Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 66 - 66
1 Feb 2020
Oh J Yang W Moore T Dushaj K Cooper H Hepinstall M
Full Access

Background

Cementless femoral fixation in total hip arthroplasty (THA) continues to rise worldwide, accompanied by the increasing abandonment of cemented femoral fixation. Cementless fixation is known to contribute to higher rates of post-operative complications and reoperations. New data is available from the Centers for Medicare and Medicaid Services (CMS) regarding total costs of care from the Bundled Payment for Care Improvement (BPCI) and Comprehensive Care for Joint Replacement (CJR) initiatives.

Questions/purposes

How does femoral fixation affect (1) 90-day costs; (2) readmission rates; (3) re-operation rates; (4) length of stay (LOS); and (5) discharge disposition for Medicare patients undergoing elective or non-elective THA?


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 30 - 30
1 Apr 2018
Jeong H Kong B Rhee S Nam K Park J Yeo J Lee K Oh J
Full Access

Introduction

Previous hemodynamics studies in shoulder arthroplasty only evaluated Western population and mainly focused on risk factors of transfusion. However, Asians are relatively small, and have higher bleeding risk due to prothrombin-clotting-factor polymorphisms. Therefore, it is not appropriate to apply the results of previously studies directly to Asians. Authors compare different hemodynamics depending on the types of shoulder arthroplasties, and evaluate predictors for transfusion in Asian population.

Methods

Total 212 shoulder arthroplasties (26 fracture hemiarthroplasty (fHA), 49 anatomical total shoulder arthroplasty (aTSA), 132 reverse total shoulder arthroplasty (rTSA), and 5 revision surgery) from August 2004 to January 2016 were retrospectively reviewed. Demographics, surgical factors and perioperative hemodynamic factors were compared for each type of arthroplasty. Multivariate regression analysis was conducted to determine predictors for transfusion.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 19 - 19
1 Apr 2018
Park J Sharma N Rhee S Oh J
Full Access

Introduction & Background

Clinical outcome after reverse total shoulder arthroplasty (RTSA) can be influenced by technical and implant-related factors, so the purpose of this study was to investigate whether individualizing humeral retroversion and subscapularis repair affect the clinical outcomes after RTSA.

Material & Method

Authors retrospectively analyzed the prospectively collected data from 80 patients who underwent RTSA from January 2007 to January 2015 using same implant (Biomet Comprehensive® Reverse Shoulder System, Warsaw, Indiana). The mean follow up was 23.3 ± 1.7 (range, 12 ∼ 70) months. The retroversion of humeral component was decided according to native version estimated using shoulder CT in Group I (n=52), and fixed in 20° retroversion in Group II (n=28). Group I was subdivided into Group Ia (n=21, mean 19.3°), less than 20° of retroversion, and Group Ib (n=31, mean 31.9°), more than 20°. Intraoperative tenotomized subscapularis was repaired in 40 patients in Group I, and could not be repaired due to massive tear including subscapularis in remaining 12 patients. Clinical outcomes were evaluated with range of motion (ROM) and several clinical outcome scores.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 31 - 31
1 Apr 2018
Kim W Kim D Rhie T Oh J
Full Access

Background

Humeral retroversion is variable among individuals, and there are several measurement methods. This study was conducted to compare the concordance and reliability between the standard method and 5 other measurement methods on Twodimensional (2D) computed tomography (CT) scans.

Methods

CT scans from 21 patients who underwent shoulder arthroplasty (19 women and 2 men; mean age, 70.1 years [range, 42 to 81 years]) were analyzed. The elbow transepicondylar axis was used as a distal reference. Proximal reference points included the central humeral head axis (standard method), the axis of the humeral center to 9 mm posterior to the posterior margin of the bicipital groove (method 1), the central axis of the bicipital groove –30° (method 2), the base axis of the triangular shaped metaphysis +2.5° (method 3), the distal humeral head central axis +2.4° (method 4), and contralateral humeral head retroversion (method 5). Measurements were conducted independently by two orthopedic surgeons.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 122 - 122
1 Mar 2010
Oh J Oh C Kim S Jo K Bin S Yoon J
Full Access

We evaluated the outcome of hemiarthroplasty with bone block graft and low profile prosthesis (Aequalis® fracture prosthesis) for the comminuted proximal humerus fractures. Sixteen low profile prostheses were used since July 2004, and 11 patients were followed-up for average 19.9 (12–30) months. Their mean age was 67.3 (52–78) years. Cemented stem in all cases. Two bone block graft and cancellous chip bone from resected humeral head. Ten cases for Neer type 4 fracture, one case for type 3 fracture. During 6 weeks, abduction brace with neutral rotation position was maintained. Passive and active range of motion exercise started at 6 weeks. Pain and satisfaction visual analog scale (VAS), range of motion, and modified UCLA score for hemiarthroplasty were evaluated at every visit. Radiography was also checked for stem position, loosening, and tuberosity union.

Mean pain VAS was 2.7 (0–5), and mean satisfaction VAS was 8.4 (5–10). Mean active forward flexion was 137o (90–170), external rotation at side was 45.5o (25–70), and internal rotation at back was T10 (T7-L1). Modified UCLA score was 19 (12–30) at final visit. All stems were stable, and there were no loosening at the final follow-up. All tuberosities were united except two tuberosity absorptions. One complication case was infection.

The outcome of hemiarthroplasty with bone block graft and low profile prosthesis was comparable to other implants for comminuted proximal humerus fractures. This system had unique advantages for tuberosity union. Further study with more patients and longer follow-up period are necessary to clarify the effectiveness of this prosthesis.