Results 1 - 20 of 5008
Results per page:

Abstract. Objectives. Hip instability following total hip arthroplasty in treatment of intracapsular neck of femur fractures is reported at 8–11%. Utilising the principle of a small articulation to minimize the problems of wear coupled with a large articulation, dual-mobility total hip arthroplasty prostheses stabilise the hip further than conventional fixed-bearing designs. The aim of this study is to compare the rate of dislocation and complication between standard fixed-bearing and dual-mobility prostheses for the treatment of intracapsular neck of femur fractures. Methods. A four-year retrospective review in a large district general hospital was completed. All cases of intracapsular neck of femur fractures treated with total hip arthroplasty were identified through the theatre logbooks. Patient's operative and clinical notes were retrospectively reviewed to collect data. Results. A total of 91 patients underwent total hip arthroplasty for intracapsular neck of femur fracture in the four-year period. 61.5% were dual-mobility design versus 28.5% had fixed-bearing implants. There were no statistical differences between patient group characteristics. Choice of implant was dependent on surgeon preference. There was a 0.0% dislocation rate in the dual-mobility group versus 8.6% in the fixed-bearing prosthesis group. All dislocations occurred in patients who underwent total hip arthroplasty with 36.0mm fixed-bearing prosthesis via posterior surgical approach. There was no statistical difference in mortality between both groups. Conclusion. There was an increasing trend of towards the use of dual-mobility prosthesis for fractured neck of femur within this department with excellent outcomes. Dual-mobility designs provide reduced dislocation rates in total hip arthroplasty in intracapsular neck of femur fractures compared to standard fixed-bearing designs at this institution. The authors recommend that all orthopaedic staff consider the use of dual-mobility prostheses in suitable patients and ensure trainees are suitably trained in use of dual-mobility designs. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Bone & Joint Open
Vol. 4, Issue 1 | Pages 3 - 12
4 Jan 2023
Hardwick-Morris M Twiggs J Miles B Al-Dirini RMA Taylor M Balakumar J Walter WL

Aims. Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation. Methods. This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months’ follow-up. 3D models of each patient’s prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model’s sensitivity, specificity, and area under the curve (AUC). Results. Highly significant differences between the symptomatic and asymptomatic cohorts were observed for iliopsoas impingement. Logistic regression models determined that the impingement values significantly predicted the probability of groin pain. The simulation had a sensitivity of 74%, specificity of 100%, and an AUC of 0.86. Conclusion. We developed a computational model that can quantify iliopsoas impingement and verified its accuracy in a case-controlled investigation. This tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis. Cite this article: Bone Jt Open 2023;4(1):3–12


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 6 - 6
8 Feb 2024
Ammori M Hancock S Talukdar P Munro C Johnston A
Full Access

The objectives of our study were to compare patient reported outcome measures between manual and robotic-assisted total hip arthroplasty. Between 1st May 2021 and 31st August 2022, 539 consecutive patients who underwent 564 primary total hip arthroplasties were identified from the local registry database. Data were prospectively collected, and included patient demographics, American Society of Anaesthesiologists (ASA) grade, surgical approach, robotic-assistance, Oxford Hip Score (OHS), EQ-5D-3L and EQ-VAS pre-operatively and at twelve months. Robotic-assistance, compared against manual total hip arthroplasty, was associated with an enhanced median (interquartile range) OHS (46 [42 – 48] vs 43 [36 – 47], p-value < 0.001), EQ-5D-3L (5 [5 – 7] vs 6 [5 – 8], p-value 0.002), and EQVAS (90 [75 – 95] vs 80 [70 – 90], p-value 0.003) at twelve months after surgery. Robotic-assistance was confirmed to be an independent predictor of a greater OHS at twelve months on a multivariate linear regression analysis (p-value 0.001). Robotic assistance was superior to manual total hip arthroplasty in enhancing patient reported outcomes at twelve months after surgery


Bone & Joint Open
Vol. 5, Issue 3 | Pages 174 - 183
6 Mar 2024
Omran K Waren D Schwarzkopf R

Aims. Total hip arthroplasty (THA) is a common procedure to address pain and enhance function in hip disorders such as osteoarthritis. Despite its success, postoperative patient recovery exhibits considerable heterogeneity. This study aimed to investigate whether patients follow distinct pain trajectories following THA and identify the patient characteristics linked to suboptimal trajectories. Methods. This retrospective cohort study analyzed THA patients at a large academic centre (NYU Langone Orthopedic Hospital, New York, USA) from January 2018 to January 2023, who completed the Patient-Reported Outcomes Measurement Information System (PROMIS) pain intensity questionnaires, collected preoperatively at one-, three-, six-, 12-, and 24-month follow-up times. Growth mixture modelling (GMM) was used to model the trajectories. Optimal model fit was determined by Bayesian information criterion (BIC), Vuong-Lo-Mendell-Rubin likelihood ratio test (VLMR-LRT), posterior probabilities, and entropy values. Association between trajectory groups and patient characteristics were measured by multinomial logistic regression using the three-step approach. Results. Among the 1,249 patients, a piecewise GMM model revealed three distinct pain trajectory groups: 56 patients (4.5%) in group 1; 1,144 patients (91.6%) in group 2; and 49 patients (3.9%) in group 3. Patients in group 2 experienced swift recovery post-THA and minimal preoperative pain. In contrast, groups 1 and 3 initiated with pronounced preoperative pain; however, only group 3 exhibited persistent long-term pain. Multinomial regression indicated African Americans were exceedingly likely to follow trajectory groups 1 (odds ratio (OR) 2.73) and 3 (OR 3.18). Additionally, odds of membership to group 3 increased by 12% for each BMI unit rise, by 19% for each added postoperative day, and by over four if discharged to rehabilitation services (OR 4.07). Conclusion. This study identified three distinct pain trajectories following THA, highlighting the role of individual patient factors in postoperative recovery. This emphasizes the importance of preoperatively addressing modifiable risk factors associated with suboptimal pain trajectories, particularly in at-risk patients. Cite this article: Bone Jt Open 2024;5(3):174–183


Bone & Joint Open
Vol. 5, Issue 11 | Pages 971 - 976
5 Nov 2024
Baker G Hill J O'Neill F McChesney J Stevenson M Beverland D

Aims. In 2015, we published the results of our ceramic-on-metal (CoM) total hip arthroplasties (THAs) performed between October 2007 and July 2009 with a mean follow-up of 34 months (23 to 45) and a revision rate of 3.1%. The aim of this paper is to present the longer-term outcomes. Methods. A total of 264 patients were reviewed at a mean of 5.8 years (4.6 to 7.2) and 10.1 years (9.2 to 10.6) to determine revision rate, pain, outcome scores, radiological analysis, and blood ion levels. Those who were unwilling or unable to travel were contacted by telephone. Results. The all-cause revision rate at six years was 3.1% (eight THAs), increasing to 8.8% (18 THAs) at ten years. Of these, there were four and then seven bearing-related revisions at six and ten years, respectively. There was a statistically significant deterioration in the visual analogue scale pain score and Oxford Hip Score (OHS) between six and ten years. There were 18 CoM THAs in 17 patients who had a cobalt or chromium level over 4 ppb and ten CoM THAs in nine patients who had a cobalt or chromium level higher than 7 ppb with a statistically significant increase in chromium levels only between the two timepoints. Overall, 84 stems (39.1%) had significant radiolucent lines at ten years compared to 65 (25.5%) at six years. Conclusion. When compared to the original review, there has been a significant deterioration in pain score, OHS, radiograph appearance, and, most critically, survival has fallen to 91.2%, which does not meet the Orthopaedic Data Evaluation Panel (ODEP) 10 A* 95% threshold. Although this bearing is no longer on the market, 2.5% were bearing-related revisions, which have relevance to the discussion around modular dual-mobility implants that have a similar metal interface


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 9 - 9
19 Aug 2024
Pulik Ł Łęgosz P Brzóska E Mierzejewski B Grabowska I Ciemerych MA Hube R
Full Access

This meta analysis address the relationship between infection developing after total hip arthroplasty (THA) and heterotopic ossification (HO). To identify the gaps in available knowledge, we screened for full-length peer-reviewed research articles listed in PubMed, Embase, and Web of Science over the past 20 years. The following search terms and Boolean operators were used: heterotopic ossification AND infection AND (hip replacement OR hip arthroplasty). The search resulted in the identification of as few as 14 articles describing periprosthetic joint infection (PJI) and HO after THA. Data summarized from 6 studies suitable for further meta-analysis yielded a cumulative sample size of 753 observations, with 186 recorded events of HO. The pooled RR was estimated at 2.22 (95% CI: 1.00 to 4.91, p = 0.0497), suggesting a more than twofold risk of HO compared to the group without PJI. In conclusion, there is a clear association between a higher risk of HO and PJI. Basic research findings support the hypothesis that bacterial pathogen-associated molecular patterns (PAMPs) can lead to osteogenesis through a toll-like receptor (TLR) and nuclear factor kappa B (NF-κB) pathway in the course of HO development. Together, these results suggest that HO prophylaxis should always be prescribed in PJI after THA. Moreover, during revisions following THA for presumed non-septic reasons, the presence of HO warrants consideration for infection, as there is a potential heightened risk of pathologic ossification induced by PAMPs. Keywords: heterotopic ossification; total hip arthroplasty; total hip replacement; periprosthetic joint infection; bacteria. Authors Ł. Pulik and P. Łęgosz contributed equally to this work


Bone & Joint Research
Vol. 13, Issue 4 | Pages 193 - 200
23 Apr 2024
Reynolds A Doyle R Boughton O Cobb J Muirhead-Allwood S Jeffers J

Aims. Manual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during total hip arthroplasty (THA). This study aims to quantify the accuracy and precision of manual impaction strikes during the seating of an acetabular component. This understanding aims to help improve impaction surgical techniques and inform the development of future technologies. Methods. Posterior approach THAs were carried out on three cadavers by an expert orthopaedic surgeon. An instrumented mallet and introducer were used to insert cementless acetabular cups. The motion of the mallet, relative to the introducer, was analyzed for a total of 110 strikes split into low-, medium-, and high-effort strikes. Three parameters were extracted from these data: strike vector, strike offset, and mallet face alignment. Results. The force vector of the mallet strike, relative to the introducer axis, was misaligned by an average of 18.1°, resulting in an average wasted strike energy of 6.1%. Furthermore, the mean strike offset was 19.8 mm from the centre of the introducer axis and the mallet face, relative to the introducer strike face, was misaligned by a mean angle of 15.2° from the introducer strike face. Conclusion. The direction of the impact vector in manual impaction lacks both accuracy and precision. There is an opportunity to improve this through more advanced impaction instruments or surgical training. Cite this article: Bone Joint Res 2024;13(4):193–200


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 110 - 114
1 Mar 2024
Yee AHF Chan VWK Fu H Chan P Chiu KY

Aims. The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in total hip arthroplasty (THA) at a minimum follow-up of 20 years. Methods. We reviewed the results of 165 THAs using the Omnifit HA system in 138 patients, performed between August 1993 and December 1999. The mean age of the patients at the time of surgery was 46 years (20 to 77). Avascular necrosis was the most common indication for THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (20 to 31). At 20 and 25 years, 113 THAs in 91 patients and 63 THAs in 55 patients were available for review, respectively, while others died or were lost to follow-up. Kaplan-Meier analysis was performed to evaluate the survival of the stem. Radiographs were reviewed regularly, and the stability of the stem was evaluated using the Engh classification. Results. A total of seven stems (4.2%) were revised during the study period: one for aseptic loosening, three for periprosthetic fracture, two for infection, and one for recurrent dislocation. At 20 years, survival with revision of the stem for any indication and for aseptic loosening as the endpoint was 96.0% (95% confidence interval (CI) 92.6 to 99.5) and 98.4% (95% CI 96.2 to 100), respectively. At 25 years, the corresponding rates of survival were 94.5% (95% CI 89.9 to 99.3) and 98.1% (95% CI 95.7 to 99.6), respectively. There was radiological evidence of stable bony fixation in 86 stems (76.1%) and evidence of loosening in four (3.5%) at 20 years. All patients with radiological evidence of loosening were asymptomatic. Conclusion. The Omnifit HA femoral stem offered promising long-term survival into the third decade. Cite this article: Bone Joint J 2024;106-B(3 Supple A):110–114


Bone & Joint Open
Vol. 3, Issue 12 | Pages 960 - 968
23 Dec 2022
Hardwick-Morris M Wigmore E Twiggs J Miles B Jones CW Yates PJ

Aims. Leg length discrepancy (LLD) is a common pre- and postoperative issue in total hip arthroplasty (THA) patients. The conventional technique for measuring LLD has historically been on a non-weightbearing anteroposterior pelvic radiograph; however, this does not capture many potential sources of LLD. The aim of this study was to determine if long-limb EOS radiology can provide a more reproducible and holistic measurement of LLD. Methods. In all, 93 patients who underwent a THA received a standardized preoperative EOS scan, anteroposterior (AP) radiograph, and clinical LLD assessment. Overall, 13 measurements were taken along both anatomical and functional axes and measured twice by an orthopaedic fellow and surgical planning engineer to calculate intraoperator reproducibility and correlations between measurements. Results. Strong correlations were observed for all EOS measurements (r. s. > 0.9). The strongest correlation with AP radiograph (inter-teardrop line) was observed for functional-ASIS-to-floor (functional) (r. s. = 0.57), much weaker than the correlations between EOS measurements. ASIS-to-ankle measurements exhibited a high correlation to other linear measurements and the highest ICC (r. s. = 0.97). Using anterior superior iliac spine (ASIS)-to-ankle, 33% of patients had an absolute LLD of greater than 10 mm, which was statistically different from the inter-teardrop LLD measurement (p < 0.005). Discussion. We found that the conventional measurement of LLD on AP pelvic radiograph does not correlate well with long leg measurements and may not provide a true appreciation of LLD. ASIS-to-ankle demonstrated improved detection of potential LLD than other EOS and radiograph measurements. Full length, functional imaging methods may become the new gold standard to measure LLD. Cite this article: Bone Jt Open 2022;3(12):960–968


Bone & Joint Open
Vol. 3, Issue 8 | Pages 611 - 617
1 Aug 2022
Frihagen F Comeau-Gauthier M Axelrod D Bzovsky S Poolman R Heels-Ansdell D Bhandari M Sprague S Schemitsch E

Aims. The aim of this study was to explore the functional results in a fitter subgroup of participants in the Hip Fracture Evaluation with Alternatives of Total Hip Arthroplasty versus Hemiarthroplasty (HEALTH) trial to determine whether there was an advantage of total hip arthroplasty (THA) versus hemiarthroplasty (HA) in this population. Methods. We performed a post hoc exploratory analysis of a fitter cohort of patients from the HEALTH trial. Participants were aged over 50 years and had sustained a low-energy displaced femoral neck fracture (FNF). The fittest participant cohort was defined as participants aged 70 years or younger, classified as American Society of Anesthesiologists grade I or II, independent walkers prior to fracture, and living at home prior to fracture. Multilevel models were used to estimate the effect of THA versus HA on functional outcomes. In addition, a sensitivity analysis of the definition of the fittest participant cohort was performed. Results. There were 143 patients included in the fittest cohort. Mean age was 66 years (SD 4.5) and 103 were female (72%). No clinically relevant differences were found between the treatment groups in the primary and sensitivity analyses. Conclusion. This analysis found no differences in functional outcomes between HA and THA within two years of displaced low-energy FNF in a subgroup analysis of the fittest HEALTH patients. These findings suggest that very few patients above 50 years of age benefit in a clinically meaningful way from a THA versus a HA early after injury. Cite this article: Bone Jt Open 2022;3(8):611–617


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 55 - 55
23 Jun 2023
Alqazzaz A Bush A Zhuang T Nelson CL
Full Access

Surgical management of acetabular fractures in older patients remains controversial. The purpose of this study is to compare outcomes of primary THA with outcomes after THA for acute acetabular fractures (aTHA) as well as outcomes following delayed THA (dTHA) following prior acetabular fracture.

We analyzed data from a large, national administrative claims database containing diagnostic, procedural, and demographic records from over 157 million patients. We identified all patients undergoing primary total hip arthroplasty THA continuously enrolled in the database at least 2 years prior and after the index procedure. Patients with an initial diagnostic code for acetabular fracture occurring the same day as the THA were classified as acute acetabular fractures. Patients with an initial acetabular fracture diagnostic code occurring at least 6 months before THA were classified as chronic acetabular fractures. The comparator group was patients undergoing THA with no history of acetabular fracture. There were 426,734 patients undergoing primary THA, 235 patients undergoing aTHA and 1,255 patients undergoing dTHA.

Patients with an aTHA had higher complication rates, including revisions (9.8% vs 5.6%,), dislocations (8.9% vs 6.4%), and periprosthetic fracture (5.1% vs 2.3%) compared to dTHA. After adjusting for age, sex, region, and comorbidities, receiving an aTHA increased the odds of revision (OR = 3.65 [95% CI: 2.30–5.49]), dislocation (OR = 4.09 [95% CI: 2.53–6.27]), and periprosthetic fracture (OR = 4.29 [95% CI: 2.26–7.36]) compared to primary THA. Receiving a dTHA significantly increased the odds of revision (adjusted OR = 1.80 [95% CI: 1.40–2.27]), dislocation (adjusted OR = 2.50 [95% CI: 1.97–3.13]), and periprosthetic fracture (adjusted OR = 1.99 [95% CI: 1.34–2.83]) compared to primary THA.

Patients undergoing aTHA in the treatment of an acetabular fracture have significantly increased rates of revision, periprosthetic fracture, and dislocation compared to dTHA and primary THA.


Bone & Joint Open
Vol. 5, Issue 8 | Pages 715 - 720
23 Aug 2024
Shen TS Cheng R Chiu Y McLawhorn AS Figgie MP Westrich GH

Aims. Implant waste during total hip arthroplasty (THA) represents a significant cost to the USA healthcare system. While studies have explored methods to improve THA cost-effectiveness, the literature comparing the proportions of implant waste by intraoperative technology used during THA is limited. The aims of this study were to: 1) examine whether the use of enabling technologies during THA results in a smaller proportion of wasted implants compared to navigation-guided and conventional manual THA; 2) determine the proportion of wasted implants by implant type; and 3) examine the effects of surgeon experience on rates of implant waste by technology used. Methods. We identified 104,420 implants either implanted or wasted during 18,329 primary THAs performed on 16,724 patients between January 2018 and June 2022 at our institution. THAs were separated by technology used: robotic-assisted (n = 4,171), imageless navigation (n = 6,887), and manual (n = 7,721). The primary outcome of interest was the rate of implant waste during primary THA. Results. Robotic-assisted THA resulted in a lower proportion (1.5%) of implant waste compared to navigation-guided THA (2.0%) and manual THA (1.9%) (all p < 0.001). Both navigated and manual THA were more likely to waste acetabular shells (odds ratio (OR) 4.5 vs 3.1) and polyethylene liners (OR 2.2 vs 2.0) compared to robotic-assisted THA after adjusting for demographic and perioperative factors, such as surgeon experience (p < 0.001). While implant waste decreased with increasing experience for procedures performed manually (p < 0.001) or with navigation (p < 0.001), waste rates for robotic-assisted THA did not differ based on surgical experience. Conclusion. Robotic-assisted THAs wasted a smaller proportion of acetabular shells and polyethylene liners than navigation-guided and manual THAs. Individual implant waste rates vary depending on the type of technology used intraoperatively. Future studies on implant waste during THA should examine reasons for non-implantation in order to better understand and develop methods for cost-saving. Cite this article: Bone Jt Open 2024;5(8):715–720


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 71 - 71
14 Nov 2024
Karjalainen L Ylitalo A Lähdesmäki M Reito A Repo J
Full Access

Introduction. Cephalomedullary nailing (CMN) is commonly used for unstable pertrochanteric fracture. CMN is relatively safe method although various complications can potentially occur needing revision surgery. Commonly used salvage procedures such as renailing, hemiarthroplasty, conservative treatment or total hip arthroplasty (THA) are viable alternatives. The aim was to investigate the rate of THA after CMN and evaluate the performance on conversion total hip arthroplasty (cTHA) after failure of CMN. Method. Collected data included patients from two orthopedic centers. Data consisted of all cTHAs after CMN between 2014-2020 and primary cementless THA operations between 2013-2023. Primary THA operations were treated as a control group where Oxford Hip Score (OHS) was the main compared variable. Result. From 2398 proximal femoral hip procedures 1667 CMN procedures were included. Altogether 46/1667 (2.8%) CMNs later received THA. Indications for THA after CMN failure were 13 (28.3%) cut-outs, nine (19.6%) cut-throughs, eight (17.4%) nail breakages, seven (15.2%) post traumatic arthrosis, seven (15.2%) nonunions, one (2.2%) malunion and one (2.2%) collum screw withdrawal. Mean (SD) time to complication after CMN operation is 5.9 (6.8) months. Mean (SD) time from nail procedure to THA was 10.4 (12.0) months. Total complication rate for cTHA after CMN was 17.4%. Reported complications were infection with seven (15.2%) cases and one (2.2%) nerve damage. Mean (SD) time to cTHA complication was 3.6 (6.1) months. One-sample T-test showed OHS to be significantly better (P<.001) for primary cementless THA compared to cTHA after one year. Conclusion. Altogether 2.8% of CMN were converted to THA. Nearly half (47.8%) of the cTHA procedures were due to CMN cut-out or cut-through. OHS was significantly better in primary cementless THA compared to cTHA. Prosthetic joint infection was the most frequent complication related to cTHA


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 95 - 95
19 Aug 2024
de Steiger R Wall C Truong A Lorimer M Stoney J Graves S
Full Access

Obesity is a known risk factor for developing osteoarthritis and is also associated with an increased risk of developing complications post total hip replacement (THR). This study investigated the association between obesity and the risk of undergoing THR in Australia. From July 2017 to June 2018 a National Health Survey was conducted by the Australian Bureau of Statistics to collect height and weight data on a representative sample of patients across urban and rural areas across the country. This study examined a cohort of patients undergoing primary THR utilising data from the Australian Orthopaedic Association National Joint Replacement Registry from the same time period. Obesity classes were determined according to WHO criteria. Body mass index (BMI) for patients undergoing THR were obtained and the distribution of THR patients by BMI category was compared to the general population, in age and sex sub-groups. Generalised linear models assuming a binomial distribution and a log link were used to generate relative risks. Data from underweight categories, and age categories 34 years and younger, were excluded from further analyses because of small numbers. Data from the health survey showed there were 35.6% of persons overweight and 31.3% obese. During the same period, 32,495 primary THR were performed for osteoarthritis in Australia on patients who had a BMI recorded. Of these patients 37.1% were overweight and 41.7% were obese. Compared to the general population, there was a higher incidence of Class I, II, and III obesity in patients undergoing THR in both sexes aged 35 to 74 years. Class III obese females and males aged 55–64 years were 2.9 and 1.7 times more likely to undergo HR, respectively (p<0.001). Class III obese females and males underwent THR on average 5.7 and 7.0 years younger than their normal weight counterparts, respectively. Obese Australians are at increased risk of undergoing THR, and at a younger age. A national approach to address the prevalence of obesity, and possible prevention strategies, is needed


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 103 - 103
11 Apr 2023
Domingues I Cunha R Domingues L Silva E Carvalho S Lavareda G Carvalho R
Full Access

Patients who are Jehovah's witnesses do not accept blood transfusions. Thus, total hip arthroplasty can be challenging in this group of patients due to the potential for blood loss. Multiple strategies have been developed in order to prevent blood loss. A 76-year-old female, Jehovah's witness medicated with a platelet antiaggregant, presented to the emergency department after a fall from standing height. Clinically, she had pain mobilizing the right lower limb and radiological examination revealed an acetabular fracture with femoral head protrusion and ipsilateral isquiopubic fracture. Skeletal traction was applied to the femur during three weeks and no weight bearing was maintained during the following weeks. Posteriorly, there was an evolution to hip osteoarthritis with necrosis of the femoral head. The patient was submitted to surgery six months after the initial trauma, for a total hip arthroplasty. The surgery was performed with hypotensive anaesthesia, careful surgical technique and meticulous haemostasis and there was no need for blood transfusion. Posteriorly, there was a positive clinical evolution with progressive improvement on function and deambulation. Total hip arthroplasty may be safely carried out with good clinical outcomes in Jehovah's witnesses, without the need for blood transfusion, if proper perioperative precautions are taken, as has already been shown in previous studies


Bone & Joint Open
Vol. 4, Issue 6 | Pages 416 - 423
2 Jun 2023
Tung WS Donnelley C Eslam Pour A Tommasini S Wiznia D

Aims. Computer-assisted 3D preoperative planning software has the potential to improve postoperative stability in total hip arthroplasty (THA). Commonly, preoperative protocols simulate two functional positions (standing and relaxed sitting) but do not consider other common positions that may increase postoperative impingement and possible dislocation. This study investigates the feasibility of simulating commonly encountered positions, and positions with an increased risk of impingement, to lower postoperative impingement risk in a CT-based 3D model. Methods. A robotic arm-assisted arthroplasty planning platform was used to investigate 11 patient positions. Data from 43 primary THAs were used for simulation. Sacral slope was retrieved from patient preoperative imaging, while angles of hip flexion/extension, hip external/internal rotation, and hip abduction/adduction for tested positions were derived from literature or estimated with a biomechanical model. The hip was placed in the described positions, and if impingement was detected by the software, inspection of the impingement type was performed. Results. In flexion, an overall impingement rate of 2.3% was detected for flexed-seated, squatting, forward-bending, and criss-cross-sitting positions, and 4.7% for the ankle-over-knee position. In extension, most hips (60.5%) were found to impinge at or prior to 50° of external rotation (pivoting). Many of these impingement events were due to a prominent ischium. The mean maximum external rotation prior to impingement was 45.9° (15° to 80°) and 57.9° (20° to 90°) prior to prosthetic impingement. No impingement was found in standing, sitting, crossing ankles, seiza, and downward dog. Conclusion. This study demonstrated that positions of daily living tested in a CT-based 3D model show high rates of impingement. Simulating additional positions through 3D modelling is a low-cost method of potentially improving outcomes without compromising patient safety. By incorporating CT-based 3D modelling of positions of daily living into routine preoperative protocols for THA, there is the potential to lower the risk of postoperative impingement events. Cite this article: Bone Jt Open 2023;4(6):416–423


Bone & Joint Open
Vol. 5, Issue 9 | Pages 742 - 748
10 Sep 2024
Kodumuri P Joshi P Malek I

Aims. This study aimed to assess the carbon footprint associated with total hip arthroplasty (THA) in a UK hospital setting, considering various components within the operating theatre. The primary objective was to identify actionable areas for reducing carbon emissions and promoting sustainable orthopaedic practices. Methods. Using a life-cycle assessment approach, we conducted a prospective study on ten cemented and ten hybrid THA cases, evaluating carbon emissions from anaesthetic room to recovery. Scope 1 and scope 2 emissions were considered, focusing on direct emissions and energy consumption. Data included detailed assessments of consumables, waste generation, and energy use during surgeries. Results. The carbon footprint of an uncemented THA was estimated at 100.02 kg CO2e, with a marginal increase to 104.89 kg CO2e for hybrid THA. Key contributors were consumables in the operating theatre (21%), waste generation (22%), and scope 2 emissions (38%). The study identified opportunities for reducing emissions, including instrument rationalization, transitioning to LED lighting, and improving waste-recycling practices. Conclusion. This study sheds light on the substantial carbon footprint associated with THA. Actionable strategies for reducing emissions were identified, emphasizing the need for sustainable practices in orthopaedic surgery. The findings prompt a critical discussion on the environmental impact of single-use versus reusable items in the operating theatre, challenging traditional norms to make more environmentally responsible choices. Cite this article: Bone Jt Open 2024;5(9):742–748


Bone & Joint Open
Vol. 5, Issue 4 | Pages 304 - 311
15 Apr 2024
Galloway R Monnington K Moss R Donaldson J Skinner J McCulloch R

Aims. Young adults undergoing total hip arthroplasty (THA) largely have different indications for surgery, preoperative function, and postoperative goals compared to a standard patient group. The aim of our study was to describe young adult THA preoperative function and quality of life, and to assess postoperative satisfaction and compare this with functional outcome measures. Methods. A retrospective cohort analysis of young adults (aged < 50 years) undergoing THA between May 2018 and May 2023 in a single tertiary centre was undertaken. Median follow-up was 31 months (12 to 61). Oxford Hip Score (OHS) and focus group-designed questionnaires were distributed. Searches identified 244 cases in 225 patients. Those aged aged under 30 years represented 22.7% of the cohort. Developmental dysplasia of the hip (50; 45.5%) and Perthes’ disease (15; 13.6%) were the commonest indications for THA. Results. Preoperatively, of 110 patients, 19 (17.2%) were unable to work before THA, 57 (52%) required opioid analgesia, 51 (46.4%) were reliant upon walking aids, and 70 (63.6%) had sexual activity limited by their pathology. One patient required revision due to instability. Mean OHS was 39 (9 to 48). There was a significant difference between the OHS of cases where THA met expectation, compared with the OHS when it did not (satisfied: 86 (78.2%), OHS: 41.2 (36.1%) vs non-satisfied: 24 (21%), OHS: 31.6; p ≤ 0.001). Only one of the 83 patients (75.5%) who returned to premorbid levels of activity did so after 12 months. Conclusion. Satisfaction rates of THA in young adults is high, albeit lower than commonly quoted figures. Young adults awaiting THA have poor function with high requirements for mobility aids, analgesia, and difficulties in working and undertaking leisure activities. The OHS provided a useful insight into patient function and was predictive of satisfaction rates, although it did not address the specific demands of young adults undertaking THA. Function at one year postoperatively is a good indication of overall outcomes. Cite this article: Bone Jt Open 2024;5(4):304–311


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 22 - 22
14 Nov 2024
Bulut H Tomey D
Full Access

Introduction. The concept of same-day discharge has garnered increasing significance within orthopedic surgery, particularly in hip and knee procedures. Despite initial concerns surrounding the absence of prolonged hospital care, a burgeoning body of evidence highlights numerous advantages associated with same-day discharge, ranging from mitigating in-hospital infections to offering substantial financial and psychosocial benefits for both patients and healthcare providers. In this study, we aim to scrutinize the trends in same-day discharge specifically within the realm of total hip arthroplasties. Method. This retrospective analysis delves into the American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) database spanning from 2017 to 2021. Leveraging patient data sourced from the ACS NSQIP database, we sought to elucidate patterns and shifts in same-day discharge practices pertaining to total hip arthroplasties. Result. The preoperative analysis illuminated several notable disparities between patients undergoing same-day hip arthroplasty and those necessitating hospitalization. Notably, same-day hip patients skewed younger, comprising 48.3%females compared to 55.6% in hospitalized hip patients. Furthermore, a lower prevalence of medical comorbidities such as diabetes mellitus (8.5% vs.12.9%), current smoking (9.3% vs. 12.2%), and severe COPD(1.9% vs. 4.1%) was observed among same-day hip group. Operatively, same-day hip surgeries boasted shorter durations, averaging 83.9 minutes, in contrast to the 92.3minutes for hospitalized hip procedures. Postoperatively, same-day hip patients exhibited significantly diminished rates of 30-day readmissions (1.7%vs. 3.5%), procedure-related readmissions (1.0%vs.2.1%), reoperations (1.1%vs.1.9%), and mortality (0.02% vs. 0.04%). Moreover, the prevalence of the same-day discharge concept experienced a remarkable ascent from 2016 to 2021, with rates escalating from 1.5% to 25.6% of all total hip arthroplasties over a span of just six years. Conclusion. In conclusion, same-day discharge is a feasible and safe option for selected THA patients


Bone & Joint Open
Vol. 5, Issue 10 | Pages 858 - 867
11 Oct 2024
Yamate S Hamai S Konishi T Nakao Y Kawahara S Hara D Motomura G Nakashima Y

Aims. The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy. Methods. We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and VAS pain by postal survey in August 2023 and explored variables associated with those scores. Results. Of the 58 patients (62 hips), two (two hips) presented with dislocation or reoperation, and Kaplan-Meier analysis indicated a five-year survival rate of 96.7% (95% CI 92.4 to 100). Mean stem anteversion was 35.2° (SD 18.2°) for the Taperloc stem and 29.8° (SD 7.9°) for the Wagner Cone stem; mean reduction from Taperloc to Wagner Cone was 5.4° (SD 18.8°). Overall, 55 hips (52 patients) were simulated, and the prevalence of prosthetic impingement was lower for the Wagner Cone (5.5%, 3/55) compared with the Taperloc (20.0%, 11/55) stem, with an odds ratio of 0.20 (p = 0.038). Among the 33 respondents to the postal survey (36 hips), the mean scores were VAS pain 10.9, VAS satisfaction 86.9, and OHS 44.7. A multivariable analysis revealed that reduction of stem anteversion from Taperloc to Wagner Cone was more favourable for VAS pain (p = 0.029) and VAS satisfaction (p = 0.002). Conclusion. The mid-term survival rate for THA using the Wagner Cone stem was high, which may be supported by a reduction in prosthetic impingement. The reduction in excessive stem anteversion by using a tapered cone stem was associated with reduced pain and increased patient satisfaction. Cite this article: Bone Jt Open 2024;5(10):858–867