Advertisement for orthosearch.org.uk
Results 1 - 20 of 3082
Results per page:
Bone & Joint Research
Vol. 11, Issue 4 | Pages 239 - 250
20 Apr 2022
Stewart CC O’Hara NN Bzovsky S Bahney CS Sprague S Slobogean GP

Aims

Bone turnover markers (BTMs) follow distinct trends after fractures and limited evidence suggests differential levels in BTMs in patients with delayed healing. The effect of vitamin D, and other factors that influence BTMs and fracture healing, is important to elucidate the use of BTMs as surrogates of fracture healing. We sought to determine whether BTMs can be used as early markers of delayed fracture healing, and the effect of vitamin D on BTM response after fracture.

Methods

A total of 102 participants aged 18 to 50 years (median 28 years (interquartile range 23 to 35)), receiving an intramedullary nail for a tibial or femoral shaft fracture, were enrolled in a randomized controlled trial comparing vitamin D3 supplementation to placebo. Serum C-terminal telopeptide of type I collagen (CTX; bone resorption marker) and N-terminal propeptide of type I procollagen (P1NP; bone formation marker) were measured at baseline, six weeks, and 12 weeks post-injury. Clinical and radiological fracture healing was assessed at three months.


Aims

The tibial component of total knee arthroplasty can either be an all-polyethylene (AP) implant or a metal-backed (MB) implant. This study aims to compare the five-year functional outcomes of AP tibial components to MB components in patients aged over 70 years. Secondary aims are to compare quality of life, implant survivorship, and cost-effectiveness.

Methods

A group of 130 patients who had received an AP tibial component were matched for demographic factors of age, BMI, American Society of Anesthesiologists (ASA) grade, sex, and preoperative Knee Society Score (KSS) to create a comparison group of 130 patients who received a MB tibial component. Functional outcome was assessed prospectively by KSS, quality of life by 12-Item Short-Form Health Survey questionnaire (SF-12), and range of motion (ROM), and implant survivorships were compared. The SF six-dimension (6D) was used to calculate the incremental cost effectiveness ratio (ICER) for AP compared to MB tibial components using quality-adjusted life year methodology.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 105 - 105
1 May 2011
Erdem M Sen C Gunes T Bostan B Sahin SA Balta O
Full Access

Introduction: Treatment of defected pseudoarthrosis tibia remains controversial due to bone loss with/without infection arises from previous interventions. In the present study we evaluated the results of acute shortening and distraction osteogenesis in the treatment of tibia pseudoarthrosis with bone loss. Material and Methods: Eleven patients were treated with acute shortening and distraction osteogenesis. Mean age and bone loss was 27.5 years (range 10–44) and 8.9 cm (range 3.5–12) respectively. 7 of eleven patients is infected pseudoarthrosis. Enfected patients were type 4A according to Chierny-Mader classification. The 4 of infected patients were treated with two staged procedure. In the first stage antibiotic (teicoplanin) impregnated polymethylmetacrilate beads were placed to the space occurred as a result of excision of sclerotic bone segment and fixation was performed by external fixator or braces. Second stage composed of acute compression (shortening) and distraction osteogenesis. Other 3 infected and noninfected patients were treated with resection, acute shortening and distraction osteogenesis in one stage. In six cases docking site were grafted with autografts. Defects greater than 4 cm were gradually shortened 2mm/day in addition to acute shortening. Limb length inequality was solved with lengthening from proximal tibial corticotomy and achieving union of both sites about the same time. Results: Mean follow up, external fixator time and external fixator index was 48.3 months (21–80), 8.9 months (6–13) and 1,3 month/cm respectively. results were evaluated according to Paley’s bone and functional evaluation scoring. Eleven patient revealed excellent results with regard to bone evaluation and 10 patient revealed excellent and 1 patient revealed good results in terms of functional evaluation. In one patient fracture at the pseudoartrosis site occurred due to new trauma after removal of the fixator which was treated with circular external fixator. In the another patient, the lengthening regenerate side was low quality bone which need intra-medullary fixation and grafted with autograft. Conclusion: Acute shortening and distraction osteogenesis is a safe and successful procedure in the treatment of defected tibia pseudoarthrosis and is alternative to other treatments. Acute shortening and distraction osteogenesis was found to be successful and safe with regard to functional results in the treatment of defected tibia pseudoarthrosis. Besides we suggest it as an alternative due to lower rate of complications and less external fix-ator time compared to other Methods:


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 5 - 5
7 Nov 2023
Ncana W
Full Access

Open tibia fractures are common injuries in our paediatric population and are often associated with high-energy trauma such as pedestrian-vehicle accidents. At our institution, these injuries are routinely treated with debridement and mono-lateral external fixation. The purpose of this study was to determine the outcome of open tibia fractures treated according to this protocol, as well as the complication rate and factors contributing to the development of complications. We performed a retrospective folder review of all patients with open tibia fractures that were treated according to our protocol from 2015–2019. Patients treated by other means, who received primary treatment elsewhere, and with insufficient data, were excluded. Data was collected on presenting demographics, injury characteristics, management, and clinical course. Complications were defined as pin tract infections, delayed- or non-union, malunion, growth arrest, and neurovascular injury. Appropriate statistical analysis was performed. One-hundred-and-fifteen fractures in 114 children (82 males) with a median age of 7 years (IQR 6–9) were included in the analysis. Pedestrian vehicle accidents (PVA's) accounted for 101 (88%) of fractures, and the tibial diaphysis was affected in 74 cases (64%). Fracture severity was equally distributed among the Gustillo-Anderson grades. The median Abbreviated Injury Score was 4 (IQR 4;5). Ninety-five fractures (83%) progressed to uneventful union within 7 weeks. Twenty patients (17%) developed complications, with delayed union and fracture site infections being the most common complications. Gustillo-Anderson Grade 3 fractures, an increased Abbreviated Injury Score, and the need for advanced wound closure techniques were risk factors for developing complications. Surgical debridement and external fixation in a simple mono-lateral frame is an effective treatment for open tibia fractures in children and good outcomes were seen in 83% of patients. More severe injuries requiring advanced wound closure were associated with the development of complications


Bone & Joint Research
Vol. 11, Issue 2 | Pages 91 - 101
1 Feb 2022
Munford MJ Stoddart JC Liddle AD Cobb JP Jeffers JRT

Aims. Unicompartmental and total knee arthroplasty (UKA and TKA) are successful treatments for osteoarthritis, but the solid metal implants disrupt the natural distribution of stress and strain which can lead to bone loss over time. This generates problems if the implant needs to be revised. This study investigates whether titanium lattice UKA and TKA implants can maintain natural load transfer in the proximal tibia. Methods. In a cadaveric model, UKA and TKA procedures were performed on eight fresh-frozen knee specimens, using conventional (solid) and titanium lattice tibial implants. Stress at the bone-implant interfaces were measured and compared to the native knee. Results. Titanium lattice implants were able to restore the mechanical environment of the native tibia for both UKA and TKA designs. Maximum stress at the bone-implant interface ranged from 1.2 MPa to 3.3 MPa compared with 1.3 MPa to 2.7 MPa for the native tibia. The conventional solid UKA and TKA implants reduced the maximum stress in the bone by a factor of 10 and caused > 70% of bone surface area to be underloaded compared to the native tibia. Conclusion. Titanium lattice implants maintained the natural mechanical loading in the proximal tibia after UKA and TKA, but conventional solid implants did not. This is an exciting first step towards implants that maintain bone health, but such implants also have to meet fatigue and micromotion criteria to be clinically viable. Cite this article: Bone Joint Res 2022;11(2):91–101


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 795 - 800
1 Jul 2023
Parsons N Achten J Costa ML

Aims. To report the outcomes of patients with a fracture of the distal tibia who were treated with intramedullary nail versus locking plate in the five years after participating in the Fixation of Distal Tibia fracture (FixDT) trial. Methods. The FixDT trial reported the results for 321 patients randomized to nail or locking plate fixation in the first 12 months after their injury. In this follow-up study, we report the results of 170 of the original participants who agreed to be followed up until five years. Participants reported their Disability Rating Index (DRI) and health-related quality of life (EuroQol five-dimension three-level questionnaire) annually by self-reported questionnaire. Further surgical interventions related to the fracture were also recorded. Results. There was no evidence of a difference in patient-reported disability, health-related quality of life, or the need for further surgery between participants treated with either type of fixation at five years. Considering the combined results for all participants, there was no significant change in DRI scores after the first 12 months of follow-up (difference between 12 and 24 months, 3.3 (95% confidence interval -1.8 to 8.5); p = 0.203), with patients reporting around 20% disability at five years. Conclusion. This study shows that the moderate levels of disability and reduced quality of life reported by participants 12 months after a fracture of the distal tibia persist in the medium term, with little evidence of improvement after the first year. Cite this article: Bone Joint J 2023;105-B(7):795–800


Bone & Joint Open
Vol. 5, Issue 7 | Pages 592 - 600
18 Jul 2024
Faschingbauer M Hambrecht J Schwer J Martin JR Reichel H Seitz A

Aims. Patient dissatisfaction is not uncommon following primary total knee arthroplasty. One proposed method to alleviate this is by improving knee kinematics. Therefore, we aimed to answer the following research question: are there significant differences in knee kinematics based on the design of the tibial insert (cruciate-retaining (CR), ultra-congruent (UC), or medial congruent (MC))?. Methods. Overall, 15 cadaveric knee joints were examined with a CR implant with three different tibial inserts (CR, UC, and MC) using an established knee joint simulator. The effects on coronal alignment, medial and lateral femoral roll back, femorotibial rotation, bony rotations (femur, tibia, and patella), and patellofemoral length ratios were determined. Results. No statistically significant differences were found regarding coronal alignment (p = 0.087 to p = 0.832). The medial congruent insert demonstrated restricted femoral roll back (mean medial 37.57 mm; lateral 36.34 mm), while the CR insert demonstrated the greatest roll back (medial 42.21 mm; lateral 37.88 mm; p < 0.001, respectively). Femorotibial rotation was greatest with the CR insert with 2.45° (SD 4.75°), then the UC insert with 1.31° (SD 4.15°; p < 0.001), and lowest with the medial congruent insert with 0.8° (SD 4.24°; p < 0.001). The most pronounced patella shift, but lowest patellar rotation, was noted with the CR insert. Conclusion. The MC insert demonstrated the highest level of constraint of these inserts. Femoral roll back, femorotibial rotation, and single bony rotations were lowest with the MC insert. The patella showed less shifting with the MC insert, but there was significantly increased rotation. While the medial congruent insert was found to have highest constraint, it remains uncertain if this implant recreates native knee kinematics or if this will result in improved patient satisfaction. Cite this article: Bone Jt Open 2024;5(7):592–600


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 3 - 3
1 Apr 2022
Bari M
Full Access

Introduction. Infected big gap non-union of femur and tibia are difficult to treatment because of infection, bone loss, shortening, poor sift tissue over and deformity. Step by step management and definitive treatment by Ilizarov fixator was achieved in our cases. Materials and Methods. A long defect which is more than 10cm in femur and tibia because of infection and gap, tumor resection, traumatic loss, which is very difficult to treat by conventional method and that's why we treated that type defect by Tibialization of fibula with Ilizarov technique. Management of infected big gap non-union of the femur include debridement and bone transport by Ilizarov technique by using Ilizarov fixator we can correct deformities, regenerate new bone without bone grafting, correct LLD and patient can weight bear during the course of treatment. We retrospectively reviewed records of 246 consecutive patients who underwent distraction osteogenesis using Ilizarov compression-distraction device for infected big gap INU of femur and tibia from 2000 to 2020. Results. All healed with the application of Ilizarov fixator, 5 needed reapplications of Ilizarov to achieve 100% union. 210 were excellent, 25 good and 6 were fair by ASAMI criteria. Mean Ilizarov duration was 366 days (130–250). Mean 8.2 cm length was achieved in the regenerate. Conclusions. A well plan step by step Ilizarov technique to cover infected gap non-union of femur and tibia is an excellent method in challenging cases. Excellent results cannot be achieved with conventional methods but can be easily achieved with Ilizarov technique within 1–2 years


Bone & Joint Open
Vol. 4, Issue 3 | Pages 188 - 197
15 Mar 2023
Pearson NA Tutton E Gwilym SE Joeris A Grant R Keene DJ Haywood KL

Aims. To systematically review qualitative studies of patients with distal tibia or ankle fracture, and explore their experience of injury and recovery. Methods. We undertook a systematic review of qualitative studies. Five databases were searched from inception to 1 February 2022. All titles and abstracts were screened, and a subset were independently assessed. Methodological quality was appraised using the Critical Appraisal Skills Programme (CASP) checklist. The GRADE-CERQual checklist was used to assign confidence ratings. Thematic synthesis was used to analyze data with the identification of codes which were drawn together to form subthemes and then themes. Results. From 2,682 records, 15 studies were reviewed in full and four included in the review. A total of 72 patients were included across the four studies (47 female; mean age 50 years (17 to 80)). Methodological quality was high for all studies, and the GRADE-CERQual checklist provided confidence that the findings were an adequate representation of patient experience of distal tibia or ankle fracture. A central concept of ‘being the same but different’ conveyed the substantial disruption to patients’ self-identity caused by their injury. Patient experience of ‘being the same but different’ was expressed through three interrelated themes, with seven subthemes: i) being proactive where persistence, doing things differently and keeping busy prevailed; ii) living with change including symptoms, and living differently due to challenges at work and leisure; and iii) striving for normality, adapting while lacking in confidence, and feeling fearful and concerned about the future. Conclusion. Ankle injuries were disruptive, draining, and impacted on patients’ wellbeing. Substantial short- and longer-term challenges were experienced during recovery. Rehabilitation and psychosocial treatment strategies may help to ameliorate these challenges. Patients may benefit from clinicians being cognisant of patient experience when assessing, treating, and discussing expectations and outcomes with patients. Cite this article: Bone Jt Open 2023;4(3):188–197


Bone & Joint Research
Vol. 11, Issue 5 | Pages 252 - 259
1 May 2022
Cho BW Kang K Kwon HM Lee W Yang IH Nam JH Koh Y Park KK

Aims. This study aimed to identify the effect of anatomical tibial component (ATC) design on load distribution in the periprosthetic tibial bone of Koreans using finite element analysis (FEA). Methods. 3D finite element models of 30 tibiae in Korean women were created. A symmetric tibial component (STC, NexGen LPS-Flex) and an ATC (Persona) were used in surgical simulation. We compared the FEA measurements (von Mises stress and principal strains) around the stem tip and in the medial half of the proximal tibial bone, as well as the distance from the distal stem tip to the shortest anteromedial cortical bone. Correlations between this distance and FEA measurements were then analyzed. Results. The distance from the distal stem tip to the shortest cortical bone showed no statistically significant difference between implants. However, the peak von Mises stress around the distal stem tip was higher with STC than with ATC. In the medial half of the proximal tibial bone: 1) the mean von Mises stress, maximum principal strain, and minimum principal strain were higher with ATC; 2) ATC showed a positive correlation between the distance and mean von Mises stress; 3) ATC showed a negative correlation between the distance and mean minimum principal strain; and 4) STC showed no correlation between the distance and mean measurements. Conclusion. Implant design affects the load distribution on the periprosthetic tibial bone, and ATC can be more advantageous in preventing stress-shielding than STC. However, under certain circumstances with short distances, the advantage of ATC may be offset. Cite this article: Bone Joint Res 2022;11(5):252–259


Bone & Joint Research
Vol. 11, Issue 5 | Pages 304 - 316
17 May 2022
Kim MH Choi LY Chung JY Kim E Yang WM

Aims. The association of auraptene (AUR), a 7-geranyloxycoumarin, on osteoporosis and its potential pathway was predicted by network pharmacology and confirmed in experimental osteoporotic mice. Methods. The network of AUR was constructed and a potential pathway predicted by Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway and Gene Ontology (GO) terms enrichment. Female ovariectomized (OVX) Institute of Cancer Research mice were intraperitoneally injected with 0.01, 0.1, and 1 mM AUR for four weeks. The bone mineral density (BMD) level was measured by dual-energy X-ray absorptiometry. The bone microstructure was determined by histomorphological changes in the femora. In addition, biochemical analysis of the serum and assessment of the messenger RNA (mRNA) levels of osteoclastic markers were performed. Results. In total, 65.93% of the genes of the AUR network matched with osteoporosis-related genes. Osteoclast differentiation was predicted to be a potential pathway of AUR in osteoporosis. Based on the network pharmacology, the BMD and bone mineral content levels were significantly (p < 0.05) increased in the whole body, femur, tibia, and lumbar spine by AUR. AUR normalized the bone microstructure and the serum alkaline phosphatase (ALP), bone-specific alkaline phosphatase (bALP), osteocalcin, and calcium in comparison with the OVX group. In addition, AUR treatment reduced TRAP-positive osteoclasts and receptor activator of nuclear factor kappa-B ligand (RANKL). +. nuclear factor of activated T cells 1 (NFATc1). +. expression in the femoral body. Moreover, the expressions of initiators for osteoclastic resorption and bone matrix degradation were significantly (p < 0.05) regulated by AUR in the lumbar spine of the osteoporotic mice. Conclusion. AUR ameliorated bone loss by downregulating the RANKL/NFATc1 pathway, resulting in improvement of osteoporosis. In conclusion, AUR might be an ameliorative cure that alleviates bone loss in osteoporosis via inhibition of osteoclastic activity. Cite this article: Bone Joint Res 2022;11(5):304–316


Bone & Joint Research
Vol. 11, Issue 4 | Pages 229 - 238
11 Apr 2022
Jaeger S Eissler M Schwarze M Schonhoff M Kretzer JP Bitsch RG

Aims. One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined. Methods. A tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD). Results. The BMD showed no statistically significant difference between both groups. Group A showed for all load levels significantly higher maximum relative motion compared to group S for 20° and 50° flexion. Group S improved the maximum failure load significantly compared to group A without additional cement pockets. Group S showed a significantly increased cement adhesion compared to group A. The cement penetration and cement mantle defect analysis showed no significant differences between both groups. Conclusion. From a biomechanical point of view, the additional cement pockets of the component have improved the fixation performance of the implant. Cite this article: Bone Joint Res 2022;11(4):229–238


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 1 - 1
7 Nov 2023
Kock FW Basson T Burger M Ferreira N
Full Access

This study aimed to investigate the outcomes of open tibia shaft fractures at a level one trauma center in a developing world setting. Specific objectives were to determine the association of time delay to antibiotic administration, surgical debridement, definitive skeletal stabilisation and soft tissue reconstruction, and the development of fracture-related infection (FRI). A retrospective cohort study included all adult patients with open tibia shaft fractures from July 2014 to June 2016 and January 2018 to December 2019. Patients who were skeletally immature at the time of injury, those with pathological fractures and who did not complete follow-up of at least three months were excluded. Patients were identified from hospital records. Data was captured in Microsoft Excel and analysed using STATISTICA. A Chi-squared was used to detect significant differences between groups. No association between infection and antibiotic administration was observed when patients were treated within or after 3 hours (p=0.625) or if patients had their first surgical debridement in theatre before or after 24 hours (p=0.259). Patients who waited more than five days for definitive skeletal fixation or soft tissue reconstruction had a significant increase in FRI (OR 4.7, 95% CI 2.0 – 10.9 and OR 4.7, 95% CI 2.0 – 11.0, respectively). Patients who underwent more than two formal debridements had a higher risk of developing FRI (OR 15.6, 95% CI 5.8 – 41.6). Whilst administration of antibiotics within 3 hours of presentation to the emergency unit had no impact on the development of FRI, time delays in managing open tibia shaft fractures are associated with an increased risk for FRI. Definitive soft tissue reconstruction and skeletal stabilization should not be delayed for more than five days


Bone & Joint Open
Vol. 3, Issue 10 | Pages 832 - 840
24 Oct 2022
Pearson NA Tutton E Joeris A Gwilym SE Grant R Keene DJ Haywood KL

Aims. To describe outcome reporting variation and trends in non-pharmacological randomized clinical trials (RCTs) of distal tibia and/or ankle fractures. Methods. Five electronic databases and three clinical trial registries were searched (January 2000 to February 2022). Trials including patients with distal tibia and/or ankle fractures without concomitant injuries were included. One reviewer conducted all searches, screened titles and abstracts, assessed eligibility, and completed data extraction; a random 10% subset were independently assessed and extracted by a second reviewer at each stage. All extracted outcomes were mapped to a modified version of the International Classification of Functioning, Disability and Health framework. The quality of outcome reporting (reproducibility) was assessed. Results. Overall, 105 trials (n = 16 to 669 participants) from 27 countries were included. Trials compared surgical interventions (n = 62), post-surgical management options (n = 17), rehabilitative interventions (n = 14), surgical versus non-surgical interventions (n = 6), and pre-surgical management strategies (n = 5). In total, 888 outcome assessments were reported across seven domains: 263 assessed body structure or function (85.7% of trials), 136 activities (68.6% of trials), 34 participation (23.8% of trials), 159 health-related quality of life (61.9% of trials), 247 processes of care (80% of trials), 21 patient experiences (15.2% of trials), and 28 economic impact (8.6% of trials). From these, 337 discrete outcomes were described. Outcome reporting was inconsistent across trials. The quality of reporting varied widely (reproducibility ranged 4.8% patient experience to 100% complications). Conclusion. Substantial heterogeneity in outcome selection, assessment methods, and reporting quality were described. Despite the large number of outcomes, few are reported across multiple trials. Most outcomes are clinically focused, with little attention to the long-term consequences important to patients. Poor reporting quality reduces confidence in data quality, inhibiting data synthesis by which to inform care decisions. Outcome reporting guidance and standardization, which captures the outcomes that matter to multiple stakeholders, are urgently required. Cite this article: Bone Jt Open 2022;3(10):832–840


Bone & Joint Open
Vol. 3, Issue 9 | Pages 733 - 740
21 Sep 2022
Sacchetti F Aston W Pollock R Gikas P Cuomo P Gerrand C

Aims. The proximal tibia (PT) is the anatomical site most frequently affected by primary bone tumours after the distal femur. Reconstruction of the PT remains challenging because of the poor soft-tissue cover and the need to reconstruct the extensor mechanism. Reconstructive techniques include implantation of massive endoprosthesis (megaprosthesis), osteoarticular allografts (OAs), or allograft-prosthesis composites (APCs). Methods. This was a retrospective analysis of clinical data relating to patients who underwent proximal tibial arthroplasty in our regional bone tumour centre from 2010 to 2018. Results. A total of 76 patients fulfilled the inclusion criteria and were included in the study. Mean age at surgery was 43.2 years (12 to 86 (SD 21)). The mean follow-up period was 60.1 months (5.4 to 353). In total 21 failures were identified, giving an overall failure rate of 27.6%. Prosthesis survival at five years was 75.5%, and at ten years was 59%. At last follow-up, mean knee flexion was 89.8° (SD 36°) with a mean extensor lag of 18.1° (SD 24°). In univariate analysis, factors associated with better survival of the prosthesis were a malignant or metastatic cancer diagnosis (versus benign), with a five- and ten-year survival of 78.9% and 65.7% versus 37.5% (p = 0.045), while in-hospital length of stay longer than nine days was also associated with better prognosis with five- and ten-year survival rates at 84% and 84% versus 60% and 16% (p < 0.001). In multivariate analysis, only in-hospital length of stay was associated with longer survival (hazard ratio (HR) 0.23, 95% confidence interval (CI) 0.08 to 0.66). Conclusion. We have shown that proximal tibial arthroplasty with endoprosthesis is a safe and reliable method for reconstruction in patients treated for orthopaedic oncological conditions. Either modular or custom implants in this series performed well. Cite this article: Bone Jt Open 2022;3(9):733–740


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 10 - 10
1 Mar 2009
Attal R Müller M Hansen M Bail H Kirjavainen M Hammer T Blauth M Höntzsch D Rommens P
Full Access

Introduction: The Expert Tibia Nail was designed to address proximal, shaft, segmental and distal tibia fractures in one implant. Multiple locking options in various directions provide more stability and reduce the risk of secondary malalignment. Angle stable cancellous bone locking screws in the tibia head also improve fixation. We evaluated this new implant in our series in a prospective, multicenter setting. Methods: 190 patients were treated in 10 participating centers using the Expert Tibia Nail (Synthes). 127 patients suffered polytrauma, 58 presented as open fractures. Within the framework of the study 5 cases were proximal tibia fractures, 108 shaft fractures, 56 distal fractures, and 21 segmental fractures. These were followed-up postoperatively, after 3 months and one year and evaluated radiologically and clinically with regard to malalignment, union rate and complications. Results: Non union occurred in 9 cases after one year of follow up (n=150). 20 patients showed delayed union. The rate of open and complex fractures was high in this group. Dynamisation was performed in 10 cases. Valgus/varus and recurvatum/antecurvatum malalignment of more than 5 degrees occurred in 13 cases. Stable reduction was achieved in 144 cases. In 4 complex fractures, initial reduction went into malalignment. 2 patients developed a deep infection after 3rd degree open fractures. 34 patients suffered from pain in the operated area. 6 screws broke during the follow-up. Discussion: The Expert Tibia Nail proved to be an excellent tool to treat tibia fractures. Not only shaft fractures but also complex fractures in the proximal and distal metaphyseal area can be successfully stabilized due to advanced locking options and design of the nail. The rate of malalignment, non-union and complications was low


Bone & Joint Research
Vol. 10, Issue 9 | Pages 611 - 618
27 Sep 2021
Ali E Birch M Hopper N Rushton N McCaskie AW Brooks RA

Aims. Accumulated evidence indicates that local cell origins may ingrain differences in the phenotypic activity of human osteoblasts. We hypothesized that these differences may also exist in osteoblasts harvested from the same bone type at periarticular sites, including those adjacent to the fixation sites for total joint implant components. Methods. Human osteoblasts were obtained from the acetabulum and femoral neck of seven patients undergoing total hip arthroplasty (THA) and from the femoral and tibial cuts of six patients undergoing total knee arthroplasty (TKA). Osteoblasts were extracted from the usually discarded bone via enzyme digestion, characterized by flow cytometry, and cultured to passage three before measurement of metabolic activity, collagen production, alkaline phosphatase (ALP) expression, and mineralization. Results. Osteoblasts from the acetabulum showed lower proliferation (p = 0.034), cumulative collagen release (p < 0.001), and ALP expression (p = 0.009), and produced less mineral (p = 0.006) than those from the femoral neck. Osteoblasts from the tibia produced significantly less collagen (p = 0.021) and showed lower ALP expression than those from the distal femur. Conclusion. We have demonstrated for the first time an anatomical regional variation in the biological behaviours of osteoblasts on either side of the hip and knee joint. The lower osteoblast proliferation, matrix production, and mineralization from the acetabulum compared to those from the proximal femur may be reflected in differences in bone formation and implant fixation at these sites. Cite this article: Bone Joint Res 2021;10(9):611–618


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 16 - 16
1 Dec 2021
Munford M Stoddart J Liddle A Cobb J Jeffers J
Full Access

Abstract. Objectives. Unicompartmental and total knee arthroplasty (UKA and TKA) are successful treatments for osteoarthritis, but monolithic implants disrupt the natural homeostasis of bone which leads to bone loss over time. This can cause problems if the implant needs to be revised. This study aimed to demonstrate that tibial implants made from titanium lattice could replace the tibial condyle surface while minimising disruption of the bone's natural mechanical loading environment. A secondary aim was to determine whether implants perform better if they replicate more closely bone's mechanical modulus, anisotropy and spatial heterogeneity. This study was conducted in a human cadaveric model. Methods. In a cadaveric model, UKA and TKA procedures were performed on 8 fresh-frozen knee specimens by a board-certified consultant orthopaedic surgeon, using tibial implants made from conventional monolithic material and titanium lattice structures. Stress at the bone-implant interfaces was measured with pressure film and compared to the native knee. Results. Titanium lattice implants were able to restore the mechanical environment seen in the native tibia for both UKA and TKA designs. Maximum stress at the bone-implant interface ranged from 1.2–3.3MPa compared to 1.3–2.7MPa for the native tibia. The conventional UKA and TKA implants reduced the maximum stress in the bone by a factor of 10 and 9.7 respectively. The conventional UKA and TKA implants caused 71% and 77% of bone surface area to be underloaded compared to the native tibia. Conclusions. Titanium lattice implants can maintain the natural mechanical loading in the proximal tibia after UKA and TKA. This may help maintain normal bone homeostasis throughout the life of the implant. These encouraging data indicate normal bone homeostasis can be maintained after arthroplasty using manufacturing methods already in widespread use. This would maintain bone quality throughout the life of the implant and alleviate complications at revision surgery


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 33 - 33
1 May 2021
Bari M
Full Access

Introduction. Correction of multiplanar bone deformities in children is indicated for prevention of secondary orthopaedic complications. Different problems related to surgical intervention were reported: non-union, delayed union, recurrent deformity, refracture, nerve palsy and pin tract infection. The aim of this study was to show the results of children femur and tibia bowing deformities by Ilizarov technique. Materials and Methods. We analysed 27 cases of children femur and tibia bowing deformities under the age of 13 yrs. Simultaneous deformity correction in femur and tibia was done with Ilizarov device in ipsilateral side. Contralateral side was operated after 14 days. Results. The duration of Ilizarov fixation was 130 days on an average. The deformity correction was achieved with a proper alignment in all the cases. Conclusions. Bowing of femur and tibia can be corrected simultaneously by Ilizarov fixation with minimum complications. There were no recurrent deformities in our cases


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 40 - 40
11 Apr 2023
Mahdi H Hardisty M Fullerton K Huang C Vachhani K Nam D Whyne C
Full Access

µCT images are commonly analysed to assess changes in bone density and architecture in preclinical murine models. Several platforms provide automated analysis of bone architecture parameters from volumetric regions of interest (ROI). However, segmentation of the regions of subchondral bone to create the volumetric ROIs remains a manual and time-consuming task. This study aimed to develop and evaluate automated pipelines for trabecular bone architecture analysis of mouse proximal tibia subchondral bone. A segmented dataset involving 62 knees (healthy and arthritic) from 10-week male C57BL/6 mice were used to train a U-Net type architecture, with µCT scans (downsampled) input that output segmentation and bone volume density (BV/TV) of the subchondral trabecular bone. Segmentations were upsampled and used in tandem with the original scans (10µ) as input for architecture analysis along with the thresholded trabecular bone. The analysis considered the manually and U-Net segmented ROIs using two available pipelines: the ITKBoneMorphometry library and CTan (SKYSCAN). The analyses included: bone volume (BV), total volume (TV), BV/TV, trabecular number (TbN), trabecular thickness (TbTh), trabecular separation (TbSp), and bone surface density (BSBV). There was good agreement for bone measures between the manual and U-Net pipelines utilizing ITK (R=0.88-0.98) and CTan (R=0.91-0.98). ITK and CTan showed good agreement for BV, TV, BV/TV, TbTh and BSBV (R=0.9-0.98). However, a limited agreement was seen between TbN (R=0.73) and TbSb (R=0.59) due to methodological differences in how spacing is evaluated. This U-Net/ITK pipeline seamlessly automated both segmentation and quantification of the proximal tibia subchondral bone. This automated pipeline allows the analysis of large volumes of data, and its open-source nature may enable the standardization of stereologic analysis of trabecular bone across different research groups