Aims. Our primary aim was to establish the proportion of female orthopaedic consultants who perform arthroplasty via cases submitted to the National Joint Registry (NJR), which covers England, Wales, Northern Ireland, the Isle of Man, and Guernsey. Secondary aims included comparing time since specialist registration, private practice participation, and number of hospitals worked in between male and female surgeons. Methods. Publicly available data from the NJR was extracted on the types of arthroplasty performed by each surgeon, and the number of procedures of each type undertaken. Each surgeon was cross-referenced with the General Medical Council (GMC) website, using GMC number to extract surgeon demographic data. These included sex, region of practice, and dates of full and specialist registration. Results. Of 2,895 surgeons contributing to the NJR in 2023, 102 (4%) were female. The highest proportions of female surgeons were among those who performed elbow (n = 25; 5%), shoulder (n = 24; 4%), and ankle (n = 8; 4%) arthroplasty. Hip (n = 66; 3%) and knee arthroplasty (n = 39; 2%) had the lowest female representation. Female surgeons had been practising for a median of 10.4 years since specialist registration compared to 13.7 years for males (p < 0.001). Northern Ireland was the region with the highest proportion of female arthroplasty surgeons (8%). A greater proportion of male surgeons worked in private practice (63% vs 24%; p < 0.001) and in multiple hospitals (74% vs 40%; p < 0.001). Conclusion. Only 4% of surgeons currently contributing cases to the NJR are female, with the highest proportion performing
The aim of the New Zealand
Introduction: The design of the GSB III
Objective:. Total elbow joint arthroplasty has limited longevity and is therefore not appropriate for younger rheumatoid arthritis patients. Arthroplasty using an inter-positional membrane may be another surgical option for this population. However, clinical results for joint arthroplasty using the inter-positional membrane have not traditionally been favorable because rheumatoid activity could not be controlled. Today, rheumatoid activity can be controlled with biologics; therefore, the utility of the inter-positional membrane procedure was re-evaluated. Methods:. An 8×6 cm sheet of fascia was detached from the patient's tensor fascia lata muscle to produce a JK membrane. The fascia was stretched on a frame and kept in a 2% chromic acid potassium solution for 24 hours. Then, the fascia was exposed to direct sunlight in order to reduce the dichromic acid. The fascia was washed out in running water for 24 hours and was then stored in phenol with the addition of 70% alcohol.
We report 5 cases of linked shoulder and
Introduction. Cement pressurisation in the distal humerus is technically difficult due to the anatomy of the humeral intramedullary (IM) cavity. Conventional cement restrictors often migrate proximally or leak, reducing the effect of pressurisation during implantation. Theoretically with a better cement bone interdigitation, the longevity of the
A systematic review of the English language literature has suggested that the performance of linked and unlinked
This study assesses long term performance of the Souter-Strathclyde
Introduction: Distal humeral fractures represent a constant challenge to the most experienced surgeon. This is the first report of the use of an unlinked prosthesis for the treatment of distal humeral fractures in elderly persons. Materials and Methods: From July 2000 to June 2001, 9 iBP
Introduction: In the evaluation of the major joints, self assessment tools have become wide spread aiming at a more precise quantification of joint function. Different tools have been developed for the elbow joint. However, there are only few data on the relationship between subjective self-assessment of joint function and objective measures. We developed a comprehensive assessment set for the evaluation of subjective elbow function and objective clinical findings and investigate long-term results after implantation of GSB III
This study assesses the clinical performance of the Souter-Strathclyde
This study assesses the clinical performance of the Souter-Strathclyde
Aims: To evaluate the short to medium term outcome of the Souter-Strathclyde prosthesis when used as a primary
Aim: To evaluate the short to medium term outcome of the Souter-Strathclyde prosthesis when used as a primary
Purpose: The long-term experience of linked semicon-strained total elbow arthroplasty was investigated as a salvage procedure for patients with distal humerus non-union not amenable to internal fixation. Method: Ninety-two consecutive total elbow arthroplasties performed for the treatment of a distal humeral nonunion were reviewed at an average follow-up of 6.5 years (range, 0.5 to 20.3 years). There were twenty-two men and sixty-nine women with an average age of sixtyfive years (range, twenty-two to eighty-four years) at the time of
Cement pressurisation in the distal humerus is technically difficult due to the anatomy of the humeral intramedullary (IM) cavity. Conventional cement restrictors often migrate proximally, reducing the effect of pressurisation during arthroplasty. Theoretically with a better cement bone interdigitation, the longevity of the
We studied 12 patients (13 elbows) who underwent total elbow replacement (TER) using the Kudo Mk IV or V prosthesis between 1989 and 1997. There were eight females and four males (mean age: 61 years, range: 38–74 years). The diagnosis was Rheumatoid arthritis in 10 patients and osteoarthritis in two patients. In each patient the initial result was classified as either excellent or good. All these patients then reported the recurrence of severe pain at a mean of four years from the time of the primary operation. Radiographic examination demonstrated fracture of the humeral stem in 10 elbows and subluxation of the joint in three elbows. The fractured humeral components were exchanged for long stem components. The three subluxated elbows were found to have undergone delamination and loosening of the ulnar components which were revised. One of these required revision to a linked prosthesis due to bone loss. In each case metallosis was found involving principally the synovial tissues which were as far as possible excised. Each patient regained a similar range of movement to that following the primary arthroplasty but continues to experience episodes of pain requiring anti-inflammatory medication. This is in contrast to our patients requiring revision procedures for implant loosening or instability who have become pain free. We conclude that the development of metallosis complicating mechanical implant failure predisposes to persisting symptoms following revision arthroplasty and recommend that this should be undertaken sooner rather than later when mechanical failure is detected.
To measure any observed migration and rotation of humeral and ulnar components using radiostereometric analysis. From 2002–2004 in a prospective ongoing study, twelve elbows in patients treated with either a linked or unlinked Acclaim total elbow prosthesis were included in a radiostereometry study. Six tantalum markers were introduced into the humerus another three markers were located on a humeral component. Four markers were placed in to ulna and three markers located on the ulnar component. RSA radiographs were taken postoperatively, six, twelve and twenty-four months. The radiographs were digitised and analysed using UmRSA software. The relative movement of the humeral and ulnar implants with respect to the bone was measured. At twelve months, the largest segment translation of the humeral component was in the anterior/posterior direction with a mean of 0.44mm followed by medial/lateral translation of 0.39 mm; there was minimal proximal/ distal translation or with a mean of 0.16mm. Paired t-tests between twelve and 24 months segment translation data showed the mean differences to be no more than 0.056mm. The largest rotation at twelve months was anteversion/retroversion with a mean of 2.40deg, anterior tilt had a mean of 1.20deg and varus/valgus tilt was minimal mean 0.60deg. Mean difference between twelve and 24 months segment rotation was no more than 0.30deg. In contrast, humeral tip motion produced a mean of 1.1mm at 12 months dominated by movement in the plane horizontal plane with a mean difference at 24 months of 0.06mm. No patients could be measured for segment micromotion of the ulnar component due to technical difficulty in visualising tantalum markers in the ulna. Early micromotion of the Acclaim humeral implant occurs mostly by rotation about the vertical axis accompanied by anterior tilt. This motion reaches a plateau at 12 months after operation.