Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 114 - 114
1 Dec 2020
Cullu E Olgun H Tataroğlu C Ozgezmez FT Sarıerler M
Full Access

Thermal osteonecrosis is a side effect when used Kirschner (K) wires and drills in orthopaedic surgeries. This osteonecrosis may endanger the fixation. Orthopaedic surgeons sometimes have to use unsharpened K-wires in emergent surgery. The thermal effect of used and unsharpened K wire is ambiguous to the bone. This experimental study aims to assess the thermal osteonecrosis while drilling bone with three different types of K-wires especially a previously used unsharpened wire and its thermographic measurements correlation. Two different speeds of rotation were chosen to investigate the effect of speed on thermal necrosis to the bone. A total of 16 New Zealand white rabbits weighing a mean of 2.90 kg (2.70 – 3.30 kg) were used. All rabbits were operated under general anaesthesia in a sterile operating room. Firstly, 4 cm longitudinal lateral approach was used to the right femur and then the femur was drilled with 1.0 mm trochar tip, spade tip and previously used unsharpened K-wires and 1.0 mm drill bit at 1450 rpm speed. Left femur was drilled with same three type K-wires and drill bit at 330 rpm speed. One cm distance was left among four penetrations on the femur. The thermal changes were recorded by Flir® E6 Thermal Camera from 50 cm distance and 30-degree angle. Thermographic measurements saved for every drilling process and recorded for the highest temperature (°C) during the drilling. All subjects were sacrificed post-operatively on the eighth day and specimens were prepared for the histological examination. The results of osteonecrosis assessment score and thermographic correlation were evaluated statistically. Histological specimens were evaluated by the scoring of osteonecrosis, osteoblastic activity, haemorrhage, microfracture and inflammation. Results were graded semi-quantitatively as none, moderate or severe for osteonecrosis, haemorrhage and inflammation. The microfracture and osteoblastic activity were evaluated as present or absent. There was no meaningful correlation between osteonecrosis and the drilling speed (p=0.108). There was less microfracture zone which was drilled with trochar tip K-wires at 1450 rpm speed (p=0.017). And the drilling temperature of trochar tip K-wires was higher than the others(p=0.001). Despite this evaluation, osteonecrosis zone of spade and unsharpened tip K-wires were more than trochar tip K-wires (p=0.039). The drill bit at 330 rpm caused the least osteonecrosis and haemorrhage and respectfully the lowest drilling temperature (p=0,001). The osteoblastic activity shows no difference between the groups. (p=0,122; 0,636;0.289). On the contrary to the literature, our experiment showed that there is no meaningful correlation between osteonecrosis score and temperature produced by drilling. The histological assessment showed the osteonecrosis during short drilling time but, not clarify the relation with drilling temperature. Eventually, the osteonecrosis showed a positive correlation with drilling time independently of drilling temperature at 330 rpm. (p=0,042) These results show that we need more studies to understand about osteonecrosis and its relationship with drilling heat temperature. Trochar tip K-wires creates higher drilling temperature but less osteonecrosis than a spade and unsharpened cut tip K-wires. Using unsharpened tip K-wire causes more osteonecrosis. Previously used and, unsharpened K-wires should be discarded


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 97 - 97
1 Mar 2008
Beaulé P Lu Z Luck J Campbell P
Full Access

3-D finite element model of a resurfaced femoral head was composed. Five configurations of cement layer were analyzed and the transient heat transfer analysis during cement polymerization was performed. Peak temperature at the bone-cement interface temperature was lower than 40 oC when there was no or 1.5 mm cement penetration but reached 54 oC and 74 oC with 6 mm penetration and 6 mm penetration plus a cement –filled cyst of 1 cm3, respectively. With deep cement penetration, and a large cement-filled cyst, the peak temperatures exceeded bone thermal osteonecrosis at 55 oC. To evaluate using a finite element analysis model, the possibility of bone thermal necrosis secondary to cement in resurfacing arthroplasty of the hip. With deep cement penetration, and the presence of a large cement-filled cyst, the peak temperatures were in the range of bone thermal osteonecrosis 55 oC. Cementing technique in resurfacing arthroplasty should strive to strike a balance between fixation and avoiding bone thermal necrosis by excessive cement penetration. This information could explain why femoral head cysts > 1cm are a risk factor for femoral loosening after resurfacing arthroplasty and excessive cement penetration could lead to femoral neck fracture. 3-D finite element model of a hemispherical resurfaced femoral head was composed of a metal shell with a diameter of 46 mm. Five configurations of cement layer were analyzed a) no penetration into the bone, b) 1.5 mm penetration, c) 6 mm penetration, d) 6 mm penetration and a 1 cm3 cement filled cyst, and e) 6 mm penetration and 2 cm3 cement-filled cyst. The transient heat transfer analysis during cement polymerization was performed in a series of time steps. The temperature within the bone and cement was lower than 40 oC when there was no or 1.5 mm cement penetration into the femoral head. In contrast, the peak temperature at the bone-cement interface reached 54 oC and 74 oC and 63 oC with 6 mm penetration and 6 mm penetration plus a cement –filled cyst of 1 cm3, respectively


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 17 - 17
1 May 2015
Mathews J Whitehouse M Baker R
Full Access

Cement-induced thermal osteonecrosis is well documented, as is the potential for nerve injury from thermal energy. Cement is often used to augment fixation following excision of humeral metastases. Porcine femurs were used as a model. We sought to find out the maximum temperatures that would be reached in various parts of the bone during the cement setting process, to explore what negative effects this might have on neighbouring bone and nerve. A 12mm by 12mm window was cut from 12 porcine femoral shafts, and Palacos R+D cement injected into the defect. As cement set, bone surface temperature was measured using infra-red thermal imaging and thermocouples used to measure temperatures at the bone-cement interface, 5mm from the cement bolus, 10mm from cement bolus and an area running around the shaft replicating radial nerve. Bone surface temperature rose to a maximum of 34.0 C (on average), and 32.9 C in the ‘radial nerve’ thermocouple. Notably, in two bones there were fractures during specimen preparation, and maximum temperatures in these two areas exceeded 41 degrees C. Average maximum temperatures were 58.1 C, 36.5 C and 30.1 C at the bone cement interface, 5mm and 10mm from the cement bolus respectively


Bone & Joint 360
Vol. 1, Issue 5 | Pages 10 - 12
1 Oct 2012

The October 2012 Hip & Pelvis Roundup360 looks at: diagnosing the infected hip replacement; whether tranexamic acid has a low complication rate; the relationship between poor cementing technique and early failure of resurfacing; debridement and retention for the infected replacement; triple-tapered stems and bone mineral density; how early discharge can be bad for your sleep; an updated QFracture algorithm to predict the risk of an osteoporotic fracture; and local infiltration analgesia and total hip replacement.