Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_9 | Pages 3 - 3
1 Sep 2019
Cabrita M Nijeweme - d'Hollosy WO Jansen-Kosterink S Hermens H
Full Access

Background

Patients with Neck and/or Low Back Pain (NLBP) constitute a heterogeneous group with the prognosis and precise mix of factors involved varying substantially between individuals. This means that a one-size-fits-all approach is not recommended, but methods to tailor treatment to the individual needs are still relatively under-developed. Moreover, the fragmentation of disciplines involved in its study hampers achieving sound answers to clinical questions. Data mining techniques open new horizons by combining data from existing datasets, in order to select the best treatment at each moment in time to a patient based on the individual characteristics.

Method

Within the Back-UP project (H2020 #777090) a multidisciplinary consortium is creating a prognostic model to support more effective and efficient management of NLBP, based on the digital representation of multidimensional clinical information. Patient-specific models provide a personalized evaluation of the patient case, using multidimensional health data from the following sources: (1) psychological, behavioral, and socioeconomic factors, (2) biological patient characteristics, including musculoskeletal structures and function, and molecular data, (3) workplace and lifestyle risk factors.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 162 - 162
1 May 2012
Hughes J Malone A Zarkadas P Jansen S
Full Access

This study reviews the early results of Distal Humeral Hemiarthroplasty(DHH) for distal humeral fracture and proposed a treatment algorithm incorporating the use of this technique in the overall management of distal humeral fractures.

DHH was performed on 30 patients (mean 65 years; 29-91) for unreconstructable fractures of the distal humerus or salvage of failed internal fixation. A triceps on approach was used in six and an olecranon osteotomy in 24. A Sorbie Questor prosthesis (Wright Medical Technology) was used in 14 patients and a Latitude (Tornier) in 16. Clinical review at a mean of 25 months (3–88) included the American Shoulder and Elbow Surgeons elbow outcomes instrument (ASES), Mayo Elbow Performance Index (MEPI) and radiological assessment.

At follow up of 28 patients mean flexion deformity was 25 degrees, flexion 128 degrees, range of pronosupination 165 degrees, mean ASES 83, MEPI 77 and satisfaction 8/10. Acute cases scored better than salvage cases. Re- operation was required in 16 patients (53%); two revisions to a linked prosthesis for periprosthetic fracture and aseptic loosening at 53 and 16 months, 12 metalwork removals and four ulnar nerve procedures. Posterolateral rotatory instability was present in one elbow, four had laxity and mild pain on loading (two with prosthesis or pin loosening), four had laxity associated with column fractures (two symptomatic) and 10 had asymptomatic mild laxity only. The triceps on approach had worse instability and clinical scores. Uncomplicated union occurred in all olecranon osteotomies and 86% of column fractures. One elbow had an incomplete cement mantle and seven had lucencies >1 mm; one was loose but acceptable. Five prostheses were in slight varus. Two elbows had early degenerative changes and 15 developed a medial spur on the trochlea.

This is the largest reported experience of DHH. Early results of DHH show good outcomes after complex distal humeral fractures, despite a technically demanding procedure. Better results are obtained for treatment in the acute setting and with use of an olecranon osteotomy. As a result of this experience anatomical and clinical pre-requisites and advise on technique are outlined. An algorithm for use of DHH in relation to total elbow arthroplasty and ORIF for the treatment of complex intra-articular distal humeral fractures with or without column fractures is proposed.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 280 - 280
1 Jul 2011
Malone A Zarkadas P Jansen S Hughes J
Full Access

Purpose: This study reviews the early results of elbow hemiarthroplasty for distal humeral fractures.

Method: Elbow hemiarthroplasty was performed on 30 patients (mean 65 years; 29–91) for unreconstruc-table fractures of the distal humerus or salvage of failed internal fixation. A ‘triceps on’ approach was used in six and an olecranon osteotomy in 24. A Sorbie Questor prosthesis (Wright Medical Technology) was used in 14 patients and a Lattitude (Tornier) in 16. Clinical review at a mean of 25 months (3–88) included the American Shoulder and Elbow Surgeons elbow outcomes instrument (ASES), Mayo Elbow Performance Index (MEPI) and radiological assessment.

Results: At follow up of 28 patients mean flexion deformity was 25 degrees, flexion 128 degrees, range of pro-nosupination 165 degrees, mean ASES 83, MEPI 77 and satisfaction 8/10. Acute cases scored better than salvage cases. Re-operation was required in 16 patients (53%); two revisions to a linked prosthesis for periprosthetic fracture and aseptic loosening at 53 and 16 months, 12 metalwork removals and four ulnar nerve procedures. Posterolateral rotatory instability was present in one elbow, four had laxity and pain on loading (two with prosthesis or pin loosening), four had laxity associated with column fractures (two symptomatic) and ten had asymptomatic laxity only. The triceps on approach had worse laxity and clinical scores. Uncomplicated union occurred in all olecranon osteotomies and 86% of column fractures. One elbow had an incomplete cement mantle and seven had lucencies > 1 mm; one was loose but acceptable. Five prostheses were in slight varus and two were flexed. Two elbows had early degenerative changes and 15 developed an osteophytic lip on the medial trochlea.

Conclusion: Early results of elbow hemiarthroplasty show good outcomes after complex distal humeral fractures, despite a technically demanding procedure, met-alware removal in 40%, symptomatic laxity in 12% and column non-union in 8%. Better results are obtained for treatment in the acute setting and with use of an olecranon osteotomy.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 256 - 256
1 May 2009
Malone A Zarkadas P Jansen S Hughes J
Full Access

This study reviews the early results of elbow hemiarthroplasty for distal humeral fracture. Elbow hemiarthroplasty was performed on 30 patients (mean 65 years; 29–91) for unreconstructable fractures of the distal humerus or salvage of failed internal fixation. A ‘triceps on’ approach was used in 6 and an olecranon osteotomy in 24. A Sorbie Questor prosthesis (Wright Medical Technology) was used in 14 patients and a Lattitude (Tornier) in 16. Clinical review at a mean of 25 months (3 – 88) included the American Shoulder and Elbow Surgeons elbow outcomes instrument (ASES), Mayo Elbow Performance Index (MEPI) and radiological assessment. At follow up of 28 patients, mean flexion deformity was 25 degrees, flexion 128 degrees, range of pronosupination 165 degrees, mean ASES 83, MEPI 77 and satisfaction 8/10. Acute cases scored better than salvage cases. Re-operation was required in 16 patients (53%); 2 revisions to a linked prosthesis for periprosthetic fracture and aseptic loosening at 53 and 16 months, 12 metalwork removals and 4 ulnar nerve procedures. Posterolateral rotatory instability was present in one elbow, 4 had laxity and pain on loading (2 with prosthesis or pin loosening), 4 had laxity associated with column fractures (2 symptomatic) and 10 had asymptomatic laxity only. The triceps on approach had worse laxity and clinical scores. Uncomplicated union occurred in all olecranon osteotomies and 86% of column fractures. One elbow had an incomplete cement mantle and 7 had lucencies > 1 mm; one was loose but acceptable. 5 prostheses were in slight varus and 2 were flexed. 2 elbows had early degenerative changes and 15 an osteophytic lip on the medial trochlea. Elbow hemiarthroplasty has good early results after complex distal humeral fractures, despite a demanding procedure, metalware removal in 40%, symptomatic laxity in 12% and column non-union in 8%. Better results are obtained for treatment in the acute setting and with use of an olecranon osteotomy.