Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 34 - 34
1 Mar 2012
Ferguson J Pandit H Price A Marks B Gill H Murray D Dodd C
Full Access

Introduction

Obesity has been considered a relative contra-indication in unicompartmental knee arthroplasty (UKA) due to fear of high wear rates, loosening and tibial collapse. The aim of this study was to investigate the impact of high body mass index (BMI) on ten-year survivorship and five-year functional outcome after Oxford UKA, a fully congruous mobile bearing design with large contact area and low wear rate.

Methods

This prospective study examines a consecutive series of 595 knees (mean age 66 years, range: 33-88) undergoing Oxford UKA with a minimum 5-year follow-up. Patients were divided into three groups; Group I (Normal body weight), BMI <25 (n=171), Group II (overweight), BMI 25- 30 (n=264), and Group III (Obese), BMI ≥30 (n=160). The survivorship and functional outcome (as assessed by change in Oxford Knee Score [DeltaOKS]) and Knee Society Score (KSS) for all three groups were compared.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 411 - 411
1 Jul 2010
Kendrick BJL Simpson D Bottomley NJ Marks B Pandit H Beard D Gill HS Dodd CA Murray DW Price AJ
Full Access

Purpose: This study was designed to establish the poly-ethylene wear rates in the Oxford medial unicompert-mental knee replacement.

Introduction: The Oxford meniscal bearing knee was introduced as a design to reduce polyethylene wear. There has been one previous retrieval study of the Oxford UKA, which reported very low wear rates in some specimens, but abnormal patterns of wear in others, including impingement. There has been no further investigation of these abnormal wear patterns.

Methods: Forty-seven bearings were retrieved from patients who had received a medial Oxford UKA for anteromedial osteoarthritis of the knee, none of which had previously been studied. Mean time to revision was 8.4 years (SD 4.1) and 20 had been implanted for over 10 years. The macroscopic pattern of polyethylene wear and the linear penetration (dial gauge measurement) was recorded for each bearing.

Results: The mean linear penetration rate (LPR) was 0.07mm/year. The patterns of wear fell into 4 categories, each with a different LPR; 1) No abnormal macroscopic appearance, n=16 (LPR = 0.01mm/year), 2) Abnormal macroscopic wear with extra-articular impingement, n=16 (LPR = 0.05mm/year), 3) Abnormal macroscopic wear with intra-articular impingement, n=6 (LPR = 0.10mm/year), 4) Abnormal macroscopic wear with impingement and signs of incongruous articulation, n=9 (LPR = 0.14mm/year). The differences in LPR were statistically significant (p< 0.05).

Conclusion: The results show that very low polyethylene wear rates are possible if the device functions normally. However if the bearing displays abnormal function (extra-articular, intra-articular impingement or incongruous articulation) wear rates increase significantly.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 274 - 274
1 May 2010
Pandit H Steffen R Gundle R Mclardy-Smith P Marks B Beard D Gill H Murray D
Full Access

Introduction: Although resurfacing hip replacements are widely used there are few little independent outcome data to support this. The aim of this study was to report the 5 year clinical outcome and 7 year survival of an independent series.

Method: 610 Birmingham hip resurfacings were implanted in 532 patients with an average age of 51.8 years (range 16.5–81.6 years) and were followed for between 2 to 8 years; 120 of this series had minimum five year follow-up. Two patients were lost. There were 23 revisions, giving an overall survival of 95% (95% CI 85–99%) at seven years. Fractured neck of femur (n=13) was the most common reason for revision, followed by aseptic loosening (n=4). There were also 3 patients who had failures that were possibly related to metal debris. At a minimum of 5 year follow-up 93% had excellent or good outcome according to the Harris Hip Score. The mean Oxford Hip Score was 16.1 points (SD 7.7) and the mean UCLA activity score was 6.6 points (SD 1.9). There were no patients with definite evidence of radiographic loosening or greater than 10% of neck narrowing.

Discussion: The results demonstrate that with the Birmingham Hip Resurfacing, implanted using the extended posterior approach, the five year survival is similar or better to the reported survival rates for cemented and hybrid THR’s in young patients.

Conclusions: Considering these patients are young and active these results are good and support the use of resurfacing. However, further study is needed to address the early failures; particularly those related to fracture and metal debris.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 412 - 412
1 Sep 2009
Pandit H Jenkins C Gill H Beard D Marks B Price A Dodd C Murray D
Full Access

Introduction: The results of the mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing with a five year survival of 82%. Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to high dislocation rate, all occurring in the first year. A detailed analysis of the causes of bearing dislocation confirmed the elevated lateral tibial joint line to be a contributory factor. A new surgical technique was therefore introduced in which care was taken neither to remove too much bone from the distal femur nor to over tighten the knee and therefore ensure that the tibial joint line was not elevated. Other modifications to the technique were also introduced including use of a domed tibial component.

Aim: The aim of this study is to compare the outcome of these iterations: the original series [series I], Series II with improved surgical technique and the domed tibial component [Series III].

Method: The primary assessment of outcome was bearing dislocation at one year. One year was chosen as all the dislocations in the first series occurred within a year. In series I, there were 53 knees, in series II 65 knees and in series III 60 knees, all with a minimum of one year follow up.

Results: In series I, there were 6 bearing dislocations (11%) and the average range of movement (ROM) was 110°. In the second series, there were 2 dislocations (3%) and the average ROM was 118°. In the third series, there were no primary dislocations and the average ROM was 125°.

Conclusions: The improved surgical technique and implant design has reduced the dislocation rate to an acceptable level so a mobile bearing can now be recommended for lateral UKR.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 412 - 412
1 Sep 2009
Pandit H Jenkins C Beard D Gill H Marks B Price A Dodd C Murray D
Full Access

Introduction: The information in the literature about the relative merits of cemented and cementless unicompartmental knee replacement (UKR) is contradictory, with some favouring cementless fixation while others favouring cemented fixation. Cemented fixations give good survivorship but there is concern about the radiolucency which frequently develops around the tibial component. The exact cause of the occurrence of radiolucency is unknown but according to some, it may suggest suboptimal fixation.

Method: Sixty-two knees (31 in each group) were randomised to receive either cemented or cementless UKR components. The components were similar except that the cementless had a porous titanium and hydroxyappatite (HA) coating. Patients were prospectively assessed by an independent observer pre-operatively and annually thereafter. The clinical assessment included Oxford Knee Score, Knee Society Scores and Tegner activity score. Fluoroscopically aligned radiographs were assessed for thickness and extent of radiolucency under the tibial implant.

Results: At one year there were no differences in the clinical outcome between the groups and there were no loose components. No radiolucencies thicker than 1mm were seen. At one year none of the cementless tibias and 30% of the cemented tibias had complete radiolucencies. One out of 31 cementless (3%) and 12 out of 31 cemented (39%) had partial radiolucencies. This difference between these two groups was high significant (p< 0 0001).

Conclusions: This study clearly demonstrates that the incidence of radiolucency beneath the tibial component is influenced by component design and method of fixation. With identical designs of tibial component none of the cementless components developed complete radiolucences whereas 30% of the cemented components did. We conclude that HA achieves better bone integration than cement.