Vol. 104-B, Issue SUPP_12 | Pages 5 - 5
1 Dec 2022
McRae S Suter T Old J Zhang Y Woodmass J Marsh J Dubberley J MacDonald P
Full Access

Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon's visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is a safe alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization.

The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic biceps tenotomy/tenodesis, distal clavicle excision, subacromial decompression and labral repair by five fellowship-trained upper extremity surgeons were randomized into one of four arms: Pressure pump-controlled regular saline irrigation fluid (control), epinephrine (1ml of 1:1000) mixed in irrigation fluid (EPI), 1g intravenous TXA (TXA), and epinephrine and TXA (EPI/TXA). Visualization was rated on a 4-point Likert scale every 15 minutes with 0 indicating ‘poor’ quality and 3 indicating ‘excellent’ quality. The primary outcome measure was the unweighted mean of these ratings. Secondary outcomes included mean arterial blood pressure (MAP), surgery duration, surgery complexity, and adverse events within the first postoperative week.

One hundred and twenty-eight participants with a mean age (± SD) of 56 (± 11) years were randomized. Mean visualization quality for the control, TXA, EPI, and EPI/TXA groups were 2.1 (±0.40), 2.1 (±0.52), 2.6 (±0.37), 2.6 (±0.35), respectively. In a regression model with visual quality as the dependent variable, the presence/absence of EPI was the most significant predictor of visualization quality (R=0.525; p < 0 .001). TXA presence/absence had no effect, and there was no interaction between TXA and EPI. The addition of MAP and surgery duration strengthened the model (R=0.529; p < 0 .001). Increased MAP and surgery duration were both associated with decreased visualization quality. When surgery duration was controlled, surgery complexity was not a significant predictor of visualization quality. No adverse events were recorded in any of the groups.

Intravenous administration of TXA is not an effective alternative to epinephrine in the irrigation fluid to improve visualization during routine arthroscopic shoulder surgeries although its application is safe. There is no additional improvement in visualization when TXA is used in combination with epinephrine beyond the effect of epinephrine alone.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 56 - 56
1 Mar 2021
Malik S Hart D Parashin S McRae S Peeler J MacDonald P
Full Access

Abstract

Objectives

ACL graft-suture fixation can be constructed with needle or needleless techniques. Needleless techniques have advantages of decreased injury, preparation time and cost. The Nice Knot (NK) is common among upper extremity procedures; however, its efficacy in ACL reconstruction relative to other needleless methods is not well known. The purpose of this study was to biomechanically compare quadriceps tendon (QT) grafts prepared with the NK versus the modified Prusik Knot (PK).

Methods

Twenty QT grafts were harvested from 10 embalmed human cadaver specimens. 10 were prepared with the PK and 10 with the NK using a No.2 FiberWire (Arthrex, Naples, FL). The prepared grafts were then mounted in a materials testing machine (ElectroPuls E10000, Instron, Norwood, MA) and subjected to tensile loading based on an established protocol. Each tendon-suture specimen was preconditioned with 3 cycles of 0–100N at 1Hz followed by a constant load of 50N for 1 minute and cyclic loading of 200 cycles from 50–200N at 1Hz and then loaded to failure at a displacement rate of 20mm/min. Load and displacement data for each tendon-suture construct was recorded by the testing machine.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 32 - 32
1 Mar 2021
Lapner P McRae S Leiter J McIlquham K MacDonald P
Full Access

Controversy exists regarding the optimal technique for arthroscopic rotator cuff repair. No previous comparative trials have reported on the long-term follow-up of single and double row fixation in arthroscopic cuff repair. The purpose of this study was to compare the long-term functional outcomes of single-row and double-row suture techniques for repair of the rotator cuff 10-years post-operatively.

Ninety patients undergoing arthroscopic rotator cuff repair were randomized to receive either single-row or double-row repair. The primary objective was to compare the Western Ontario Rotator Cuff Index (WORC) score 10-years post-operatively. Secondary objectives included comparison of the Constant, and American Shoulder and Elbow Surgeons (ASES) scores and supraspinatus strength between groups. Out of 90 patients originally randomized, 57 returned for the long-term 10-year follow-up.

Baseline demographic data did not differ between groups. The WORC score was not significantly different between groups at long-term follow-up (p=0.13). No statistical differences were observed between groups for the Constant (p=0.51), ASES (p=0.48) scores, or strength scores (p=0.93). A significant improvement was observed between pre-operative and the final 10-year follow-up. There were no differences observed in all outcomes between two and 10-years post-operatively.

No statistically significant differences in functional or quality of life outcomes were identified between single-row and double-row fixation techniques at long-term follow-up.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 51 - 51
1 Mar 2021
Larose G McRae S Beaudoin A McCormack R MacDonald P
Full Access

There is increasing evidence that patients with ACL reconstruction using ipsilateral graft harvest are at greater risk of rupture (12.5%) on their contralateral compared to their surgical side (7.9%). The purpose of this study is to re-evaluate patients from a previous study comparing ipsi- versus contralateral graft harvest to compare ACL rupture rate at a minimum 10 year follow-up.

An attempt to contact all participants from a previously published study was made to invite them to return for a follow-up. The assessment included an International Knee Documentation Committee Knee Clinical Assessment (IKDC), isokinetic concentric knee flexion and extension strength testing, as well as the ACL-Quality of life (ACL-QOL). A chart review was conducted to identify or confirm subsequent ipsi- or contralateral knee surgeries.

In patients with ipsilateral graft, 3/34 (8.8%) re-ruptured and 3/34 (8.8%) had contralateral rupture. In the contralateral group, 1/28 (3.6%) re-ruptured and 2/28 (7.1%) had contralateral rupture. The relative risk (RR) of re-rupture with ipsilateral graft was 2.47 compared to using the contralateral site (p=0.42). RR of rupture on the contralateral side when ipsilateral graft was used was 1.23 compared to the alternate approach. Current contact information was unavailable for 21 patients. Of the 47 remaining, 37 were consented (79%). No difference in the ACL-QOL between groups (ipsilateral 68.4±24.4, contralateral 80.1±16.0, p=0.17) was observed. There were no differences in knee flexion strength between groups (peak torque flexion affected leg: ipsilateral 77.8nm/kg±27.4, contralateral: 90.0 nm/kg±35.1; p=0.32; Unaffected leg: ipsilateral: 83.3 nm/kg±30.2 contralateral 81.7 nm/kg±24.4; p= 0.89).

This study suggests that using the contralateral hamstring in ACL rupture is not associated with an increase in ACL rupture on either side. The risk of ACL injury was low in all limbs; therefore, a larger study would be required to definitively state that graft side had no impact.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 26 - 26
1 Mar 2021
Malik S Hart D Parashin S Malik S McRae S MacDonald P
Full Access

Abstract

Objectives

To evaluate mechanical properties of three suture-tendon constructs, the Krackow stitch (KS), the modified Prusik knot (PK) and the Locking SpeedWhip (LSW), using human cadaveric quadriceps grafts (QT).

Methods

Thirty QT grafts were obtained from human cadaver specimens and an equal number of tendon-suture constructs were prepared for three stitches: KS, PK and LSW. The constructs were mounted in a materials testing machine (ElectroPuls E10000, Instron, Norwood, MA) and subject to tensile loading based on an established protocol. Load and displacement data for each tendon-suture construct were recorded.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 33 - 33
1 Mar 2021
Woodmass J McRae S Malik S Dubberley J Marsh J Old J Stranges G Leiter J MacDonald P
Full Access

When compared to magnetic resonance imaging (MRI), ultrasound (US) performed by experienced users is an inexpensive tool that has good sensitivity and specificity for diagnosing rotator cuff (RC) tears. However, many practitioners are now utilizing in-office US with little to no formal training as an adjunct to clinical evaluation in the management of RC pathology. The purpose of our study was to determine if US without formal training is effective in managing patients with a suspected RC tear.

This was a single centre prospective observational study. Five fellowship-trained surgeons each examined 50 participants referred for a suspected RC tear (n= 250). Patients were screened prior to the consultation and were included if ≥ 40 years old, had an MRI of their affected shoulder, had failed conservative treatment of at least 6 months, and had ongoing pain and disability. Patients were excluded if they had glenohumeral instability, evidence of major joint trauma, or osteonecrosis. After routine clinical exam, surgeons recorded their treatment plan (“No Surgery”, “Uncertain”, or “Surgery”). Surgeons then performed an in-office diagnostic US followed by an MRI and documented their treatment plan after each imaging study. Interrater reliability was analyzed using a kappa statistic to compare clinical to ultrasound findings and ultrasound findings to MRI, normal and abnormal categorization of biceps, supraspinatus, and subscapularis.

Following clinical assessment, the treatment plan was recorded as “No Surgery” in 90 (36%), “Uncertain” in 96 (39%) of cases, “Surgery” in 61 (25%) cases, and incomplete in 3 (2%). In-office US allowed resolution of 68 (71%) of uncertain cases with 227 (88%) of patients having a definitive treatment plan. No patients in the “No Surgery” group had a change in treatment plan. After MRI, 16 (6%) patients in the “No Surgery” crossed-over to the “Surgery” group after identification of full-thickness tears, larger than expected tears or alternate pathology (e.g., labral tear).

The combination of clinical examination and in-office US may be an effective method in the initial management of patients with suspected rotator cuff pathology. Using this method, a definitive diagnosis and treatment plan was established in 88% of patients with the remaining 12% requiring an MRI. A small percentage (6%) of patients with larger than expected full-thickness rotator cuff tears and/or alternate glenohumeral pathology (e.g., labral tear) would be missed at initial evaluation.


Abstract

Objectives

Initial performance of sutured quadriceps tendon (QT) ACL graft constructs is not well studied in human tissue and the results of animal tissue testing may not extend to the human model. Two common methods of preserving human tissue are to freeze the specimens immediately after death or embalm with formalin solution. The purpose of this study is to compare elongations and loads in biomechanical testing of fresh-frozen to that of embalmed quadriceps tendon-suture constructs.

Methods

Twenty QT grafts were harvested from human cadaver specimens, 10 fresh-frozen and 10 embalmed. The grafts were prepared with the modified Prusik knot using a No.2 FiberWire (Arthrex, Naples, FL), mounted in a materials testing machine (ElectroPuls E10000, Instron, Norwood, MA) and subjected to tensile loading based on an established protocol. Each tendon was preconditioned with 3 cycles of 0–100N at 1Hz followed by a constant load of 50N for 1 minute and 200 cycles from 50–200N at 1Hz and then loaded to failure at a displacement rate of 20mm/min. Load and displacement data for each tendon-suture construct was recorded.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 34 - 34
1 Mar 2021
MacDonald P Woodmass J McRae S Verhulst F Lapner P
Full Access

Management of the pathologic long-head biceps tendon remains controversial. Biceps tenotomy is a simple intervention but may result in visible deformity and subjective cramping. Comparatively, biceps tenodesis is technically challenging, and has increased operative times, and a more prolonged recovery. The purpose of this study was to determine the incidence of popeye deformity following biceps tenotomy versus tenodesis, identify predictors for developing a deformity, and compare subjective and objective outcomes between those that have one and those that do not.

Data for this study were collected as part of a randomized clinical trial comparing tenodesis versus tenotomy in the treatment of lesions of the long head of biceps tendon. Patients 18 years of age or older with an arthroscopy confirmed biceps lesion were randomized to one of these two techniques. The primary outcome measure for this sub-study was the rate of a popeye deformity at 24-months post-operative as determined by an evaluator blinded to group allocation. Secondary outcomes were patient reported presence/absence of a popeye deformity, satisfaction with the appearance of their arm, as well as pain and cramping on a VAS. Isometric elbow flexion and supination strength were also measured. Interrater reliability (Cohen's kappa) was calculated between patient and evaluator on the presence of a deformity, and logistic regression was used to identify predictors of its occurrence. Linear regression was performed to identify if age, gender, or BMI were predictive of satisfaction in appearance if a deformity was present.

Fifty-six participants were randomly assigned to each group of which 42 in the tenodesis group and 45 in the tenotomy group completed a 24-month follow-up. The incidence of popeye deformity was 9.5% (4/42) in the tenodesis group and 33% (15/45) in the tenotomy group (18 male, 1 female) with a relative risk of 3.5 (p=0.016). There was strong interrater agreement between evaluator and patient perceived deformity (kappa=0.636; p<0.001). Gender tended towards being a significant predictor of having a popeye with males having 6.6 greater odds (p=0.090). BMI also tended towards significance with lower BMI predictive of popeye deformity (OR 1.21; p=0.051). Age was not predictive (p=0.191). Mean (SD) satisfaction score regarding the appearance of their popeye deformity was 7.3 (2.6). Age was a significant predictor, with lower age associated with decreased satisfaction (F=14.951, adjusted r2=0.582, p=0.004), but there was no association with gender (p=0.083) or BMI (p=0.949). There were no differences in pain, cramping, or strength between those who had a popeye deformity and those who did not.

The risk of developing a popeye deformity was 3.5 times higher after tenotomy compared to tenodesis. Male gender and lower BMI tended towards being predictive of having a deformity; however, those with a high BMI may have had popeye deformities that were not as visually apparent to an examiner as those with a lower BMI. Younger patients were significantly less satisfied with a deformity despite no difference in functional outcomes at 24 months. Thus, biceps tenodesis may be favored in younger patients with low BMI to mitigate the risk of an unsatisfactory popeye deformity.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 83 - 83
1 Nov 2016
Saithna A Longo A Leiter J MacDonald P Old J
Full Access

Recent literature has demonstrated that conventional arthroscopic techniques do not adequately visualise areas of predilection of pathology of the long head of biceps (LHB) tendon and are associated with a 30–50% rate of missed diagnoses. The aim of this study was to evaluate the safety, effectiveness and ease of performing biceps tenoscopy as a novel strategy for reducing the rate of missed diagnoses.

Five forequarter amputation cadaver specimens were studied. The pressure in the anterior compartment was measured before and after surgical evaluation. Diagnostic glenohumeral arthroscopy was performed and the biceps tendon was tagged to mark the maximum length visualised by pulling the tendon into the joint. Biceps tenoscopy was performed using 3 different techniques (1. Flexible video-endoscopy, 2. Standard arthroscopy via Neviaser portal. 3. Standard arthroscope via antero-superior portal with retrograde instrumentation). Each was assessed for safety, ease of the procedure and whether the full length of the extra-articular part of the LHB tendon could be visualised. The t-test was used to compare the length of the LHB tendon visualised at standard glenohumeral arthroscopy vs that visualised at biceps tenoscopy. An open dissection was performed after the arthroscopic procedures to evaluate for an iatrogenic injury to local structures.

Biceps tenoscopy allowed visualisation to the musculotendinous junction in all cases. The mean length of the tendon visualised was therefore significantly greater at biceps tenoscopy (104 mm) than at standard glenohumeral arthroscopy (33 mm) (mean difference 71 mm, p<0.0001). Biceps tenoscopy was safe with regards to compartment syndrome and there was no difference between pre- and post-operative pressure measurements (mean difference 0 mmHg, p=1). No iatrogenic injuries were identified at open dissection.

Biceps tenoscopy allows excellent visualisation of the entire length of the LHB tendon and therefore has the potential to reduce the rate of missed diagnoses. This study did not demonstrate any risk of iatrogenic injury to important local structures or any risk of compartment syndrome. Clinical evaluation is required to further validate this technique.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 80 - 80
1 Nov 2016
Saithna A Longo A Leiter J MacDonald P Old J
Full Access

The majority of studies reporting sensitivity and specificity data for imaging modalities and physical examination tests for long head of biceps (LHB) tendon pathology use arthroscopy as the gold standard. However, there is little published data to validate this as an appropriate benchmark. The aim of this study was to determine the maximum length of the LHB tendon that can be seen at glenohumeral arthroscopy and whether it allows adequate visualisation of common sites of pathology.

Seven female cadaveric specimens were studied. Mean age was 74 years (range 44–96 years). Each specimen underwent arthroscopy in lateral decubitus (LD) and beach chair (BC) positions. The LBH-tendon was tagged with a suture placed with a spinal needle marking the intra-articular length and the maximum excursions achieved using a hook and a grasper in both LD and BC positions. T-tests were used to compare data.

The mean intra-articular and extra-articular lengths of the tendon were 23.9 mm and 82.3 mm respectively. The mean length of tendon that could be visualised by pulling it into the joint with a hook was significantly less than with a grasper (LD: hook 29.9 mm, grasper 33.9 mm, mean difference 4 mm, p=0.0032. BC: hook 32.7 mm, grasper 37.6 mm, mean difference 4.9 mm, p=0.0001). Using the BC position allowed visualisation of a significantly greater length than the LD position when using either a hook (mean difference 2.86 mm, p=0.0327) or a grasper (mean difference 3.7 mm, p=0.0077). The mean length of the extra-articular part of the tendon visualised using a hook was 6 mm in LD and 8.9 mm in BC. The maximum length of the extra-articular portion visualised using this technique was 14 mm (17%).

Pulling the tendon into the joint with a hook does not allow adequate visualisation of common distal sites of pathology in either LD or BC. Although the BC position allows a significantly greater proportion of the tendon to be visualised this represents a numerically small value and is not likely to be clinically significant. The use of a grasper also allowed greater excursion but results in iatrogenic tendon injury which precludes its use. The reported incidence of pathology in Denard zone C (distal to subscapularis) is 80% and in our study it was not possible to evaluate this zone even by using a grasper or maximum manual force to increase excursion. This is consistent with the extremely high rate of missed diagnoses reported in the literature. Surgeons should be aware that the technique of pulling the LHB-tendon into the joint is inadequate for visualising distal pathology and results in a high rate of missed diagnoses. Furthermore, efforts to achieve greater excursion by “optimum” limb positioning intra-operatively do not confer an important clinical advantage and are probably unnecessary.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 227 - 227
1 May 2009
MacDonald P Lapner P Leiter J Mascarenhas R McRae S
Full Access

The purpose of this prospective randomised clinical trial is to examine the effect of acromioplasty on the outcome of arthroscopic rotator cuff repair.

Patients included individuals that were referred for assessment after six months of failed conservative management. Following informed consent patients were randomly assigned to receive arthroscopic rotator cuff repair with or without acromioplasty. The surgeon was not blinded to the type of procedure; however, the researcher who performed the follow-up evaluations and the patient was blinded to the surgical protocol. Subacromial decompression (acromioplasty) was performed with release of the coracoacromial ligament off the anterior undersurface of the acromion. The procedure for arthroscopic cuff repair without acromioplasty followed the protocol of arthroscopic cuff repair with acromioplasty, without division of the coracoacromial ligament or resection of the acromion. Both groups experienced the same post-operative rehabilitation protocol. Wound healing and active and passive range of motion were assessed and recorded at six to eight weeks post-operatively. Subsequent post-operative visits occurred at three, six, twelve, eighteen and twenty-four months and included documentation of patient range of motion, patient derived WORC scores (1) and complete ASES scores.

Preliminary results suggest, based on a one-tailed t-test, patients that receive a rotator cuff repair with acromioplasty demonstrate a statistically significant improvement (< 0.05) in Quality of Life, based on WORC and ASES scores, compared to the non-acromioplasty group. To date, three patients in the non-acromioplasty group required a revision surgery; two of these patients had a Type III acromion.

Arthroscopic rotator cuff repair with arthroscopic acromioplasty in the treatment of full thickness rotator cuff tears is recommended for patients with a Type III acromion.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 60 - 61
1 Mar 2008
Arneja S Froese W MacDonald P
Full Access

Thirty- seven patients were enrolled in a single-blind prospective randomized clinical trial comparing the use of the Endopearl in femoral fixation in otherwise similar anterior cruciate ligament (ACL) reconstructions. Evaluation pre-operatively, three months, six months and eighteen months post-operatively suggested significant difference in the side to side KT-1000 values suggesting improved graft fixation with the EndoPearl by eighteen months post surgery with no differences in the Mohtadi ACL QOL questionnaire. Thus, when bioabsorbable interference screws are used for ACL reconstruction, the use of the EndoPearl improves anterior-posterior stability up to eighteen months post-operatively.

The EndoPearl is an adjunct to bioabsorbable interference screw fixation in the femoral tunnel in ACL reconstruction. The purpose of the study was to assess the clinical effectiveness of the EndoPearl using the KT-1000 Knee Arthrometer and the Mohtadi ACL Quality of Life (ACL-QOL) Questionnaire.

The application of the EndoPearl in hamstring ACL reconstruction has no significant benefit when compared to conventional treatment in KT-1000 and ACL-QOL Questionnaire outcomes.

Prospective Single-blind Randomized Clinical Trial. ACL reconstruction with autogenous semitendino-sus and gracilis tendons was performed on thirty-seven patients. Pre-operatively, three months, six months and a eighteen months post-operatively, patients’ knees were evaluated using the KT-1000 Knee Arthrometer and the ACL-QOL questionnaire.

Statistically significant differences were achieved in terms of KT-1000 side-to-side differences between the study group and the control group at six months and eighteen months post-operatively; the mean-side-to-side differences are significantly less in the study group when compared to the control group. Statistically significant differences could not be detected when comparing the ACL-QOL questionnaire between the two groups.

The application of the EndoPearl in conjunction with a bioscrew in the femoral tunnel in autogenous ACL reconstruction using semitendinosus and gracilis tendon grafts provides a significantly decreased laxity up to eighteen months post-operatively in terms of KT-1000 side-to-side differences.

In an accelerated post-operative rehabilitation program, patients and doctors have increased confidence in terms of graft stability with the application of the Endo-Pearl in hamstring ACL reconstruction.

Please contact author for pictures and/or diagrams.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 152 - 152
1 Mar 2008
MacDonald P Rodwan K Dion A
Full Access

Purpose: To describe functional results following revision ACL reconstruction surgery.

Methods: Patients more than 2 years post-operative from revision ACL surgery by the same surgeon were asked to participate. Patient-based evaluation was determined by ACL Quality of Life(QOL) and Lysholm scores while clinical evaluation was based on IKDC and KT1000 Arthrometer scoring. Surgical information and radiographs were reviewed to identify associated pathologies and surgical technique.

Results: Of 18 eligible patients, 15 were available for review(10 male, 5 female). Average age was 29 years(24–52); average follow-up time was 45.6 months(24–120). Primary ACL reconstructions failed due to surgical technique in 3 patients(20%), while trauma led to failure in 11 patients (73%). One patient failed due to previously unrecognized posterolateral instability and required an osteotomy at revision surgery. During revision surgery, 12 patients received a hamstring graft (10 contralateral, 2 ipsilateral) and 3 patients received a tibial posterior allograft. The most frequent concomitant procedures were a partial medial meniscectomy(3) and chondroplasty (5). Based on latest follow-ups, 7 patients had +2 grade on Lachman’s test, 4 patients had +1 grade and 4 patients had a negative grade. IKDC evaluation classified 3 patients as ‘normal’, 4 as ‘nearly normal’, 3 as ‘abnormal’ and 1 as ‘severely abnormal’. Autograft patients had a mean side-to-side difference of 2.8mm while allograft patients had a mean difference of 4.5 mm. Patient-rated Lysholm scores indicated that 4 patients received a ‘good’ score (84–94), 5 patients a ‘fair’ score (65–83) and 3 patients a ‘poor’ score (0–64). The average QOL score was 58.2%(12–96%). Patients characterized as having poor clinical and patient-rated results also had significant articular lesions identified during surgery.

Conclusions: Results of revision surgery do not appear to be as good as previously published reports of primary reconstructions. Consideration must be given to the status of the articular cartilage, as it appears to be an important factor in determining the overall functional result.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 120 - 120
1 Mar 2008
MacDonald P Chahal J Berard H Kassiri K Dyck M
Full Access

Expert North American shoulder surgeons were poled on the diagnosis and treatment of five shoulder conditions. To quantify inter-observer agreement in the diagnosis and treatment of shoulder instabilities, they chose one of five diagnostic conditions and one or more of seven treatment options. The greatest diagnostic and treatment differences were noted for a painful shoulder in a throwing athlete with subtle anterior instability and a patient with voluntary posterior instability with an asymptomatic sulcus sign. An arthroscopic approach was consistently preferred to open surgery. These inconsistencies highlight the need for standardized diagnostic criteria and more universal treatment plans.

To quantify inter-observer agreement in the diagnosis and treatment of shoulder instabilities among expert North American shoulder surgeons.

These inconsistencies, particularly in diagnosis, highlight the need for standardization of diagnostic criteria and guidelines working towards more universal treatments and evaluations of outcomes.

The greatest diagnostic differences were noted for a painful shoulder in a throwing athlete with subtle anterior instability(Ksc0.46, 55% agreement) and a patient with voluntary posterior instability with an asymptomatic sulcus sign(Ksc0.41, 50% agreement). The presence of an asymptomatic sulcus sign alone may have been mistakenly interpreted as inferior instability rather than inferior laxity. There was a high level of agreement in diagnosing anterior and bi-directional instability. An arthroscopic approach to treatment was consistently preferred to open surgery. The greatest differences in treatment choice were for the throwing athlete(Ksc0.38, 47% agreement on arthroscopic repair), a patient with voluntary posterior instability(Ksc0.34, 43% agreement on arthroscopic capsular repair) and a patient with bi-directional instability(Ksc0.23, 34% agreement on arthroscopic anterior Bankart repair).

Active members of the American Shoulder and Elbow Surgeons and JOINTS Canada (Orthopaedic Initiatives for National Trials of the Shoulder) were poled on the diagnosis and treatment of five shoulder conditions. They were to choose one of five conditions and one or more of seven treatment options. A Kappa coefficient of agreement was used to assess inter-observer reliability; a Ksc of 1 denotes perfect agreement on a category and a Ksc of −1 denotes perfect agreement on not endorsing a category.