 16.5 months post-operative. The rates of recurrent instability were 10% (5/52) in the REMP group at an average of 24 months post-operative versus 30% (15/50) in the NO REMP group at an average of 19.5 months post-operative. Survival curves were significantly different favouring REMP in both scenarios. Arthroscopic Bankart repair combined with remplissage is an effective procedure in the treatment of patients with an engaging Hill-Sachs lesion and minimal glenoid bone loss (<15%). Patients can expect favourable rates of recurrent instability when compared with isolated Bankart repair at medium term follw-up


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 56 - 56
1 Aug 2020
Stockton DJ Tobias G Pike J Daneshvar P Goetz TJ
Full Access

Compared to single-incision distal biceps repair (SI), double-incision repair (DI) theoretically allows for reattachment of the tendon to a more anatomically favorable position. We hypothesized that DI repair would result in greater terminal supination torque compared to SI repair for acute distal biceps ruptures. In this retrospective cohort study, patients were included if they sustained an isolated, acute (° supinated position. Secondary outcomes included supination torque in 45° supinated, neutral, and 45° pronated positions, ASES elbow score, DASH, SF-12, and VAS. Power analysis revealed that at least 32 patients were needed to detect a minimum 15% difference in the primary outcome (β = 0.20). Statistical analysis was performed with significance level α = 0.05 using R version 3.4.1 (R Core Team 2017, Vienna, Austria). Of 53 eligible patients, 37 consented to participate. Fifteen were repaired using DI technique and 22 using SI technique. Mean age was 47.3yrs and median follow-up time was 28.1months. The groups did not differ with respect to age, time-to-follow-up, dominance of arm affected, Workers Compensation or smoking status. Mean supination torque, measured as the percentage of the unaffected side, was 60.9% (95%CI 45.1–76.7) for DI repair versus 80.4% (95%CI 69.1–91.7) for SI repair at the 60°supinated position (p=0.036). There were no statistically significant differences in mean supination torque at the 45°supinated position: 67.1% (95%CI 49.4–84.7) for DI versus 81.8% (95%CI 72.2–91.4) for SI (p=0.102), at the neutral position: 88.8% (95%CI 75.2–102.4) for DI versus 97.6% (95%CI 91.6–103.7) for SI (p=0.0.170), and at the 45°pronated position: 104.5% (95%CI 91.1–117.9) for DI versus 103.4 (95%CI 97.2–109.6) for SI (p=0.0.862). No statistically significant differences were detected in the secondary outcomes ASES Pain, ASES Function, DASH scores, SF-12 PCS or MCS, or VAS Pain. A small difference was detected in VAS Function (median 1.3 for DI repair versus 0.5 for SI repair, p=0.023). In a multivariate linear regression model controlling for arm dominance, age, and follow-up time, SI repair was associated with a greater mean supination torque than DI repair by 19.6% at the 60°supinated position (p=0.011). Contrary to our hypothesis, we found approximately a 20% mean improvement in terminal supination torque for acute distal biceps ruptures repaired with the single-incision technique compared to the double-incision technique. Patients uniformly did well with either technique, though we contend that this finding may have clinical significance for the more discerning, high-demand patient


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 58 - 58
1 Jul 2020
Stockton DJ Tobias G Pike J Daneshvar P Goetz TJ
Full Access

Compared to single-incision distal biceps repair (SI), double-incision repair (DI) theoretically allows for reattachment of the tendon to a more anatomically favorable position. We hypothesized that DI repair would result in greater terminal supination torque compared to SI repair for acute distal biceps ruptures. In this retrospective cohort study, patients were included if they sustained an isolated, acute (° supinated position. Secondary outcomes included supination torque in 45° supinated, neutral, and 45° pronated positions, ASES elbow score, DASH, SF-12, and VAS. Power analysis revealed that at least 32 patients were needed to detect a minimum 15% difference in the primary outcome (β = 0.20). Statistical analysis was performed with significance level α = 0.05 using R version 3.4.1 (R Core Team 2017, Vienna, Austria). Of 53 eligible patients, 37 consented to participate. Fifteen were repaired using DI technique and 22 using SI technique. Mean age was 47.3yrs and median follow-up time was 28.1months. The groups did not differ with respect to age, time-to-follow-up, dominance of arm affected, Workers Compensation or smoking status. Mean supination torque, measured as the percentage of the unaffected side, was 60.9% (95%CI 45.1–76.7) for DI repair versus 80.4% (95%CI 69.1–91.7) for SI repair at the 60°supinated position (p=0.036). There were no statistically significant differences in mean supination torque at the 45°supinated position: 67.1% (95%CI 49.4–84.7) for DI versus 81.8% (95%CI 72.2–91.4) for SI (p=0.102), at the neutral position: 88.8% (95%CI 75.2–102.4) for DI versus 97.6% (95%CI 91.6–103.7) for SI (p=0.0.170), and at the 45°pronated position: 104.5% (95%CI 91.1–117.9) for DI versus 103.4 (95%CI 97.2–109.6) for SI (p=0.0.862). No statistically significant differences were detected in the secondary outcomes ASES Pain, ASES Function, DASH scores, SF-12 PCS or MCS, or VAS Pain. A small difference was detected in VAS Function (median 1.3 for DI repair versus 0.5 for SI repair, p=0.023). In a multivariate linear regression model controlling for arm dominance, age, and follow-up time, SI repair was associated with a greater mean supination torque than DI repair by 19.6% at the 60°supinated position (p=0.011). Contrary to our hypothesis, we found approximately a 20% mean improvement in terminal supination torque for acute distal biceps ruptures repaired with the single-incision technique compared to the double-incision technique. Patients uniformly did well with either technique, though we contend that this finding may have clinical significance for the more discerning, high-demand patient


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 103 - 103
1 Jul 2020
Peck J Pincus D Wasserstein D Kreder H Henry P
Full Access

Rotator cuff repair (RCR) can be performed open or arthroscopically, with a recent dramatic increase in the latter. Despite controversy about the preferred technique, there has been an increase in the number of repairs performed arthroscopically. The purpose of this study was, therefore, to compare revision rates following open and arthroscopic RCR repair. Adult patients undergoing first-time, primary rotator cuff repair in Ontario, Canada (April 2003-March 2014) were identified using physician billing and hospital databases. Patients were followed for a minimum of two and up to 13 years for the primary outcome, revision rotator cuff repair, and secondary outcome, surgical site infection. The intervention considered was open versus arthroscopic technique. Patient factors (age, gender, residence, socioeconomic status, medical comorbidities) and provider factors (surgical volume, hospital setting, worked night before, year of surgery) were recorded. Standardized mean differences were used for covariate comparison. A Cox Proportional Hazards model was used to compare RCR survivorship between the two groups after adjustment for patient and provider factors, generating hazard ratios with 95% confidence intervals (HR, 95% CIs). Censoring occurred on the first of the primary outcome, death, shoulder arthroplasty or arthrodesis, or the end of the follow-up period (March 2016). A total of 37,255 patients were included. The overall revision RCR rate was 2.9% (1,096 patients) with a median time to revision of 23 months (IQR 12–52). Revision repair was more common in the arthroscopic group in comparison to the open group (3.2% vs 2.6%, NNT 166.7, p=0.004), with an adjusted HR of 0.72 (0.63–0.83 95% CI, p < 0 .0001). The surgical site infection rate was significantly higher in the open group compared with the arthroscopic group (0.5% vs 0.2%, NNT 333.3, p < 0 .001). Patient and provider covariates had no statistically significant effect on revision rates, aside from increasing age (per 10 year increase, HR 0.85, 0.81–0.90 95% CI, p < 0 .0001). Revision rotator cuff repair is approximately 30% more common in patients undergoing arthroscopic repair, in comparison to open repair, after adjustment. Surgical site infection is uncommon regardless of surgical technique, however, it is slightly more common following open repair. In the setting of an economic healthcare crisis, trends of increasing arthroscopic RCR may demand scrutiny, as the technique is associated with higher revision rates and higher costs


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 50 - 50
1 Apr 2018
Kim Y Kim Y Hwang K Moon J
Full Access

Purpose. The posterolateral or posterior approach for total hip arthroplasty has the advantages of preserving the hip abductor musculature and providing good visualization during femoral preparation and component insertion. Although posterolateral approach is one of the popular approaches in hip arthroplasty, it has been reported high dislocation rate as a drawback. To compensate the drawback the repair of short external rotator of hip is thought to be important. Therefore, we investigated incidence of failed repaired short external rotator muscles, dislocation rate and time of failure between tendon to tendon and tendon to bone repair technique through prospective study more than 1 year follow up. Materials and methods. We performed 213 hip arthroplasties in 202 patients from May 2012 to January 2015. After exclusion of 15 hips due to follow-up loss(9 hips), death(2 hips), greater trochanteric fragment displacement(3 hips) and severe contracted short external rotator(1 hip), we investigated 198 hips in 187 patients. 57 patients were male and 130 patients were female. The mean age of patient was 70.4 (32–98) years. Reattachment short external rotator with posterior capsule to postero-superior aspect of greater trochanter(tendon to bone group, 111 hips) or to the tendon(tendon to tendon group, 87 hips) was performed. Two No.26 metal wire markers were fixed at the greater trochanter tip and short external rotator tendon respectively with a distance less than 1.2cm, and the distance between two wire markers was observed at postoperative 1 day, 2 weeks, 3 months, and annually radiographs in neutral position. When the distance was more than 2.5cm or one of the wire markers was invisible, we defined them the failure of short external rotator repair. The mean follow up period was 28.8 (12–45) months. Results. Failure rate of tendon to bone repair technique(17.1%) was significantly less as compared to that of tendon to tendon repair technique(70.1%)(p<0.001). The failure of short external rotator repair happened mostly within postoperative 2 weeks, which was 89.5% in tendon to bone(p=0.025) and 93.4% in tendon to tendon repair (p<0.001). Dislocation was observed in 2 (1.8%) hips in tendon to bone repair group and in 7 (8.0%) hips in tendon to tendon repair group respectively, which was significantly higher dislocation rate in tendon to tendon repair group. A significant correlation was also observed between failure of short external rotator repair and dislocation (p=0.032). Conclusions. Tendon to bone repair technique is superior to tendon to tendon technique in terms of failure rate of short external rotator repair in hip arthroplasty. Tendon to bone repair of short external rotator with posterior capsule was beneficial to reduce dislocation rate as compared with tendon to tendon repair technique. As majority of failure of short external rotator happened within postoperative 2 weeks, restriction of internal rotation should be recommended through the period


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 28 - 28
4 Apr 2023
Bolam S Park Y Konar S Callon K Workman J Monk P Coleman B Cornish J Vickers M Munro J Musson D
Full Access

Obesity is associated with poor outcomes and increased risk of failure after rotator cuff (RC) repair surgery. The effect of diet-induced obesity (DIO) on enthesis healing has not been well characterised and whether its effects can be reversed with dietary intervention is unknown. We hypothesised that DIO would result in inferior enthesis healing in a rat model of RC repair and that dietary intervention in the peri-operative period would improve enthesis healing. A total of 78 male Sprague-Dawley rats were divided into three weight-matched groups from weaning and fed either: control diet (CD), high-fat diet (HFD), or HFD until surgery, then CD thereafter (HF-CD). After 12 weeks the left supraspinatus tendon was detached, followed by immediate surgical repair. At 2 and 12 weeks post-surgery, animals were cullers and RCs harvested for biomechanical and histological evaluation. Body composition and metabolic markers were assessed via DEXA and plasma analyses, respectively. DIO was established in the HFD and HF-CD groups prior to surgery, and subsequently reversed in the HF-CD group after surgery. At 12 weeks post-surgery, plasma leptin concentrations were higher in the HFD group compared to the CD group (5.28 vs. 2.91ng/ml, P=0.003). Histologically, the appearance of the repaired entheses was poorer in both the HFD and HF-CD compared to the CD group at 12 weeks (overall histological score 6.20 (P=0.008), 4.98 (P=0.001) and 8.68 out of 15, respectively). The repaired entheses in the HF-CD group had significantly lower (26.4 N, P=0.028) load-at-failure 12 weeks post-surgery compared to the CD group (34.4 N); while the HFD group was low, but not significantly different (28.1 N, P=0.096). Body mass at the time of surgery, plasma leptin and body fat percentage were negatively correlated with histological scores and plasma leptin with load-at-failure 12 weeks post-surgery. DIO impaired enthesis healing in this rat RC repair model, with inferior biomechanical and histological outcomes. Restoring normal weight with dietary change after surgery did not improve healing outcomes. Exploring interventions that improve the metabolic state of obese patients and counselling patients appropriately about their modest expectations after repair should be considered


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 83 - 83
23 Feb 2023
Rossignol SL Boekel P Grant A Doma K Morse L
Full Access

Currently, the consensus regarding subscapularis tendon repair during a reverse total shoulder arthroplasty (rTSA) is to do so if it is possible. Repair is thought to decrease the risk of dislocation and improve internal rotation but may also increase stiffness and improvement in internal rotation may be of subclinical benefit. Aim is to retrospectively evaluate the outcomes of rTSA, with or without a subscapularis tendon repair. We completed a retrospective review of 51 participants (25 without and 26 with subscapularis repair) who received rTSR by a single-surgeon using a single-implant. Three patient reported outcome measures (PROM) were assessed pre-operatively and post-operative at twelve months, as well as range of movement (ROM) and plain radiographs. Statistical analysis utilized unpaired t tests for parametric variables and Mann-Whitney U test for nonparametric variables. External Rotation ROM pre-operatively was the only variable with a significance difference (p=0.02) with the subscapularis tendon repaired group having a greater range. Pre- and post-operative abduction (p=0.72 & 0.58), forward flexion (p=0.67 & 0.34), ASES (p=0.0.06 & 0.78), Oxford (p=0.0.27 & 0.73) and post-operative external rotation (p=0.17). Greater external rotation ROM pre-operatively may be indicative of the ability to repair the subscapularis tendon intra-operatively. However, repair does not seem to improve clinical outcome at 12 months. There was no difference of the PROMs and AROMs between the subscapularis repaired and not repaired groups for any of the variables at the pre-operative or 12 month post operative with the exception of the external rotation ROM pre-operatively. We can conclude that from PROM or AROM perspective there is no difference if the tendon is repaired or not in a rTSR and indeed the patients without the repair may have improved outcomes at 12 months


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 32 - 32
2 Jan 2024
Traweger A
Full Access

Approximately 30% of general practice consultations for musculoskeletal pain are related to tendon disorders, causing substantial personal suffering and enormous related healthcare costs. Treatments are often prone to long rehabilitation times, incomplete functional recovery, and secondary complications following surgical repair. Overall, due to their hypocellular and hypovascular nature, the regenerative capacity of tendons is very poor and intrinsically a disorganized scar tissue with inferior biomechanical properties forms after injury. Therefore, advanced therapeutic modalities need to be developed to enable functional tissue regeneration within a degenerative environment, moving beyond pure mechanical repair and overcoming the natural biological limits of tendon healing. Our recent studies have focused on developing biologically augmented treatment strategies for tendon injuries, aiming at restoring a physiological microenvironment and boosting endogenous tissue repair. Along these lines, we have demonstrated that the local application of mesenchymal stromal cell-derived small extracellular vesicles (sEVs) has the potential to improve rotator cuff tendon repair by modulating local inflammation and reduce fibrotic scarring. In another approach, we investigated if the local delivery of the tendon ECM protein SPARC, which we previously demonstrated to be essential for tendon maturation and tissue homeostasis, has the potential to enhance tendon healing. Finally, I will present results demonstrating the utility of nanoparticle-delivered, chemically modified mRNAs (cmRNA) to improve tendon repair


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 39 - 39
4 Apr 2023
Lim W Lie D Chou S Lie H Yew A
Full Access

This study aims to investigate the mechanical properties of a rotator cuff tear repaired with a polypropylene interposition graft in an ovine infraspinatus ex-vivo model. Twenty fresh shoulders from skeletally mature sheep were used in this study. A tear size of 20 mm from the tendon joint was created in the infraspinatus tendon to simulate a large tear in fifteen specimens. This was repaired with a polypropylene mesh used as an interposition graft between the ends of the tendon. Eight specimens were secured with mattress stitches while seven were secured to the remnant tendon on the greater tuberosity side by continuous stitching. Remaining five specimens with an intact tendon served as a control group. All specimens underwent cyclic loading with a universal testing machine to determine the ultimate failure load and gap distance. Gap distance increased with progressive cyclic loading through 3000 cycles for all repaired specimens. Mean gap distance after 3000 cycles for both continuous and mattress groups are 1.7 mm and 4.2 mm respectively (P = .001). Significantly higher mean ultimate failure load was also observed with 549.2 N in the continuous group, 426.6 N in the mattress group and 370 N in the intact group. The use of a polypropylene mesh as an interposition graft for large irreparable rotator cuff tears is biomechanically suitable and results in a robust repair that is comparable to an intact rotator cuff tendon. When paired with a continuous suturing technique, it demonstrates significantly resultant superior biomechanical properties that may potentially reduce re-tear rates after repairing large or massive rotator cuff tears


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 80 - 80
23 Feb 2023
Bolam S Park Y Konar S Callon K Workman J Monk A Coleman B Cornish J Vickers M Munro J Musson D
Full Access

We hypothesised that diet-induced obesity (DIO) would result in inferior enthesis healing in a rat model of rotator cuff (RC) repair and that dietary intervention in the peri-operative period would improve enthesis healing. A total of 78 male Sprague-Dawley rats were divided into three weight-matched groups from weaning and fed either: control diet (CD), high-fat diet (HFD), or HFD until surgery, then CD thereafter (HF-CD). After 12 weeks, the left supraspinatus tendon was detached, followed by immediate surgical repair. At 2 and 12 weeks post-surgery, animals were culled, and RCs harvested for biomechanical and histological evaluation. Body composition and metabolic markers were assessed via DEXA and plasma analyses, respectively. DIO was established in the HFD and HF-CD groups before surgery and subsequently reversed in the HF-CD group after surgery. Histologically, the appearance of the repaired entheses was poorer in both the HFD and HF-CD groups compared with the CD group at 12 weeks after surgery, with semiquantitative scores of 6.2 (P<0.01), 4.98 (P<0.01), and 8.7 of 15, respectively. The repaired entheses in the HF-CD group had a significantly lower load to failure (P=0.03) at 12 weeks after surgery compared with the CD group, while the load to failure in the HFD group was low but not significantly different (P=0.10). Plasma leptin were negatively correlated with histology scores and load to failure at 12 weeks after surgery. DIO impaired enthesis healing in this rat RC repair model, with inferior biomechanical and histological outcomes. Restoring normal weight with dietary change after surgery did not improve healing outcomes. Circulating levels of leptin significantly correlated with poor healing outcomes. This pre-clinical rodent model demonstrates that obesity is a potentially modifiable factor that impairs RC healing and increases the risk of failure after RC surgery


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 11 - 11
1 Dec 2022
Bergomi A Adriani M De Filippo F Manni F Motta M Saccomanno M Milano G
Full Access

Rotator cuff repair has excellent clinical outcomes but continues to be a challenge when it comes to large and massive tears as well as revision procedures. Reported symptomatic retear rates are still too high to be acceptable. The purpose of the present study was to evaluate the effectiveness of a combination of augmentation techniques consisting of microfractures of the greater tuberosity, extracellular matrix (ECM) patch graft and subsequent platelet concentrate (PC) subacromial injections in revision rotator cuff repair. The study was designed as a retrospective comparative study on prospectively collected data from a consecutive cohort of patients. All patients who underwent arthroscopic revision rotator cuff repair for symptomatic failure of previous posterosuperior rotator cuff repair were considered eligible for the study. Symptomatic failure had been diagnosed according to clinical examination and confirmed by magnetic resonance imaging (MRI). Structural integrity had been assessed on MRI and classified according to Sugaya classification. Only patients affected by stage IV-V were considered eligible. Tear reparability was confirmed during arthroscopy. Only patients with a minimum 2 years follow-up were included. Patients were divided in two groups. In group 1 (control group) a standard arthroscopic revision and microfractures of the greater tuberosity were performed; in group 2 (experimental group), microfractures of the greater tuberosity and a ECM patch graft were used to enhance tendon repair, followed by postoperative PC injections. Minimum follow-up was 12 months. Primary outcome was the Constant-Murley score (CMS) normalized for age and gender. Subjective outcome was assessed with the Disabilities of the Arm, Shoulder and Hand (DASH) score in its short version (Quick-DASH). Tendon integrity was assessed with MRI at 6 months after surgery. Comparison between groups for all discrete variables at baseline and at follow-up was carried out with the Student's t-test for normally distributed data, otherwise Mann-Whitney U-test was used. Within-group differences (baseline vs follow-up) for discrete variables were analyzed by paired t-test, or by Wilcoxon signed-rank test in case of data with non-normal distribution. Differences for categorical variables were assessed by chi-squared test. Significance was considered for p values < 0.05. Forty patients were included in the study (20 patients for each group). The mean follow-up was 13 ± 1.6 months. No patients were lost at the follow up. Comparison between groups did not show significant differences for baseline characteristics. At follow-up, mean CMS was 80.7 ± 16.6 points in group 1 and 91.5 ± 11.5 points in group 2 (p= 0.022). Mean DASH score was 28.6 ± 21.6 points in group 1 and 20.1 ± 17.4 points in group 2 (p= 0.178). Post-operative MRI showed 6 healed shoulders in Group 1 and 16 healed shoulders in Group 2 (p<0.004). No postoperative complications were reported in both groups. The combination of microfractures of the greater tuberosity, ECM patch graft, and subsequent PC subacromial injections is an effective strategy in improving tendon healing rate


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 86 - 86
7 Aug 2023
Nanjundaiah R Guro R Chandratreya A Kotwal R
Full Access

Abstract. Aims. We studied the outcomes following arthroscopic primary repair of bucket handle meniscus tears to determine the incidence of re-tears and the functional outcomes of these patients. Methodology. Prospective cohort study. Over a 4-year period (2016 to 2020), 35 adult patients presented with a bucket handle tear of the meniscus. Arthroscopic meniscal repair was performed using either the all inside technique or a combination of all-inside and inside-out techniques. 15 patients also underwent simultaneous arthroscopic anterior cruciate ligament reconstruction. Functional knee scores were assessed using IKDC and Lysholm scores. Results. Mean patient age at surgery was 27 years (range, 17 to 53years). Medial meniscus was torn in 20 and lateral in 15 cases. Zone of tear was white on white in 19, red on white in 9 and red on red in 7 cases. Average delay from injury to surgery was 4 months. At a mean follow-up of 4.5 years, the meniscus repair failed in 3 patients (8.5 %). Outcome following re-tear was meniscus excision. Average IKDC scores in patients with intact repair were 74.04 against 56.67 in patients with a failed repair (p< 0.0001). Similarly, Lyshlom scores were 88.96 and 67.333, respectively (p<0.0001). Conclusion. The survivorship of primary repair of bucket handle meniscus tears in our series was 91.5% at medium term follow-up. Functional outcomes were significantly poor in patients with a failed repair compared to those with an intact repair


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 80 - 80
11 Apr 2023
Oliveira J Simões J Noronha J Ramos A
Full Access

Validation of a new meniscal root repair technique that will be biomechanically superior to current gold standard procedures and, at the same time, will allow controlled adjustable fixation. Medial and lateral meniscus from 10 porcine knees were collected. An iatrogenic posterior root tear was created and a single transosseous tibial tunnel technique that closely replicates the repair procedure with a 2-mm-wide-knottable braided tape was performed. Randomly, in one group (A) two simple cinch stitch were applied to suture the posterior root of the meniscus and, in the other group (B), a simple stich that holds the meniscus in two points in a crosse match configuration was used. For final fixation, alternating surgeon's knots (A group) and a doubled suture knot that allows an adjustable fixation were used (B group). All repairs were standardized for location and the repair stiches were placed in the body of the meniscus. The new suture configuration (B group) showed a better biomechanical performance in terms of load for both the medial [151,0-560,3] 306,9±173,8N and the lateral posterior root fixation [268,2-463,1] 347,4±74,3N in comparison to the cinch stitch (A group) [219,0-365,2] 268,9±58,7N and [219,0-413,6] 318,0±72N. The maximum stiffness was also higher for the new tested suture configuration (B group) for both the medial meniscus [10,6-34,5] 18,9±9,2N/mm vs [7,1-12,7] 10,9±2,2N/mm and the lateral meniscus [16,0-27,9] 21,6±5,5N/mm vs [7,6-15,6] 12,6±3,5N/mm. The presented new meniscal root repair is biomechanically superior to current gold standard techniques, as the cinch stich made with tape, keeping the simplicity and reproducibility of the procedure and, at the same time, is economically advantageous since a single tape in needed and allows adjustable fixation of the repair over a button


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 72 - 72
1 Dec 2022
Lamer S Ma Z Mazy D Chung-Tze-Cheong C Nguyen A Li J Nault M
Full Access

Meniscal tears are the most common knee injuries, occurring in acute ruptures or in chronic degenerative conditions. Meniscectomy and meniscal repair are two surgical treatment options. Meniscectomy is easier, faster, and the patient can return to their normal activities earlier. However, this procedure has long-term consequences in the development of degenerative changes in the knee, potentially leading to knee replacement. On the other hand, meniscal repair can offer prolonged benefits to the patients, but it is difficult to perform and requires longer rehabilitation. Sutures are used for meniscal repairs, but they have limitations. They induce tissue damage when passing through the meniscus. Furthermore, under dynamic loading of the knee, they can cause tissue shearing and potentially lead to meniscal repair failure. Our team has developed a new technology of resistant adhesive hydrogels to coat the suture used to repair meniscal tissue. The objective of this study is to biomechanically compare two suture types on bovine menisci specimens: 1) pristine sutures and 2) gel adhesive puncture sealing (GAPS) sutures, on a repaired radial tear under cyclic tensile testing. Five bovine knees were dissected to retrieve the menisci. On the 10 menisci, a complete radial tear was performed. They were separated in two groups and repaired using either pristine (2-0 Vicryl) or GAPS (2-0 Vicryl coated with adhesive hydrogels) with a single stitch and five knots. The repaired menisci were clamped on an Instron machine. The specimens were cyclically preconditioned between one and 10 newtons for 10 cycles and then cyclically loaded for 500 cycles between five and 25 newtons at a frequency of 0.16 Hz. The gap formed between the edges of the tear after 500 cycles was then measured using an electronic measurement device. The suture loop before and after testing was also measured to ensure that there was no suture elongation or loosening of the knot. The groups were compared statistically using Mann-Whitney tests for nonparametric data. The level of significance was set to 0.05. The mean gap formation of the pristine sutures was 5.61 mm (SD = 2.097) after 500 cycles of tensile testing and 2.38 mm (SD = 0.176) for the GAPS sutures. Comparing both groups, the gap formed with the coated sutures was significantly smaller (p = 0.009) than with pristine sutures. The length of the loop was equal before and after loading. Further investigation of tissue damage indicated that the gap was formed by suture filament cutting into the meniscal tissue. The long-term objective of this research is to design a meniscal repair toolbox from which the surgeon can adapt his procedure for each meniscal tear. This preliminary experimentation on bovine menisci is promising because the new GAPS sutures seem to keep the edges of the meniscal tear together better than pristine sutures, with hopes of a clinical correlation with enhanced meniscal healing


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 66 - 66
1 Dec 2022
Lamer S Ma Z Mazy D Chung-Tze-Cheong C Nguyen A Li J Nault M
Full Access

Meniscal tears are the most common knee injuries, occurring in acute ruptures or in chronic degenerative conditions. Meniscectomy and meniscal repair are two surgical treatment options. Meniscectomy is easier, faster, and the patient can return to their normal activities earlier. However, this procedure has long-term consequences in the development of degenerative changes in the knee, potentially leading to knee replacement. On the other hand, meniscal repair can offer prolonged benefits to the patients, but it is difficult to perform and requires longer rehabilitation. Sutures are used for meniscal repairs, but they have limitations. They induce tissue damage when passing through the meniscus. Furthermore, under dynamic loading of the knee, they can cause tissue shearing and potentially lead to meniscal repair failure. Our team has developed a new technology of resistant adhesive hydrogels to coat the suture used to repair meniscal tissue. The objective of this study is to biomechanically compare two suture types on bovine menisci specimens: 1) pristine sutures and 2) gel adhesive puncture sealing (GAPS) sutures, on a repaired radial tear under cyclic tensile testing. Five bovine knees were dissected to retrieve the menisci. On the 10 menisci, a complete radial tear was performed. They were separated in two groups and repaired using either pristine (2-0 Vicryl) or GAPS (2-0 Vicryl coated with adhesive hydrogels) with a single stitch and five knots. The repaired menisci were clamped on an Instron machine. The specimens were cyclically preconditioned between one and 10 newtons for 10 cycles and then cyclically loaded for 500 cycles between five and 25 newtons at a frequency of 0.16 Hz. The gap formed between the edges of the tear after 500 cycles was then measured using an electronic measurement device. The suture loop before and after testing was also measured to ensure that there was no suture elongation or loosening of the knot. The groups were compared statistically using Mann-Whitney tests for nonparametric data. The level of significance was set to 0.05. The mean gap formation of the pristine sutures was 5.61 mm (SD = 2.097) after 500 cycles of tensile testing and 2.38 mm (SD = 0.176) for the GAPS sutures. Comparing both groups, the gap formed with the coated sutures was significantly smaller (p = 0.009) than with pristine sutures. The length of the loop was equal before and after loading. Further investigation of tissue damage indicated that the gap was formed by suture filament cutting into the meniscal tissue. The long-term objective of this research is to design a meniscal repair toolbox from which the surgeon can adapt his procedure for each meniscal tear. This preliminary experimentation on bovine menisci is promising because the new GAPS sutures seem to keep the edges of the meniscal tear together better than pristine sutures, with hopes of a clinical correlation with enhanced meniscal healing


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_3 | Pages 8 - 8
23 Jan 2024
Nanjundaiah R Guro R Chandratreya A Kotwal R
Full Access

Aims. We studied the outcomes following arthroscopic primary repair of bucket handle meniscus tears to determine the incidence of re-tears and the functional outcomes of these patients. Methodology. Prospective cohort study. Over a 4-year period (2016 to 2020), 35 adult patients presented with a bucket handle tear of the meniscus. Arthroscopic meniscal repair was performed using either the all inside technique or a combination of all-inside and inside-out techniques. 15 patients also underwent simultaneous arthroscopic anterior cruciate ligament reconstruction. Functional knee scores were assessed using IKDC and Lysholm scores. Results. Mean patient age at surgery was 27 years (range, 17 to 53years). Medial meniscus was torn in 20 and lateral in 15 cases. Zone of tear was white on white in 19, red on white in 9 and red on red in 7 cases. Average delay from injury to surgery was 4 months. At a mean follow-up of 4.5 years, the meniscus repair failed in 3 patients (8.5 %). Outcome following re-tear was meniscus excision. Average IKDC scores in patients with intact repair were 74.04 against 56.67 in patients with a failed repair (p< 0.0001). Similarly, Lyshlom scores were 88.96 and 67.333, respectively (p<0.0001). Conclusion. The survivorship of primary repair of bucket handle meniscus tears in our series was 91.5% at medium term follow-up. Functional outcomes were significantly poor in patients with a failed repair compared to those with an intact repair


Full Access

To evaluate the impact of routine capsular repair on patient-reported outcomes, survivorship and achievability of clinically important improvement, minimum 5-years post-surgery. Our prospective institutional registry was reviewed for cases undergoing primary HA for FAI, and stratified into two groups depending on whether the capsule was repaired or not. Routine repair was introduced in late 2013. The No Repair group consisted of patients undergoing HA between Jan 2010-June 2013 while the Repair group consisted of patients undergoing HA between Jan 2015-Sept 2018. Exclusion criteria consisted of >50 years, Tonnis>1, dysplasia(LCEA<25), concomitant hip pathologies. PROMs consisted of mHHS, SF36 and UCLA. Metrics of clinically important improvement was evaluated using MCID and SCB. Rates of repeat HA or THA conversion were recorded. 985 cases were included (359 No Repair; 626 Repair), 86% male, average age 27.4±6.7years. Significant improvement in all PROMs at minimum 5-years was observed for both groups (p<0.001 for all; large effect sizes for mHHS and SF36, medium effect sizes for UCLA). At 5-years post-op there was no significant difference between groups for mHHS(p=0.078) or UCLA(0.794). SF36 was significantly poorer for those cases undergoing routine repair(p<0.001) however effect size was small (0.20). Thresholds of MCID and SCB were calculated as 69% and 86% for mHHS, 64% and 77% for UCLA, 43% and 60% for SF36. Both groups achieved MCID and SCB at similar rates for mHHS and UCLA. A significantly lower proportion of cases in the repair groups achieved MCID for SF36 (53.6% vs 63.5%, p=0.034) and SCB for SF36 (37.3% vs 52.8%, p<0.001). No significant difference between groups for THA conversion (0.6% No Repair vs 0.5% Repair) or repeat HA (9.7% No Repair vs 8.1% Repair). Routinely repairing the capsule following HA for FAI demonstrates no clinical benefit over not repairing the capsule 5 years post-surgery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 136 - 136
2 Jan 2024
Seah M Birch M Moutsopoulos I Mohorianu I McCaskie A
Full Access

Despite osteoarthritis (OA) representing a large burden for healthcare systems, there remains no effective intervention capable of regenerating the damaged cartilage in OA. Mesenchymal stromal cells (MSCs) are adult-derived, multipotent cells which are a candidate for musculoskeletal cell therapy. However, their precise mechanism of action remains poorly understood. The effects of an intra-articular injection of human bone-marrow derived MSCs into a knee osteochondral injury model were investigated in C57Bl/6 mice. The cell therapy was retrieved at different time points and single cell RNA sequencing was performed to elucidate the transcriptomic changes relevant to driving tissue repair. Mass cytometry was also used to study changes in the mouse immune cell populations during repair. Histological assessment reveals that MSC treatment is associated with improved tissue repair in C57Bl/6 mice. Single cell analysis of retrieved human MSCs showed spatial and temporal transcriptional heterogeneity between the repair tissue (in the epiphysis) and synovial tissue. A transcriptomic map has emerged of some of the distinct genes and pathways enriched in human MSCs isolated from different tissues following osteochondral injury. Several MSC subpopulations have been identified, including proliferative and reparative subpopulations at both 7 days and 28 days after injury. Supported by the mass cytometry results, the immunomodulatory role of MSCs was further emphasised, as MSC therapy was associated with the induction of increased numbers of regulatory T cells correlating with enhanced repair in the mouse knee. The transcriptomes of a retrieved MSC therapy were studied for the first time. An important barrier to the translation of MSC therapies is a lack of understanding of their heterogeneity, and the consequent lack of precision in its use. MSC subpopulations with different functional roles may be implicated in the different phases of tissue repair and this work offers further insights into repair process


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 39 - 39
17 Apr 2023
Saiz A O'Donnell E Kellam P Cleary C Moore X Schultz B Mayer R Amin A Gary J Eastman J Routt M
Full Access

Determine the infection risk of nonoperative versus operative repair of extraperitoneal bladder ruptures in patients with pelvic ring injuries. Pelvic ring injuries with extraperitoneal bladder ruptures were identified from a prospective trauma registry at two level 1 trauma centers from 2014 to 2020. Patients, injuries, treatments, and complications were reviewed. Using Fisher's exact test with significance at P value < 0.05, associations between injury treatment and outcomes were determined. Of the 1127 patients with pelvic ring injuries, 68 (6%) had a concomitant extraperitoneal bladder rupture. All patients received IV antibiotics for an average of 2.5 days. A suprapubic catheter was placed in 4 patients. Bladder repairs were performed in 55 (81%) patients, 28 of those simultaneous with ORIF anterior pelvic ring. The other 27 bladder repair patients underwent initial ex-lap with bladder repair and on average had pelvic fixation 2.2 days later. Nonoperative management of bladder rupture with prolonged Foley catheterization was used in 13 patients. Improved fracture reduction was noted in the ORIF cohort compared to the closed reduction external fixation cohort (P = 0.04). There were 5 (7%) deep infections. Deep infection was associated with nonoperative management of bladder rupture (P = 0.003) and use of a suprapubic catheter (P = 0.02). Not repairing the bladder increased odds of infection 17-fold compared to repair (OR 16.9, 95% CI 1.75 – 164, P = 0.01). Operative repair of extraperitoneal bladder ruptures substantially decreases risk of infection in patients with pelvic ring injuries. ORIF of anterior pelvic ring does not increase risk of infection and results in better reductions compared to closed reduction. Suprapubic catheters should be avoided if possible due to increased infection risk later. Treatment algorithms for pelvic ring injuries with extraperitoneal bladder ruptures should recommend early bladder repair and emphasize anterior pelvic ORIF