Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 67 - 67
1 Apr 2019
DesJardins J Lucas E Chillag K Voss F
Full Access

Background

Clinical and anatomical complications from total knee replacement (TKR) procedures are debilitating, and include weakness, damage, and the loss of native anatomy. As the annual number of primary TKR surgeries in the United States has continued to rise, to a projected 3.48 million in 2030, there has been a concomitant rise in revision surgery. Damage to or loss of native knee anatomy as a result of TKR revision can leave the patient with irreversible knee dysfunction, which is a contra-indication for most TKR systems on the market. This leaves the multi-revision patient with limited medical options. Complete fusion of the joint, known as arthrodesis, is indicated in some cases. Arthrodesis is also commonly indicated for traumatic injury, bone loss, quadriceps extensor mechanism damage, and osteosarcoma. While this treatment may resolve pain and allow a patient to walk, the inability to flex the knee results in considerable functional complications. Patients with arthrodesis are unable to drive, sit in close-quarter spaces, or engage in a significant number of activities of daily living.

Product Statement

The authors have developed and patented the Engage Knee System, a novel TKR system that allows a patient to lock and unlock the knee joint by means of a handheld, non-invasive device. An internal locking mechanism is constructed of materials that have been used in orthopedic joint replacements that have been approved through the FDA 510(k) process. A lightweight, handheld magnetic device is used to actuate the locking mechanism. No percutaneous components are required or present. This device allows a patient to lock their knee joint in full extension to ambulate with the functional equivalence of an arthrodesis, but allows a patient to unlock the device and bend the knee to engage in passive activities that would be otherwise difficult or impossible. The IP portfolio for this technology is owned by Clemson University, and they are seeking a partner/licensee to pursue further technology development and validation.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 65 - 65
1 Apr 2019
DesJardins J Stokes M Pietrykowski L Gambon T Greene B Bales C
Full Access

Introduction

There are over ½ million total knee replacement (TKR) procedures performed each year in the United States and is projected to increase to over 3.48 million by 2030. Concurrent with the increase in TKR procedures is a trend of younger patients receiving knee implants (under the age of 65). These younger patients are known to have a 5% lower implant survival rate at 8 years post-op compared to older patients (65+ years), and they are also known to live more active lifestyles that place higher demands on the durability and functional performance of the TKR device. Conventional TKR designs increase articular conformity to increase stability, but these articular constraints decrease patient range of knee motion, often limiting key measures of femoral rollback, A/P motion, and deep knee flexion. Without this articular constraint however, many patients report TKR “instability” during activities such as walking and stair descent, which can significantly impede confidence of movement. Therefore, there is a need for a TKR system that can offer enhanced stability while also maintaining active ranges of motion.

Materials and Methods

A novel knee arthroplasty system has been designed that uses synthetic ligament systems that can be surgically replaced, to provide ligamentous stability and natural motion to increase the functional performance of the implant. A computational anatomical model (AnyBody) was developed that incorporated ligaments into an existing Journey II TKR. Ligaments were modeled and given biomechanical properties from literature. Simulated A/P drawer tests and knee flexion were analyzed for 2,916 possible cruciate ligament location and length combinations to determine the effects on the A/P stability of the TKR. A physical model was then constructed, and the design was verified by performing 110 N A/P drawer tests under 710 N of simulated body weight.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 65 - 65
1 Apr 2018
DesJardins J Stokes M Pietrykowski L Gambon T Greene B Bales C
Full Access

Introduction

There are over one-half million total knee replacement (TKR) procedures performed each year in the United States and is projected to increase to over 3.48 million by 2030. Concurrent with the increase in TKR procedures is a trend of younger patients receiving knee implants (under the age of 65). These younger patients are known to have a 5% lower implant survival rate at 8 years post-op compared to older patients (65+ years), and they are also known to live more active lifestyles that place higher demands on the durability and functional performance of the TKR device. Conventional TKR designs increase articular conformity to increase stability, but these articular constraints decrease patient range of knee motion, often limiting key measures of femoral rollback, A/P motion, and deep knee flexion. Without this articular constraint however, many patients report TKR “instability” during activities such as walking and stair descent, which can significantly impede confidence of movement. Therefore there is a need for a TKR system that can offer enhanced stability while also maintaining active ranges of motion.

Materials and Methods

A novel knee arthroplasty system was designed that uses synthetic ligament systems that can be surgically replaced, to provide ligamentous stability and natural motion to increase the functional performance of the implant. Using an anatomical knee model from the AnyBody software, a computational model that incorporated ligaments into an existing Journey II TKR was developed. Using the software ligaments were modeled and given biomechanical properties developed from equations from literature. Simulated A/P drawer tests and knee flexion test were analyzed for 2,916 possible cruciate ligament location and length combinations to determine the effects on the A/P stability of the TKR. A physical model was constructed, and the design was verified by performing 110 N A/P drawer tests under 710 N of simulated body weight.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 64 - 64
1 Apr 2018
DesJardins J Bales C Helms S
Full Access

Introduction

The accumulation of proteins and bacteria on implant surfaces is a critical concern in the biomedical field, especially with respect to the potential of biofilm formation on implant surfaces. Material surface wettability is often used as a predictor of potential colonization of specific bacterial strains. Surface roughness has also been shown to have a strong relationship with biofilm formation, as rougher surfaces tend to have a stronger affinity to harbor bacterial colonies. The modification of implant surfaces to impart a biofilm resistant layer can come at the expense of increasing surface roughness however, and it is therefore important to determine how the variables of wettability and roughness are affected by any new surface coating technologies. In the current work, a novel CoBlast (C) process that impregnates alumina (A) at 50 μm grit (5) or 90 μm grit (9) sizes, with the possible addition of polytetrafluoroethylene (P) onto titanium surfaces, combined with a plasma coating process called BioDep, that coats the surface with chitosan (X) with the possible addition of vancomycin (V), were evaluated for wettability and surface roughness to determine their potential as biofilm resistant treatments on implants.

Materials and Methods

N=65 titanium alloy samples (n=5 for 13 sample modification types as described above and in the figure legends below) were analyzed for surface roughness and wettability. Following cleaning in ethanol, roughness testing (Ra, Rq, Rt and Rz, Wyko NT-2000 optical profilometer @ 28.7× magnification, FOV of 164×215 μm) at 5 different surface locations per specimen, and contact angle analysis was performed (2 μL water drops, KRUSS EasyDrop). Statistical differences between groups was determined using ANOVA.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 184 - 184
1 Jul 2014
Hydorn C Nathe K Kanwisher M DesJardins J Rogers M Bertram A
Full Access

Summary Statement

This study examined the fixation stiffness of 13 tibial and 12 femoral Salter-Harris fracture fixation methods, and determined that screws and screws+ k-wires methods provided the highest stability. In situations where k-wire use is unavoidable, threaded k-wires are preferable.

Introduction

Salter-Harris fractures of the proximal tibia and distal femur are common in pediatric patients that present to orthopedic surgeons. Salter-Harris type I fractures are characterised by breaks that extend only through the physis while Salter-Harris II fractures are the most common, accounting for 85% of Salter-Harris fractures, and extend past the growth plate, exiting through the metaphyseal bone. Fixation of these fracture types can be accomplished using a variety of methods including the use of Kirschner wires, cannulated screws, and a combination of both materials. Stability of fracture fixation is of utmost importance as persistent motion at the fracture margin leads to deformity. The purpose of this study is to analyze the biomechanical efficacy of various fixation methods used to stabilise Salter-Harris I and II fracture patterns in both the proximal tibia and distal femur. Stiffness, the primary gauge of efficacy, will be tested in flexion and extension, varus and valgus movement, and internal and external rotation and will be compared to determine the optimal fixation method.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 425 - 425
1 Apr 2004
Harman M DesJardins J Banks S Benson L LaBerge M Hodge W
Full Access

Validation of input parameters and the resulting polyethylene damage is essential for knee joint wear simulators to be useful in prospective evaluations. The purpose of this study was to compare damage patterns on polyethylene inserts wear tested on a knee simulator with inserts retrieved after well-functioning total knee arthroplasty (TKA).

Five polyethylene tibial inserts from a PCL-retaining knee prosthesis (Natural Knee) were wear tested on an Instron/Stanmore simulator in 50% bovine serum. The input consisted of ISO 14243 force-controlled testing standard to simulate human gait for 5 million cycles. Nine polyethylene tibial inserts (Natural Knee) were retrieved from patients after 52+45 months (13-124) of successful function. The inserts were retrieved post-mortem (n=7) and for pain (n=2). Articular damage was assessed and the circumference of each damage region digitized. The damage size, location and linear surface deformation were measured and the deformation rate (mm/106 cycles or mm/year) was calculated.

The linear deformation rate for all inserts decreased considerably with time. Lateral damage was located significantly more posterior than the medial damage on both the simulated and retrieved inserts, corresponding to femoral external rotation. Retrieved inserts had larger lateral damage, whereas simulator inserts had larger medial damage. The AP extent of damage on the retrieved inserts was significantly greater than the extent on the simulator inserts. Three retrieved inserts had substantial delamination, whereas none of the simulator inserts had delamination.

There was good agreement in the deformation rates for the simulator and retrieved inserts. However, retrieved inserts with delamination show an increased deformation rate and this type of damage did not occur on simulator inserts. The greater AP extent of damage and larger lateral damage on the retrieved inserts suggest that in vitro wear simulation should perhaps include a more complete range of patient activity dynamics to better predict in vivo damage.