Single-event multilevel surgery (SEMLS) is the standard orthopaedic treatment for gait abnormalities in children with diplegic cerebral palsy (CP). The primary aim of this study was to report the long-term functional mobility of these patients after surgery. The secondary aim was to assess the relationship between functional mobility and quality of life (QoL). Patients were included if they met the following criteria: 1) diplegic CP; 2) Gross Motor Function Classification System (GMFCS) I to III; 3) SEMLS at age ≤ 18. A total of 61 patients, mean age at surgery 11 years eight months (SD 2y 5m), were included. A mean of eight years (SD 3y 10m) after SEMLS, patients were contacted and asked to complete the Functional Mobility Scale (FMS) questionnaire over the telephone and given a weblink to complete an online version of the CP QOL Teen. FMS was recorded for all patients and CP QOL Teen for 23 patients (38%).Abstract
Objectives
Methods
Accurate orientation of the acetabular component during a total hip replacement is critical for optimising patient function, increasing the longevity of components, and reducing the risk of complications. This study aimed to determine the validity of a novel VR platform (AescularVR) in assessing acetabular component orientation in a simulated model used in surgical training. The AescularVR platform was developed using the HTC Vive® VR system hardware, including wireless trackers attached to the surgical instruments and pelvic sawbone. Following calibration, data on the relative position of both trackers are used to determine the acetabular cup orientation (version and inclination). The acetabular cup was manually implanted across a range of orientations representative of those expected intra-operatively. Simultaneous readings from the Vicon® optical motion capture system were used as the ‘gold standard’ for comparison. Correlation and agreement between these two methods was determined using Bland-Altman plots, Pearson's correlation co-efficient, and linear regression modelling.Abstract
Objectives
Methods
To assess if older symptomatic children with club foot deformity differ in perceived disability and foot function during gait, depending on initial treatment with Ponseti or surgery, compared to a control group. Second aim was to investigate correlations between foot function during gait and perceived disability in this population. In all, 73 children with idiopathic club foot were included: 31 children treated with the Ponseti method (mean age 8.3 years; 24 male; 20 bilaterally affected, 13 left and 18 right sides analyzed), and 42 treated with primary surgical correction (mean age 11.6 years; 28 male; 23 bilaterally affected, 18 left and 24 right sides analyzed). Foot function data was collected during walking gait and included Oxford Foot Model kinematics (Foot Profile Score and the range of movement and average position of each part of the foot) and plantar pressure (peak pressure in five areas of the foot). Oxford Ankle Foot Questionnaire, Disease Specific Index for club foot, Paediatric Quality of Life Inventory 4.0 were also collected. The gait data were compared between the two club foot groups and compared to control data. The gait data were also correlated with the data extracted from the questionnaires.Aims
Methods
We describe a novel method to encourage children to weight-bear after frame surgery using a whoopee cushion; the objective of this study is to assess the amount of force taken though a limb using this method. The amount force is required to activate the whoopee cushion is measured when a subject takes weight though a whoopee cushion on a force plate. The speed of the foot in vertical and horizontal planes is assessed with motion analysis to correlate this to the activation of the cushion and is assessed under different conditions, and with different whoopee cushionsPurpose
Design/participants
The purpose of this study was to assess the accuracy of three-dimensional camera technology when monitoring deformity correction by an Ilizarov frame and to compare it to manual measurements. A model consisting of an Ilizarov frame built around an artificial tibia and fibula was used with retro-reflective markers placed on the frame and bones to allow for the positions of each to be detected by the camera system. Measurements made by the camera system were compared to measurements taken manually. In the assessment of frame lengthening, the camera system average error was 2% (SD 2%) compared to 7% (SD 6%) for manual measurement. In the assessment of bone lengthening, the camera system average error was 4% (SD 4%) compared to 34% (SD 8%) for manual measurement. The technology also demonstrated good accuracy in the measurement of angular deformity changes.Purpose
Methods and Results
Three-dimensional motion of the lower limbs was measured using gait analysis. Transverse plane kinematics, including hip rotation and foot progression angles were recorded.