Vol. 91-B, Issue SUPP_I | Pages 85 - 85
1 Mar 2009
Giron F Aglietti P Cuomo P Losco M Mondanelli N
Full Access

Introduction : The purpose of the study is to compare in a randomised clinical double blind trial two methods of hamstring ACL reconstruction, the SIngle Bundle (SB) and the Double Bundle (DB).

Materials and methods: Seventy patients, with a chronic ACL insufficiency, were randomized to receive a unilateral single or double bundle ACL reconstruction. All the operations were performed by the same surgeon using the same two incision outside-in technique. The tibial guide wire was introduced with a 65 degrees Howell guide in extension to avoid impingment. To introduce the second tibial wire (posterolateral wire) a prototype guide that lets you place the wire with a fixed angulation and a fixed distance (9 mm) from the first was used. On the femoral side we used a modified Rear Entry guide. In a SB reconstruction the 10.00 o’clock position (right knee), intermediate between the two anatomic bundles, was used. In a DB reconstruction the first wire was placed in the anteromedial insertion area, close to the “over the top” position on the lateral wall and for the second wire the same prototype guide that gives you the correct angulation and distance with the first (10 mm) was used. The direction was chosen in order to exit 5 mm close to the posterior cartilage. The graft was prepared and pretensioned as to have two arms of the same diameter. It was fixed on the cortex of the tibia by means of a titanium ring bridge when doing a SB and looped around a cortical bony bridge when doing a DB. Tensioning and femoral fixation of the SB was done at 20 degrees, while in the DB tensioning and fixation of the PL bundle was achieved first after cycling at 10–15 degrees and of the AM bundle at 40–45 degrees. Femoral fixation was obtained via RCI titanium interference screws and one additional cortical titanium staple. The same moderately aggressive rehabilitation was utilized in both groups. Outcome assessment was performed by an indipendent observer, blinded to the involved leg and type of reconstruction, using the new IKDC form, the KOOS score, the KT-1000 arthrometer.

Results: All patients reached a minimum follow-up of one year. No difference was found in terms of overall KOOS and IKDC subjective scores. A significant difference was found (p< .001) in KT data and in IKDC final ojective scores (Excellent-A-result: 73% SB and 95% DB). he DB group showed a tred to less pivot shift (glide).

Conclusion: In the short period the DB reconstruction offered better knee stability and better objective results than the 10.00 o’clock SB. Longer follow up and accurate instrumented in vivo rotational stability assessment is probably needed to further disclose small but important differences.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 426 - 426
1 Oct 2006
Cuomo P Giron F Bull A Amis A Aglietti P Siva R Hill A De Caro R
Full Access

Objective: To compare double bundle ACL reconstruction kinematics to single bundle reconstruction, intact knee and ACL deficient knee employing an electromagnetic device in six cadaver knees under different antero-posterior and rotational loading conditions.

Methods: All the tests were performed with an intact ACL, with a deficient ACL and after single and double bundle ACL reconstruction.

In double bundle ACL reconstruction two tibial tunnels were drilled: for the anteromedial the 65 degrees Howell guide was employed; the posterolaetral was drilled through a prototype jig attached to the first guide. Two femoral tunnels were drilled outside-in with the Rear Entry guide. A 6 millimetres bovine tendon graft was employed and fixed to bone with interference screws.

Results: Posterior drawer loading conditions did not show differences between intact knee, single and double ACL reconstruction independently from rotational stresses.

Under an anterior drawer test double bundle ACL reconstruction restored anteroposterior laxity significantly better than single bundle reconstruction at 20 and 40 degrees of flexion. A trend towards a better rotational control of double bundle reconstruction was observed in extension.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 426 - 426
1 Oct 2006
Ciardullo A Aglietti P Giron F Cuomo P Nannini S Violini S
Full Access

Thirty patients with chronic lesions of the ACL underwent reconstruction of the ACL with double bundle technique. A wire at 65° was used for AM tibial tunnel and a prototype was used for the PL. For femoral tunnels, a transtibial technique was applied in fifteen patients and the outside-in technique was used in fifteen more. All patients had an MRI after three months. The tunnels position was studied with Amis’ circle method, as a proportion of the circle’s height and width. We compared the proportion of the anatomical data on fourteen cadaveric knees. In the transtibial group the AM tunnel was at 56% of the circle’s height and at 65%of the depth (mean); the PL was at 40% of the circle’s height and 54% of the depth. In the out-side group the AM tunnel was 48%of the circle’s height and at 66% of the depth; the PL one was at 32%of the circle’s height and at 61%of the depth. In corpses the AM insertion was at 50% of the circle’s height and 69% of the depth (mean). In conclusion the outside-in technique allows better anatomical positioning.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 426 - 426
1 Oct 2006
Giron F Aglietti P Cuomo P Losco M Mondanelli N
Full Access

Purpose: Prospectively compare 3 different techniques of ACL reconstruction with autologous hamstrings graft.

Material and methods: 3 comparable groups of 25 knees each were selected. An arthroscopic single incision reconstruction was performed in all groups. In group A, a single bundle graft was inserted. In group B a double bundle reconstruction was performed with 1 tibial and 2 femoral tunnels. In group C, 2 tibial and 2 femoral tunnels were drilled. Fixation was achieved in all knees with Endobutton CL proximally and Washerloc screw distally. Outcome assessment was performed at 4 and 12 months postoperatively by an independent observer, using new IKDC evaluation form, the KT-1000 arthrom-eter, and a radiographic investigation.

Results: At 12 months FU the subjective score was 81 in group A, 76 in group B, and 89 in group C. The final IKDC score was satisfactory (A+B) in over 90% of the patients. The KT-1000 anterior tibial translation was 2.3, 2.5 and 1.9 mm in group A, B, and C respectively. The radiographic study showed no differences between the 3 groups in terms of incidence of tunnel widening.

Conclusions: At a minimum FU of 1 year we could not show a statistically advantage of the two bundle compared to the single bundle.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 186 - 187
1 Apr 2005
Lup D Aglietti P Giron F Mondanelli N Losco M Cuomo P
Full Access

In the last few years the number of women who practise sport activities has substantially increased and this has led to an increase in the incidence of ACL tear in females. The aim of this study is to assess outcome differences at a minimum 3-year follow-up after ACL reconstruction in women using either a patellar tendon (BPTB) or a quadrupled-looped hamstring (DSTG) autograft fixed with modern devices.

Fifty women with a chronic, isolated ACL tear were randomised to receive a DSTG or BPTB graft for ACL reconstruction. Both groups were comparable as to age, injury-surgery, activity level, meniscal tears, surgical technique and reabilitation. All patients were prospectively evaluated by an independent observer using the IKDC form, the FKSAKP Score, the KT-1000 arthrometer and the Cybex NORM dynamometer. A radiographic study was performed to investigate tunnel widening.

All but two patients were satisfied with the reconstruction. The average side-to-side difference in anterior tibial translation was 2.4 mm in the BPTB group and 2.5 mm in the DSTG group. The final result was A (normal knee) in 56% and in 60% of the BPTB and the DSTG knees, respectively. A failure (4%) was present in each group. Muscle strength deficits at 60°/s, 120°/s and 180°/s were within 10% for extensors and within 5% for flex-ors in both groups. No statistically significant differences were found in terms of subjective satisfaction, objective evaluation, knee stability and muscle strength recovery. The BPTB group showed a higher incidence of postoperative kneeling discomfort (p< 0.05) and a larger area of decreased skin sensitivity (p< 0.001). The DSTG group showed a higher incidence of femoral tunnel widening (p=0.02).

Using strong and stiff fixation devices, ACL reconstruction in women is not influenced by the graft choice.