Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 38 - 38
1 Mar 2021
Nikolaou V Floros T Sourlas I Pappa E Kaseta M Babis G
Full Access

This study aims to investigate that a single dose of tranexamic acid (TXA) will reduce blood loss and transfusion rates in elderly patients, undergoing intertrochanteric (IT) or femoral neck fractures surgery. Consecutive elderly patients receiving hip fracture surgery for stable or unstable IT fracture, treated with short intramedullary nail (IMN) insertion as well as cemented hemiarthroplasty for acute femoral neck (subcapital) hip fracture, were screened for inclusion in this single-centre randomized trial.

Patients were randomly allocated to a study group by sealed envelope. One TXA dose of 15 mg/kg i.v. diluted in 100 ml N/S or one placebo dose i.v. in 100 ml N/S were administered 5 mins before the skin cut. Haemoglobin (Hb) concentration was measured at admission time and prior to surgery. Post-operatively it was measured on a daily basis until day 4, giving a total of four Hb measurements (days 1 to 4). The transfusion trigger point was determined in accordance with the French guidelines for erythrocyte blood transfusion. The transfusion trigger was 10 g/dl for patients at risk, while in all other cases, it was 9 g/dl. Information regarding the transfusions number was assessed directly by the hospital blood bank database. Blood loss was calculated by the Hb dilution method. Nadler's formula was used to calculate patients' blood volume. For calculation of total blood loss (TBL) expressed to total Hb loss and total Volume loss, the number of transfusions (55 grams of Hb per transfusion), the Hb concentration on preoperatively (Hgbi) and the Hb concentration on the last measure (Hgbe) were used. (Hb balance method).

The primary efficacy outcome was the number of transfusions of allogeneic RBC from surgery up to day 4. The secondary ones were the total blood loss from surgery to day 4 as it was calculated by Hb-balance method. After randomization, 35 patients with femoral neck fracture and 30 patients with IT fracture received TXA prior to surgery. Respectively, 30 patients with femoral neck fracture and 55 with IT fracture didn't receive TXA. The groups did not differ significantly in their basic demographics (age, gender, BMI, injury mechanism, ASA score, co-morbidities). Results showed that patients undergoing hemiarthroplasty after receiving TXA, were transfused with less allogeneic RBC and had less total blood loss than patients that didn't receive TXA, but without statistical significance. While patients treated with IMN in the TXA group received a significantly lower number of RBC units than the control group (1.28 ± 1.049 vs 2.075 ± 1.685), (P = 0.0396), had a significantly lower loss of Hb (98.59 ± 55.24 vs 161.6 ± 141.7), (P = 0.0195) and a lower total blood volume loss (951.3 ± 598.9 ml vs 1513 ± 1247 ml), (P = 0.023).

This trial confirmed TXA administration efficacy in reducing blood loss and transfusion rate in elderly patients undergoing hip fracture surgery. A TXA single dose may be a safer option, taking into account these patients' physiological status and co-morbidities.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 2 - 2
1 May 2017
Malahias M Nikolaou V Sourlas I Chytas D Chrysikopoulos K Babis G
Full Access

Background

We searched -in transverse ultrasound view- the value of the difference (Delta) between -proximal to the tunnel- CSA (a) and -in the tunnel's inlet- CSA (b) for separating normal from abnormal median nerves.

Methods

51 patients –suspicious for CTS- underwent Phalen and Tinnel tests. After that, we used a high frequency ultrasound to measure CSAa, CSAb and Delta CSA in both hands. 33 of our 51 patients did not experience any clinical symptoms at the contralateral hand, so that we could perform a comparative study of normal and pathological median nerves (on the same patients). Then, all of them completed a Q-DASH questionnaire and a visual analogue scale (VAS 100/100) and they carried through with a nerve conduction study (NCS).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 42 - 42
1 May 2017
Malahais MA Babis G Johnson E Kaseta M Chytas D Nikolaou V
Full Access

Background

To investigate the new theory of hydroneurolysis and hydrodissection in the treatment of carpal tunnel syndrome (CTS). Independently of the fluid hydrodissolution works due to mechanical forces and it may have some positive effects in patients with ischemic damage caused by scar tissue pressure at the nerve's surface.

Methods

A prospective blind clinical study of 31 patients suffering from carpal tunnel syndrome, established by nerve conduction studies and clinical tests. 14 patients (out of 29), who refused to undergo an open operation as a treatment to their disease at this point of time, were treated with a simple ultrasound-guided injection at the proximal carpal tunnel. In order to exclude the biochemical influence of the fluid in the treating disease we choosed to infiltrate 3 cc. of normal saline 0,9%. In the follow-up period our group was asked to answer to a new Q-DASH score and visual analogue scale (VAS) 100/100 in 2, 4 and 8 weeks.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 29 - 29
1 May 2017
Malahias M Babis G Kaseta M Chytas D Kazas S Nikolaou V
Full Access

Introduction

We compared ultrasound guided methylprednizolone-lidacaine infiltrations around inflammatory area of plantar aponeurosis with systematic use of NSAID'S. Also, we investigated the reliability of the sonographic criteria (a. swelling of aponeurosis more than 20% in comparison to the healthy foot, b. effusion around aponeurosis, c. calcium deposits) most used to identify plantar fasciitis in clinically suspicious patients.

Methods

A prospective randomised controlled clinical trial, including 28 patients (mean age: 47 years, range: 36–65 years, 85% females) with typical clinical symptoms of plantar fasciitis. All of these patients undertook a soft tissue ultrasonography of the plantar aponeurosis, without Doppler. Then, we randomly divided our sample in 2 groups, group A (14 patients) and group B (14 patients). In group A patients we performed an ultrasound guided injection –in transverse view- around the swollen part of aponeurosis, while we managed group B patients with per os NSAID's treatment (meloxicam 15 mg, once per day) for 2 weeks.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 30 - 30
1 May 2017
Malahias M Babis G Kaseta M Chronopoulos E Fandridis E Nikolaou V
Full Access

Background

To determine if double needle ultrasound-guided hydrodissolution and aspiration of intratendinous calcification is more effective treatment than blind subacromial corticosteroid injection.

Methods

A prospective randomised comparative clinical study of 32 patients suffering from chronic symptomatic calcific tendinosis of the supraspinatous tendon. Group A (16 patients) received a double needle ultrasound-guided aspiration of the calcification, while group B (16 patients) underwent a blind subacromial betamethazone injection. As far as group A, we attached a syringe in the first needle, including 10cc. of normal saline (N/S), that we injected targeting the calcium deposit. Then we tried to achieve consecutive aspirations through the second needle.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 45 - 45
1 May 2017
Nikolaou V Chytas D Malahias M Babis G
Full Access

Background

The economic crisis has significantly altered the quality of life in Greece. The obvious negative impact on the offered social and health services has been adequately analysed. We aimed to determine whether the economic crisis has influenced the quantity and quality of Orthopaedic research in Greece, as mirrored from the papers presented at the annual meetings of Hellenic Association of Orthopaedic Surgery between the years 2008–2014.

Methods

The abstracts of the papers (oral and posters) presented in these meetings have been examined. Details regarding the department of origin were registered. We determined the level of evidence (according to the AAOS classification system), found the amount of papers that were published in PubMed journal and noted if a department of another country participated.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 1 - 1
1 May 2017
Malahias M Babis G Kaseta M Chytas D Kazas S Nikolaou V
Full Access

Introduction

We investigated whether grey scale early ultrasonography could be used for the accurate initial diagnosis of non displaced occult scaphoid fractures.

Methods

This is a prospective blind clinical study that includes 36 patients that came to the emergency room with suspected clinical symptoms for scaphoid fracture but negative initial X-ray's. After that, a high resolution ultrasonography (without Doppler) was performed. Both wrists of each patient were examined, for comparison. After 14 days, new X-rays were performed, which compared to the early sonographic results of the patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 107 - 107
1 Sep 2012
Waddell JP Nikolaou V Edwards M Bogoch E Schemitsch EH
Full Access

Purpose

This prospective randomised controlled trial aims to compare the clinical and radiological outcomes of ceramic on ceramic, cobalt chrome on ultra-high molecular weight polyethylene, and cobalt chrome on highly cross-linked polyethylene bearing surfaces at a minimum of five years.

Method

One hundred and two primary total hip replacements were performed in ninety one patients between February 2003 and March 2005. All patients were younger than 65 (mean 52.7, 19–64). They were randomised to receive one of the three bearing surfaces. All patients had 28mm articulations with a Reflection uncemented acetabular component and a Synergy stem (Smith & Nephew, Memphis, Tennessee). Patients were followed up periodically up to at least sixty months following surgery. Outcome measures included WOMAC and SF12 scores. Radiological assessment included implant position, evidence of osteolysis and measurement of linear wear.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 110 - 110
1 Sep 2012
Nikolaou V Edwards M Bogoch E Schemitsch E Waddell J
Full Access

This prospective randomised controlled trial aims to compare the clinical and radiological outcomes of ceramic on ceramic, cobalt chrome on ultra-high molecular weight polyethylene, and cobalt chrome on highly cross-linked polyethylene bearing surfaces at a minimum of five years.

One hundred and two primary total hip replacements were performed in ninety one patients between February 2003 and March 2005. All patients were younger than 65 (mean 52.7, 19–64). They were randomised to receive one of the three bearing surfaces. All patients had 28mm articulations with a Reflection uncemented acetabular component and a Synergy stem (Smith & Nephew, Memphis, Tennessee). Patients were followed up periodically up to at least sixty months following surgery. Outcome measures included WOMAC and SF12 scores. Radiological assessment included implant position, evidence of osteolysis and measurement of linear wear.

Ninety seven hip replacements in eighty seven patients were available for review at a minimum of five years. Two hips were revised (one for infection and one for periprosthetic fracture), leaving a total of ninety four hips available for final review. There were no differences in age, gender, body mass index, diagnosis, level of activity, and co-morbidities between the three groups. At a minimum of five years there were no statistical differences in the clinical outcomes using the WOMAC or SF12 scores. Three patients in the ceramic group reported squeaking. Radiological evaluation revealed mean annual wear rates in the ceramic group of 0.006mm/yr, standard polyethylene of 0.151mm/yr and highly cross linked polyethylene of 0.059mm/yr. ANOVA analysis revealed these differences in wear rates to be significant (p<0.0001).

In the mid term there are no differences in clinical outcome between ceramic on ceramic, cobalt chrome on ultra-high molecular weight polyethylene, and cobalt chrome on highly cross-linked polyethylene bearing surfaces in total hip arthroplasty. Ultra high molecular weight polyethylene has a significantly greater annual linear wear rate than highly cross-linked polyethylene.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 172 - 172
1 Jun 2012
Waddell J Edwards M Lutz M Keast-Butler O Escott B Schemitsch E Nikolaou V
Full Access

Purpose

To review prospectively collected data on patients undergoing primary total hip arthroplasty utilizing two different cementless acetabular components.

Materials & Methods

All patients undergoing primary total hip replacement surgery at our institution are entered prospectively into a database which includes history and physical examination, radiology, WOMAC and SF-36 scores. The patients are re-examined, re-x-rayed and re-scored at 3 months, 6 months and 1 year after surgery and yearly thereafter.

Using this database we are able to identify patients who have undergone total hip replacement using one of two geometric variants of the acetabular component. The first design is hemispherical and the second design has a peripheral rim expansion designed to increase initial press-fit stability.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 6 - 6
1 Jun 2012
Waddell J Baird R Nikolaou V Schemitsch E
Full Access

To review prospectively collected data on patients undergoing femoral revision arthroplasty for failed cemented or cementless primary stems.

Materials & Methods

All patients undergoing primary and revision joint replacement surgery at our institution are prospectively entered into a database which includes history and physical examination, radiology, WOMAC and SF-36 scores. These investigations are repeated 3 months, 6 months, 1 year and yearly thereafter at each patient visit.

This database identified all patients undergoing femoral revision arthroplasty over the last 10 years.

Results

There were a total of 231 patients with 248 revision procedures performed. There were 127 female and 104 male patients and the mean age at the time of revision surgery was 69.4 years. Twenty-two of these patients had had at least one prior revision operation on the index hip. Thirty hips were treated with a cemented Echelon stem and 218 treated with a cementless Echelon stem. Of the 248 hips 14 patients were lost to follow-up (14 hips) and 9 patients (9 hips) are deceased. The average follow-up was 5.9 years.

Of the 225 hips remaining in the follow-up series there was a single case of aseptic loosening confirmed radiologically. Twenty-one hips were diagnosed with infection (9.3%); 6 of those patients had had at least one prior revision procedure and 4 additional patients had a prior diagnosis of infection. Therefore, 10 of the 21 hips were either definitely or probably infected at the time of their revision operation on which we are reporting. Nine patients (4%) had multiple dislocations post-operatively. These were patients who had undergone multiple revisions or whose primary revision operation was for instability. An additional 18 patients (8%) had a single dislocation treated by closed reduction requiring no further treatment.

There were 6 hips with intra-operative fracture requiring immediate re-revision plus fracture fixation and a further 12 hips (5.3%) who sustained a peri-prosthetic fracture some time after their revision procedure.

Despite the number of complications the majority of patients required no further surgical treatment. Eleven hips (4.8%) required re-revision of the femoral component. Therefore the overall survival rate at 5.9 years of the Echelon revision stem was 95.2%.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 173 - 173
1 Jun 2012
Waddell J Nikolaou V Edwards M Bogoch E Schemitsch E
Full Access

Aim

This prospective randomised controlled trial aims to compare the clinical and radiological outcomes of ceramic on ceramic, cobalt chrome on ultra-high molecular weight polyethylene, and cobalt chrome on highly cross-linked polyethylene bearing surfaces at a minimum of five years.

Methods

One hundred and two primary total hip replacements were performed in ninety one patients between February 2003 and March 2005. All patients were younger than 65 (mean 52.7, 19-64). They were randomised to receive one of the three bearing surfaces. All patients had 28mm articulations with a Reflection uncemented acetabular component and a Synergy stem (Smith & Nephew, Memphis, Tennessee). Patients were followed up periodically up to at least sixty months following surgery. Outcome measures included WOMAC and SF12 scores. Radiological assessment included implant position, evidence of osteolysis and measurement of linear wear.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 356 - 356
1 Jul 2011
Efstathopoulos N Xypnitos F Nikolaou V Lazarettos J Kaselouris E Venetsanos D Provatidis C
Full Access

We investigated the effect of the location and the number of distal screws in the efficiency of an intramedullary nail implementing the finite element method (FEM).

The left proximal femur of a 93-year old man was scanned and two series of full 3D models were developed. The first series, consisting of five models, concerned the use of a single distal screw inserted in five different distal locations. The second series, consisting of four models, concerned the use of four different pairs of distal screws. Each model was analyzed with the (FEM) twice, first considering that the femur is fractured and then considering that the femur is healed.

For nails with a single distal screw, stresses around the nail hole were reduced with proximal placement of the distal screw but the area around the nail hole where the lag screw is inserted is stressed more. Furthermore, for nails with a pair of distal screws, placing the pair of distal screws at a specific location is most beneficial for the mechanical behavior of the femur/nail assembly.

The distal area of the nail generally gets less stressed when a pair of distal screws is introduced, while the presence of two distal screws far away from each other results in lower proximal femoral head displacements. The stress field at the area of fracture is not influenced significantly by the presence of a single distal screw or a pair of distal screws.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 370 - 370
1 Jul 2011
Giannoudis P Kanakaris N Stavlas P Nikolaou V Prevezas N
Full Access

The purpose of this study was to investigate the outcome of acetabular fractures treated in our institution with marginal impaction.

Over a 5 year period consecutive acetabular cases treated in our institution with marginal impaction were eligible for inclusion in this study. Exclusion criteria were patients lost to follow up and pathological fractures. A retrospective analysis of prospectively documented data was performed. Demographics, fracture types according to the Judet-Letournel classification, radiological criteria of intra-operative reduction (Matta) and secondary collapse, complication rates, and the EuroQol-5D questionnaire were documented over a median period of follow-up of 40 months (12–206).

Out of 400 cases, eighty-eight acetabular fractures met the inclusion criteria. The majority (93.2%) involved males with a median age of 40.5 years (16–80). Half of them were posterior-wall fractures, 21.6% bicolumn, 14.7 %posterior-wall and column, 6.8% transverse, 5.7% anterior-column, 1.1% anterior-column posterior hemi-transverse. In 75% of the cases anatomical intra-operative reduction was achieved. Structural-bone-graft was used in 73.9%, and two-level reconstruction in 61%. At the last follow-up, the originally achieved anatomical reduction was lost in 17/66 (25.8%), (10 PW, 4 PC+PW, 1 PC, 1 Transverse, 1 Bicolumn fracture). Avascular necrosis developed in 9.1% and heterotopic ossification in 19.3%. Full return to previous activities was documented in 48.9% of cases, the EuroQol general heath state score had a median of 80% (30–95%), full recovery was recorded as to the patients’ mobility in 51.1%, as to pain in 47.7%, as to self-care in 70.5%, as to work-related activities in 55.7%, and as to emotional parameters in 65.9%. Reoperation (heterotopic-ossification excision, total-hip-arthroplasty, removal of metalwork) was necessary in 19.2% of cases.

Utilising different techniques of elevation of the articular joint impaction leads to joint preservation with satisfactory overall functional results. Secondary collapse was noted in 25.8% of the patients predisposing to a poorer outcome


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 362 - 362
1 Jul 2011
Giannoudis P Kanakaris N Tzioupis C Nikolaou V Kontakis G
Full Access

To evaluate the effectiveness of Pulsed-Lavage and of Versajet-hydrosurgery in removing two Staphylococcus aureus strains from porcine tissue and graphite powder from simulated fractures.

Overnight broth cultures (NCTC-6571) and S.aureus strains were diluted to yield inocula containing 1x103c. f.u. ml-1. Initially 8 porcine legs were used; porcine tissues were inoculated with 10ml of either of the two S.aureus strains. Control tissues were inoculated with PBS. All inoculated samples were irrigated with 300ml of saline using the pulsed-lavage system or using the Versajet. 10ml of each of the following were plated out in triplicate:

inoculum pre-incubation

inoculum post-incubation,

each left over inoculum following removal of tissue and dilutions of 10-1 and 10-2 and

Wash from all samples.

Eight additional porcine legs were used where 2 incisions were made down to bone in a cross-hatch pattern. 1g of graphite powder was infiltrated into each fracture site to simulate a contaminated open fracture. Each fracture site was irrigated with 500ml saline through pulsed-lavage or Versajet.

The average microbiological reduction using Pulsed-Lavage or Versajet was 2% and 15% respectively. The clinical S.aureus strain was more adherent than the laboratory strain. The Versajet maintained a 12–16% reduction of S.aureus, whereas pulsed-lavage did not reduce contamination. The number of graphite particles was significantly reduced with the use of the Versajet system compared with the pulsed-lavage.

Versajet system was more effective in removal of foreign particles and more effectively reduced the micro-biological load of both examined S.aureus strains in a porcine model. Further studies are indicated to evaluate the efficacy of this system in clinical practice


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 306 - 306
1 Jul 2011
Giannoudis P Kanakaris N Nikolaou V Morell D Prevezas N
Full Access

Purpose: The purpose of this study was to investigate the outcome of acetabular fractures treated in our institution with marginal impaction.

Patients & Methods: Over a 5 year period consecutive acetabular cases treated in our institution with marginal impaction were eligible for inclusion in this study. Exclusion criteria were patients lost to follow up and pathological fractures. A retrospective analysis of prospectively documented data was performed. Demographics, fracture types according to the Judet-Letournel classification, radiological criteria of intra-operative reduction (Matta) and secondary collapse, complication rates, and the Euro-Qol-5D questionnaire were documented over a median period of follow-up of 40months (12–206).

Results: Out of 400 cases, eighty-eight acetabular fractures met the inclusion criteria. The majority (93.2%) involved males with a median age of 40.5years (16–80). Half of them were posterior-wall fractures, 21.6% both column, 14.7% posterior-wall and posterior-column, 6.8% transverse, 5.7% anterior-column, 1.1% anterior-column posterior hemi-transverse. In 75% of the cases anatomical intraoperative reduction was achieved. Structural-bone-graft was used in 73.9%, and two-level reconstruction in 61%. At final follow-up, the originally achieved anatomical reduction was lost in 17/66 (25.8%), (10 PW, 4 PC+PW, 1 PC, 1 Transverse, 1 Bicolumn fracture). Avascular necrosis developed in 9.1% and heterotopic ossification in 19.3%. Full return to previous activities was documented in 48.9% of cases, the EuroQol general heath state score had a median of 80% (30–95%), full recovery was recorded as to the patients’ mobility in 51.1%, as to pain in 47.7%, as to self-care in 70.5%, as to work-related activities in 55.7%, and as to emotional parameters in 65.9%. Reoperation (heterotopic-ossification excision, total-hip-arthroplasty, removal of metalwork) was necessary in 19.2% of cases.

Discussion/Conclusion: Utilising different techniques of elevation of the articular joint impaction leads to joint preservation with satisfactory overall functional results. Secondary collapse was noted in 25.8% of the patients predisposing to a poorer outcome.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 358 - 358
1 Jul 2011
Efstathopoulos N Sourlas J Lazarettos J Nikolaou V Brilakis E Xypnitos F
Full Access

To evaluate the clinical outcome of arthroscopic treatment of ACL with an Achilles tendon allograft in patient with acute rupture.

22 patients, between 2003 and 2006, with acute rupture of ACL, were treated with an Achilles tendon allograft. The mean age was 26 years. Patients were evaluated before and after surgery and at the latest follow-up with Noulis-Lahmann test and Pivot shift test. We also used IKDC score, Lysholm score and one leg stance test and functional reach test. Patients were also evaluated with Cybex II + and with plain radiographies.

The mean follow-up time was 3.5 years. 90% of the patients had a negative pivot shift test and 95% of the patients had a score at Noulis-Lahmann test +1. The mean value of IKDC score was 88 (62–100) and the mean time of Lysholm score was 91 (75–100). Until the latest follow-up there were no clinical sighs of inflammation or graft rejection. Radiologic evaluation revealed no sign of tunnel enlargement.

We believe that the use of a fresh-frozen allograft in the treatment of acute ACL ruptures is an effective procedure for the restoration of ligamentous stability of the knee.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 130 - 130
1 May 2011
Nikolaou V Petit A Huk O Zukor D Bergeron S Antoniou J
Full Access

Introduction: Several studies have shown the presence of cobalt (Co) and chromium (Cr) ions in blood, urine, and organs of patients after THA using Co-Cr alloy-based implants. Even though it is well known that exposure to heavy metals may lead to significant alterations in human sperm morphology and motility, less is known on the effect of Co and Cr on semen parameters after metal on metal (MOM) hip replacement.

Methods: Semen was collected form 10 patients between 41 and 49 years old (mean=45.9±3.0 years) by masturbation after 2–3 days of abstinence. The time of implantation varied from 1 to 9 years (mean=5.1±3.9 years). Samples were collected in a sterile container and examined within 1h after ejaculation for morphology, motility, and number of sperm cells following standard criteria. All patients were doing well at their follow-up visits (Harris Hip Score=94±4; UCLA activity a score=7±1) and no sign of osteolysis was observed on X-rays.

Co and Cr concentrations were measured in both the seminal plasma and in the blood of patients by inductively coupled plasma-mass spectroscopy (ICP-MS).

Results: results showed that the levels of Co in the seminal plasma and the blood of the patients were not statistically different. However, the level of Cr was significantly lower in the seminal plasma than in the blood of the patients. The ejaculate volume (2.1 ±0.6 ml), the sperm density (66±53 x 106), the total sperm count (151±75 x 106/ml), the pH (8), and the percentage of normal morphology (46±18%) were in the range of the WHO criteria for fertile population and also in the range of reference patients in the city of measurements. However, the viability was lower than that observed in a fertile population without prosthesis (41±19%).

Conclusions: results of the present study strongly suggest that both Co and Cr ions crossover to the semen but that their concentrations were too low to significantly affect sperm parameters of young patients with MM prosthesis. Further longitudinal studies are however necessary to conclusively determine the effect of metal ions from MM prosthesis on sperm parameters.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 130 - 130
1 May 2011
Nikolaou V Khoury V Huk O Petit A Bergeron S Zukor D Antoniou J
Full Access

Aim: To determine the MRI findings in patients with persistent painful metal on metal (MOM) hip arthroplasty and compare the results with a control group of patients with MOM or metal on polyethylene THA without symptoms.

Methods: 20 patients with normal inflammatory markers and normal plain radiographic imaging that had undergone primary THA were enrolled to this study. Patients were chosen to be included in 4 groups;

Patients having metal-on-polyethylene THA or resurfacing without pain (Control group),

Patients having MOM THA or resurfacing with high levels of metal ions (cobalt and chromium) and having pain

Patients having MOM THA or resurfacing with high levels of metal ions but having no pain and

Patients having MOM THA or resurfacing with low levels of metal ions and having no pain.

Operated hips were evaluated with MRI by one musculoskeletal radiologist who was blinded to the radiographic findings and clinical symptoms. All images were assessed for the presence of a juxtaarticular or periprosthetic abnormalities, including fluid collections, soft tissue masses, osseous abnormalities, and patterns of contrast enhancement of lesions.

Results: 5 patients were included in each group. All patients had undergone their THA at least 1 year prior to the MRI examination (mean 18 months). MRI findings including muscle atrophies, joint effusions, stress fractures, bone marrow oedema and muscle avulsions were equally distributed in all groups.

Conclusions: MOM THA or high metal ion levels had no specific MRI findings to explain the hip pain in these groups of patients.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 185 - 185
1 May 2011
Giannoudis P Kanakaris N Nikolaou V Prevezas N
Full Access

Purpose: The purpose of this study was to investigate the outcome of acetabular fractures treated in our institution with marginal impaction.

Patients and Methods: Over a 5 year period consecutive acetabular cases treated in our institution with marginal impaction were eligible for inclusion in this study. Exclusion criteria were patients lost to follow up and pathological fractures. A retrospective analysis of prospectively documented data was performed. Demographics, fracture types according to the Judet-Letournel classification, radiological criteria of intra-operative reduction (Matta) and secondary collapse, complication rates, and the Euro-Qol-5D questionnaire were documented over a median period of follow-up of 40months (12–206).

Results: Out of 400 cases, eighty-eight acetabular fractures met the inclusion criteria. The majority (93.2%) involved males with a median age of 40.5years (16–80). Half of them were posterior-wall fractures, 21.6%bicolumn, 14.7%posterior-wall and column, 6.8%transverse, 5.7%anterior-column, 1.1%anterior-column posterior hemi-transverse. In 75% of the cases anatomical intra-operative reduction was achieved. Structural-bone-graft was used in 73.9%, and two-level reconstruction in 61%. At the last follow-up, the originally achieved anatomical reduction was lost in 17/66 (25.8%), (10 PW, 4 PC+PW, 1 PC, 1 Transverse, 1 Bicolumn fracture). Avascular necrosis developed in 9.1% and heterotopic ossification in 19.3%. Full return to previous activities was documented in 48.9% of cases, the EuroQol general heath state score had a median of 80% (30–95%), full recovery was recorded as to the patients’ mobility in 51.1%, as to pain in 47.7%, as to self-care in 70.5%, as to work-related activities in 55.7%, and as to emotional parameters in 65.9%. Reoperation (heterotopic-ossification excision, total-hip-arthroplasty, removal of metalwork) was necessary in 19.2% of cases.

Conclusion: Utilising different techniques of elevation of the articular joint impaction leads to joint preservation with satisfactory overall functional results. Secondary collapse was noted in 25.8% of the patients predisposing to a poorer outcome