Management of complex fractures poses a significant challenge. Evolving research and changes to national guidelines suggest better outcomes are achieved by transfer to specialist centres. The development of Major Trauma Networks was accompanied by relevant financial arrangements. These do not apply to patients with closed fractures referred for specialist treatment by similar pathways. Despite a surge in cases transferred for care, there is little information available regarding the financial impact on receiving institutions. This retrospective study examines data from a Level 1 trauma centre. Patients were identified from our electronic referral system, used for all referrals. Transferred adult patients, undergoing definitive treatment of acute isolated closed tibial fractures, were included for a 2-year period. Data was collected using our clinical and Patient Level Information and Costing (PLICS) systems including coding, demographics, treatment, length of stay (LOS), total operative time, number of operations, direct healthcare costs, and NHS reimbursements.Introduction
Materials & Methods
Routine radiographs in the follow-up of circular frames is commonplace, however the effect on clinical decision making is unclear. Previous work locally has suggested that >95% of radiographs, particularly at early time points, do not affect clinical management. This study was conducted to assess the impact of a transition to early remote follow-up on circular frame patients with limited radiographic assessment. Patients were identified from a prospective limb reconstruction database. Data were collected including the number of clinic appointments, type of clinic appointment, number of radiographs performed, and impact this had on clinical management. This was compared to our previous cohort of 85 patients undergoing standard follow-up.Introduction
Materials and Methods
Numerous fixation modalities can be used for various indications, including deformity correction, trauma, infection, and non-union. The Modular Rail System (MRS) is a well-tolerated apparatus that is a viable option for patients who do not want a circular frame or for whom internal fixation is not appropriate due to poor soft tissues/co-morbidities. This case series evaluates the outcomes of the use of the MRS in our centre. Cases were identified from a prospectively gathered database. Data were collected including indication for treatment, frame duration, complications and treatment outcome. Eighteen eligible cases were identified (mean age 26, range 8–71). The MRS was sited in the femur in 14 cases, the tibia in three and the fibula in one. In nine cases, a circular frame was sited on the tibia below a femoral MRS. Frames were removed at an average of 20 weeks (range 7–31).Introduction
Materials and Methods