Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 150 - 150
1 Feb 2017
Gruebl A Salak M Fellinger E Spittler A
Full Access

Introduction

It has been shown in vitro that human monocytes can phagocytose submicron polyethylene wear particles generated from total hip arthroplasties (THA) with highly cross-linked polyethylene inlays. The aim of our study was to detect the presence and possible phagocytosis of such particles in peripheral blood monocytes of patients with respective THA.

Patients and methods

All patients were operated using the same implant, the cementless SL Plus stem; Bicon cup and a cross-linked polyethylene insert Rexpol (Smith and Nephew). Besides clinical and radiographic check-up, blood samples were collected at follow-up and analyzed by flow cytometry. Polyethylene can be identified by its auto fluorescence when stimulated by a laser with the wavelength of fluorescein isothiocyanate (FITC). Presence of wear particles in monocytes was identified by determination of their size and granularity. Some samples were scrutinized by confocal laser scanning microscopy to correlate the intracellular position of the particles. Blood samples of patients without total joint replacement served as controls.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 137 - 137
1 May 2016
Lass R Gruebl A Kolb A Stelzeneder D Pilger A Kubista B Giurea A Windhager R
Full Access

Introduction

In a recent study we evaluated the clinical and radiographic long-term results as well as the serum metal concentrations of 105 cementless primary total hip prosthesis, performed between November 1992 and May 1994 with a 28-mm high-carbide-concentration metal-on-metal articulating surfaces. Forty-one patients who had had a total of forty-four arthroplasties were available for follow-up evaluation at a minimum of seventeen years postoperatively.

The median serum cobalt concentration of the patients with their hip replacement as the only source of cobalt was 0.7 µg/L (range 0.4–5.1µg/L), showing no significant difference to the previous study after a minimum of 10 years follow-up. We were investigating the systemic dissemination, which in turn, did not show more severe effects, such as carcinogenicity or renal failure. There are many complex issues associated with the analysis of metal ions, including collecting technique, analysis and reporting of the results. At the AAOS in March 2013, the Hip Society mentioned, that systemic ion levels are just one factor in the evaluation and should not be relied upon solely to determine the need for revision surgery. Furthermore, the correlation between cobalt or chromium serum, urin or synovial fluid levels and adverse local tissue reactions is incompletely understood.

Patients and Methods

In our present study we evaluated the serum, urin as well as the joint aspirate metal concentrations, of cementless total hip arthroplasties with a high-carbon, metal-on-metal bearing (Metasul®) at a mean of eighteen-years follow-up. We performed a correlation analysis to evaluate the relationship between these values and to determine whether elevated serum metal concentrations are associated with elevated and local metal concentrations and with early failure of metal-on-metal articulations.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 294 - 294
1 Mar 2004
Zehetgruber H Wurnig C Gruebl A Giurea A
Full Access

Aims: Since several authors query the beneþt of surgical repair of rotator cuff tears, especially in the elderly patients, the purpose of our study was to observe patients with asymptomatic rotator cuff tears. Methods: A series of 235 patients were enrolled clinically during the time of hospitalization, additional ultrasound and X-ray examination of the shoulder was done. In 14 patients ultrasound revealed a clinical asymptomatic cuff tear, afþrmed by MR examination. All 14 patients were observed for 5 years with regular clinical and sonographic examination. Additional MRI was done at 5 year follow-up. Results: At the time of the last follow-up, only one patient developed speciþc symptoms, such as pain, nocturnal pain and weakness due to the cuff tear. Operative treatment for rotator cuff repair was scheduled. Active range of motion deceased from 180û to 167û in ßexion and from 178û to 165û in abduction. Also range of external and internal rotation decreased. Radiological aggravation of cuff arthropathy was observed in all cases. Conclusion: Results of this study suggest that a rotator cuff tear can remain asymptomatic for years, although radiological signs of osteoarthrosis increases.