Introduction. Orthopaedic rehabilitation of adolescences and young adults with high dislocation of the femur is rather challenging. The role of palliative salvage procedures is controversial enough in the cohort of patients. Materials and Methods. Treatment outcomes of 10 patients with congenital hip dislocation were analyzed. Mean age at intervention was 17,8 years (15–22). The grade of dislocation were assessed according to Eftekhar: type C − 2, type D − 8. The mean baseline shortening was 4.7±0.36 cm. All subjects underwent PSO with the Ilizarov method. Another osteotomy for lengthening and realignment was produced at the boundary of the upper and middle third of the femur. The mean time in the Ilizarov frame was 5.3 months. Results. The mean follow-up was 2.6±.1 years (range, 15 to 32 years). Limb shortening of 1 cm to 1. 1. /. 2. cm was observed in four cases. Functional outcomes according to d'Aubigne-Postel were: Pain 4,4±0,15 points. ROM − 4,1±0,3 points. Walking ability − 4,5±0,2 points. Two cases had good results (15–17 points), and seven patients had fair outcomes (12–14 points). A poor result (7 points) was recorded in one female patient 28 years after PSO followed by THA. Conclusions.
Purpose. The aim of this study was to identify if perioperative outcomes were different in patients with cerebral palsy undergoing unilateral or bilateral
Introduction: The purpose of this study was to evaluate the predictors of outcome of
Introduction. Dislocation is one of the most important complications after primary total hip replacement (THR). The low incidence of this finding makes it difficult to analyse the possible risk factors. The surgical technique can also influence this rate through cup position or an adequate
Introduction: The purpose of this study was to evaluate the predictors of outcome of
In cemented total hip arthroplasty, the cement-bone interface can be considerably degraded in less than one year in-vivo service (Figure 1). This makes the interface much weaker relative to the direct post-operative situation. Retrieval studies show that patients do, to a certain extent, not suffer from the degraded cement-bone interface itself. It is, however, unknown whether the degraded cement-bone interface affects other failure mechanisms in the cemented
Background. Ilizarov
Purpose of study: To assess functional, clinical and radiological outcomes of 30 children (60 hips) with whole body cerebral palsy with a mean follow-up of ten years. Method: Bilateral simultaneous combined soft-tissue and bony hip surgery was performed at a mean age of 7.7 years (3.1–12.2). Evaluation at ten years involved interviews with patient/carers and clinical examination. Plane radiographs of the pelvis assessed migration percentage and centre-edge angle. Results: Twenty two patients were recalled. Five had died of unrelated causes and three were lost to follow-up. Pain was present in only 1 patient (4.5%). Improved handling was reported in 18 of 22 patients (82%). Carer handling problems were attributed to growth of the patients. All patients/carers considered the procedure worthwhile. The range of hip movements improved, with a mean windsweep index of 36 (50 pre-operatively) Radiological containment improved, with mean migration percentage of 20 degrees (50 preoperatively) and mean centre-edge angle of 29 degrees (−5 preoperatively) No statistical difference was noted between the three year and ten year follow-up results, demonstrating sustained improvement in the clinical and radiological outcome. Conclusions: Bilateral simultaneous combined
The results of a functional, clinical and radiological study of 30 children (60 hips) with whole body cerebral palsy are presented with a mean follow-up of ten years. Bilateral simultaneous combined soft-tissue and bony surgery was performed at a mean age of 7.7 years (3.1–12.2). Evaluation involved interviews with patient/carers and clinical examination. Plain radiographs of the pelvis assessed migration percentage and centre-edge angle. Twenty two patients were recalled. Five had died of unrelated causes and three were lost to follow-up. Pain was uncommon, present in 1 patient (4.5%). Improved handling was reported in 18 of 22 patients (82%). Carer handling problems were attributed to growth of the patients. All patients/carers considered the procedure worthwhile. The range of hip movements improved, with a mean windsweep index of 36 (50 pre-operatively). Radiological containment improved, with mean migration percentage of 20 degrees (50 preoperatively) and mean centre-edge angle of 29 degrees (−5 preoperatively) No statistical difference was noted between the three year and ten year follow-up results demonstrating maintained clinical and radiological outcome improvement. In conclusion, we consider that bilateral simultaneous combined
Purpose: Clinical studies still show significant variability in offset and leg length reconstruction after 28mmTHA. Precise restoration of hip biomechanics is important since it reduces wear and improves stability, abductor function and patient satisfaction. There is a tendency to increase offset and leg length to ensure stability of 28mmTHA. This may not be needed with the more stable LDHTHA and hip resurfacing implants, therefore potentially improving the precision of the
Custom acetabular components have become an established method of treating massive acetabular bone defects in hip arthroplasty. Complication rates, however, remain high and migration of the cup is still reported. Ischial screw fixation (IF) has been demonstrated to improve mechanical stability for non-custom, revision arthroplasty cup fixation. We hypothesise that ischial fixation through the flange of a custom acetabular component aids in anti-rotational stability and prevention of cup migration. Electronic patient records were used to identify a consecutive series of 49 custom implants in 46 patients from 2016 to 2022 in a unit specializing in complex joint reconstruction. IF was defined as a minimum of one screw inserted into the ischium passing through a hole in a flange on the custom cup. The mean follow-up time was 30 months. IF was used in 36 cups. There was no IF in 13 cups. No difference was found between groups in age (68.9 vs. 66.3, P = 0.48), BMI (32.3 vs. 28.2, P = 0.11) or number of consecutively implanted cups (3.2 vs. 3.6, P = 0.43). Aseptic loosening with massive bone loss was the primary indication for revision. There existed no difference in Paprosky grade between the groups (P = 0.1). 14.2% of hips underwent revision and 22.4% had at least one dislocation event. No ischial fixation was associated with a higher risk of cup migration (6/13 vs. 2/36, X2 = 11.5, P = 0.0007). Cup migration was associated with an increased risk for all cause revision (4/8 vs. 3/38, X2 = 9.96, P = 0.0016, but not with dislocation (3/8 vs. 8/41, X2 = 1.2, P = 0.26). The results suggest that failure to achieve adequate ischial fixation, with screws passing through the flange of the custom component into the ischium, increases the risk of cup migration, which, in turn, is a risk factor for revision.
Osteolysis, fractures, and bone destruction caused by osteomyelitis or metastasis can cause large bone defects and present major challenges during acetabular reconstruction in total hip arthroplasty. We sought to evaluate the survivorship and radiographic outcomes of an acetabular reconstruction consisting of a polyethylene liner (semi-constrained) embedded in cement filling bone defect(s) reinforced with screws and/or plates for enhanced fixation (HiRISC). Retrospective chart review of 59 consecutive acetabular reconstructions as described above performed by 4 surgeons in a single institution (10/18/2018-1/5/2023) was performed. After radiographs and operative reports were reviewed, cases were classified following the Paprosky classification for acetabular defects. Paprosky type 1 cases (n=26) were excluded, while types 2/3 (n=33) were included for analysis. Radiographic loosening was evaluated up to latest follow-up. Mean follow-up was: 487 days (range, 20–1,539 days). Out of 33 cases, 2 (6.1%) cases were oncological (metastatic disease) and 22 (66.7%) had deep infection diagnosis (i.e., periprosthetic joint infection [PJI] or septic arthritis). In total, 7 (21.2%) reconstructions were performed on native acetabula (3 septic, 4 aseptic). At a mean follow-up of 1.3 years, 5 (15.2%) constructs were revised: 4 due to uncontrolled infection (spacer exchange) and 1 for instability. On follow-up radiographs, only 1 non-revised construct showed increased radiolucencies, but no obvious loosening. When compared to patients with non-revised constructs, those who underwent revision (n=5) were significantly younger (mean 73.8 vs. 60.6 years, p=0.040) and had higher body mass index (24.1 vs. 31.0 Kg/m2, p=0.045), respectively. Sex, race, ethnicity, American-Society-of-Anesthesiologist classification, infection diagnosis status (septic/aseptic), and mean follow-up (449.3 vs. 695.6 days, respectively, p=0.189) were not significantly different between both groups. HiRISC construct may be a viable short-term alternative to more expensive implants to treat large acetabular defects, particularly in the setting of PJI. Longer follow up is needed to establish long term survivorship.
Metal-on-polycarbonate urethane (MPU) is a cutting-edge new bearing technology for hip arthroplasty. The acetabular component consists of a 2.7mm-thick polycarbonate-urethane liner inserted into a specially manufactured uncemented titanium shell coated with hydroxyapatite [(HA) Fig. 1]. The liner is pliable and biomechanically mimics human cartilage. In vitro studies have shown minimal wear, fluid film lubrication, physiological load transmission and shock absorption capacity equal to the normal hip. This system includes prosthetic heads of a diameter 12mm less than the socket diameter. The aim of this study was to clinically assess patients treated with this novel technology in a retrospective single centre study. Twenty-seven patients with osteoarthritis treated with MPU bearing arthroplasty were included. Mean patient age was 67.9±10.35 years (44–84). Sixteen patients were female and 11 were male. Twenty-four of these had an uncemented HA-coated stem while 3 had a hip resurfacing metal femoral component. All patients were operated on by a single surgeon using a postero-lateral approach.Introduction
Methods
The childhood hip conditions of Developmental Dysplasia, Legg-Calve-Perthes Disease and Slipped Capital Femoral Epiphysis have a wide spectrum of anatomical outcomes following childhood treatment; ranging from morphologies, which result in normal hip function throughout life, to severely deranged morphologies, which result in pain and disability during childhood and adolescence. Some of these outcomes are as a result of well-intentioned interventions that result in catastrophic complications. In 2003, after years of working with impingement complicating periacetabular osteotomies and building on the work of William Harris, Reinhold Ganz published his concepts of ‘cam’ and ‘pincer’ hip impingement, and how these anatomical morphologies resulted in hip arthritis in adulthood. These concepts of impingement were added to his previous published work on hip instability to provide a comprehensive theory describing how hip arthritis develops on the basis of anatomical abnormalities. Surgical techniques have been developed to address each of these morphological pathologies. Ganz's concepts of hip impingement and instability may be applied to severe paediatric hip deformities to direct reconstructive joint preserving surgery to both the femur and the acetabulum. Ganz's surgical approaches have also been refined for use in paediatric hip surgery to allow radical reshaping salvage osteotomies to be performed on the developing femoral head with minimal risk of the devastating consequence of vascular Necrosis.
Prospective study on a case serie of 113 THA’s performed by two surgeons in a single institution.
Complications included 1 superficial infection, 2 dislocations. No vasculo-nervous complication; and in 2 cases technical difficulties to achieve good fixation due to ethiology of the THA (desarthrodesis). The average Harris hip score improved from 48 to 89 following primary surgery.
The two-piece acetabular shell and augments permits the reconstruction of every acetabular bone defect.
Instability accounts for one third of revision total hip arthroplasty(rTHA) performed in the United Kingdom. Removal of well-fixed femoral stems in rTHA is challenging with a risk of blood loss and iatrogenic damage to the femur. The Bioball Universal Adaptor (BUA) (Merete, Germany), a modular head neck extension adaptor, provides a mechanism for optimisation of femoral offset, leg length and femoral anteversion. This can avoid the need for femoral stem revision in selected cases. There is a relative paucity of clinical data available with the use of this device. The aim of this study is to present the clinical results and rate of instability following revision with this head neck adaptor at a minimum of two years' follow up.Introduction
Aim
The Pelvic Support Osteotomy (PSO) or Ilizarov Hip Reconstruction(IHR) is well described for the treatment of septic sequelae of infancy. The purpose of this study was to clinically, functionally and radiographically assess our short-term results of this procedure. 25 patients (16 boys, 9 girls) who had undergone an IHR using the Ilizarov/TSF construct over a period of 10 years for a variety of pathologies were reviewed.Aim
Method
The Pelvic Support Osteotomy (PSO) or Ilizarov Hip Reconstruction(IHR) is well described for the treatment of septic sequelae of infancy. The purpose of this study was to clinically, functionally and radiographically assess our short-term results of this procedure. 25 patients (16 boys, 9 girls) who had undergone a IHR using the Ilizarov/TSF construct over a period of 10 years for a variety of pathologies were reviewed. The mean age at surgery was 15 years 4 months. The pre-operative diagnoses were SCFE(10), hip sepsis (6), DDH (6) and Perthes (3). All had significant leg length discrepancies, 16 had a painful stiff hip, 6 had a painful mobile hip and 3 had a painless unstable hip. At surgery, a mean measured proximal valgus angle of 51° and a mean extension angle of 15° was achieved. Distal femoral lengthening averaged 4.2 cm and distal varus correction was a mean of 8°. The mean fixator time was 173 days. At a mean of 2 years and 7 months follow-up the lower-extremity length discrepancy had improved from a mean of 5.6 cm apparent shortening to 2.3 cm. Trendelenberg sign was eliminated in 18/25 cases. Improvements in range of hip movements and gait parameters were observed. Stance time asymmetry, step length asymmetry, pelvic dip and trunk lurch improved significantly. One patient had conversion to a total hip replacement after 7 years, 4 patients required re-do PSO due to remodelling of the proximal osteotomies, two had heterotopic ossification and two had significant knee stiffness due to lack of compliance. The early results of IHR are encouraging to equalise limb lengths, negate trendelenburg gait, provide a mobile hip with a reasonable axis and the possibility of conversion to THR in the future if needed. Complications need to be anticipated and the effects of remodelling and maintaining adequate knee range of motion must be emphasised.
A retrospective single-center review has been performed to gather clinical data on the use of polycarbonate-urethane (PCU) as an articulating bearing material inside a cobalt-chrome (Co-Cr) press-fit acetabular shell. As of January 2010, the Co-Cr shell and PCU liner have been implanted into 25 total hip patients which were retrospectively followed. The indications for use were in 24 cases of osteoarthritis, and 1 revision case. No patient was lost to follow-up. The average follow-up time was 17.6 months (range 8-27). The average age of these patients was 67.9 (range 44-84), the sex distribution was 14 female and 11 male patients, of whom 15 were right and 10 left side. 24 patients received a total hip replacement with the metal acetabular system and a cementless femoral stem and 1 patient received the metal acetabular shell coupled to a cemented resurfacing head. None of the cases has had a dislocation, revision, dislodgement, or infection. At follow-up, the mean Harris hip score was 98 points (80-99). X-rays showed good bone-implant contact without any osteolysis or bone rarefaction. A detailed review of the clinical data of these patients shows that a PCU liner inserted into a Co-Cr acetabular shell is as safe and effective as other commonly used acetabular shells in other total hip systems currently available. No new or unintended adverse or device-related events were discovered with the clinical use of PCU in a Co-Cr acetabular shell.
We investigated the feasibility of using porous titanium particles (TiP) to reconstruct femoral bone defects in revision hip replacement surgery in stead of using morzelised bone grafts. Questions regarding handling, initial stability and titanium particle release were addressed. Seven composite femurs (Sawbones) were reamed and filled, stepwise, with 32 grams of large (Ø 3.15 – 4 mm) and 9 grams of smaller (Ø 2.8 – 3.15 mm) pure, 85% porous TiP. Subsequently an Exeter stem was cemented into the graft layer. All reconstructions were loaded axially (0–3000 N) for 300,000 loading cycles at 2 Hz. Subsidence of the stem was measured with radio stereometric analysis (RSA) and possible titanium particle release was measured using the laser diffraction technique. The TiP were impacted into a >
3 mm (SD 1.43 mm) thick, highly entangled, graft layer. An average cement mantle of >
2 mm (SD 0.86 mm) was measured and little cement penetration was observed. The average subsidence of only 0.45 mm (SD 0.04 mm) was measured after 300 000 loading cycles. Most titanium particles were found directly after impaction. Most of these particles (87%) were smaller than 10 μm and could therefore be potentially harmful since they can induce osteolysis. We can conclude that:
A graft layer of impacted TiP can be constructed, The graft layer is stable enough to initially support a cemented Exeter stem, Titanium particles are released during impaction. These data warrant further animal tests to assess the biological response to these released impaction particles. Also, animal tests should clarify possible particle release upon loading and its effects.