Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 29 - 29
23 Apr 2024
Ahmed T Upadhyay P Menawy ZE Kumar V Jayadeep J Chappell M Siddique A Shoaib A
Full Access

Introduction

Knee dislocations, vascular injuries and floating knee injuries can be initially managed by a external fixator. Fixator design constructs include the AO pattern and the Diamond pattern. However, these traditional constructs do not adhere to basic principles of external fixation. The Manchester pattern knee-spanning external fixator is a new construct pattern, which uses beam loading and multiplanar fixation. There is no data on any construct pattern. This study compares the stability of these designs.

Materials & Methods

Hoffman III (Stryker, USA) external fixation constructs were applied to articulated models of the lower limb, spanning the knee with a diamond pattern and a Manchester pattern. The stiffness was loaded both statically and cyclically with a Bose 3510 Electroforce mechanical testing jig (TA Instruments). A ramp to load test was performed initially and cyclical loading for measurement of stiffness over the test period. The results were analysed with a paired t-test and ANOVA.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 461 - 461
1 Aug 2008
Walsh G Das K Siddique A Flood B Chapman J Halder S
Full Access

The results of displaced three part fracture of the proximal humerus treated by retro grade nailing +/− cannulated cancellous screws for fixation of the greater tuberosity was analysed.

Displaced three part fractures of the humerus are unstable and difficult to fix. Different methods of operative treatment available for this type of fracture are Kirschner wires, tension band wiring, hemiarthroplasty and open reduction and internal fixation with plate and screws.

The Halder Humeral Nail was introduced through the olecranon fossa into the head of the humerus, to stabilize the neck of humerus fracture. The displaced greater tuberosity was reduced with a minimal stab incision and fixed with cannulated screws. Compared to other open procedures the proximal exposure was minimal.

47 Patients with displaced three part proximal humeral fractures have been surgically treated since January 1995. 22 Were treated with proximal screws and 25 without proximal screw fixation. There were 32 females and 15 males. The average age was 67.68 years.

Early passive movements were encouraged in the shoulder. Pain was relieved in almost all the patients. 41 Fractures united. 3 Patients had a malunion, 2 had humeral head collapse, and 1 developed AVN of the humeral head.

The authors concluded that displaced three part proximal humeral fractures can be treated using the Halder Humeral Nail, and that this is a simple method of treatment which avoids major surgical exposures.