Assessment for and treatment of osteoporosis is recommended following hip fracture. All forms of osteoporosis treatment require an adequate calcium intake and normal vitamin D levels. This study assesses vitamin D levels in patients with hip fractures and describes guidelines on how to manage low vitamin D levels with high dose oral vitamin D3 (cholecalciferol). Circulating 25-hydroxyvitamin D levels were measured in consecutive patients with a hip fracture over an 18 month period. Substitution therapy with high dose oral cholecalciferol was started in 2 selected cohorts; one group received substitution therapy for 3 days, the second group for 7 days.Introduction
Materials and methods
With the recent trend towards enhanced care in joint replacement, it has become increasingly important to identify and address the areas that affect early patient length of stay, while ensuring that practice remains safe. As part of an enhanced care program we conducted two prospective studies of factors delaying discharge following hip replacement in 2006 and 2010. In each limb of the study data was collected prospectively daily, by an independent observer, on 100 consecutive primary cemented total hip replacements. Reasons for delay to the discharge and variation from the patient pathway were identified and addressed.Background
Materials and Methods
Awareness that minimising tip apex distance (TAD) when inserting a sliding hip screw reduces the risk of screw cut out is important for orthopaedic trainees. The advent of the Picture Archive and Communication System (PACS) has made the accurate measurement of TAD from x-rays and image intensifier films much easier. This study was to determine whether TAD would be reduced if a surgeon knew that his performance was being continually monitored. 31 consecutive cases of sliding hip screw insertion by a single group of surgeons were identified and the TAD measured. The mean TAD was 16.11mm (8.87mm-25.47mm). The same surgeons were then re-educated as to the importance of the TAD and informed that their results would be monitored and discussed. The next 34 consecutive cases were collected prospectively. The mean TAD in these cases was 13.83mm (6.72mm-21.51mm). There was a significant difference between the TAD for the two groups using the two-tailed t-test (p=0.034). There was one implant failure in the pre education group and none in the post education group. These results suggest that awareness of surveillance improves surgical performance even if the importance of the variable being assessed is already known.
+ Assistant model would play a pivotal role in managing patient flow efficiently.
An increase in the number of new referrals seen in OPD by 50% from 8 to 12 per clinic. An increase in the volume of hip &
knee replacements from 490 in 2003 to 834 in 2007. Increased theatre efficiency with routinely 2 joints per session. A reduction in length of stay from mean of 10.75 days in 2003 to 6.89 days in 2007. Continuous monitoring of post-operative infections with current cumulative rate of 0.71%. Improved patient satisfaction as measured by patient feedback sessions.
Reports are beginning to emerge of unexplained failure, pseudotumour formation, individual cases of metallosis. Joint registry data also demonstrates an unexplained high early failure rate for all designs of hip resurfacing. This paper examines the rate and mode of early failures of the BHR in a multi-centre, multi-surgeon series.
The likely rate of metallosis is 3.1% at five years. Risk factors for metallosis in this series are female sex, small femoral component, high abduction angle and obesity. We not advocate use of the BHR in patients with these risk factors.
We report the results of cementless total hip arthroplasty using the Bi-metric titanium femoral stem at a minimum follow up of 10 years and a mean of 12.2 years (range 10–17). 64 hips (43 male/21 female) were implanted consecutively into 54 patients between 1988 and 1995. The mean age at operation was 54.3 years (range 42–65). All patients had a Bi-metric uncemented stem (Biomet UK). The first 13 patients received a metal backed screw in acetabular cup (TTAP-ST, Biomet UK) with the remainder receiving metal backed pressfit cups (Universal, Biomet UK). All patients were followed up annually and assessed using the Hip Society Score (HSS; max 40 points) to record pain, function and mobility. Survivorship was calculated using the Kaplan-Meier method. 57 hips were followed up for a minimum of ten years. There were 4 deaths (6 hips) before completion of follow up and 1 patient was lost to follow up. Using revision for any reason as the end point of the study; survivorship for the total hips at 10 years was 89.5% (95% confidence interval: 78.1–96.1%) with a mean Hip Society Score of 34.9 (range 20–40) compared to 14.5 (range 8–24) pre-operatively (p<
0.01 student t test). Survivorship for the femoral stem in isolation was 100% at 10 years (95% CI 93.7–100%) and there continues to be no revisions to date at a mean follow up of 12.2 years. The screw fix cup performed poorly with 3 acetabular revisions (including 1 liner change) before the 10 year follow up, a failure rate of 23.1%. There has sub-sequently been a further 4 acetabular revisions. Ten year survivorship for the pressfit cup is 93.5% (95% CI 82.0–98.8%) with 3 revisions (including 2 liner changes) at ten years. There has subsequently been one further acetabular revision and 9 further liner changes (29.5% failure rate). There have been no recorded infections and no instances of thigh pain. Radiographs at ten years showed all the femoral stems were stable with no evidence of migration. Two stems had small radiolucent lines at the bone-implant interface but no signs of loosening. One stem had an area of osteolysis in Gruen zone 7 but didn’t require revision. Rates of osteolysis were extremely low given the large amounts of particulate debris in the hip from the worn acetabular liners. In conclusion, although neither cup has proved to be particularly successful the Bi-metric stem has performed well at 10 year follow up and continues to do so. This is inspite of the fact they were implanted into a young and active group of patients.
Radiographic analysis was undertaken using Harris’, Hodgkinson’s and Amstutz’s criteria, evaluation of component position, neck narrowing and migration using diagnostic PACS workstations with standardised scaled images.
Component position was satisfactory in 93% of cases. Radiographic analysis showed no cups, or stems were definitely loose. Radiolucent lines were present in 8/100 acetabular and 3/100 femoral components, osteolytic lesions were seen in three acetabular components. Mean neck narrowing was 9mm. No patients show any radiographic evidence of avascular necrosis. Conclusion This independent series shows the results of the Birmingham hip resurfacing are reproducible and comparable to those reported in the originating centre. The Birmingham hip resurfacing gives excellent clinical results, and there is no early evidence of radiographic failure. The high rate of neck narrowing gives us cause for concern and we would recommend regular radiographic follow up.
The literature produces some evidence of a higher early complication rate in obese patients undergoing THA, and operative time seems to be longer and blood loss greater than for matched controls. The only study looking at long-term outcome of THA showed no difference in hip survivorship at 10–18 years between obese and normal weight patients. We conclude that where THA is concerned, the PCT policy has no clinical or evidence based justification.