Retrospective review of a consecutive series of 1,168 total ankle replacements (TAR) performed at Wrightington, to analyse modes of failure and clinical outcomes following TAR failure. All patients undergoing TAR between November 1993 – June 2019 were collated (4–25 year follow-up; mean 13.7 years). 6 implants were used (300 STAR, 100 Buechal Pappas, 509 Mobility, 118 Zenith, 41 Salto and 100 Infinity). 5 surgeons, all trained in TAR, performed the surgery. Modes of failure were collated and clinical and radiological outcomes recorded for the revisional surgery following failure of the TAR.Aims
Methods
This is a multi-centre, prospective, observational study of 503 INFINITY fixed bearing total ankle arthroplasties. We report the minimum two-year results of this prosthesis which was introduced to the UK Market in 2014 and is now the most used ankle arthroplasty in the National Joint Registry of England and Wales. Patients were recruited from 11 centres in the United Kingdom between June 2016 and November 2019. Demographic, radiographic, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Foot Ankle Questionnaire and Euroquol 5D-5L) were collected preoperatively, at 6 months, 1 year and 2 years and 5 years. The average age was 67.8 (range 23.9 to 88.5) and average BMI 29.3 (18.9 to 48.0). The COFAS grading system was used to stratify deformity. There were 261 (51.9%) COFAS Type 1, 122 (24.2%) COFAS Type 2, 31 (6.2%) COFAS 3 and 89 (17.7%) COFAS type 4. 38 patients (7.6%) presented with inflammatory arthritis. 99 (19.7%) implantations utilised patient specific instrumentation. Complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts and/or subsidence.Introduction
Methods
To determine the risk of total knee replacement (TKR) for primary osteoarthritis (OA) associated with overweight/obesity in the Australian population. This population-based study analyzed 191,723 cases of TKR collected by the Australian Orthopaedic Association National Joint Registry and population data from the Australian Bureau of Statistics. The time-trend change in incidence of TKR relating to BMI was assessed between 2015-2018. The influence of obesity on the incidence of TKR in different age and gender groups was determined. The population attributable fraction (PAF) was then calculated to estimate the effect of obesity reduction on TKR incidence. The greatest increase in incidence of TKR was seen in patients from obese class III. The incidence rate ratio for having a TKR for obesity class III was 28.683 at those aged 18-54 years but was 2.029 at those aged >75 years. Females in obesity class III were 1.7 times more likely to undergo TKR compared to similarly classified males. The PAFs of TKR associated with overweight or obesity was 35%, estimating 12,156 cases of TKR attributable to obesity in 2018. The proportion of TKRs could be reduced by 20% if overweight and obese population move down one category. Obesity has resulted in a significant increase in the incidence of TKR in the youngest population in Australia. The impact of obesity is greatest in the young and the female population. Effective strategies to reduce the national obese population could potentially reduce 35% of the TKR, with over 10,000 cases being avoided.
Proximal femoral focal deficiency is a congenital disorder of malformation of the proximal femur and/or the acetabulum. Patients present with limb length discrepancy and clinical features along a spectrum of severity. As these patients progress through to skeletal maturity and on to adulthood, altered biomechanical demands lead to progression of arthropathy in any joint within the lower limb. Abnormal anatomy presents a challenge to surgeons and conventional approaches and implants may not necessarily be applicable. We present a case of a 62-year-old lady with unilateral proximal femoral focal deficiency (suspected Aitken Class A) who ambulated with an equinus prosthesis for her entire life. She presented with ipsilateral knee pain and instability due to knee arthritis but could not tolerate a total knee arthroplasty due to poor quadriceps control. A custom osteointegration prosthesis was inserted with a view to converting to the proximal segment to a total hip replacement if required. The patient went on to develop ipsilateral symptomatic hip arthritis but altered acetabular anatomy required a custom tri-flange component (Ossis, Christchurch, New Zealand) and a custom proximal femoral component to link with the existing osseointegration component (Osseointegration Group of Australia, Sydney, Australia) were designed and implanted. The 18 month follow up of the custom hip components showed that the patient had Oxford hip scores that were markedly improved from pre-operatively. Knee joint heights were successfully restored to equal when the patient's prosthesis was attached. The patient describes feeling like “a normal person”, walks unaided for short distances and can ambulate longer distances with crutches. Advances in design and manufacture of implants have empowered surgeons to offer life improving treatments to patients with challenging anatomy. Using a custom acetabular tri-flange and osseointegration components is one possible solution to address symptomatic ipsilateral hip and knee arthropathy in the context of PFFD in adulthood.
Rates of prosthetic joint infection in megaprostheses are high. The application of silver ion coating to implants serves as a deterrent to infection and biofilm formation. A retrospective review was performed of all silver-coated MUTARS endoprosthetic reconstructions (SC-EPR) by a single Orthopaedic Oncology Surgeon. We examined the rate of component revision due to infection and the rate of infection successfully treated with antibiotic therapy. We reviewed overall revision rates, sub-categorised into the Henderson groupings for endoprosthesis modes of failure (Type 1 soft tissue failure, Type 2 aseptic loosening, Type 3 Structural failure, Type 4 Infection, Type 5 tumour progression). 283 silver-coated MUTARS endoprosthetic reconstructions were performed for 229 patients from October 2012 to July 2022. The average age at time of surgery was 58.9 years and 53% of our cohort were males. 154 (71.3%) patients underwent SC-EPR for oncological reconstruction and 32 (14.8%) for reconstruction for bone loss following prosthetic joint infection(s). Proximal femur SC-EPR (82) and distal femur (90) were the most common procedures. This cohort had an overall revision rate of 21.2% (60/283 cases). Component revisions were most commonly due to Type 4 infection (19 cases), Type 2 aseptic loosening/culture negative disease (15 cases), and Type 1 dislocation/soft tissue (12 cases). Component revision rate for infection was 6.7% (19 cases). 15 underwent exchange of implants and 4 underwent transfemoral amputation due to recalcitrant infection and failure of soft tissue coverage. This equates to a limb salvage rate of 98.3%. The most common causative organisms remain staphylococcus species (47%) and polymicrobial infections (40%). We expand on the existing literature advocating for the use of silver-coated endoprosthetic reconstructions. We provide insights from the vast experience of a single surgeon when addressing patients with oncological and bone loss-related complex reconstruction problems.
The Australia and New Zealand Sarcoma Association established the Sarcoma Guidelines Working Party to develop national guidelines for the management of Sarcoma. We asked whether surgery at a specialised centre improves outcomes. A systematic review was performed of all available evidence pertaining to paediatric or adult patients treated for bone or soft tissue sarcoma at a specialised centre compared with non-specialised centres. Outcomes assessed included local control, limb salvage rate, 30-day and 90-day surgical mortality, and overall survival. Definitive surgical management at a specialised sarcoma centre improves local control as defined by margin negative surgery, local or locoregional recurrence, and local recurrence free survival. Limb conservation rates are higher at specialised centres, due in part to the depth of surgical experience and immediate availability of multidisciplinary and multimodal therapy. A statistically significant correlation did not exist for 30-day and 90-day mortality between specialised centres and non-specialised centres. The literature is consistent with improved survival when definitive surgical treatment is performed at a specialised sarcoma centre. Evidence-based recommendation: Patients with suspected sarcoma to be referred to a specialised sarcoma centre for surgical management to reduce the risk of local recurrence, surgical complication, and to improve limb conservation and survival. Practice point: Patients with suspected sarcoma should be referred to a specialised sarcoma centre early for management including planned biopsy.
Complex acetabular reconstruction for oncology and bone loss are challenging for surgeons due to their often hostile biological and mechanical environments. Titrating concentrations of silver ions on implants and alternative modes of delivery allow surgeons to exploit anti-infective properties without compromising bone on growth and thus providing a long-term stable fixation. We present a case series of 12 custom acetabular tri-flange and custom hemipelvis reconstructions (Ossis, Christchurch, New Zealand), with an ultrathin plasma coating of silver particles embedded between layers of siloxane (BioGate HyProtect™, Nuremberg, Germany). At the time of reporting no implant has been revised and no patient has required a hospital admission or debridement for a deep surgical site infection. Routine follow up x-rays were reviewed and found 2 cases with loosening, both at their respective anterior fixation. Radiographs of both cases show remodelling at the ilium indicative of stable fixation posteriorly. Both patients remain asymptomatic. 3 patients were readmitted for dislocations, 1 of whom had 5 dislocations within 3 weeks post-operatively and was immobilised in an abduction brace to address a lack of muscle tone and has not had a revision of their components. Utilising navigation with meticulous implant design and construction; augmented with an ultrathin plasma coating of silver particles embedded between layers of siloxane with controlled and long-term generation of silver ion diffusion has led to outstanding outcomes in this series of 12 custom acetabular and hemipelvis reconstructions. No patients were revised for infection and no patients show signs of failure of bone on growth and incorporation. Hip instability remains a problem in these challenging mechanical environments and we continue to reassess our approach to this multifaceted problem.
Avulsion of the proximal hamstring tendon origin can result in significant functional impairment, with surgical re-attachment of the tendons becoming an increasingly recognized treatment. The aim of this study was to assess the outcomes of surgical management of proximal hamstring tendon avulsions, and to compare the results between acute and chronic repairs, as well as between partial and complete injuries. PubMed, CINAHL, SPORTdiscuss, Cochrane Library, EMBASE, and Web of Science were searched. Studies were screened and quality assessed.Aims
Methods
This study aimed to identify patients receiving total hip arthroplasty (THA) for trauma during the peak of the COVID-19 pandemic in the UK and quantify the risks of contracting SARS-CoV-2 virus, the proportion of patients requiring treatment in an intensive care unit (ICU), and rate of complications including mortality. All patients receiving a primary THA for trauma in four regional hospitals were identified for analysis during the period 1 March to 1 June 2020, which covered the current peak of the COVID-19 pandemic in the UK.Aims
Methods
Total hip arthroplasty (THA) is a physically demanding procedure where the surgeon is subject to fatigue with increased energy expenditure comparable to exercise[1]. Robotic technologies have been introduced into operating rooms to assist surgeons with ergonomically challenging tasks and to reduce overall physical stress and fatigue[2]. Greater exposure to robotic assisted training may create efficiencies that may reduce energy expenditure[3]. The purpose of this study was to assess surgeon energy expenditure during THA and perceived mental and physical demand. 12 THAs (6 cadavers) randomized by BMI were performed by two surgeons with different robotic assisted experience. Surgeon 1 (S1) had performed over 20 robotic assisted THAs on live patients and Surgeon 2 (S2) had training on 1 cadaver with no patient experience. For each cadaver, laterality was randomized and manual total hip arthroplasty (MTHA) was performed first on one hip and robotic assisted total hip arthroplasty (RATHA) on the contralateral hip. A biometric shirt collected surgeon data on caloric energy expenditure (CEE) throughout acetabular reaming (AR) and acetabular implantation (AI) for each THA procedure. Surgeon mental and physical demand was assessed after each surgery. Scores were reported from 1–10, with 10 indicating high demand. A paired sample t-test was performed between MTHA and RATHA within each surgeon group with a confidence interval of (α =0.05).Introduction
Methods
Hip fracture care is complex multi-disciplinary. We hypothesise that quality of care is affected by variance in resources between ‘in-hours’ (Monday-Friday, 0800–1700) and ‘out-of-hours’ services. This prospective multicentre national cohort study assessed quality of care by evaluating adherence to the evidence-based Scottish Standards of Care for Hip Fracture Patients. Data was collected by the Scottish Hip Fracture Audit for 15174 patients admitted to any of 22 Scottish hospitals from January 2014-April 2018. 11197/15174 (73.8%) patients were admitted out-of-hours. They were significantly less likely to meet the following Standards: ED Big-6-Bundle (OR 0.85, p= 0.002); Time in ED <4 hours (OR 0.76, p< 0.001); avoidance of repeated fasting (OR 0.80, p< 0.001), and avoidance of prolonged fluid fasting (OR 0.83, p< 0.001). Out-of-hours admissions were more likely to receive: geriatric assessment <3 days (OR 1.16, p< 0.001); OT input <3 days (OR 1.10, p= 0.013), and PT input <2 days (OR 1.44, p< 0.001). There were no significant differences for: Time to Theatre <36 hours; Inpatient Care Bundle <24 hours, and Post-op Day 1 Mobilisation. Quality of hip fracture care is affected by time of admission. ED care is poorer out-of-hours, which may reflect limited resources, and out-of-hours admissions are more likely to be excessive fasted excessively. Weekday in-hours admissions are less likely to receive geriatric and allied health professional input in the days following admission, which may reflect the reduced weekend services. Examination of out-of-hours service organisation is required for the pursuit of consistent, equitable care for hip fracture patients.
Traditional treatment for end-stage ankle arthritis has been ankle arthrodesis, however ankle arthroplasty is becoming an accepted alternative. The Zenith Ankle (Corin, UK) is 3rd generation implant with a mobile bearing design. In the NJR 2016 report, the Zenith was the commonest ankle prosthesis implanted in the UK. However, compared to other ankle implants, there's little published data on its performance and survival. The aim of this study was to analyse outcome in a consecutive series from a non-designer centre. We conducted a retrospective review of a consecutive series of 118 Zenith Ankle replacements implanted in our Unit (December 2010 to May 2016). Data was collected from our National Joint Registry entries, research databases, patient notes, PACS and PROMS.Introduction
Method
In a society whereby the incidence of obesity is increasing and medico-legal implications of treatment failure are more frequently ending with the consulting doctor, clarity is required as to any restrictions placed on common orthopaedic implants by manufacturing companies. The aim of this study was to identify any restrictions placed on the commonly used femoral stem implants in total hip replacement (THR) surgery, by the manufacturers, based on patient weight. The United Kingdom (UK) National Joint Registry (NJR) was used to identify the five most commonly used cemented and uncemented femoral stem implants during 2012. The manufacturing companies responsible for these implants were asked to provide details of any weight restrictions placed on these implants. The Corail size 6 stem is the only implant to have a weight restriction (60Kg). All other stems, both cemented and uncemented, were free of any restrictions. Fatigue fracture of the femoral stem has been well documented in the literature, particularly involving the high nitrogen stainless steel cemented femoral stems and to a lesser extent the cemented cobalt chrome and uncemented femoral stems. In all cases excessive patient weight leading to increased cantilever bending of the femoral stem was thought to be a major factor contributing to the failure mechanism. From the current literature there is clearly an association between excessive patient weight and fatigue failure of the femoral stem. We suggest avoiding, where possible, the insertion of small stems (particularly cemented stems) and large offset stems (particularly those with a modular neck) in overweight patients.
The ASR™ Articular Surface Replacement and ASR™ XL Metal-on-Metal systems were recalled due to high revision rates at five years. A worldwide clinical follow-up of patients was initiated. This paper summarizes current findings in South Africa (SA) in comparison with those outside SA (OSA). Patients were followed annually, or until revision, from 10 clinical centers worldwide. Data collected includes demographic, surgical, radiographic, blood metal ion levels, and patient reported outcome measures (PROM).Introduction:
Methods:
The aim of this study was to identify the rate of complications of total ankle replacement in a single Centre to help with informed patient consent. Between 2008 and 2012, 202 total ankle replacements (TARs) were performed by 4 surgeons at our Institute. Data was collected on all patients; demographics, arthritic disease, pre-operative deformity, prosthesis and all early and late complications.Introduction:
Methods:
Transportation media and injection protocol have implications for the viability of MSCs used for intra-lesional treatment of tendon injuries. Every effort should be made to implant cells within 24h of laboratory re-suspension, using a needle bore larger than 21G. Intra-lesional implantation of autologous mesenchymal stem cells (MSCs) has resulted in significant improvements in tendon healing in experimental animal models. Intra-tendinous injection of MSCs into naturally-occurring equine tendon injuries has been shown to be both safe and efficacious1 and these protocols can assist in the translation to the human. Efficient transfer of cells from the laboratory into the tissue requires well validated techniques for transportation and implantation. The aim of this study was to determine the influence of transport media and injection procedure on cellular damage.Summary Statement
Introduction
Wear particles from joint replacements may result in loosening and periprosthetic osteolysis. Interference with systemic macrophage trafficking to the implant, modulation of macrophage phenotype from M1 to M2, and inhibition of NFκB may mitigate these adverse effects. Joint replacement of the lower extremity is highly successful in alleviating pain, and improving ambulation and function. However, prosthetic byproducts of different materials, in sufficient amounts, may lead to loosening and periprosthetic osteolysis. Debris from polymers (such as polyethylene and PMMA), metals and ceramics are capable of inciting an adverse tissue reaction, which is orchestrated by cells of the monocyte/macrophage lineage. Three experimental approaches have been taken by our group to potentially mitigate the adverse biological sequela of particle disease. These include: 1) interfering with ongoing migration of monocyte/macrophages to the implant site by inhibiting the chemokine system 2) altering the functional activities of local macrophages by converting pro-inflammatory M1 macrophages to an anti-inflammatory pro-tissue healing M2 phenotype and 3) modulating the production and release of pro-inflammatory cytokines, chemokines and other potentially harmful factors by inhibiting the key transcription factor NFκB.Summary
Introduction
This work raises the potential of utilizing stem cells to catalyze cartilage regeneration by a minimal number of neonatal chondrocytes via controlling cell distribution in 3D matrices, and may solve the challenge of scarce donor availability associated with cell-based therapy. Cartilage loss is a leading cause of disability among adults and represents a huge socio-economical burden. Allogeneic neonatal articular chondrocytes (NChons) is a promising cell source for cartilage regeneration because these cells are highly proliferative, immune-privileged, and readily produce abundant cartilage matrix. However, scarce donor availability for NChons greatly hinders their broad clinical application. Besides their ability to differentiate into different tissue types, stem cells may contribute to tissue regeneration through the secretion of paracrine factors. Here we examined the potential for using a minimal number of NChons to catalyze cartilage tissue formation by co-culturing them with adipose-derived stem cells (ADSCs) in 3D biomimetic hydrogels.Summary Statement
Introduction
The surgical treatment options for patients who have sustained an intra-capsular hip fracture can vary depending on a number of patient and fracture related factors. Currently most national guidelines support the use of cemented prostheses for patient undergoing hemi-arthroplasty surgery. Uncemented prostheses are commonly used for a variety of indications including those patients who have significant medical co-morbidities. To determine whether cemented hemi-arthroplasty is associated with a higher post operative mortality when compared to uncemented procedures. Data was extracted from the Scottish SMR01 database from 01/04/1997 from all patients who were admitted to hospital after sustaining a hip fracture. We investigated mortality at day 1, 2, 4, 7, 30, 120 and 1 year from surgery vs. that on day 0. In order to control for the effects of confounding variables between patients cohorts, 12 case-mix variable were used to construct a multivariable logistic regression analysis model to determine the independent effect of prosthesis fixation method. There were 64,979 patients were included in the study. Mortality for osteosynthesis of extra-capsular fractures was consistently lower when compared to that for surgical procedures for intra-capsular fractures. At day 0, uncemented hemi-arthroplasty operations had a lower associated mortality (p<0.001) when compared to cemented implant designs. Unadjusted figures showed an increased mortality equal to 1 extra death per 424 procedures. By day 1 this had become 1 extra death per 338 procedures. By day 7 cumulative mortality was less for cemented than for uncemented procedures though this did not reach significance until day 120. When compared to uncemented fixation techniques, cemented hemiarthroplasty is associated with a higher mortality in the immediate postoperative period. However, by day 120 and beyond the trend is reversed.
Decompression is the gold standard surgical technique in patients with symptomatic spinal stenosis not responding to conservative management. We present an audit of outcomes in a population of patients undergoing this procedure over a four year period. All patients undergoing lumbar decompression were assessed preoperatively and between 4 and 12 months postoperatively using the Oswestry Disabilty Index (ODI %), pain scale (0–10) and patient satisfaction. The patient's age, the number of levels decompressed and the incidence of complications were recorded.Introduction
Method