Advertisement for orthosearch.org.uk
Results 1 - 20 of 4794
Results per page:

Aims. The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury. Methods. Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient’s initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed. Results. Patients treated with surgical fixation with wires had less dorsal angulation of the radius versus those treated in a moulded cast at six weeks after manipulation of the fracture; the mean difference of -4.13° was statistically significant (95% confidence interval 5.82 to -2.45). There was no evidence of a difference in radial shortening. However, there was no correlation between these radiological measurements and PROMs at any timepoint in the 12 months post-injury. Conclusion. For patients with a dorsally displaced distal radius fracture treated with a closed manipulation, surgical fixation with wires leads to less dorsal angulation on radiographs at six weeks compared with patients treated in a moulded plaster cast alone. However, the difference in dorsal angulation was small and did not correlate with patient-reported pain and function. Cite this article: Bone Jt Open 2024;5(2):132–138


Bone & Joint Open
Vol. 3, Issue 12 | Pages 960 - 968
23 Dec 2022
Hardwick-Morris M Wigmore E Twiggs J Miles B Jones CW Yates PJ

Aims. Leg length discrepancy (LLD) is a common pre- and postoperative issue in total hip arthroplasty (THA) patients. The conventional technique for measuring LLD has historically been on a non-weightbearing anteroposterior pelvic radiograph; however, this does not capture many potential sources of LLD. The aim of this study was to determine if long-limb EOS radiology can provide a more reproducible and holistic measurement of LLD. Methods. In all, 93 patients who underwent a THA received a standardized preoperative EOS scan, anteroposterior (AP) radiograph, and clinical LLD assessment. Overall, 13 measurements were taken along both anatomical and functional axes and measured twice by an orthopaedic fellow and surgical planning engineer to calculate intraoperator reproducibility and correlations between measurements. Results. Strong correlations were observed for all EOS measurements (r. s. > 0.9). The strongest correlation with AP radiograph (inter-teardrop line) was observed for functional-ASIS-to-floor (functional) (r. s. = 0.57), much weaker than the correlations between EOS measurements. ASIS-to-ankle measurements exhibited a high correlation to other linear measurements and the highest ICC (r. s. = 0.97). Using anterior superior iliac spine (ASIS)-to-ankle, 33% of patients had an absolute LLD of greater than 10 mm, which was statistically different from the inter-teardrop LLD measurement (p < 0.005). Discussion. We found that the conventional measurement of LLD on AP pelvic radiograph does not correlate well with long leg measurements and may not provide a true appreciation of LLD. ASIS-to-ankle demonstrated improved detection of potential LLD than other EOS and radiograph measurements. Full length, functional imaging methods may become the new gold standard to measure LLD. Cite this article: Bone Jt Open 2022;3(12):960–968


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 44 - 44
23 Feb 2023
Kruger P Lynskey S Sutherland A
Full Access

The attitudes of orthopaedic surgeons regarding radiology reporting is not well-described in the literature. We surveyed Orthopaedic Surgeons in Australia and New Zealand to assess if they routinely review formal radiology reports. An anonymized, 14 question online survey was distributed to consultant surgeons of the Australian and New Zealand Orthopaedic Associations (AOA, NZOA). Two hundred respondents completed the survey (Total number of Fellows: 283 NZOA, 1185 AOA). 18.5% of respondents always reviewed the formal Radiology report, 44.5% most of the time, 35% sometimes and 2% never. By imaging modality, MRI reports were the most frequently reviewed (92%), followed by ultrasound (74%) and nuclear medicine (63%). Only 10% of surgeons consulted formal reports for plain radiography. 55% of surgeons were still likely to disagree with the MRI report, followed by 46% for plain radiography. In cases of disagreement, only 21% of surgeons would always contact the reporting radiologist. The majority of Surgeons (85.5%) think there should be more collaboration between the disciplines, although only 50.5% had regular attendance of a Radiologist at their departmental audit. This survey reveals that the majority of orthopaedic surgeons are not routinely reading radiology reports. This points towards a need for further interdisciplinary collaboration. To our knowledge, this is the first survey directly assessing attitudes of orthopaedic surgeons towards radiology reports


Bone & Joint Open
Vol. 5, Issue 10 | Pages 825 - 831
3 Oct 2024
Afghanyar Y Afghanyar B Loweg L Drees P Gercek E Dargel J Rehbein P Kutzner KP

Aims. Limited implant survival due to aseptic cup loosening is most commonly responsible for revision total hip arthroplasty (THA). Advances in implant designs and materials have been crucial in addressing those challenges. Vitamin E-infused highly cross-linked polyethylene (VEPE) promises strong wear resistance, high oxidative stability, and superior mechanical strength. Although VEPE monoblock cups have shown good mid-term performance and excellent wear patterns, long-term results remain unclear. This study evaluated migration and wear patterns and clinical and radiological outcomes at a minimum of ten years’ follow-up. Methods. This prospective observational study investigated 101 cases of primary THA over a mean duration of 129 months (120 to 149). At last follow-up, 57 cases with complete clinical and radiological outcomes were evaluated. In all cases, the acetabular component comprised an uncemented titanium particle-coated VEPE monoblock cup. Patients were assessed clinically and radiologically using the Harris Hip Score, visual analogue scale (pain and satisfaction), and an anteroposterior radiograph. Cup migration and polyethylene wear were measured using Einzel-Bild-Röntgen-Analyze software. All complications and associated treatments were documented until final follow-up. Results. Clinical assessment showed persistent major improvement in all scores. On radiological assessment, only one case showed a lucent line (without symptoms). At last follow-up, wear and migration were below the critical thresholds. No cup-related revisions were needed, indicating an outstanding survival rate of 100%. Conclusion. Isoelastic VEPE cups offer high success rates and may prevent osteolysis, aseptic loosening, and the need for revision surgeries in the long term. However, longer follow-up is needed to validate our findings and confirm the advantages offered by this cup. Cite this article: Bone Jt Open 2024;5(10):825–831


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 4 - 4
1 Dec 2022
Bazzocchi A
Full Access

Imaging can provide valuable information about the function of tissues and organs. The capacity for detecting and measuring imaging biomarkers of biological activities, allows for a better understanding of the pathophysiology of any process in the human body, including the musculoskeletal system. This is of particular importance in oncologic, metabolic and rheumatologic diseases, but not limited to these. In the domain of the musculoskeletal system, functional imaging also means to be able to address biomechanical evaluations. Weight-bearing imaging and dynamic studies have a prominent role. All imaging techniques (X-rays, CT, MR, ultrasound) are in demand, and offer different applications, specific equipment and novel methods for addressing this. Functional imaging is also essential to drive minimally invasive treatments – i.e. interventional radiology, and new treatment approaches move together with the advances on imaging guidance methods. On both the diagnostic and the interventional side, the increasing availability of dedicated equipment and the development of specific imaging methods and protocols greatly helps the transition from research to clinical practice


Bone & Joint Open
Vol. 4, Issue 3 | Pages 210 - 218
28 Mar 2023
Searle HKC Rahman A Desai AP Mellon SJ Murray DW

Aims. To assess the incidence of radiological lateral osteoarthritis (OA) at 15 years after medial unicompartmental knee arthroplasty (UKA) and assess the relationship of lateral OA with symptoms and patient characteristics. Methods. Cemented Phase 3 medial Oxford UKA implanted by two surgeons since 1998 for the recommended indications were prospectively followed. A 15-year cumulative revision rate for lateral OA of 5% for this series was previously reported. A total of 163 unrevised knees with 15-year (SD 1) anterior-posterior knee radiographs were studied. Lateral joint space width (JSW. L. ) was measured and severity of lateral OA was classified as: nil/mild, moderate, and severe. Preoperative and 15-year Oxford Knee Scores (OKS) and American Knee Society Scores were determined. The effect of age, sex, BMI, and intraoperative findings was analyzed. Statistical analysis included one-way analysis of variance and Kruskal-Wallis H test, with significance set at 5%. Results. The mean age was 80.6 years (SD 8.3), with 84 females and 79 males. The mean JSW. L. was 5.6 mm (SD 1.4), and was not significantly related to age, sex, or intraoperative findings. Those with BMI > 40 kg/m. 2. had a smaller JSW. L. than those with a ‘normal’ BMI (p = 0.039). The incidence of severe and moderate lateral OA were both 4.9%. Overall, 2/142 (1.4%) of those with nil/mild lateral OA, 1/8 (13%) with moderate, and 2/8 (25%) with severe subsequently had a revision. Those with severe (mean OKS 35.6 (SD 9.3)) and moderate OA (mean OKS 35.8 (SD 10.5)) tended to have worse outcome scores than those with nil/mild (mean OKS 39.5 (SD 9.2)) but the difference was only significant for OKS-Function (p = 0.044). Conclusion. This study showed that the rate of having severe or moderate radiological lateral OA at 15 years after medial UKA was low (both 4.9%). Although patients with severe or moderate lateral OA had a lower OKS than those with nil/mild OA, their mean scores (OKS 36) would be classified as good. Cite this article: Bone Jt Open 2023;4(3):210–218


Bone & Joint Open
Vol. 3, Issue 1 | Pages 20 - 28
10 Jan 2022
Fujii H Hayama T Abe T Takahashi M Amagami A Matsushita Y Otani T Saito M

Aims. Although the short stem concept in hip arthroplasty procedure shows acceptable clinical performance, we sometimes get unexplainable radiological findings. The aim of this retrospective study was to evaluate changes of radiological findings up to three years postoperatively, and to assess any potential contributing factors on such radiological change in a Japanese population. Methods. This is a retrospective radiological study conducted in Japan. Radiological assessment was done in accordance with predetermined radiological review protocol. A total of 241 hips were included in the study and 118 hips (49.0%) revealed radiological change from immediately after surgery to one year postoperatively; these 118 hips were eligible for further analyses. Each investigator screened whether either radiolucent lines (RLLs), cortical hypertrophy (CH), or atrophy (AT) appeared or not on the one-year radiograph. Further, three-year radiographs of eligible cases were reviewed to determine changes such as, disappeared (D), improved (I), stable (S), and progression (P). Additionally, bone condensation (BC) was assessed on the three-year radiograph. Results. CH was observed in 49 hips (21.1%), AT was observed in 63 hips (27.2%), and RLLs were observed in 34 hips (14.7%) at one year postoperatively. Among 34 hips with RLLs, 70.6% showed change of either D or I on the three-year radiograph. BC was observed in younger patients more frequently. Conclusion. The Fitmore stem works well in a Japanese population with favourable radiological change on hips with RLLs. Longer-term follow-up is required to determine clinical relevance. Cite this article: Bone Jt Open 2022;3(1):20–28


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1037 - 1040
15 Nov 2024
Wu DY Lam EKF

Aims. The first metatarsal pronation deformity of hallux valgus feet is widely recognized. However, its assessment relies mostly on 3D standing CT scans. Two radiological signs, the first metatarsal round head (RH) and inferior tuberosity position (ITP), have been described, but are seldom used to aid in diagnosis. This study was undertaken to determine the reliability and validity of these two signs for a more convenient and affordable preoperative assessment and postoperative comparison. Methods. A total of 200 feet were randomly selected from the radiograph archives of a foot and ankle clinic. An anteroposterior view of both feet was taken while standing on the same x-ray platform. The intermetatarsal angle (IMA), metatarsophalangeal angle (MPA), medial sesamoid position, RH, and ITP signs were assessed for statistical analysis. Results. There were 127 feet with an IMA > 9°. Both RH and ITP severities correlated significantly with IMA severity. RH and ITP were also significantly associated with each other, and the pronation deformities of these feet are probably related to extrinsic factors. There were also feet with discrepancies between their RH and ITP severities, possibly due to intrinsic torsion of the first metatarsal. Conclusion. Both RH and ITP are reliable first metatarsal pronation signs correlating to the metatarsus primus varus deformity of hallux valgus feet. They should be used more for preoperative and postoperative assessment. Cite this article: Bone Jt Open 2024;5(11):1037–1040


Bone & Joint Open
Vol. 3, Issue 11 | Pages 877 - 884
14 Nov 2022
Archer H Reine S Alshaikhsalama A Wells J Kohli A Vazquez L Hummer A DiFranco MD Ljuhar R Xi Y Chhabra A

Aims. Hip dysplasia (HD) leads to premature osteoarthritis. Timely detection and correction of HD has been shown to improve pain, functional status, and hip longevity. Several time-consuming radiological measurements are currently used to confirm HD. An artificial intelligence (AI) software named HIPPO automatically locates anatomical landmarks on anteroposterior pelvis radiographs and performs the needed measurements. The primary aim of this study was to assess the reliability of this tool as compared to multi-reader evaluation in clinically proven cases of adult HD. The secondary aims were to assess the time savings achieved and evaluate inter-reader assessment. Methods. A consecutive preoperative sample of 130 HD patients (256 hips) was used. This cohort included 82.3% females (n = 107) and 17.7% males (n = 23) with median patient age of 28.6 years (interquartile range (IQR) 22.5 to 37.2). Three trained readers’ measurements were compared to AI outputs of lateral centre-edge angle (LCEA), caput-collum-diaphyseal (CCD) angle, pelvic obliquity, Tönnis angle, Sharp’s angle, and femoral head coverage. Intraclass correlation coefficients (ICC) and Bland-Altman analyses were obtained. Results. Among 256 hips with AI outputs, all six hip AI measurements were successfully obtained. The AI-reader correlations were generally good (ICC 0.60 to 0.74) to excellent (ICC > 0.75). There was lower agreement for CCD angle measurement. Most widely used measurements for HD diagnosis (LCEA and Tönnis angle) demonstrated good to excellent inter-method reliability (ICC 0.71 to 0.86 and 0.82 to 0.90, respectively). The median reading time for the three readers and AI was 212 (IQR 197 to 230), 131 (IQR 126 to 147), 734 (IQR 690 to 786), and 41 (IQR 38 to 44) seconds, respectively. Conclusion. This study showed that AI-based software demonstrated reliable radiological assessment of patients with HD with significant interpretation-related time savings. Cite this article: Bone Jt Open 2022;3(11):877–884


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 102 - 102
1 Dec 2022
Gundavda M Lazarides A Burke Z Griffin A Tsoi K Ferguson P Wunder JS
Full Access

Cartilage lesions vary in the spectrum from benign enchondromas to highly malignant dedifferentiated chondrosarcomas. From the treatment perspective, enchondromas are observed, Grade 1 chondrosarcomas are curetted like aggressive benign tumors, and rest are resected like other sarcomas. Although biopsy for tissue diagnosis is the gold standard for diagnosis and grade determination in chondrosarcoma, tumor heterogeneity limits the grading in patients following a biopsy. In the absence of definite pre-treatment grading, a surgeon is therefore often in a dilemma when deciding the best treatment option. Radiology has identified aggressive features and aggressiveness scores have been used to try and grade these tumors based on the imaging characteristics but there have been very few published reports with a uniform group and large number of cases to derive a consistent scoring and correlation. The authors asked these study questions :(1) Does Radiology Aggressiveness and its Score correlate with the grade of chondrosarcoma? (2) Can a cut off Radiology Agressiveness Score value be used to guide the clinician and add value to needle biopsy information in offering histological grade dependent management?. A retrospective analysis of patients with long bone extremity intraosseous primary chondrosarcomas were correlated with the final histology grade for the operated patients and Radiological parameters with 9 parameters identified a priori and from published literature (radiology aggressiveness scores - RAS) were evaluated and tabulated. 137 patients were identified and 2 patients were eliminated for prior surgical intervention. All patients had tissue diagnosis available and pre-treatment local radiology investigations (radiographs and/or CT scans and MRI scans) to define the RAS parameters. Spearman correlation has indicated that there was a significant positive association between RAS and final histology grading of long bone primary intraosseous chondrosarcomas. We expect higher RAS values will provide grading information in patients with inconclusive pre-surgery biopsy to tumor grades and aid in correct grade dependant surgical management of the lesion. Prediction of dedifferentiated chondrosarcoma from higher RAS will be attempted and a correlation to obtain a RAS cut off, although this may be challenging to achieve due to the overlap of features across the intermediate grade, high grade and dedifferentiated grades. Radiology Aggressiveness correlates with the histologic grade in long bone extremity primary chondrosarcomas and the correlation of radiology and biopsy can aid in treatment planning by guiding us towards a low-grade neoplasm which may be dealt with intralesional extended curettage or high-grade lesion which need to be resected. Standalone RAS may not solve the grading dilemma of primary long bone intraosseous chondrosarcomas as the need for tissue diagnosis for confirming atypical cartilaginous neoplasm cannot be eliminated, however in the event of a needle biopsy grade or inconclusive open biopsy it may guide us towards a correlational diagnosis along with radiology and pathology for grade based management of the chondrosarcoma


Bone & Joint Research
Vol. 12, Issue 7 | Pages 412 - 422
4 Jul 2023
Ferguson J Bourget-Murray J Hotchen AJ Stubbs D McNally M

Aims. Dead-space management, following dead bone resection, is an important element of successful chronic osteomyelitis treatment. This study compared two different biodegradable antibiotic carriers used for dead-space management, and reviewed clinical and radiological outcomes. All cases underwent single-stage surgery and had a minimum one-year follow-up. Methods. A total of 179 patients received preformed calcium sulphate pellets containing 4% tobramycin (Group OT), and 180 patients had an injectable calcium sulphate/nanocrystalline hydroxyapatite ceramic containing gentamicin (Group CG). Outcome measures were infection recurrence, wound leakage, and subsequent fracture involving the treated segment. Bone-void filling was assessed radiologically at a minimum of six months post-surgery. Results. The median follow-up was 4.6 years (interquartile range (IQR) 3.2 to 5.4; range 1.3 to 10.5) in Group OT compared to 4.9 years (IQR 2.1 to 6.0; range 1.0 to 8.3) in Group CG. The groups had similar defect sizes following excision (both mean 10.9 cm. 3. (1 to 30)). Infection recurrence was higher in Group OT (20/179 (11.2%) vs 8/180 (4.4%), p = 0.019) than Group CG, as was early wound leakage (33/179 (18.4%) vs 18/180 (10.0%), p = 0.024) and subsequent fracture (11/179 (6.1%) vs 1.7% (3/180), p = 0.032). Group OT cases had an odds ratio 2.9-times higher of developing any one of these complications, compared to Group CG (95% confidence interval 1.74 to 4.81, p < 0.001). The mean bone-void healing in Group CG was better than in Group OT, in those with ≥ six-month radiological follow-up (73.9% vs 40.0%, p < 0.001). Conclusion. Local antibiotic carrier choice affects outcome in chronic osteomyelitis surgery. A biphasic injectable carrier with a slower dissolution time was associated with better radiological and clinical outcomes compared to a preformed calcium sulphate pellet carrier. Cite this article: Bone Joint Res 2023;12(7):412–422


Bone & Joint Research
Vol. 9, Issue 7 | Pages 333 - 340
1 Jul 2020
Mumith A Coathup M Edwards TC Gikas P Aston W Blunn G

Aims. Limb salvage in bone tumour patients replaces the bone with massive segmental prostheses where achieving bone integration at the shoulder of the implant through extracortical bone growth has been shown to prevent loosening. This study investigates the effect of multidrug chemotherapy on extracortical bone growth and early radiological signs of aseptic loosening in patients with massive distal femoral prostheses. Methods. A retrospective radiological analysis was performed on adult patients with distal femoral arthroplasties. In all, 16 patients were included in the chemotherapy group with 18 patients in the non-chemotherapy control group. Annual radiographs were analyzed for three years postoperatively. Dimensions of the bony pedicle, osseointegration of the hydroxyapatite (HA) collar surface, bone resorption at the implant shoulder, and radiolucent line (RLL) formation around the cemented component were analyzed. Results. A greater RLL score (p = 0.041) was observed at three years postoperatively, with those receiving chemotherapy showing greater radiological loosening compared with those not receiving chemotherapy. Chemotherapy patients experience osteolysis at the shoulder of the ingrowth collar over time (p < 0.001) compared with non-chemotherapy patients where osteolysis was not observed. A greater median percentage integration of the collar surface was observed in the non-chemotherapy group (8.6%, interquartile range (IQR) 0.0% to 37.9%; p = 0.021) at three years. Bone growth around the collar was observed in both groups, and no statistical difference in amount of extracortical bony bridging was seen. Conclusion. Multidrug chemotherapy affects the osseointegration of ingrowth collars and accelerates signs of radiological loosening. This may increase the risk of aseptic loosening in patients with massive segmental implants used to treat bone cancer. Cite this article: Bone Joint Res 2020;9(7):333–340


Bone & Joint Open
Vol. 5, Issue 3 | Pages 243 - 251
25 Mar 2024
Wan HS Wong DLL To CS Meng N Zhang T Cheung JPY

Aims

This systematic review aims to identify 3D predictors derived from biplanar reconstruction, and to describe current methods for improving curve prediction in patients with mild adolescent idiopathic scoliosis.

Methods

A comprehensive search was conducted by three independent investigators on MEDLINE, PubMed, Web of Science, and Cochrane Library. Search terms included “adolescent idiopathic scoliosis”,“3D”, and “progression”. The inclusion and exclusion criteria were carefully defined to include clinical studies. Risk of bias was assessed with the Quality in Prognostic Studies tool (QUIPS) and Appraisal tool for Cross-Sectional Studies (AXIS), and level of evidence for each predictor was rated with the Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) approach. In all, 915 publications were identified, with 377 articles subjected to full-text screening; overall, 31 articles were included.


Bone & Joint Research
Vol. 9, Issue 4 | Pages 182 - 191
1 Apr 2020
D’Ambrosio A Peduzzi L Roche O Bothorel H Saffarini M Bonnomet F

Aims. The diversity of femoral morphology renders femoral component sizing in total hip arthroplasty (THA) challenging. We aimed to determine whether femoral morphology and femoral component filling influence early clinical and radiological outcomes following THA using fully hydroxyapatite (HA)-coated femoral components. Methods. We retrospectively reviewed records of 183 primary uncemented THAs. Femoral morphology, including Dorr classification, canal bone ratio (CBR), canal flare index (CFI), and canal-calcar ratio (CCR), were calculated on preoperative radiographs. The canal fill ratio (CFR) was calculated at different levels relative to the lesser trochanter (LT) using immediate postoperative radiographs: P1, 2 cm above LT; P2, at LT; P3, 2 cm below LT; and D1, 7 cm below LT. At two years, radiological femoral component osseointegration was evaluated using the Engh score, and hip function using the Postel Merle d’Aubigné (PMA) and Oxford Hip Score (OHS). Results. CFR was moderately correlated with CCR at P1 (r = 0.44; p < 0.001), P2 (r = 0.53; p < 0.001), and CFI at P1 (r = − 0.56; p < 0.001). Absence of spot welds (n = 3, 2%) was associated with lower CCR (p = 0.049), greater CFI (p = 0.017), and lower CFR at P3 (p = 0.015). Migration (n = 9, 7%) was associated with lower CFR at P2 (p = 0.028) and P3 (p = 0.007). Varus malalignment (n = 7, 5%), predominantly in Dorr A femurs (p = 0.028), was associated with lower CFR at all levels (p < 0.05). Absence of spot welds was associated with lower PMA gait (p = 0.012) and migration with worse OHS (p = 0.032). Conclusion. This study revealed that femurs with insufficient proximal filling tend to have less favourable radiological outcomes following uncemented THA using a fully HA-coated double-tapered femoral component. Cite this article: Bone Joint Res. 2020;9(4):182–191


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 51 - 51
1 Jan 2013
Xypnitos F Sims A Weusten A Rangan A
Full Access

Background. Accurate and reproducible radiological assessment of shoulder replacement prostheses over time is important for identifying failure or to provide reassurance. A number of clearly defined radiological parameters have been described to help standardise the radiological assessment of prostheses. To our knowledge, this is the first study conducted to test the reproducibility and reliability of these measurements. Aim. The aim of this work was to test intraobserver reproducibility and interobserver reliability in the measurement of humeral component orientation (HCO), humeral head offset (HHO), humeral head size (HHS), humeral head height (HHH), and acromiohumeral distance (AHD.). Materials and methods. A cohort of 67 patients who had previously undergone shoulder replacement was identified. Two independent reviewers studied the same AP radiograph of each patient on two occasions, at an interval of one month. Results. There was strong agreement for measurements of humeral head size (ICC=0.83), moderate agreement for humeral head offset (0.66), humeral head height (0.68) and acromio-humeral distance (0.66) and fair agreement for humeral component orientation (0.44). Conclusions. Interobserver reliability and intraobserver reproducibility of radiological measurements are important factors to consider when designing longitudinal or multi-centre studies of shoulder replacement prostheses


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 49 - 49
1 Mar 2017
Twiggs J Theodore W Liu D Dickison D Bare J Miles B
Full Access

Introduction. Surgical planning for Patient Specific Instrumentation (PSI) in total knee arthroplasty (TKA) is based on static non-functional imaging (CT or MRI). Component alignment is determined prior to any assessment of clinical soft tissue laxity. This leads to surgical planning where assumptions of correctability of preoperative deformity are false and a need for intraoperative variation or abandonment of the PSI blocks occurs. The aim of this study is to determine whether functional radiology complements pre-surgical planning by identifying non-predictable patient variation in laxity. Method. Pre-operative CT's, standing radiographs and functional radiographs assessing coronal laxity at 20° flexion were collected for 20 patients. Varus/valgus laxity was assessed using the TELOS stress device (TELOS GmbH, Marburg, Germany, see Figure 1). The varus/valgus load was incrementally increased to either a maximum load of 150N or until the patient could not tolerate the discomfort. Radiographs were taken whilst the knee was held in the stressed position. CT scans were segmented and anatomical points landmarked. 2D–3D pose estimations were performed using the femur and tibia against the radiographs to determine knee alignment with each functional radiograph and so characterise the varus/valgus laxity. Results. The mean coronal alignment on CT and standing radiographs were 3.8° varus (SD, 5.6°) and 4.3° varus (SD, 6.7°) respectively. Of these, 5 of the knees were valgus aligned and 15 varus aligned in both standing and CT positions. The varus group had a mean of 5.9° in CT and 6.9° varus standing, while the valgus group had means of 4.4° valgus and 5.4° valgus in standing, indicating a collapse into further coronal malalignment while weightbearing. Each knee in the group had a laxity envelope calculated from the varus and valgus stressed radiographs. In the varus knees, the envelope ranged from 11.0° to 1.0° degree, with a mean of 5.1° (SD, 2.4°). In the valgus knees, the envelope ranged from 10.0° to 5.0° degrees, with a mean of 6.6° (SD, 2.3°), though this difference did not reach statistical significance. Using ±3° of neutral alignment as an indicator of correctable deformity, 7 of the 15 varus knees did not have a correctable deformity, while all of the valgus did. As determined by laxity limits, the CT and standing alignments were not well centered within their functional radiology groups. Specifically, for the valgus knees, 2 were near the valgus limit (lower quartile) of their laxity envelope, while for the varus knees, 9 were near their varus limit (upper quartile) and 2 at the valgus limit. In total, 65% of the knees did not have their standing alignment well centered on their functional laxity imits. Conclusions. Varus/valgus laxity in TKA appears to be subject specific and divorced from static radiological parameters. Surgical planning without reproducible clinical assessments of coronal laxity may not be sufficient to obtain a balanced TKA while avoiding ligament releases. Functional radiographs may be a viable method to individualise and refine the surgical plan in TKA on a per patient basis, incorporating objective information normally only available during the surgery itself. For any figures or tables, please contact authors directly (see Info & Metrics tab above).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 64 - 64
1 Jan 2013
Smith T Shakokani M Cogan A Patel S Toms A Donell S
Full Access

Background. Patellar instability is a complex, multi-factorial disorder. Radiological assessment is regarded as an important part of the management of this population. The purpose of this study was to determine the intra- and inter-rater reliability of common radiological measurements used to evaluate patellar instability. Methods. One hundred and fifty x-rays from 51 individuals were reviewed by five reviewers: two orthopaedic trainees, a radiological trainee, a consultant radiologist and an orthopaedic physiotherapist. Radiological measurements assessed included patellar shape, sulcus angle, congruence angle, lateral patellofemoral angle (LPA), lateral patellar displacement (LPD), lateral displacement measurement (LDM), boss height, and patellar height ratios (Caton-Deschamps, Blackburne-Peel, Insall-Salvati). All assessors were provided with a summary document outlining the method of assessing each measurement. Bland-Altman analyses were adopted to assess intra- and inter-rater reliability. Results. The results indicated generally low measurement error on intra-rater reliability assessment, particularly for LPD (within-subject variance 0.7mm to 3.7mm), LDM (0.7mm to 3.5mm) and boss height (0.4mm to 1.6mm) for all assessors. There was greater measurement error for the calculation of sulcus angle (0.7° to 10.6°), congruence angle (0.8° to 18.4°) and LPA (0.8° to 16.5°). Whilst the inter-rater reliability between assessors indicated a low mean difference for assessments of patellar height measurements (0.0° to 0.6°), there was greater variability for LPA (0.1° to 3.6°), LPD (0.2mm to 4.6mm) and LDM (0.1mm to 4.0mm), with wide 95% limits of agreement for all measurements indicated poor precision. Conclusions. Many of the standard measurements used to assess the patellofemoral joint on plain radiographs have poor precision. Intra-rater reliability may be related to experience but it seems likely that to achieve good inter-rater reliability, specific training may be required to calibrate observers. More formal training in the technique of radiological measurement for those who were inexperienced might have improved the inter-rater reliability


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 69 - 69
1 May 2016
Murphy S Murphy W Kowal J
Full Access

Introduction. Cup malposition in hip arthroplasty and hip resurfacing is associated with instability, accelerated wear, and the need for revision. The current study assesses the validity of intraoperative assessment using a specialized software to analyze intraoperative radiographs. Methods. Cup orientation as measured on intraoperative radiography using the RadLink Galileo Positioning System was assessed in 10 patients. These radiographs were measured by personnel trained to support the system. The results were compared to cup orientation measured by CT. Cup orientation on CT was measured by first identifying the Anterior Pelvic Plane Coordinate system landmarks on a 3D surface model. A multiplanar reconstruction module then allowed for the creation of a plane parallel with the opening plane of the acetabulum. The orientation of the cup opening plane in the AP Plane coordinate space was then calculated. The same definition of cup orientation was used for both methodologies. Results. As compared to direct measurement using CT, the intraoperative radiograph system underestimated anteversion by an average of 8.0 degrees and overestimated cup inclination by 2.9 degrees. The radiographic measurement error in anteversion ranged from −27.4 to +4.0. degrees and for inclination ranged from −2.0 to +5.3 degrees. Conclusion. The use of an intraoperative radiological assessment system is relatively reliable in estimating the inclination of the acetabular component. Anteversion of the acetabular component is extremely poorly assessed by the system


Bone & Joint Research
Vol. 8, Issue 9 | Pages 437 - 437
2 Sep 2019
Pękala PA Henry BM Pękala JR Piska K Tomaszewski KA


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 299 - 299
1 Jul 2011
Ollivere B Darrah C Evans-Gowing R Donell S Wimhurst J Clark I
Full Access

Classification of osteoarthritis of the hip is fraught with difficulty Although different patterns of disease are recognised, there is no accepted classification or grading system. We aim to develop a classification system that reflects both the radiological changes, and the local disease process within the joint. After ethical permission and consent tissue was taken from 20 patients undergoing primary hip replacement surgery. Intra-operative tissue samples were taken from each patient and the steady state gene expression of several cytokines (TNF-α, IL1-β, IFN-γ, IL-6, RANKL and OPG) measured quantitatively using Taqman RT-PCR. Relative expression was calculated for each sample using standard curves and normalised to 18S expression. The technique was consistent with high correlations for repeated measures from the same tissue type (κ=0.99) and from different tissue types in the same joint (κ=0.92). Intra-observer (κ=0.93) and inter-observer (κ=0.89) reliability for the technique were also found to be high. Preoperative radiographs were scored by two independent observers and joint space narrowing, cysts, osteophytes and sclerosis noted in each of the DeLee-Charnley zones on the femoral and acetabular side. Based on these scores patients were then classified to either lytic or sclerotic type and subclassified into either hypertrophic or atrophic. Subgroup analysis of cytokine expression by radiographic type was performed. There were statically significant differences in expression of macrophage stimulating cytokines (IL-1γ and OPG) in the lytic group as compared to the sclerotic group (p< 0.05). Conversely, the sclerotic group expressed significantly higher levels of IL-6. Individuals with atrophic subtype demonstrated significantly higher levels of IL-1β and IL-6, but lower levels of IFN-γ. Our results demonstrate greatly differing patterns of disease within osteoarthritic hip joints. These changes are reflected in radiographic appearances of osteoarthritis. Our proposed classification system can be used grade and classify osteoarthritis in a manner that reflects the disease process