Urinary catheterization in the postoperative period is known to increase the risk of deep joint infection following arthroplasty. A number of studies have attempted to elucidate the individual patient factors and surgical procedural factors which predispose patients to postoperative urinary retention. We conducted a retrospective observational study of three hundred patients to specifically determine the effect of the anaesthetic technique on the incidence of urinary retention following elective lower limb arthroplasty. One hundred consecutive patients were surveyed in each of three groups differing by the type of the anaesthetic technique and the drug administered; 1) general anaesthesia with femoral nerve block, 2) spinal anaesthesia with intrathecal fentanyl, and 3) spinal anaesthesia with intrathecal morphine. The incidence of urinary retention requiring catheterisation in male patients receiving intrathecal morphine was 58% compared with 10% and 6% for those who had general anaesthesia with femoral nerve block and intrathecal fentanyl, respectively. This difference was statistically significant (p<0.01). The incidence of urinary retention in females across all groups was =2%. The average residual volume of urine following catheterisation was 750ml (460-1500ml). Our findings show that the use of intrathecal morphine greatly increases the risk of postoperative urinary retention in male patients, whereas no significant increase was found amongst female patients. This risk should be carefully considered when choosing the type of intraoperative anaesthetic/analgesic combination employed in male patients and be rationalised against the intended benefits to the patient.
Cam-type femoro-acetabular impingement (FAI) is increasingly recognised as a cause of mechanical hip symptoms in young adults. It is likely that it is a cause of early hip degeneration. Ganz et al have developed a therapeutic procedure involving trochanteric flip osteotomy and dislocation of the hip, and have reported good results. We have developed an arthroscopic osteochondroplasty to reshape the proximal femur and relieve impingement. Fifty patients who presented with mechanical hip symptoms and had demonstrable cam-type FAI on radially-reconstructed MR arthrography, were treated by arthroscopic osteochondroplasty. Ten patients had a post-operative CT; from these images flexion and internal rotation range was tested in a virtual reality (VR) model to determine adequacy of resection. All patients were followed up for a minimum of one year, and post-operative Non-Arthritic Hip Scores (NAHS, maximum possible score 100) compared with pre-operative NAHS.Background
Methods
Femoro-acetabular impingement (FAI) is increasingly recognised as a cause of mechanical hip symptoms in sportspersons. In femoro-acetabular impingement abnormal contact occurs between the proximal femur and the acetabular rim during terminal motion of the hip as a result of abnormal morphologic features involving the proximal femur (CAM) or the acetabulum (Pincer) or both (Mixed) leading to lesions of acetabular labrum and the adjacent acetabular cartilage. It is likely that it is a cause of early hip degeneration. Ganz developed a therapeutic procedure involving trochanteric flip osteotomy and dislocation of the hip, and have reported good results. We have developed an arthroscopic technique to reshape the proximal femur and remove prominent antero-superior acetabular rim thereby relieving impingement. Twelve patients presented with mechanical hip symptoms and had demonstrable cam-type (eight patients) or mixed (four patients) FAI on radially-reconstructed MR arthrography, were treated by arthroscopic femoral osteochondroplasty and acetabular rim resection if indicated. All patients were competing at the highest level in their respective sport (football, rugby and athletics). All patients were followed up and post-operative Non-Arthritic Hip Scores (NAHS, maximum possible score 100) compared with pre-operative NAHS.Background
Methods
In patients with shoulder pain one of the important initial determinations is to assess the integrity of the rotator cuff. Clinical examination is often inconclusive. Compared with MRI and arthrography, ultrasound allows dynamic evaluation, is non-invasive, less expensive, less time-consuming and more acceptable to patients. The aim of the present study was to evaluate the accuracy of high resolution shoulder ultrasonography compared with arthroscopy in a series of consecutive patients with clinically suspected rotator cuff disease. 100 shoulders in 99 consecutive patients with shoulder pain who had undergone standardised pre-operative ultrasonography and subsequent arthroscopy between May 2004 and March 2006 were included in the study. There were 53 males and 46 females with a mean age of 59 years. The mean time interval between the ultrasonographic and the arthroscopic examinations was 227 days. For full thickness tears ultrasonography showed a sensitivity of 100%, specificity 83%, positive predictive value 80%, negative predictive value 100% and accuracy 90%. Ultrasonography showed a sensitivity of 83% in detecting partial thickness tears, specificity 94%, positive predictive value 86%, negative predictive value 93% and accuracy 91%.Introduction
Materials and methods
Management of periprosthetic femoral fractures above a Total Knee Arthroplasty remains a challenge. The different treatment options available include casting for undisplaced fractures, ORIF for a displaced fracture with a well-fixed implant or revision arthroplasty for a very distal fracture and for a fracture with a loose implant. We describe our experience in treating a very distal displaced supracondylar fracture above a well-fixed femoral component in a 68-year-old woman who was recently diagnosed with breast carcinoma and awaiting mastectomy. There was no evidence of metastatic disease. The knee replacement was done 4 years before and the patient did not have any symptoms in the knee prior to the fall. Conventional ORIF with IM nailing or plate osteosynthesis was not possible due to the very distal site of the fracture. We used a custom modified 95 degree angled blade plate in which a slot was cut in the middle of the blade halfway along its length to accommodate the pegs of the femoral component in the distal fragment. The fracture was reduced and fixed with the angled blade plate restoring length, alignment, and providing coronal stability. The patient had a satisfactory union at 3 months without deformity giving a good range of pain free movement in the knee. DCS and 95 degree angled blade plate have been used in the past with mixed results. The lag screw or the blade has to be inserted more proximally to avoid the femoral component and so the distal fixation is often sub optimal. In our case modification of the blade allowed more distal placement providing optimal fixation and avoiding complex revision surgery.
Our aims were to design a novel scale marker which does not require such precise positioning, and to compare the accuracy of this new marker with a standard single ball marker.
The posterior marker consists of a 75x75cm square foam mat, incorporating multiple 25.4mm metal rods arranged in series down the centre. The anterior marker is made from five 25.4mm steel balls, linked in series at 20mm intervals. The mat is positioned just underneath the patient’s pelvis as they lie supine for their radiograph. The five balls are placed in the midline over the patient’s suprapubic region, and the x-ray is then taken. The radiographic dimensions of the ball and rod which are located between the hips are then measured. The magnification of the hips may then be calculated from these dimensions using a simple equation. To validate the new “double” marker, it was compared with a conventional single marker ball. 74 hip arthroplasty patients undergoing routine radiographic follow up were recruited. Both the new double marker and the single marker were applied at the time of x-ray, the magnification according to each was calculated, and these were compared to the true radiographic magnification as determined from the known dimensions of the prosthesis. All markers were positioned by independent radiographers trained in their use.
The acetabular surface is divided radially into five zones (A, B, C, D, E) starting postero-inferior (A) and ending antero-inferior (E). Each zone is further divided in half into an outer and inner zone, forming ten zones in total i.e Ai, Ao, Bi, Bo.etc. This study was performed during therapeutic hip arthroscopy of 41 patients. Five surgeons took part in the study. After gaining access into the hip joint one of the surgeons identified three small intra-articular features (marks, small defects or blood clots) as X, Y and Z to some or all of the other 4 surgeons. Each of the other surgeons examined the hip independently without Discussion: and recorded the location on a hip map. If two surgeons had observed a point, this provided one pair to assess agreement; three or four surgeons provided three or six pairs respectively. Each observation of a point by a pair of surgeons (a point-pair) provided one opportunity for assessment of agreement.
All surgeons reported that they found the system easy to use. There was no difference in the level of disagreement between more and less experienced surgeons or a learning effect with time.
Subacromial corticosteroid injection has been shown to be effective in treating impingement syndrome. The exact mechanism of action is not clear but it may be due to its anti-inflammatory properties. However, there are potential side effects of steroid injection including tendon weakening, dermal atrophy and infection. NSAIDs may offer similar anti-inflammatory properties but without the side effects of corticosteroids. Tenoxicam is a long-acting water soluble NSAID and is available without irritant preservatives. Studies have shown that peri-articular Tenocixam injection was useful in treating painful shoulders and local tolerability was good. The aim of this study is to carry out a blinded ran-domised controlled study comparing subacromial Tenoxicam injection (NSAID) against methylprednisolone (steroid) injection in patients with clinical subacromial impingement syndrome. The study protocol was approved by local research ethics committee. Patients over 18 with a clinical diagnosis of subacromial impingement syndrome were considered eligible to this study. Patients with other known causes of shoulder pain, contraindication or sensitivity to NSAID and pregnant patients were excluded. Three functional outcome measures were used – Constant-Murley Shoulder Score, DASH and the Oxford Shoulder Score. The patients completed all three outcome measures before and 2, 4 and 6 weeks after the subacromial injection. Simple randomisation method was used and blinded to both researcher and the patient. 58 patients randomised into two groups were reviewed at the end of six weeks. Patients treated with subacromial steroid injection had a much better outcome compared to patients treated with subacromial tenoxicam injection and this difference was highly significant (p<
.003) In conclusion, patients with subacromial impingement syndrome have a better clinical outcome when treated with subacromial steroid injection than NSAID injection.
The deltopectoral approach is a common approach for Shoulder joint replacements where a normal subscapularis tendon is divided. Despite meticulous attention to the subscapular repair, suboptimal return of function was found on clinical examination in 92% of patients (Miller S L: Journal of Shoulder &
Elbow Surgery. 12(1): 29–34, February 2003). Therefore the aim was to study the integrity of the Subscapularis tendon in patients with Shoulder joint Replacements both clinical and ultrasound examination Methods: A cohort of 25 subjects who had undergone Copeland Shoulder replacements through deltopectoral approach were included. All patients had same technique of tendon-to-tendon repair and postoperative rehabilitation. After ethics committee approval subjects were evaluated prospectively with Lift off test, Belly press test and the Constant score. Average follow-up was 29.6 months. An experienced Radiologist performed the Ultrasound examination Results: Ultrasound examination showed 8 % (2 of 25) had full thickness rupture of subscapularis with 44% (11 of 25) showed mild to moderate atrophy of subscapularis muscle and 12%(3 of 25) severe atrophy. 20%(5 of 25) had Lift off test and Belly press test positive. 40%(10 of 25) had either or both of these tests positive. 60%(15 of 25) had clinical or radiological evidence of reduced function (Fisher exact test, P <
0.01). Constant score are 37.5 with full thickness tears compared to 59.4 with intact subsapularis tendon Conclusion: Subscapularis tendon function following shoulder replacement had received poor attention. It is deficient in over 60% of patients with joint replacement through Deltopectoral approach with tendon-to-tendon repair. We therefore conclude for this study that alternative techniques of subscapularis tendon repair or alternative approaches to the shoulder joint need to be considered to improve the functional outcome in these patients
The use of high resolution ultrasonography for the detection of rotator cuff tears has achieved only limited acceptance by orthopaedic surgeons. Uncertainty about the accuracy of ultrasonography may be a contributing factor. The purpose of this study was to evaluate the accuracy of high-resolution ultrasonography compared to shoulder arthroscopy in the detection of rotator cuff tears. 100 consecutive patients with shoulder pain in whom arthroscopic surgery was planned underwent standardized preoperative ultrasonography. The ultrasound examinations were done by a single experienced musculoskeletal radiologist using a standard protocol. The findings at ultrasound were classified into intact cuff, tendinopathy, partial-thickness tear, and full-thickness rotator cuff tears. The size of the tear was measured in centimetres. The location was designated as subscapularis, supraspinatus, infraspinatus, or a combination. All of the subsequent shoulder arthroscopies were done by a single surgeon. The presence or absence of a rotator cuff tear and the size and extent of the tear when present were recorded. We then compared the ultrasonographic findings with the definitive operative findings. For the detection of rotator cuff tears, ultrasound had a sensitivity of 95% and a specificity of 94%; accuracy 95%. There was 100% sensitivity for full thickness tears (specificity 91% and accuracy 95%), while for partial-thickness tears there was a sensitivity of 80%, (specificity 98% and accuracy 95%). In experienced hands, ultrasound is a highly accurate diagnostic method for detecting rotator cuff tears. The results of this study compare favourably with the published results of magnetic resonance imaging for the investigation of this condition. Furthermore, dynamic imaging and comparison with the opposite shoulder is possible with ultrasonography.