Cementless distally locked stems were introduced in revision hip arthroplasty (RTHA) in the late 1980s to deal with severe femoral bone loss. These implants have not been assessed over the long-term, particularly the influence of the design and porous coating. Therefore we performed a retrospective case-control study at a minimum 10-years' follow-up comparing the straight Ultime™ stem with 1/3 porous coating versus the anatomical Linea™ stem with 2/3 proximal coating with hydroxyapatite. We performed a single-center case-control study measuring survival, function based the Harris and Oxford-12 scores, and rate of thigh pain. X-rays were done at regular intervals and at follow-up. No femoral bone graft was used at insertion. The two groups were comparable in terms of age, sex and follow-up (mean 12.2 years in Ultime and 10.8 years in Linea cohorts); however they differed in the severity of bone loss therefore the results were adjusted according to this variable. Ten-year survival considering revision for any reason was 63.5% ± 5.4 for Ultime and 91.6% ± 2.7 for Linea (p < 0.001). Merle d'Aubigné scores and Oxford-12 were higher in the Linea group 82.9 ± 12.4 and 26.3/48, respectively, versus 69.5 ± 16 and 21/48 in the Ultime group (p < 0.001). Thigh pain was observed in 30% of Ultime cases versus 3% of Linea cases. Bone reconstruction measured via cortical thickness was better in the Linea group and correlated to metaphyseal filling at insertion. This study confirms the benefits of using of locked stems in RTHA with severe bone loss. Better metaphyseal filling and optimized porous coating help to minimize thigh pain and the revision rate.
In valgus knees, ligament balance remain difficult when implanting a total knee arthroplasty (TKA), this leads some authors to systematically propose the use of constrained devices. Others prefer reserving higher constraints to cases where it is not possible to obtain final satisfactory balance: less than 5 of residual frontal laxity in extension in each compartment, and a tibiofemoral gap difference not in excess to 3mm between flexion and extension. The goal of the study was to assess if is possible to establish preoperative criteria that can predict a constrained design prosthetic implantation at surgery. A consecutive series of 93 total knee prostheses, implanted to treat a valgus deformity of more than 5 was retrospectively analysed. Preoperatively, full weight bearing long axis AP views A-P were performed: hip knee angle (HKA) averaged 195 (186 to 226), 36 knees had more than 15 of valgus, and 19 others more than 20 of valgus. Laxity was measured by stress radiographies with a TelosTM system at 100 N. Fifty-two knees had preoperative laxity in the coronal plane of more than 10. Fourteen knees had more than 5 laxity on the convex (medial) side, 21 knees had more than 10 laxity on the concave (lateral) side. Statistical assessment, using univariate analysis, identified the factors that led, at surgery, to an elevated constraint selection level; these factors of independence were tested by multivariate analysis. Logistical regression permitted the classification of the said factors by their odds ratios (OR).Introduction
Materials and Methods