Aims. Electromagnetic induction heating has demonstrated in vitro antibacterial efficacy over biofilms on metallic biomaterials, although no in vivo studies have been published. Assessment of side effects, including
This study evaluates high power low frequency ultrasound transmitted via a flat vibrating probe tip as an alternative technology for meniscal debridement in the knee. A limitation of this technology is thermal damage in residual meniscal tissue. To compare tissue removal rate and thermal damage for a radiofrequency ablation device and an experimental ultrasound ablation device. Twelve bovine meniscal specimens were treated in an identical fashion with (a) a 3.75mm 50° bipolar radiofrequency wand, Arthrocare Super Multivac 50 Arthrowand (Arthrocare Corporation, Sunnyvale, CA), operated in a free-hand manner in accordance with manufacturers instructions (n=6), and (b) an experimental flat-tipped 3mm 20kHz ultrasound probe, suspended vertically in a 500N force-controlled experimental rig (n=6). Tissue removal rate (TRR), zone of
Aim: To determine if bonewax will act as a suitable barrier during cementation of bone cavities after curettage of bone tumours. Method: One mix of methylmethacrylate cement was placed on top of a standard piece of bonewax. A steel thermometer probe was used to measure the temperature of the surface of the cement. The temperature was measured above and below the bonewax. Results: The surface temperature of the cement was found to be 57°C both above and below the bonewax. The exothermic reaction occurred after the end of the cement working time, thus the bonewax acted as a physical barrier to protrusion of cement before melting away. Discussion: Bone tumours such as GCT may cause cortical destruction. Standard treatment for many such benign tumours is curettage and cementation. 1. This is simplest when there is no cortical defect, other than the cortical window which is created by the surgeon who then curettes the tumour and performs any adjuvant therapy that is indicated. The cavity is then filled with cement, which is applied while still workable and runny to allow complete fill of the cavity. Pressurisation is the norm to interdigitate cement into bone to produce
Introduction. Hip resurfacing arthroplasty has gained popularity as an alternative for total hip arthroplasty. Usually, cemented fixation is used for the femoral component. However, each type of resurfacing design has its own recommended cementing technique. In a recent investigation the effect of various cementing techniques on cement mantle properties was studied. This study showed distinct differences in cement mantle volume, filling index and morphology. In this study, we investigated the effect of these cement mantle variations on the heat generation during polymerization, and its consequences in terms of
The heat produced by drills, saws and PMMA cement in the handling of bone can cause
Resurfacing hip arthroplasty is a successful option for the treatment of the young and active patient with hip arthritis. However, it is complicated by femoral neck fracture and avascular necrosis, which result from devascularisation during surgery. Devascularisation maybe caused by
Introduction: Resurfacing hip arthroplasty is a successful option for the treatment of the young and active patient with hip arthritis. However, it is complicated by femoral neck fracture and avascular necrosis, which may result from devascularisation during surgery. Devascularisation maybe caused by
To assess the potential for IDET to ablate nerve fibres in an experimentally induced peripheral annular lesion. Intradiscal electrothermal therapy (IDET) is being increasingly used as a minimally-invasive treatment for discogenic low back pain, with success reported in up to 70% of cases. One proposed mechanism of IDET is ablation reported in up to 70% of cases. One proposed mechanism of IDET is ablation of nerve fibres in the peripheral annulus. An ovine model was used to assess the innervation of peripheral annular lesions and the potential for IDET to denervate this region of the disc. Postero-lateral annular incisions were made in 32 lumbar discs of 16 sheep. At twelve weeks the sheep underwent IDET at one level and a sham treatment at the other level. IDET was performed using a modified Intradiscal Catheter (SpineCath, Oratec Interventions Inc., Menlo Park, CA). The spines were harvested at intervals up to six months. Histological sections of the discs were stained with H&
E and an antibody to the general neuronal marker PGP 9.5. Vascular granulation tissue consistent with a healing posterior annular tear was observed in all incised discs from 12 weeks, extending to an average depth of 850 μm at 0 weeks to 690 μm at 6 months. PGP 9.5 positive nerve fibres were clearly identified outside the discs but were scarce within the discs. Nerves were identified up to 300 μm inside the annulus, from the earliest time point, and there was a trend towards less innervation with time. There were no fewer nerve fibres identified in those specimens that had undergone IDET. Specimens obtained six weeks after IDET showed evidence of
3-D finite element model of a resurfaced femoral head was composed. Five configurations of cement layer were analyzed and the transient heat transfer analysis during cement polymerization was performed. Peak temperature at the bone-cement interface temperature was lower than 40 oC when there was no or 1.5 mm cement penetration but reached 54 oC and 74 oC with 6 mm penetration and 6 mm penetration plus a cement –filled cyst of 1 cm3, respectively. With deep cement penetration, and a large cement-filled cyst, the peak temperatures exceeded bone thermal osteonecrosis at 55 oC. To evaluate using a finite element analysis model, the possibility of bone
Introduction: Intradiscal electrothermal therapy (IDET) is being used increasingly as a minimally-invasive treatment for chronic discogenic low back pain, with success reported in up to 70% of cases. The mechanism of action however is poorly understood. Proposed mechanisms include the contraction of collagen and the coagulation of annular nociceptors. An ovine model was used to assess the innervation of peripheral posterolateral annular lesions and the potential for IDET to denervate this region. Methods: Posterolateral annular incisions were made in 36 lumbar discs of 18 sheep. After twelve weeks the sheep underwent IDET at one level and a sham treatment at the other level. IDET was performed using a modified intradiscal catheter (SpineCATH™, Oratec Interventions Inc., Menlo Park, CA). Temperatures were recorded in the nucleus and the posterior annulus. The spines were harvested at intervals of up to eighteen months. Histological sections of the discs were stained with haematoxylin and eosin and an antibody to the general neuronal marker PGP 9.5. Results: The target temperature of 90°C at the catheter tip was reached in all cases. The mean maximum T. Pa. was 63.6°C and the mean maximum TN was 67.8°C. Vascular granulation tissue consistent with a healing response was observed in the region of the posterior annulus tear of all incised discs from 12 weeks. PGP 9.5 positive nerve fibres were clearly identified in the adjacent periannular tissue, but were scarce within the outer few lamellae of the annulus. There were no fewer nerve fibres identified in those specimens that had undergone IDET. From six weeks after IDET there was evidence of
INTRODUCTION: Intradiscal electrothermal therapy (IDET) is being used increasingly as a minimally-invasive treatment for chronic discogenic low back pain, with success reported in up to 70% of cases. The mechanism of action however is poorly understood. Proposed mechanisms include the contraction of collagen and the coagulation of annular nociceptors. An ovine model was used to assess the innervation of peripheral posterolateral annular lesions and the potential for IDET to denervate this region. METHODS: Posterolateral annular incisions were made in 36 lumbar discs of 18 sheep. After twelve weeks the sheep underwent IDET at one level and a sham treatment at the other level. IDET was performed using a modified intradiscal catheter (SpineCATH. TM. , Oratec Interventions Inc., Menlo Park, CA). Temperatures were recorded in the nucleus and the posterior annulus. The spines were harvested at intervals of up to eighteen months. Histological sections of the discs were stained with haematoxylin and eosin and an antibody to the general neuronal marker PGP 9.5. RESULTS: The target temperature of 90°C at the catheter tip was reached in all cases. The mean maximum T. Pa. was 63.6°C and the mean maximum T. N. was 67.8°C. Vascular granulation tissue consistent with a healing response was observed in the region of the posterior annulus tear of all incised discs from 12 weeks. PGP 9.5 positive nerve fibres were clearly identified in the adjacent periannular tissue, but were scarce within the outer few lamellae of the annulus. There were no fewer nerve fibres identified in those specimens that had undergone IDET. From six weeks after IDET there was evidence of
Objective: To investigate the effects of intra-discal electro-thermal therapy (IDET) on an experimentally induced posterolateral annular inter vertebral disclesion in sheep. Summary of Background Data: IDET is being used increasingly as a minimally-invasive treatment for chronic discogenic low back pain, with success reported in up to 70% of cases. The mechanism of action however is poorly understood. Proposed mechanisms include the contraction of collagen and the coagulation of annular nociceptors. An ovine model was used to assess the innervation of peripheral posterolateral annular lesions and the potential for IDET to denervate this region. Methods: Posterolateral annular incisions were made in 36 lumbar discs of 18 sheep. After twelve weeks the sheep underwent IDET at one level and a sham treatment at the other level. IDET was performed using a modified intradiscal catheter (SpineCATH™, Oratec Interventions Inc., Menlo Park, CA). Temperatures were recorded in the nucleus (T. N. ) and the posterior annulus (T. Pa. ). The spines were harvested at intervals up to eighteen months. Histological sections of the discs were stained with haematoxylin and eosin and an antibody to the general neuronal marker PGP 9.5. Results: The target temperature of 90°C at the catheter was tip was reached in all cases. The mean maximum T. Pa. was 63.6°C and the mean maximum T. N. 67.8°C. Vascular granulation tissue consistent with a healing response was observed in the region of the posterior annulus tear of all incised discs from 12 weeks. PGP 9.5 positive nerve fibres were clearly identified in the adjacent periannular tissue, but were scarce within the outer few lamellae of the annulus. There were no fewer nerve fibres identified in those specimens that had undergone IDET. From six weeks after IDET there was evidence of
Total knee arthroplasty is an excellent operation and the results have been well documented for both cemented and cementless techniques. It is generally accepted that the results for cemented total knee outpace the results for cementless total knees. Despite this there remains great interest in developing systems and techniques that might allow predictable biologic fixation for knee arthroplasty. There is a long list of requirements that must be met to predictably allow bone ingrowth. These include viable bone, optimal pore size, optimal pore depth, optimal porosity, minimal gaps between bone and implant and minimal micromotion. Implant design is critical but it is proposed that operative techniques can help with some of these issues. We will discuss these operative issues during the surgical demo. These technique issues include: replication of normal posterior slope of the tibia, irrigation of all cuts to avoid
Objectives: Posterolateral annular lesions were experimentally induced and allowed to mature for 12 weeks in the intervertebral discs of sheep. IDET was performed in an attempt to denervate and repair the annular lesion. The histological and immunohistochemical effects of IDET were studied. Summary of Background Data: IDET continues to be used as a minimally-invasive treatment for chronic discogenic low back pain, with success rates reported in up to 70% of cases. The mechanism of action by which IDET exerts its effect is poorly understood. Proposed mechanisms include the contraction of collagen and the coagulation of annular nociceptors. An ovine model was used firstly to induce a posterolateral annular lesion, secondly to assess the innervation of such a lesion, and thirdly to assess the effect of IDET on this innervation. Methods: Posterolateral annular incisions were made in 40 lumbar discs of 20 sheep. Twelve weeks were allowed for each annular lesion to mature. IDET was then performed in the disc with the posterolateral annular tear and in another control level. IDET was performed using a modified intradiscal catheter. Temperatures were recorded in the nucleus (T. N. ) and the posterior annulus (T. PA. ). The spines were harvested at predetermined intervals up to eighteen months. Histological sections of the discs were graded for disc morphology to assess degeneration and immunohistochemical staining to assess potential denervation. Results: Vascular granulation tissue consistent with a healing response was observed in the posterior annular tear of all incised discs from 12 weeks. PGP 9.5 positive nerve fibres were clearly identified in the adjacent periannular tissue and the outer few lamellae of the posterior annulus. During the IDET procedure the mean maximaximum T. PA. was 63.6°C and the mean maximaximum T. N. was 67.8°C. At sacrifice the number of nerve fibres identified in the posterior annular tear was the same for those specimens that had undergone IDET and those that had not. From six weeks after IDET there was evidence of
Thermal osteonecrosis is a side effect when used Kirschner (K) wires and drills in orthopaedic surgeries. This osteonecrosis may endanger the fixation. Orthopaedic surgeons sometimes have to use unsharpened K-wires in emergent surgery. The thermal effect of used and unsharpened K wire is ambiguous to the bone. This experimental study aims to assess the thermal osteonecrosis while drilling bone with three different types of K-wires especially a previously used unsharpened wire and its thermographic measurements correlation. Two different speeds of rotation were chosen to investigate the effect of speed on
INTRODUCTION.
Introduction: A major concern with cemented hip resurfacing arthroplasty (HRA) femoral components is the thermal damage to femoral head during cement curing; this maybe linked to fracture (reported incidence ~2%) and early failure. We investigated the effect of a modifid surgical technique using pulse lavage, lesser trochanter suction and early reduction on the maximum temperature recorded in the femoral head during HRA, compared to manual lavage and reduction after cement curing. Methods: Patients undergoing total hip replacement (THR) were given a dummy HRA procedure, during which a temperature probe was inserted into the femoral head and the measuring tip placed close to the reamed surface; the position of the probe was confirmed by inter-operative xray. Four subjects received a dummy HRA femoral component using manual lavage and Simplex cement. The implanted femur was kept dislocated until the cement cured. The implanted heads were then removed and sectioned to locate the temperature probes, the THR surgery was then performed. Five patients receiving a definitive HRA were also measured; for these subjects suction on the lesser trochanter was used, pulse lavage given for 30 seconds prior to cementing with Simplex, and pulse lavage of the femoral head for 2 minutes, applied 1 minute after cementing the femoral component. The implanted joint was then immediately reduced and a further two minutes of pulse lavage applied to the reduced joint. Temperatures were recorded until the cement finally cured. In every case the cement was hand mixed for 1 minute and the component implanted at 2 minutes 30 seconds after mixing began. Results: Sectioning showed that probe tips were <
0.5mm from cement mantle. The maximum temperature recorded in the femoral head was significantly (p=0.014) greater for the manual technique, median value of 47.2°C (37.0 to 67.9°C), than for the pulse lavage technique, median value of 32.7°C (31.7 to 35.6°C). Discussion: The results show that excessive bone temperatures can occur during hip resurfacing. Temperatures above 45°C kill bone cells, the manual technique may lead to substantial
This case presentation highlights the problem of
Introduction: Radiolucent lines (RLL) underneath the tibial component are common findings following the Oxford Uni-compartmental Knee Arthroplasty (OUKA)[. 1. ]. Many theories have been proposed to explain the cause of RLL, such as poor cementing, osteonecrosis, micromotion, and
Computer-assisted navigation during total knee replacement has been advocated to improve component alignment and hence reduce failure rates and improve quality of life. The technique involves the placement of trackers via pins placed in both the femur and tibia throughout the surgery. It has been proposed that complication rates are higher in knee arthroplasty when computer navigation is used, compared to when it is not, due to increased risks from the pin tracker sites. Potential risks from pin sites include infection, fractures of the tibia or femur and pin site pain. In this study we present the post-operative complication rates related to pin tracker sites of computer navigated knee arthroplasty from a single surgeon at one centre. A database was compiled including all patients undergoing knee arthroplasty with computer navigation between January 2009 and December 2013 performed by a single surgeon at one centre. A retrospective study was undertaken having identified a total of 321 patients (642 pin sites) with 287 having undergone total knee replacement, 29 Uni-condylar knee replacement and five having undergone patellofemoral knee replacement. There 131 males and 190 females with a mean age of 69.4 [range 48–89]. There were no exclusions. The patient's notes were reviewed for any complications that occurred as a result of pin sites including infection, pin site pain and fracture. Only one patient (0.03%) was identified with a superficial pin site infection that was successfully managed with oral antibiotics only. There were no fractures or other complications identified in any of the other patients. In this series, the complication rates resulting from pin tracker sites was very low suggesting computer navigation does not increase the risks of knee arthroplasty. There were no cases of femoral or tibial fractures in this series, as have previously been reported. It is therefore likely that the technique of pin site placement is important in limiting the risk of complications. In this series a standard technique was used in all cases. Stab incisions are always used rather than a percutaneous technique and the wounds closed with clips and protected with dressings at the end of the surgery. Uni-cortical drilling is sufficient to provide stability of the trackers intra-operatively and minimises the risk of