Aims. The
Aims. The modified Radiological Union Scale for Tibia (mRUST) fractures score was developed in order to assess progress to union and define a numerical assessment of fracture healing of metadiaphyseal fractures. This score has been shown to be valuable in predicting radiological union; however, there is no information on the
16 to 34% of the population suffer from shoulder pain, the most common cause being rotator cuff tears. NICE guidance recommends using ultrasound scan (USS) or MRI to assess these patients, but does not specify which is preferable. This study assesses the accuracy of USS and MRI in rotator cuff tears in a DGH, to establish the most appropriate imaging modality. Patients who had at least two of shoulder ultrasound, MRI or arthroscopy within a seven month period (n=55) were included in this retrospective study.
Variations in component positioning of total hip replacements can lead to edge loading of the liner, and potentially affect device longevity. These effects are evaluated using ISO 14242:4 edge loading test results in a dynamic system. Mediolateral translation of one of the components during testing is caused by a compressed spring, and therefore the kinematics will depend on the spring stiffness and damping coefficient, and the mass of the translating component and fixture. This study aims to describe the
Abstract. Background. Prosthetic joint infection (PJI) is a significant cause of morbidity and mortality following knee replacement surgery. Identifying the causative agent(s) and their antibiotic
Magnetic resonance imaging (MRI) is a useful diagnostic tool in evaluating meniscus pathology in the knee. Data from available literature suggests
The role of metal
FAI has been implicated in the progression of osteoarthritis (OA) and early detection may allow for treatment, which can slow or halt progression. FAI is a difficult condition to image and there is little objective evidence about imaging accuracy. We aim to measure the accuracy of five imaging modalities. Three blinded observers retrospectively reviewed five different modalities from two age and sex matched groups: A patient group referred to the outpatient clinic with a clinical diagnosis of FAI and a control group who had had CT scans of the pelvis for suspected trauma, where the Pelvic scan had been reported as showing no injuries. The imaging modalities were: Standard x-ray; Antero-Posterior, Lateral; Condition-specific x-ray projections; Dunn view, lateral internal rotation; Standard Computer Tomography (CT) multiplanar reconstruction (MPR); axial, sagittal and coronal; Condition-specific CT MPR; angled axial, angled coronal; 3D modelling; and surface rendered dynamic. We found marked variations in the
Introduction. Metals used for total knee arthroplasty (TKA) are well known for their good biocompatibility, but may be a source of a release of metal ions that can be a cause of local and systemic adverse effects, aseptic loosening, and hypersensitivity reactions. One of the major difficulties in performing TKA is the selection of implants for patients who are preoperatively diagnosed as subject to metal
The success of total knee replacement surgery depends critically on proper limb alignment and implant position. Even with contemporary mechanical alignment instrumentation, errors in limb alignment and implant position do occur. To improve upon the accuracy and biomechanical efficacy of conventional surgical instrumentation while limiting the need for substantial pre-operative planning, a non-image-based computer-aided navigation system was developed for total knee replacement surgery. Clinical studies have demonstrated that use of this system, OrthoPilot® (Aesculap AG, Tuttlingen, Germany), for knee replacement surgery can lead to improved limb alignment and implant position. In this study we investigated the repeatability and
In spite of its incidence decreasing to 1% nowadays, prosthesis-related infections remain a research, diagnostic, therapeutic and cost-related problem. Early diagnosis, selection of an appropriate surgical strategy, accurate identification of the responsible microorganisms and construction of an appropriate antibiotic regimen are essential elements of any management strategy. Our study aim was firstly to compare the diagnostic accuracy of conventional periprosthetic tissue culture and culture of fluid derived from vortexing and bath sonication of the explanted hardware and secondly to investigate the role of possible metabolic factors affecting the
Computational modeling has been used to simulate the natural and prosthetic kinematic and kinetic function in an attempt to compare designs and/or predict a desired motion path from a design. The levels of soft tissue can range from basic ligaments (MCL, LCL, and ACL & PCL) to more complex models. The goal of this study was to evaluate the
The kinematic and kinetic characteristics of the knee after TKR are known to be strongly influenced by the alignment and positioning of the implanted components. In this paper we apply a virtual multi-fiber ligament model to a rigid body model of the post-surgical knee to explore how variations in alignment and positioning affect the predicted behavior of the ligaments and contact forces. We vary the angular and translational positioning of the femoral and tibial TKR components relative to the bone. Meanwhile the proximal and distal insertion sites of the ligaments are held constant relative to the bony structures. We evaluate
The peak external knee adduction moment during walking gait has been proposed to be a clinically useful measure of dynamic knee joint load in patients with knee osteoarthritis. However, there is limited information about the reliability of this measure, or its ability to detect change. The test-retest reliability and
Introduction. Scar
Introduction. The influence of the bone mineral density (BMD) on the mechanical behavior of bones can be examined using computer tomography (CT) data and finite element (FE) simulations, because the BMD correlates with the Hounsfield scale (HU) of the CT data. Therefor the material mapping strategy, which is required to assign the HU values to the FE mesh, is of crucial importance. In this study a nodal mapping strategy was analyzed concerning its
The purpose of the project was to develop a questionnaire for completion by patients with elbow pathologies which is short and practical, internally consistent, valid, responsive and sensitive to changes of clinical importance. The first, pilot phase included 43 patients who each completed a 19 item questionnaire relating to elbow function. The 19 ADLs produced a total scale Cronbach Alpha of 0.96., two different groups of ADLs were identified by multivariate analysis. Group 1 consisted of ADLs requiring moderate to high isometric loading and Group 2 of ADLs requiring high flexion. From the 19 items the best 10 which represented both groups were selected. A summary score was used to create the Wrightington Elbow Disability Score (WEDS). In the second phase 89 patients completed the new WEDS form, reliability studies produced a Cronbach’s alpha value of 0.91. Internal validity of the groups of ADLs all correlated at p<
0.001 level with strength (Group1) and flexion (Group 2). A sub set of 40 patients undergoing total elbow arthroplasty were assessed for
Optimal soft tissue tension maximises function following total knee arthroplasty. Excessive tension may lead to stiffness and or pain, while inadequate tension can lead to instability. Composite component thickness is a prime determinant of this soft tissue tension. The variable component thickness provided by polyethylene inserts generally allows for 2–3mm incremental change. This study analyzed the effect of 1-mm incremental changes in polyethylene thickness on soft tissue tension. Our hypothesis was that soft tissue tension would be markedly affected by increases in insert thickness. Computer assisted TKA was performed on eight cadaveric knee specimens (four pairs). The knees were passively moved through full flexion-extension range of motion, for each tibial construct thickness. Kinematics were recorded using the computer navigation software. Soft tissue tension was analyzed by measuring compartmental loads. A validated load cell instrumented tibial insert was used to measure medial and lateral compartmental loads independently. The effect of 1-mm increments in polyethylene thickness on compartmental loads was evaluated. An increase in compartmental loads was measured with increasing insert thickness. Loading in contralateral compartments showed differing behaviour, reflecting varying tension in the medial and lateral sides. Many generated loads showed a reduction after reaching a maximal level with further increase in insert thickness (seven of eight specimens), indicative of tissue failure, although there were no overt indications of failure during the procedure. With a 1-mm increase in insert thickness, six of eight specimens showed an increase in peak loads greater than 100N at some point in the testing procedure, although not always with the same shim thickness. Compartmental loads varied as a function of insert thickness. Most specimens showed signs of soft tissue “micro-failure”. The high
ARMD (Adverse Reaction to Metal Debris) is an increasingly recognised complication of metal on metal hip replacements. The MHRA (Medical and Healthcare Related Devices Agency) have advised a blood cobalt or chromium level above 7 mg/L is a threshold for further investigation, stating that “low levels are reassuring and strongly predict not having an adverse outcome”. Cross-sectional imaging should be performed when levels are above 7 mg/L. We have performed a study investigating the specificity and
We have demonstrated that toxins produced by Staphylococcus aureus, a common infective agent in septic arthritis (SA), cause rapid in situ chondrocyte death. Here, we have compared the