Aims. The first metatarsal
Purpose: To ascertain whether the methods of
Purpose: In slipped capital femoral epiphysis (SCFE) with increasing slip angle and increasing impingement, pain, stiffness, limping and degenerative change may follow. Currently there are no accepted guidelines to guide management in patients with stable SCFE. The main purpose of this study was to evaluate the proximal femoral geometry in stable SCFE using a postero-anterior radiograph of the hip in the extended position and to determine its use in predicting subsequent surgical management. Methods: Over a 7 year period, we evaluated the proximal femoral geometry in a consecutive series of 31 adolescents with stable SCFE using the
Aims. Comparison of the outcome between the supine or
Diagnostic interpretation error of paediatric musculoskeletal (MSK) radiographs can lead to late presentation of injuries that subsequently require more invasive surgical interventions with increased risks of morbidity. We aimed to determine the radiograph factors that resulted in diagnostic interpretation challenges for emergency physicians reviewing pediatric MSK radiographs. Emergency physicians provided diagnostic interpretations on 1,850 pediatric MSK radiographs via their participation in a web-based education platform. From this data, we derived interpretation difficulty scores for each radiograph using item response theory. We classified each radiograph by body region, diagnosis (fracture/dislocation absent or present), and, where applicable, the specific fracture location(s) and morphology(ies). We compared the interpretation difficulty scores by diagnosis, fracture location, and morphology. An expert panel reviewed the 65 most commonly misdiagnosed radiographs without a fracture/dislocation to identify normal imaging findings that were commonly mistaken for fractures. We included data from 244 emergency physicians, which resulted in 185,653 unique radiograph interpretations, 42,689 (23.0%) of which were diagnostic errors. For humerus, elbow, forearm, wrist, femur, knee, tibia-fibula radiographs, those without a fracture had higher interpretation difficulty scores relative to those with a fracture; the opposite was true for the hand, pelvis, foot, and ankle radiographs (p < 0 .004 for all comparisons). The descriptive review demonstrated that specific normal anatomy, overlapping bones, and external artefact from muscle or skin folds were often mistaken for fractures. There was a significant difference in difficulty score by anatomic locations of the fracture in the elbow, pelvis, and ankle (p < 0 .004 for all comparisons). Ankle and elbow growth plate, fibular avulsion, and humerus condylar were more difficult to diagnose than other fracture patterns (p < 0 .004 for all comparisons). We identified actionable learning opportunities in paediatric MSK radiograph interpretation for emergency physicians. We will use this information to design targeted education to referring emergency physicians and their trainees with an aim to decrease delayed and missed paediatric MSK injuries.
Diagnostic interpretation error of paediatric musculoskeletal (MSK) radiographs can lead to late presentation of injuries that subsequently require more invasive surgical interventions with increased risks of morbidity. We aimed to determine the radiograph factors that resulted in diagnostic interpretation challenges for emergency physicians reviewing pediatric MSK radiographs. Emergency physicians provided diagnostic interpretations on 1,850 pediatric MSK radiographs via their participation in a web-based education platform. From this data, we derived interpretation difficulty scores for each radiograph using item response theory. We classified each radiograph by body region, diagnosis (fracture/dislocation absent or present), and, where applicable, the specific fracture location(s) and morphology(ies). We compared the interpretation difficulty scores by diagnosis, fracture location, and morphology. An expert panel reviewed the 65 most commonly misdiagnosed radiographs without a fracture/dislocation to identify normal imaging findings that were commonly mistaken for fractures. We included data from 244 emergency physicians, which resulted in 185,653 unique radiograph interpretations, 42,689 (23.0%) of which were diagnostic errors. For humerus, elbow, forearm, wrist, femur, knee, tibia-fibula radiographs, those without a fracture had higher interpretation difficulty scores relative to those with a fracture; the opposite was true for the hand, pelvis, foot, and ankle radiographs (p < 0 .004 for all comparisons). The descriptive review demonstrated that specific normal anatomy, overlapping bones, and external artefact from muscle or skin folds were often mistaken for fractures. There was a significant difference in difficulty score by anatomic locations of the fracture in the elbow, pelvis, and ankle (p < 0 .004 for all comparisons). Ankle and elbow growth plate, fibular avulsion, and humerus condylar were more difficult to diagnose than other fracture patterns (p < 0 .004 for all comparisons). We identified actionable learning opportunities in paediatric MSK radiograph interpretation for emergency physicians. We will use this information to design targeted education to referring emergency physicians and their trainees with an aim to decrease delayed and missed paediatric MSK injuries.
Introduction: Energy storing tendons, such as the human Achilles tendon, suffer a much higher incidence of rupture than non- energy storing positional tendons, such as the anterior tibialis tendon. Similarly, in the horse partial rupture of the energy storing superficial digital flexor tendon (SDFT) and suspensory ligament (SL) occurs much more frequently than to the deep digital flexor tendon (DDFT) and common digital extensor tendon (CDET) which are not involved in energy storage. In order to function effectively, energy storing tendons experience strains during high speed locomotion which are much closer to failure strain than non-energy storing tendons. Therefore, these tendons are likely to sustain high levels of microdamage, hence cell metabolism may also be higher in order to repair damage and maintain matrix integrity. Maintenance of the matrix requires not only synthesis of new matrix components but also degradation of matrix macromolecules which is achieved, in part, by a family of matrix metalloproteinase enzymes (MMPs). In this study we test the hypothesis that the energy storing equine SDFT and SL which are
The role of anconeus in elbow stability has been a long-standing debate. Anatomical and electromyographic studies have suggested a potential role as a stabilizer. However, to our knowledge, no clinical or biomechanical studies have investigated its role in improving the stability of a lateral collateral ligament (LCL) deficient elbow. Seven cadaveric upper extremities were mounted in an elbow motion simulator in the varus position. An LCL injured model was created by sectioning of the common extensor origin, and the LCL. The anconeus tendon and its aponeurosis were sutured in a Krackow fashion and tensioned to 10N and 20N through a transosseous tunnel at its origin. Varus-valgus angles and ulnohumeral rotations were recorded using an electromagnetic tracking system during simulated active elbow flexion with the forearm pronated and supinated. During active motion, the injured model resulted in a significant increase in varus angulation (5.3°±2.9°, P=.0001
The clinical diagnosis of distal radioulnar joint (DRUJ) instability remains challenging. The current diagnostic gold standard is a dynamic computerized topography (CT) scan. This investigation compares the affected and normal wrists in multiple static positions of forearm rotation.. However, its accuracy has been questioned, as the wrist is unloaded and not placed under stress. This may fail to capture DRUJ instability that does not result in static malalignment between the ulnar head and sigmoid notch. The purpose of this biomechanical study was to evaluate the effectiveness of both dynamic and stress CT scans in detecting DRUJ instability. A customized DRUJ arthrometer was designed that allows for both static positioning, as well as dorsal and volar loading at the DRUJ in various degrees of forearm rotation. Ten fresh frozen cadavers were prepared and mounted in the apparatus. CT scans were performed both in the unloaded condition (dynamic CT) and with each arm subjected to a standardized 50N volar and dorsal force (stress CT) in neutral and maximum
Aims. Isolated fractures of the ulnar diaphysis are uncommon, occurring at a rate of 0.02 to 0.04 per 1,000 cases. Despite their infrequency, these fractures commonly give rise to complications, such as nonunion, limited forearm
Osteotomies in the musculoskeletal system are joint preserving procedures to correct the alignment of the patient. In the lower limb, most of the pre-operative planning is performed on full leg weightbearing radiographs. However, these images contain a 2-dimensional projection of a 3-dimensional deformity, lack a clear visualization of the joint surface and are
Tendon injuries present a major clinical challenge, as they necessitate surgical intervention and are
Approximately 30% of general practice consultations for musculoskeletal pain are related to tendon disorders, causing substantial personal suffering and enormous related healthcare costs. Treatments are often
Freehand distal interlocking of intramedullary nails is technical demanding and
This study aims to compare the outcomes of Volar locking plating (VLP) versus percutaneous Kirschner wires (K-wire) fixation for surgical management of distal radius fractures. We systematically searched multiple databases, including MEDLINE for randomized controlled trials (RCTs) comparing outcomes of VLP fixation and K-wire for treatment of distal radius fracture in adults. The methodological quality of each study was assessed by the Cochrane Risk of Bias tool. Patient-reported outcomes, functional outcomes, and complications at 1 year follow up were evaluated. Meta-analysis was performed using random-effects models and results presented as risk ratios (RRs) or mean differences (MDs) with 95% confidence interval (CI). 13 RCTs with 1336 participants met the inclusion criteria. Disabilities of the Arm, Shoulder and Hand (DASH) scores were significantly better for VLP fixation (MD= 2.15; 95% CI, 0.56-3.74; P = 0.01; I2=23%). No significant difference between the two procedures for grip strength measured in kilograms (MD= −3.84; 95% CI,-8.42-0.74; P = 0.10; I2=52%) and Patient-Rated Wrist Evaluation (PRWE) scores (MD= −0.06; 95% CI,-0.87-0.75; P = 0.89; I2=0%). K-wire treatment yielded significantly improved extension (MD= −4.30; P=0.04) but with no differences in flexion,
Energy storing tendons such as the human Achilles and equine superficial digital flexor tendon (SDFT) are
Introduction. The incidences of fragility fractures, often because of osteoporosis, are increasing. Research has moved towards bioresorbable scaffolds that provide temporary mechanical stability and promote osteogenesis. This research aims to fabricate a 3D printed composite Poly (l-lactic-co-glycolic acid)-strontium doped tricalcium phosphate (PLGA-SrTCP) scaffold and evaluate in an in vitro co culture study containing osteoporotic donor cells. Method. PLGA, PLGA TCP, and PLGA SrTCP scaffolds were produced using Fused Filament Fabrication (FFF). A four-group 35-day cell culture study was carried out using human bone marrow derived mesenchymal stem cells (hMSCs) from osteoporotic and control donors (monoculture) and hMSCs & human monocytes (hMCs) (Co culture). Outcome measures were biochemical assays, PCR, and cell imaging. Cells were cultured on scaffolds that had been pre-degraded for six weeks at 47°C prior to drying and gamma sterilisation. Result. 3D printed scaffolds were successfully produced by FFF. All groups in the study supported cell attachment onto the scaffolds, producing extracellular matrices as well as evidence of osteoclast cell structures. Osteoporotic cells increased CTSK activity and CAII activity and decreased ALP activity compared to controls. In control cultures, the addition of bTCP and bTCP/Sr to the PLGA reduced TRAP5b, CAII and ALP activity compared to PLGA alone. The addition of Sr did not show any differences between donors. Conclusion. This study details suitability of 3D printed polymer scaffolds for use in bone tissue applications. Both composite and pure polymer scaffolds promote osteogenesis in vitro. The introduction of ceramic filler and ion doping does not beneficially effect osteogenic potential and can reduce its ability compared to pure polymer. This study suggests the behaviour of control and osteoporotic cells are different and that osteoporotic cells are more
Osteoarthritis (OA) is the most common degenerative joint disorder. Its multifactorial etiology includes age, sex, joint overloading, genetic or nervous influences. In particular, the autonomic nervous system is increasingly gaining in importance. Its two branches, the sympathetic (SNS) and parasympathetic nervous system, are well-balanced under healthy conditions. OA patients seem to be
Standard fixation for intra-articular distal humerus fracture is open reduction and internal fixation (ORIF). However, high energy fractures of the distal humerus are often accompanied with soft tissue injuries and or vascular injuries which limits the use of internal fixation. In our report, we describe a highly complex distal humerus fracture that showed promising healing via a ring external fixator. A 26-year-old man sustained a Gustillo Anderson Grade IIIB intra-articular distal humerus fracture of the non-dominant limb with bone loss at the lateral column. The injury was managed with aggressive wound debridement and cross elbow stabilization via a hinged ring external fixator. Post operative wound managed with foam dressing. Post-operatively, early controlled mobilization of elbow commenced. Fracture union achieved by 9 weeks and frame removed once fracture united. No surgical site infection or non-union observed throughout follow up. At 2 years follow up, flexion - extension of elbow is 20°- 100°, forearm supination 65°, forearm
Introduction. The main postoperative complications in fixation of ulna shaft fractures are non-union and implant irritation using currently recommended 3.5-mm locking compression plates. An alternative approach using a combination of two smaller plates in orthogonal configuration has been proposed. The aim of this study was to compare the biomechanical properties of a single 3.5-mm locking compression plate versus double plating using one 2.5-mm and one 2.0-mm mandible plate in a human ulna shaft fracture model. Method. Eight pairs human ulnar specimens with a standardized 10-mm fracture gap were pairwise assigned for instrumentation with either a single 3.5-mm plate placed posteriorly, or for double plating using a 2.5-mm and a 2.0-mm mandible plate placed posteriorly under the flexor muscles and laterally under the extensor muscles. All constructs were initially non-destructively biomechanically tested in axial compression, torsion, and bending, which was followed by cyclic torsional loading to failure. Interfragmentary movements were monitored by means of optical motion tracking. Result. There were no significant differences between the two plating techniques for axial stiffness (p=0.335), torsional stiffness in supination (p=0.462), torsional stiffness in