Advertisement for orthosearch.org.uk
Results 1 - 20 of 113
Results per page:
Bone & Joint Open
Vol. 5, Issue 10 | Pages 929 - 936
22 Oct 2024
Gutierrez-Naranjo JM Salazar LM Kanawade VA Abdel Fatah EE Mahfouz M Brady NW Dutta AK

Aims

This study aims to describe a new method that may be used as a supplement to evaluate humeral rotational alignment during intramedullary nail (IMN) insertion using the profile of the perpendicular peak of the greater tuberosity and its relation to the transepicondylar axis. We called this angle the greater tuberosity version angle (GTVA).

Methods

This study analyzed 506 cadaveric humeri of adult patients. All humeri were CT scanned using 0.625 × 0.625 × 0.625 mm cubic voxels. The images acquired were used to generate 3D surface models of the humerus. Next, 3D landmarks were automatically calculated on each 3D bone using custom-written C++ software. The anatomical landmarks analyzed were the transepicondylar axis, the humerus anatomical axis, and the peak of the perpendicular axis of the greater tuberosity. Lastly, the angle between the transepicondylar axis and the greater tuberosity axis was calculated and defined as the GTVA.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 9 - 19
16 Jan 2024
Dijkstra H van de Kuit A de Groot TM Canta O Groot OQ Oosterhoff JH Doornberg JN

Aims

Machine-learning (ML) prediction models in orthopaedic trauma hold great promise in assisting clinicians in various tasks, such as personalized risk stratification. However, an overview of current applications and critical appraisal to peer-reviewed guidelines is lacking. The objectives of this study are to 1) provide an overview of current ML prediction models in orthopaedic trauma; 2) evaluate the completeness of reporting following the Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) statement; and 3) assess the risk of bias following the Prediction model Risk Of Bias Assessment Tool (PROBAST) tool.

Methods

A systematic search screening 3,252 studies identified 45 ML-based prediction models in orthopaedic trauma up to January 2023. The TRIPOD statement assessed transparent reporting and the PROBAST tool the risk of bias.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 111 - 111
23 Feb 2023
Stevens J Eldridge J Tortonese D Whitehouse M Krishnan H Elsiwy Y Clark D
Full Access

In the unstable patellofemoral joint (PFJ), the patella will articulate in an abnormal manner, producing an uneven distribution of forces. It is hypothesised that incongruency of the PFJ, even without clinical instability, may lead to degenerative changes. The aim of this study was to record the change in joint contact area of the PFJ after stabilisation surgery using an established and validated MRI mapping technique. A prospective MRI imaging study of patients with a history of PFJ instability was performed. The patellofemoral joints were imaged with the use of an MRI scan during active movement from 0° through to 40° of flexion. The congruency through measurement of the contact surface area was mapped in 5-mm intervals on axial slices. Post-stabilisation surgery contact area was compared to the pre-surgery contact area. In all, 26 patients were studied. The cohort included 12 male and 14 female patients with a mean age of 26 (15–43). The greatest mean differences in congruency between pre- and post-stabilised PFJs were observed at 0–10 degrees of flexion (0.54 cm. 2. versus 1.18 cm. 2. , p = 0.04) and between 11° and 20° flexion (1.80 cm. 2. versus 3.45 cm. 2. ; p = 0.01). PFJ stabilisation procedures increase joint congruency. If a single axial series is to be obtained on MRI scan to compare the pre- and post-surgery joint congruity, the authors recommend 11° to 20° of tibiofemoral flexion as this was shown to have the greatest difference in contact surface area between pre- and post-operative congruency


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 45 - 45
22 Nov 2024
Stoddart C Hennessy C Ashworth J Vaz J Alvand A Kendrick B Palmer A Partington K
Full Access

Aim. Prosthetic joint infection (PJI) is assessed using clinical history and examination, imaging studies and laboratory investigations which inform diagnostic tools such as that proposed by the European Bone and Joint Infection Society to determine the probability of infection. Infection is often confirmed by microbiology culture and histology from intraoperative samples, but ideally a diagnosis of infection is made preoperatively to guide management decisions. At our institution, a tertiary referral centre for PJI, ultrasound (US)-guided synovial biopsy is routinely used as an adjunct to preoperative joint aspiration. Our aim was to evaluate the sensitivity and specificity of microbiology and histology results from US-guided synovial biopsy samples when compared to intraoperative samples. Method. In this retrospective study we analysed all prosthetic hip and knee US-guided biopsies performed at our institution over a 5 year period between 2018 and 2022. Microbiology and histology results from preoperative biopsy samples were individually compared to microbiology and histology findings from intraoperative samples. Results. 381 biopsies were performed; 281 knee, 100 hip. US-guided biopsy results showed strong positive predictive values (PPVs) in hip biopsies (microbiology PPV (79.3%), histology PPV (85.7%)) and knee biopsies (microbiology PPV (77%), histology PPV (85%)). Biopsies showed low sensitivity in predicting intraoperative findings (hip microbiology sensitivity (62%), hip histology sensitivity (31%), knee microbiology sensitivity (70%), knee histology sensitivity (21%). Biopsies showed high specificity for knee (microbiology specificity (89%), histology specificity (97%)) and hip (microbiology specificity (73%), histology specificity (91%)). Conclusions. This study demonstrates that US-guided biopsy is a valuable diagnostic aid for PJI with high specificities and PPVs. Furthermore US-biopsy is valuable when there is limited fluid for aspiration


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 10 - 10
23 Jul 2024
Al-hasani F Mhadi M
Full Access

Meniscal tears commonly co-occur with ACL tears, and many studies address their side, pattern, and distribution. Few studies assess the patient's short-term functional outcome concerning tear radial and circumferential distribution based on the Cooper et al. classification. Meniscal tears require primary adequate treatment to restore knee function. Our hypothesis is to preserve the meniscal rim as much as possible to maintain the load-bearing capacity of the menisci after meniscectomy. The purpose of this study is to document the location and type of meniscal tears that accompany anterior cruciate ligament (ACL) tears and their effect on patient functional outcomes following arthroscopic ACL reconstruction and meniscectomy. This prospective cross-sectional observational study was conducted at AL-BASRA Teaching Hospital in Iraq between July 2018 and January 2020 among patients with combined ipsilateral ACL injury and meniscal tears. A total of 28 active young male patients, aged 18 to 42 years, were included. All patients were subjected to our questionnaire, full history, systemic and regional examination, laboratory investigations, imaging studies, preoperative rehabilitation, and were followed by Lysholm score 6 months postoperatively. All 28 patients were males, with a mean age of 27 ± 0.14 years. The right knee was the most commonly affected in 20/28 patients (71.4%). The medial meniscus was most commonly injured in 11 patients, 7 patients had lateral meniscal tears, and 10 patients had tears in both menisci. The most common tear pattern of the medial meniscus was a bucket handle tear (36.4%), while longitudinal tears were the most frequent in the lateral meniscus (71.4%) (P-value = 0.04). The most common radial tear location was zone E-F (5/28, 17.8%), and the most common circumferential zone affected was the middle and inner third, reported in 50% of tears. Good and excellent outcomes using the Lysholm score after 6 months were obtained in 42.9% and 17.9% of patients, respectively. Better functional scores were associated with lateral meniscal tears, bucket handle tears, tears extending to a more peripheral vascular area, and if no more than one-third of the meniscus was resected (P-value = 0.002). Less favourable outcomes were reported in smokers, posterior horn tears, and when surgery was delayed more than 1 year (P-value = 0.03). We conclude that there is a negative correlation between the amount of meniscus resected and functional outcome. Delayed ACL reconstruction increases the risk of bimeniscal tears. Bucket handle tears are the most common tears, mostly in the medial meniscus, while longitudinal tears are most common in the lateral meniscus. We recommend performing early ACL reconstruction within 12 months to reduce the risk of bimeniscal injuries


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 44 - 44
17 Nov 2023
Radukic B Phillips A
Full Access

Abstract. 1.0 Objectives. Predictive structural models resulting in a trabecular bone topology closely resembling real bone would be a step toward 3D printing of sympathetic prosthetics. This study modifies an established trabecular bone structural adaptation approach, with the objective of achieving an improved adapted topology, specifically connectivity, compared to CT imaging studies; whilst retaining continuum level mechanical properties consistent with those reported in experimental studies. Strain driven structural adaptation models successfully identify trabecular trajectories, although tend to overpredict connectivity and skew trabecular radii distribution towards the smallest radius included in the adaptation. Radius adaptation of each trabecula is driven by a mechanostat approach with a target strain (1250 µɛ) below which radius is decreased (resorption), and above which radius is increased (apposition). Simulations include a lazy zone, in which neither resorption nor apposition takes place (1000 to 1500 µɛ); and a dead zone (<250 µɛ) in which complete resorption of trabeculae with the smallest included radius takes place. This study assesses the impact of increasing the dead zone threshold from <250 µɛ to <1000 µɛ, the lower limit of the lazy zone. 2.0 Methods. In-silico structural models with an initial connectivity (number of trabeculae connecting at each joint) of 14 were generated using a nearest neighbour approach applied to a random cloud of points. Trabeculae were modelled using circular beams whose radii were adapted in response to normal strains caused by the axial force and bending moments due to a vertical pressure of 1 MPa applied to the top of the lattice, with the bottom of the lattice fixed in the vertical direction. Lattices in which nodes are either able (rigid jointed) or unable (pin jointed) to transmit bending moments were considered. Five virtual samples of each lattice type were used, and each simulation repeated twice: with a dead zone of either <250 µɛ or <1000 µɛ. 3.0 Results. In pin jointed lattices the increase in dead zone threshold resulted in reduction of predicted Young's Modulus from 580 MPa (95% CI [577 MPa, 583 MPa]) to 408 MPa (95% CI [397 MPa, 419 MPa]) whilst in rigid jointed lattices it increased form 839MPa (95% CI [832 MPa, 846 MPa]) to 933 MPa (95% CI [931 MPa, 936 MPa]). Mean connectivity decreased from 10.2 to 5.8 in pin jointed simulations and from 9.6 to 3.8 in fixed joined simulations. Topological studies of trabecular bone CT images report a mean connectivity of around 3.4. Pin jointed lattice mean radius increased from 33mm to 45mm, and rigid jointed lattice mean radius increased from 33mm to 64mm. Prevalence of smallest included radius beams decreased in both. 4.0 Conclusion. Improved in-silico representations of trabecular bone can be achieved in structural adaptions by increasing the dead zone threshold and adopting a bending dominated (rigid jointed) lattice structure. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 116 - 116
1 Mar 2021
van Groningen B van der Steen MC Janssen DM van Rhijn LW van der Linden T Janssen RPA
Full Access

The purpose of this investigation was to evaluate systematically the literature concerning biopsy, MRI signal to noise quotient (SNQ) and clinical outcomes in graft-maturity assessment after autograft anterior cruciate ligament reconstruction (ACLR) and their possible relationships. Methods: The systematic review was reported and conducted according to the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) guidelines. Studies through May 2019 evaluating methods of intra-articular ACL autograft maturity assessment were considered for inclusion. Eligible methods were histologic studies of biopsy specimens and conventional MRI studies reporting serial SNQ and/ or correlation with clinical parameters. Ten biopsy studies and 13 imaging studies, with a total of 706 patients, met the inclusion criteria. Biopsy studies show that graft remodeling undergoes an early healing phase, a phase of remodeling or proliferation and a ligamentization phase as an ongoing process even 1 year after surgery. Imaging studies showed an initial increase in SNQ, peaking at approximately 6 months, followed by a gradual decrease over time. There is no evident correlation between graft SNQ and knee stability outcome scores at the short- and long-term follow-up after ACLR. The remodeling of the graft is an ongoing process even 1 year after ACLR, based on human biopsy studies. MRI SNQ peaked at approximately 6 months, followed by a gradual decrease over time. Heterogeneity of the MRI methods and technical restrictions used in the current literature limit prediction of graft maturity and clinical and functional outcome measures by means of MRI graft SNQ after ACLR


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 13 - 13
1 May 2021
Elsheikh A Hassan M Sharaf I
Full Access

Introduction. Diagnosis of chronic osteomyelitis (COM) is based mainly on the correlation between history, clinical picture, lab analysis, bacteriological, pathological, and imaging studies. Bone biopsy for culture and sensitivity is the gold standard for the correct identification of the causative organism. The present prospective study aims to evaluate the accuracy of FDG PET-CT in the diagnosis of COM in comparison to the bacteriological, pathological findings. Materials and Methods. 18 patients (16 males/two females) underwent FDG-PET/CT scanning for clinically or radiologically suspected COM of the lower extremity. Fourteen patients had septic non-union, three patients with aseptic non-union, and one with chronic diffuse sclerosing OM of Garre. Seven patients had implants at site of examination at the time of the scan. Diagnosis of COM was confirmed by deep surgical cultures and pathological analysis (index debridement done by s single surgeon in one centre) following PET/CT scanning. FDG-PET uptake was measured by SUV max (the highest uptake of the radioisotope in the infection area). These findings were correlated to the microbiological and histopathological results. Results. Infection was clinically evident at a mean of 15 weeks (range, 2 to 60 weeks) after the date of injury. Patients had a mean of 2.3 (range 0 – 7) operations, before index debridement. The mean SUV max on the affected side was (9.55 ± 5.22), While mean SUV max on the contralateral healthy side was (1.82 ± 0.98). The pattern of FDG-uptake was diffuse in nine (50%), localised in seven (38.9%), and intramedullary in two (11.1%) patients respectively. The sensitivity, specificity, accuracy, PPV and NPV of PET SUV max were 100%, 66.7%, 94.44%, 93.75% and 100% respectively in the diagnosis of COM at a cut-off value of (4.46). The present study included 15 true positive, two true negative and one false-positive PET/CT results. Conclusions. 18F-FDG PET/CT is a highly sensitive and specific method for the evaluation of chronic osteomyelitis in patients with or without trauma. PET/CT provides anatomical localisation and characterisation of the infected area and has a crucial role in preoperative planning


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 33 - 33
1 Mar 2021
Woodmass J McRae S Malik S Dubberley J Marsh J Old J Stranges G Leiter J MacDonald P
Full Access

When compared to magnetic resonance imaging (MRI), ultrasound (US) performed by experienced users is an inexpensive tool that has good sensitivity and specificity for diagnosing rotator cuff (RC) tears. However, many practitioners are now utilizing in-office US with little to no formal training as an adjunct to clinical evaluation in the management of RC pathology. The purpose of our study was to determine if US without formal training is effective in managing patients with a suspected RC tear. This was a single centre prospective observational study. Five fellowship-trained surgeons each examined 50 participants referred for a suspected RC tear (n= 250). Patients were screened prior to the consultation and were included if ≥ 40 years old, had an MRI of their affected shoulder, had failed conservative treatment of at least 6 months, and had ongoing pain and disability. Patients were excluded if they had glenohumeral instability, evidence of major joint trauma, or osteonecrosis. After routine clinical exam, surgeons recorded their treatment plan (“No Surgery”, “Uncertain”, or “Surgery”). Surgeons then performed an in-office diagnostic US followed by an MRI and documented their treatment plan after each imaging study. Interrater reliability was analyzed using a kappa statistic to compare clinical to ultrasound findings and ultrasound findings to MRI, normal and abnormal categorization of biceps, supraspinatus, and subscapularis. Following clinical assessment, the treatment plan was recorded as “No Surgery” in 90 (36%), “Uncertain” in 96 (39%) of cases, “Surgery” in 61 (25%) cases, and incomplete in 3 (2%). In-office US allowed resolution of 68 (71%) of uncertain cases with 227 (88%) of patients having a definitive treatment plan. No patients in the “No Surgery” group had a change in treatment plan. After MRI, 16 (6%) patients in the “No Surgery” crossed-over to the “Surgery” group after identification of full-thickness tears, larger than expected tears or alternate pathology (e.g., labral tear). The combination of clinical examination and in-office US may be an effective method in the initial management of patients with suspected rotator cuff pathology. Using this method, a definitive diagnosis and treatment plan was established in 88% of patients with the remaining 12% requiring an MRI. A small percentage (6%) of patients with larger than expected full-thickness rotator cuff tears and/or alternate glenohumeral pathology (e.g., labral tear) would be missed at initial evaluation


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 41 - 41
1 Oct 2019
Braly HL Rodriguez D Schroder S Thomas J Delgadillo LE Noble PC
Full Access

Introduction. The Vancouver Classification System presents a systematic approach to classification of periprosthetic fractures of the proximal femur (PFPFs) that has been validated in previous studies. However, with the introduction of tapered fluted stems and cable plates since the introduction of the Vancouver System, the connection between fracture class and the preferred method of treatment is often unclear. The present study was undertaken to identify fracture patterns surrounding contemporary femoral stems and the relationship between the current method of treatment and the Vancouver Class of the periprosthetic fracture. Methods. Three experienced joint surgeons collected plain radiographs (AP and lateral) and CT/MR scans (n=40) from 72 cases of Vancouver A or B periprosthetic fractures performed over the period 2016–2018. We identified the mode of primary stem fixation and the Vancouver grade of the fracture (A, B1, B2 or B3). Two independent investigators examined all imaging studies and the intraoperative records and recorded: (i) and the location and distribution of the fracture surfaces, and (ii) the presence of incomplete cortical fractures that had initiated within the femoral cortex without completing propagation and (iii) the method of operative treatment. These data were analyzed to examine the incidence of fractures within more than one femoral zone and differences in the fracture patterns corresponding to each Vancouver class. Results. One fifth (21%) of fractures were Type A with the remainder consisting predominantly of Type B2 (39%), with approximately equal proportions of Type B1 (22%) and B3 (18%) fractures. In almost half of Type B2 fractures (a loose femoral stem and a fracture adjacent to the prosthesis), fractures were also present within the metaphysis (ie. Type A+B). In the presence of a cementless femoral stem, fractures often occurred adjacent to the uncoated surface of the stem distal to the proximal ingrowth surface. Type B2 and B3 femurs had similar fracture patterns and degrees of comminution, though their method of treatment differed significantly. Incomplete fractures were identified in every Vancouver class (entire sample: 22%), especially in association with loose stems in poor quality bone (Type B3; 38% of cases). Conclusions. Approximately two-thirds of periprosthetic femoral fractures involve a loose femoral component (ie Types B2 and B3), though bone quality impacts operative treatment. In cementless stems, Vancouver Type B fractures often occur in the unbonded diaphysis between the distal edge of the ingrowth surface and immediately below the stem tip. Incomplete fractures are present in a surprising proportion of cases, suggesting that careful examination of imaging studies is needed to prevent fracture propagation due to inadequate fixation. CT scans are a useful adjunct to supplement plain radiographs. For any tables or figures, please contact the authors directly


Bone & Joint Open
Vol. 5, Issue 2 | Pages 139 - 146
15 Feb 2024
Wright BM Bodnar MS Moore AD Maseda MC Kucharik MP Diaz CC Schmidt CM Mir HR

Aims

While internet search engines have been the primary information source for patients’ questions, artificial intelligence large language models like ChatGPT are trending towards becoming the new primary source. The purpose of this study was to determine if ChatGPT can answer patient questions about total hip (THA) and knee arthroplasty (TKA) with consistent accuracy, comprehensiveness, and easy readability.

Methods

We posed the 20 most Google-searched questions about THA and TKA, plus ten additional postoperative questions, to ChatGPT. Each question was asked twice to evaluate for consistency in quality. Following each response, we responded with, “Please explain so it is easier to understand,” to evaluate ChatGPT’s ability to reduce response reading grade level, measured as Flesch-Kincaid Grade Level (FKGL). Five resident physicians rated the 120 responses on 1 to 5 accuracy and comprehensiveness scales. Additionally, they answered a “yes” or “no” question regarding acceptability. Mean scores were calculated for each question, and responses were deemed acceptable if ≥ four raters answered “yes.”


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 93 - 93
1 Jul 2020
Conlin C Ogilvie-Harris D Phillips L Murnaghan L Theodoropoulos JS Matthies N
Full Access

The purpose of this study was to determine whether the reasons for delay to surgery are secondary to health system constraints or patient factors. This study explored factors that contribute to patients' delay to surgery as well as how patients perceive the delay in surgery to have affected their treatment and care. Semi-structured qualitative interviews were conducted with 30 patients aged 18 to 50 years old who had undergone arthroscopic ACL reconstruction. Qualitative data analysis was performed in accordance with the Straus and Corbin theory to derive codes, categories and themes. Patient interviews revealed three overarching themes regarding delay to ACL reconstruction surgery: access to care, finances and work, and personal advocacy. Elements of those factors were shown to influence the timing of ACL reconstruction surgery. Less common factors included choice of imaging study (i.e., ultrasound), geography, and family commitments. Patients' perceptions of delay in access to care was overwhelming due to the wait time for MRI. Several patients also described significant self-advocacy required to navigate the healthcare system, suggesting that some level of medical literacy may be necessary to gain timely access to surgery. Once patients had seen the surgeon, few patients described untimely delay to surgery, suggesting that OR resources are adequate. Recommendations to decrease delays to ACL reconstruction surgery include better access to MRI and broader education of non-surgical healthcare providers to help navigate access to surgery


Bone & Joint Research
Vol. 12, Issue 3 | Pages 202 - 211
7 Mar 2023
Bai Z Shou Z Hu K Yu J Meng H Chen C

Aims

This study was performed to explore the effect of melatonin on pyroptosis in nucleus pulposus cells (NPCs) and the underlying mechanism of that effect.

Methods

This experiment included three patients diagnosed with lumbar disc herniation who failed conservative treatment. Nucleus pulposus tissue was isolated from these patients when they underwent surgical intervention, and primary NPCs were isolated and cultured. Western blotting, reverse transcription polymerase chain reaction, fluorescence staining, and other methods were used to detect changes in related signalling pathways and the ability of cells to resist pyroptosis.


Bone & Joint Research
Vol. 13, Issue 6 | Pages 294 - 305
17 Jun 2024
Yang P He W Yang W Jiang L Lin T Sun W Zhang Q Bai X Sun W Guo D

Aims

In this study, we aimed to visualize the spatial distribution characteristics of femoral head necrosis using a novel measurement method.

Methods

We retrospectively collected CT imaging data of 108 hips with non-traumatic osteonecrosis of the femoral head from 76 consecutive patients (mean age 34.3 years (SD 8.1), 56.58% male (n = 43)) in two clinical centres. The femoral head was divided into 288 standard units (based on the orientation of units within the femoral head, designated as N[Superior], S[Inferior], E[Anterior], and W[Posterior]) using a new measurement system called the longitude and latitude division system (LLDS). A computer-aided design (CAD) measurement tool was also developed to visualize the measurement of the spatial location of necrotic lesions in CT images. Two orthopaedic surgeons independently performed measurements, and the results were used to draw 2D and 3D heat maps of spatial distribution of necrotic lesions in the femoral head, and for statistical analysis.


Bone & Joint Research
Vol. 12, Issue 12 | Pages 722 - 733
6 Dec 2023
Fu T Chen W Wang Y Chang C Lin T Wong C

Aims

Several artificial bone grafts have been developed but fail to achieve anticipated osteogenesis due to their insufficient neovascularization capacity and periosteum support. This study aimed to develop a vascularized bone-periosteum construct (VBPC) to provide better angiogenesis and osteogenesis for bone regeneration.

Methods

A total of 24 male New Zealand white rabbits were divided into four groups according to the experimental materials. Allogenic adipose-derived mesenchymal stem cells (AMSCs) were cultured and seeded evenly in the collagen/chitosan sheet to form cell sheet as periosteum. Simultaneously, allogenic AMSCs were seeded onto alginate beads and were cultured to differentiate to endothelial-like cells to form vascularized bone construct (VBC). The cell sheet was wrapped onto VBC to create a vascularized bone-periosteum construct (VBPC). Four different experimental materials – acellular construct, VBC, non-vascularized bone-periosteum construct, and VBPC – were then implanted in bilateral L4-L5 intertransverse space. At 12 weeks post-surgery, the bone-forming capacities were determined by CT, biomechanical testing, histology, and immunohistochemistry staining analyses.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 80 - 80
1 Aug 2020
Montgomery S Schneider P Kooner S
Full Access

Three dimensional printing is an emerging new technology in medicine and the current educational value of 3D printed fracture models is unknown. The delayed surgery and need for CT imaging make calcaneal fractures an ideal scenario for preoperative 3D printed (3Dp) fracture models. The goal of this study is to assess if improvements in fracture understanding and surgical planning can be realized by trainees when they are given standard CT imaging and a 3Dp model compared to standard CT imaging and a virtual 3D rendering (3D CT). Ethics approval was granted for a selection of calcaneal fracture imaging studies to be collected through a practice audit of a senior orthopaedic trauma surgeon. 3Dp models were created in house. Digital Imaging and Communications in Medicine (DICOM) files of patient CT scans were obtained from local servers in an anonymized fashion. DICOM files were then converted to .STL models using the Mimics inPrint 2.0 (Materialise NV, Leuven, Belgium) software. Models were converted into a .gcode file through a slicer program (Simplify3D, Blue Ash, OH USA). The .gcode files were printed on a TEVO Little Monster Delta FDM printer (TEVO USA, CO USA) using 1.75mm polylactic acid (PLA) filament. Study participants rotated through 10 workstations viewing CT images and either a digital 3D volume rendering or 3Dp model of the fractured calcaneus. A questionnaire at each workstation assessed fracture classification, proposed method of treatment, confidence with fracture understanding and satisfaction with the accuracy of the 3Dp model or 3D volume rendering. Participants included current orthopaedic surgery trainees and staff surgeons. A total of 16 residents and five staff completed the study. Ten fracture cases were included in the analysis for time, confidence of fracture understanding, perceived model accuracy and treatment method. Eight fracture cases were included for assessment of diagnosis. There were no cases that obtained universal agreement on either Sanders classification or treatment method from staff participants. Residents in their final year of studies had the quickest mean time of assessment (60 +/− 24 sec.) and highest percentage of correct diagnoses (83%) although these did not reach significance compared to the other residency years. There was a significant increase in confidence of fracture understanding with increasing residency year. Also, confidence was improved in cases where a 3Dp model was available compared to conventional CT alone although this improvement diminished with increasing residency year. Perceived accuracy of the cases with 3Dp models was significantly higher than cases without models (7 vs 5.5 p < 0.0001). This is the first study to our knowledge to assess trainee confidence as a primary outcome in the assessment of the educational value of 3Dp models. This study was able to show that a 3Dp model aides in the perceived accuracy of fracture assessment and showed an improvement in trainee confidence, although the effect on confidence seems to diminish with increasing residency year. We propose that 3D printed calcaneal fracture models are a beneficial educational tool for junior level trainees and the role of 3Dp models for other complex orthopaedic presentations should be explored


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 102 - 102
1 Jul 2020
Castano D Grammatopoulos G Salimian A Beaulé P
Full Access

During a periacetabular osteotomy (PAO), intra-operative assessment of correction of acetabular parameters is typically performed using fluoroscopy of the hip, a technique that has not been shown to produce predictable measurements. Furthermore, paralysing agents are used in order to facilitate dissection and fragment mobilization. The effect of paralysing agents on spino-pelvic posture is yet to be investigated. This study aims to: 1. Compare the reliability of intra-operative x-rays versus hip fluoroscopy in the assessment of acetabular fragment correction and 2. Evaluate the effect of changes in spino-pelvic alignment on the assessment of acetabular correction. An IRB approved, retrospective review of all patients who underwent a PAO at our institution between 2006–2018 was performed. Patient demographic data was collected and all available imaging studies were retrieved. Patients were excluded if there was no available to review intra-operative AP pelvis x-ray or intra-operative fluoroscopic PA image of the hip. Using a validated hip analysis software (Hip2Norm), the lateral center edge angle (LCEA) and acetabular index (AI) of plain radiographs were measured. The sacro-femoral-pubic angle (SFP), along with the LCEA and AI of the fluoroscopic image were measured using ImageJ. A oneway ANOVA was used to detect differences between measured parameters in the intra-operative x-ray, the post-operative x-ray and the fluoroscopic image. A total of 93 patients were identified. 26 patients were excluded due to missing data. The mean LCEA in the post-operative, intra-operative, and fluoroscopic groups were as follows: 33.67° (range 5.3° to 52.4°), 30.71°(range 9° to 55.6°), and 29.23°(range 12.4° to 51.4°) respectively. The mean AI in the post-operative, intra-operative, and fluoroscopic groups were as follows: −0.65° (range −18.10° to 27.30°), 0.35°(range −16.10° to 17.20°), and 5.54°(range −11.66° to 27.83°) respectively. When comparing intra-operative to post-operative plain radiographs, there was no statistically significant difference in AI (ΔAI −1±1.29° p=0.71) or LCEA (ΔLCEA 2.95±1.38° p=0.09). When comparing fluoroscopy to post-operative plain radiographs, there was a statistically significant difference in AI (ΔAI −6.21±1.29° p < 0 .0001) as well as LCEA (ΔLCEA 4.44±1.38° p < 0 .0001). Statistical analysis revealed no influence of demographics (age, BMI, gender), on acetabular correction parameters. The mean SPF angles measured from intra-operative and post-operative x-rays were 69.32±5.11° and 70.45±5.52°. There was a statistically significant difference between these 2 measurements with a ΔSFP of 1.03° (p < 0 .0001). The results of our study show that the use of intra-operative x-ray for the assessment of LCEA and AI is more reliable than fluoroscopic images. Further, we found a difference in SFP angle, which offers an indirect assessment of pelvic tilt, between the intra-operative and the post-operative plain x-rays. This suggests that there are changes in pelvic tilt during the surgery, which can be attributed to either patient positioning or changes in spino-pelvic posture secondary to the paralysing agents used by the anesthetists. The use of intra-operative x-rays as well as the effect of paralysing agents on spino-pelvic alignment should be considered by surgeons performing PAO's


Bone & Joint Open
Vol. 3, Issue 9 | Pages 674 - 683
1 Sep 2022
Singh P Jami M Geller J Granger C Geaney L Aiyer A

Aims

Due to the recent rapid expansion of scooter sharing companies, there has been a dramatic increase in the number of electric scooter (e-scooter) injuries. Our purpose was to conduct a systematic review to characterize the demographic characteristics, most common injuries, and management of patients injured from electric scooters.

Methods

We searched PubMed, EMBASE, Scopus, and Web of Science databases using variations of the term “electric scooter”. We excluded studies conducted prior to 2015, studies with a population of less than 50, case reports, and studies not focused on electric scooters. Data were analyzed using t-tests and p-values < 0.05 were considered significant.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 91 - 91
1 Feb 2020
Chun K Kwon H Kim K Chun C
Full Access

Purpose. The aim of this study was to assess the clinical and radiological result of the usage of chip bone graft in non-contained type bone defect in primary or revision total knee arthroplasty patients. Subjects and Methods. We investigated 32 patients who had underwent primary or revision total knee arthroplasty from March, 2014 to February, 2017 in our hospital, who had non-contained type of defect. The mean age was 73.1 years. 5 of them were males, while 27 of them were females. 7 of them were primary total knee arthroplasty patients, while 25 of them were revision patients. 8 of them had chip bone graft used both in the femur and tibia. 9 of them had chip bone graft used only in the tibia. The other 15 had chip bone graft used only in the femur. Wire-mesh was used in the 9 patients who had chip bone graft used only in the medial side of the tibia. We used KOOS (Knee injury and osteoarthritis outcome score), HSS (Hospital for Special Surgery knee service rating system) and WOMAC scores to assess the clinical result, before the surgery and at the last follow-up. In addition, we had follow-up x-rays and 3D CT done for the patients to check the mean bone union period. In addition, overall radiologic imaging studies were used for complications such as loosening, osteolysis and lesions with radiolucency. Result. The Mean follow-up period was 2.7 years (range; 2.1 to 5). The Mean preoperative KOOS was 102.8 (range; 47 to 132), while it became 31.8 postoperatively (range; 20 to 45). The mean HSS was 13.1 (range; 6 to 35), while it became 35.9 postoperatively (range; 24 to 64). The mean WOMAC was 82.9 (range; 62 to 92), while it became 22.5 postoperatively (range; 13 to 30). According to follow-up x-ray and CT, the mean bone union period was 10.6 months (range: 10 to 13). In follow-up 3D CT of all cases, we could check cortical healing and new bone formation, seen as medium to high-attenuating conglomerate. The graft-host junction showed trabecular ingrowth, while the medullary canal showed fibrous ingrowth. Radiologically, there was no complication such as loosening, osteolysis, migration and radiolucent lines around the stems or cement mantles. In addition, there was no complication such as infection. Conclusion. Chip bone graft is not a commonly used method for bone defect in total knee arthroplasty. According to the result of the usage of chip bone graft in primary or revision total knee arthroplasty with non-contained type of bone defect, it showed favorable result for the subject patients. Therefore, we can consider it as one of the effective methods to manage non-contained bone defect in knee arthroplasty. Keywords. Revision TKA, chip bone graft, wire-mesh, non-contained bone defect. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 77 - 77
1 Mar 2021
Ataei A Eggermont F Baars M Linden Y Rooy J Verdonschot N Tanck E
Full Access

Patients with advanced cancer can develop bone metastases in the femur which are often painful and increase the risk of pathological fracture. Accurate segmentation of bone metastases is, amongst others, important to improve patient-specific computer models which calculate fracture risk, and for radiotherapy planning to determine exact radiation fields. Deep learning algorithms have shown to be promising to improve segmentation accuracy for metastatic lesions, but require reliable segmentations as training input. The aim of this study was to investigate the inter- and intra-operator reliability of manual segmentation of femoral metastatic lesions and to define a set of lesions which can serve as a training dataset for deep learning algorithms. F. CT-scans of 60 advanced cancer patients with a femur affected with bone metastases (20 osteolytic, 20 osteoblastic and 20 mixed) were used in this study. Two operators were trained by an experienced radiologist and then segmented the metastatic lesions in all femurs twice with a four-week time interval. 3D and 2D Dice coefficients (DCs) were calculated to quantify the inter- and intra-operator reliability of the segmentations. We defined a DC>0.7 as good reliability, in line with a statistical image segmentation study. Mean first and second inter-operator 3D-DCs were 0.54 (±0.28) and 0.50 (±0.32), respectively. Mean intra-operator I and II 3D-DCs were 0.56 (±0.28) and 0.71 (±0.23), respectively. Larger lesions (>60 cm. 3. ) scored higher DCs in comparison with smaller lesions. This study reveals that manual segmentation of metastatic lesions is challenging and that the current manual segmentation approach resulted in dissatisfying outcomes, particularly for lesions with small volumes. However, segmentation of larger lesions resulted in a good inter- and intra-operator reliability. In addition, we were able to select 521 slices with good segmentation reliability that can be used to create a training dataset for deep learning algorithms. By using deep learning algorithms, we aim for more accurate automated lesion segmentations which might be used in computer modelling and radiotherapy planning