Spontaneous osteonecrosis of the knee (SONK) mainly affects the medial femoral condyle, would be a good indication for UKA. The primary aim of this study was to assess the clinical, functional and radiographic outcomes at middle to long-term follow-up, of a consecutive series of fifty UKA used for the treatment of SONK. The secondary aim was to assess the volume of necrotic bone and determine if this influenced the outcome. We reviewed 50 knees who were treated for SONK. Patients included ten males and 38 females. The mean age was 73 years (range, 57 to 83 years). The mean height and body weight were, respectively 153 cm (141 ∼171 cm) and 57 kg (35 ∼75kg). All had been operated on using the Oxford mobile-bearing UKA (Zimmer-Biomet, Swindon, United Kingdom) with cement fixation. The mean follow-up period was 8.4 years (range, 4 to 15years). We measured the size (width, length and depth) and the volume to be estimated (width x length x depth) of the necrotic bone mass using MRI in T1-weighted images. The clinical results were evaluated using the Knee Society Scoring System (KSS) and Oxford Knee Score (OKS). The flexion angle of the knee was evaluated using lateral X-ray images in maximum flexion.Aims
Patients and Methods
There have been only a few reports about the efficacy of postoperative cryotherapy following total hip arthroplasty (THA), and past studies have described that local cooling is efficacy for pain relief. The purpose of this study is whether the continuous local cooling following THA is effective for pain relief and the reduction of blood loss, swelling, and the duration of hospital stay. Thirty-eight patients (39 hips) underwent primary cementless THA for osteoarthritis and were divided into a cryotherapy group (30 subjects; from Apr. 2013 to Oct. 2013) and a control group (9 subjects; from Nov. 2012 to Mar. 2013). In the cryotherapy group, a continuous cooling pad was applied on the surgical wound and the thigh with a cloth anchor band (CF-3000, Sigmax, Japan) with the cooling temperature set to a constant 5°C for 72 hours immediately after surgery. Blood was collected on postoperative days 1,4,7,14, and 21 to determine Hb, CK, and CRP levels. Postoperative pain of the hip was scored by using a visual analog scale questionnaire on postoperative days 1 to 28. Total doses of selecoxib and dicrofenac sodium used for pain relief were measured. The circumference of patellar superior border was measured on postoperative days 4,7,14, and 28. The unpaired t-test was used for blood tests as well as for comparisons between the cryotherapy and control groups, and the Mann-Whitney U test was used for the analysis of age, BMI, approach of the surgery, analgesic use, pain scores, the circumference of the thigh and the duration of hospital stay.[Purpose]
[Materials and Methods]
Surgical-site-infections (SSI) prolong hospital stay, and they are leading nosocomial cause of morbidity and a source of excess cost. Recently, a waterless hand-rubbing protocol containing aqueous 1% chlorhexidine gluconate was developed before surgery, but there is no literature in orthopaedic surgery. The aim was to compare the SSI rates between waterless hand-rubbing and traditional hand-scrubbing protocol. STUDY 1: A total of 996 consecutive patients who underwent orthopaedic surgery between August 1, 2012 and January 31, 2014, were screened for SSI within 30 days after surgery. 500 patients from August 1, 2012 to April 1, 2013 were used by traditional hand-scrubbing, and 496 patients from June 1, 2013 to January 1, 2014 were by waterless hand-rubbing. STUDY 2: The twelve operating room staff members were randomly recruited, and the participants were assigned equally to use either a traditional hand-scrubbing protocol or a waterless hand-rubbing on 2 separate days. Washing times were recorded and microorganisms on hands were sampled on bacterial culture plates. Two days after sampling, the grown colonies were counted.[Introduction]
[Materials and Methods]
The purpose of this study was to examine if Sugioka's transtrochanteric rotational osteotomy (TRO) of the femoral head could be a valid option in treating idiopathic osteonecrosis of the femoral head. Thirty-two TROs performed in 29 patients between 1985 and 2006 were studied. Patient age at operation ranged from 16 to 56 years (average, 36 years). Thirteen hips were in women and 19 hips in men. Height was 165 cm and weight 63 kg (Body Mass Index 23) on average. Risk factors were corticosteroid use in 18 hips and excessive alcohol consumption in 15 hips (2 of them had both backgrounds), while neither of them was found with 1 hip. Bilateral hips were affected in 19 patients and 3 of them underwent bilateral TROs sequentially. The femoral head was rotated anteriorly in 26 hips and posteriorly in 6 hips. For fixation of the osteotomy site, large femoral screws had been used till 1995 (Group 1, 9 hips), and since 1996 an AO angle plate or a compression hip screw has been used (Group 2, 13 hips). Since 2003, pre-operative planning was performed more meticulously and the distal part of the joint capsule was cut after osteotomy as described by Atsumi (Group 3, 10 hips). The average follow-up period was 6.5 years (range, 2 to 21 years).Introduction
Methods
Osteonecrosis of the femoral head (ONFH) is one of the most serious complications associated with corticosteroid therapy. In patients with ONFH, collapse of the femoral head often occurs and causes severe hip pain and impaired hip joint function. Despite the widely spread use of corticosteroids for treating various diseases and a known association between prevalence of ONFH and daily dose of corticosteroids, the pathomechanism for the development of ONFH has not been identified. Since hepatic cytochrome P4503A (CYP3A) is a predominant enzyme responsible for metabolizing corticosteroids and its activities varies more than 10-fold, low hepatic CYP3A activity leads to a remarkable increase of corticosteroid levels and its effect. We have previously reported that hepatic CYP3A levels are significantly lower in patients with corticosteroid-induced ONFH than that in control patients and patients with alcohol-related ONFH and that hepatic CYP3A activity inversely correlated with the incidence of osteonecrosis and extent of the necrotic area caused by the same dose of corticosteroids in a rabbit model, suggesting possible prevention of the corticosteroid-induced osteonecrosis by adjusting corticosteroid dose based on the level of individual hepatic CYP3A activity prior to corticosteroid therapy. To examine hepatic CYP3A activity, measuring clearance of administrated midazolam (MDZ) is a reliable method, as shown by the significant correlations between the clearance of midazolam and hepatic CYP3A levels measured by biopsy and the clearance of other CYP3A-specific substrates. However, the method is invasive and time consuming for measuring clearance of administrated MDZ, needing multiple blood samplings over half a day for each subject. The aim of this study was to develop the simple, safe and noninvasive methods for measuring the level of hepatic CYP3A activity, which is applicable to prevent the occurrence of corticosteroid-induced osteonecrosis prior to corticosteroid therapy. Thirty seven healthy male (n=20) and female (n=17), volunteers who had a mean age of 27 years received single oral administration of a small quantity of midazolam (50 mg/kg) and concentrations of total midazolam and its principal metabolite, 1-hydroxymidazolam (1-OH-midazolam), in each plasma at 15, 30, 45, 60, and 90 minutes and 2, 3, 4, 6, 9 and 12 hours post-drug administration were measured. Secondarily, the assessment of the Observer's Assessment of Alertness/Sedation (OAA/S) Scale was also used during the 12-hour post-administration period.Introduction
Methods
The introduction of porous tantalum metal (Trabecular Metal; Zimmer, Warsaw, IN) for acetabular component fixation in total hip arthroplasty has shown optimum fixation qualities and “gap filling” effect. Recently, trabecular metal was introduced in tibial component for total knee prosthesis, however its effect on the bone mineral density (BMD) was not reported. The purpose of this study was to compare the BMD of proximal part of the tibia between trabecular metal and another cemented tibial component. 31 knees receiving trabecular metal tibial component and 33 knees receiving cemented tibial component (PFC Sigma RP, Depuy, Warsaw, IN) had dual energy x-ray absorptiometry (DEXA) scans at preoperatively and 3 weeks, 3, 6, 12, 18, 24 months post-operatively. To assess peri-prosthetic BMD, three regions of interest (ROI) were measured for each case. They were medial aspect (ROI 1), center aspect (ROI 2) and lateral aspect (ROI 3) of tibia. Average follow up period was 1.8 (range: 1.5 to 2) years. In both groups, BMD in tibia decrease postoperatively. Comparing postoperative decrease of BMD in lateral aspect of tibia (ROI 3) between both groups, it was significantly less in trabecular metal component (−0.09 g/cm2 +/−0.27) than cemented tibial component (−0.31 g/cm2 +/− 0.21) (p=0.0007). We conclude that trabecular metal tibial component showed a favorable effect on BMD of proximal part of the tibia after total knee arthroplsaty.
Cup orientation of total hip arthroplasty (THA) is critical for dislocation, range of motion, polyethylene wear, pelvic osteolysis, and component migration. But, substantial error under manual technique has been reported. Therefore, various navigation systems were introduced to reduce outliers. CT based navigation (CTN) was reported to reduce outliers in cup orientation. Recently, a noble technique, fluoroscopy-CT-based navigation (FCTN), has recently been developed using 2D-3D matching technique. Because of much less registration points, FCTN might be friendly to MIS THA and cases with sever bone deformity. Between October 2006 and April 2008, 33 THAs were performed through MIS approach with navigations. We prospectively randomized those into two groups, CTN and FCTN groups. We implanted cementless hemispherical cups in 18 hips using CTN (VectorVision CT Hip 3.1) and in 15 hips using FCTN (VectorVision CT Hip 3.5). For all the patients, volumetric post-operative CT scan was performed to measure 3D cup orientation. using 3D image-processing software (JMM, Japan). The difference from target angles of anteversion was 2.7 ± 2.4 degrees in FCTN group, and 12.1 ± 5.7 degrees in CTN group (p <
0.001). The absolute value of difference from target angles of inclination was 2.7 ± 2.4 degrees in FCTN group, and 6.5 ± 4.5 degrees in CTN group (p = 0.006). FCTN does not need surface registration around acetabulum, which is great advantage to MIS THA. Our study clearly showed that FCTN significantly improved a cup orientation to CTN.
Highly closslinked polyethylene has been developed to reduce polyethylene wear and to expect the longevity of THA. In daily activity of patients, total hip prostheses repeatedly suffer impact loading. However, the mechanical properties, especially impact load transmission, are not well investigated and the viscoelasticity might influence the loosening of cemented all-polyethylene cup. In this study, the impact load transmission through the complex of polyethylene cup, ceramic ball and metallic femoral stem was investigated. Impact compressive tests on the complex were performed using Hopkinson pressure bar apparatus. Conventional and highly crosslinked polyethylene cups of three different sizes (40mm, 50mm, 56mm)were compared. The impact load was applied either from the cup or from the stem. The impact load transmission ratio (ILTR) i.e. the ratio of the magnitude of transmitted load to that of incident one was investigated. The loading pulse profiles were theoretically calculated based on the one dimensional elastic wave propagation theory and were compared with experimental results. The ILTR was independent of the cup size in all experimental conditions. When the impact load was applied from the cup, the ILTR was not different between two types of polyethylene. On the other hand, when the impact load was applied from the stem, the ratio was greater than the previous loading condition, while the ratio of crosslinked polyethylene was significantly lower than that of conventional one (p <
0.05). The theoretically predicted stress pulse profiles were well correlated to the experimental ones. The lower ILTR in highly crosslinked polyethylene is considered to be due to lower stiffness. These mechanical properties increase the deformity of the cup and may cause the loosening of the cup. These results indicated that the ILTR was not different among cup sizes, while the ratio was significantly affected by the loading conditions and the type of polyethylene.
Highly crosslinked polyethylene has been developed to reduce polyethylene wear and to expect the longevity of THA. In daily activity of patients, total hip prostheses repeatedly suffer impact loading. However, the mechanical properties, especially impact load transmission, are not well investigated and the viscoelasticity might influence the loosening of cemented all-polyethylene cup. In this study, the impact load transmission through the complex of polyethylene cup, ceramic ball and metallic femoral stem was investigated. Impact compressive tests on the complex were performed using Hopkinson pressure bar apparatus. Conventional and highly crosslinked polyethylene cups of three different sizes (40mm, 50mm, 56mm) were compared. The impact load was applied either from the cup or from the stem. The impact load transmission ratio (ILTR) i.e. the ratio of the magnitude of transmitted load to that of incident one was investigated. The loading pulse profiles were theoretically calculated based on the one dimensional elastic wave propagation theory and were compared with experimental results. The ILTR was independent of the cup size in all experimental conditions. When the impact load was applied from the cup, the ILTR was not different between two types of polyethylene. On the other hand, when the impact load was applied from the stem, the ratio was greater than the previous loading condition, while the ratio of crosslinked polyethylene was significantly lower than that of conventional one (p <
0.05). The theoretically predicted stress pulse profiles were well correlated to the experimental ones. The lower ILTR in highly cross linked polyethylene is considered to be due to lower stiffness. These mechanical properties increase the deformity of the cup and may cause the loosening of the cup. These results indicated that the ILTR was not different among cup sizes, while the ratio was significantly affected by the loading conditions and the type of polyethylene.
Acetabular revision in patients with bone deficiency is often difficult because of the poor quality and quantity of the acetabular bone stock. The purpose of this study was to evaluate the midterm clinical and radiographic outcomes of acetabular revision with use of an impaction bone-grafting technique and a cemented polyethylene cup.
One hip had a repeat revision. Radiographic analysis that had not been revised showed loosening in four hips. All these four hips were treated by bulk bone graft covering more than 50% of cups. Kaplan-Meier analysis demonstrated a prosthetic survival rate, with aseptic loosening as the end point, of 72% at fourteen years and, with revision as the endpoint, of 100% at ten years and 83% at fourteen years. Impaction bone-grafting was an excellent option to manage acetabular revision surgery. However, excessive bulk bonegraft should not be used.
Polyethylene wear is the most important risk factor affecting the durability of total knee arthroplasty. We developed a new method of measuring wear of the tibial polyethylene insert in total knee arthroplasty (TKA) on standard standing radiographs.
By 1998, 10 patients had undergone 12 revision total knee arthroplasties at our institute. One patient died three weeks after surgery due to cerebral infarction, leaving 11 knees of nine patients for evaluation. Average follow-up was 4.8 years (1 to 9 years). All components were subjected to revision surgery in five knees, the tibial tray and insert in four knees, and only the insert in two knees. Patients were evaluated with clinical examinations, radiographs, and the Knee Society Clinical Rating System. After revision surgery, the Knee Scores and ROMs were restored to almost the same level as just after the first TKA. Re-revision was performed on two patients, one 103 months and the other 82 months after revision TKA. In those two patients, huge bone loss of the proximal tibial canal was filled with cement without bone graft. The other patients, however whose tibial trays were fixed with cement on adequate grafted bone obtained good results. The femoral components that were not treated with revision surgery despite small flaws or scratches due to wear and tear of the tibial insert did not cause marked wear of the new tibial insert.
The benefit of mobile-bearing mechanism in total knee arthroplasty (TKA) has been controversial. The aim of this paper is to analyse the rotation of polyethylene (PE) and its effect on the range of motion (ROM) in mobile-bearing, posterior stabilised TKA (LPS-Flex™, Zimmer Co. Ltd.). Thirty-four consecutive PS-Flex™ TKAs (28 patients) were analysed. Three tantalum markers were inserted in the PE and the tibia (one for medial side and two for lateral side; total six markers). The rotation of the PE and the tibia was analysed in fluoroscopically-controlled radiograph taken at one years in full extension, 90 degrees flexion and passive maximum flexion. The markers in the tibia were identifiable in 19 knees and the analysis was based on these knees. The tibia rotated internally relative to the femur by 7.1± 5.2 degrees (mean ± SD, range −1 to 20 degrees). The amount of tibial rotation has no correlation to ROM. The rotation of the PE relative to the femur was unpredictable showing three knees with external rotation and four knees without rotation (Average; 4.0 ± 4.5 degrees internal rotation). The rotation of the PE on the tibia was 4.2± 5.2 degrees and seven knees (37 %) showed no rotation and 12 knees (63 %) showed less than 5 degrees rotation. There was a positive correlation between the amount of PE rotation on the tibia and ROM, which approached to statistical significance (p = 0.0684). This study has demonstrated that the rotation of the PE on the tibial tray is generally small (<
5 degrees). Because not tibial internal rotation but PE movement on the tibia correlated to ROM, the essential benefit of the mobile-bearing mechanism could be to compensate the rotational mismatch between the components rather than to reproduce normal knee kinematics.
The new 3-Dimensional (3D) polyethylene wear measurement software GAWDI (Genetic Algorithm for Wear Detect Instrument) was developed to evaluate in vivo movement of the femoral head into the polyethylene liner. It enabled to detect 3D position of femoral head against polyethylene socket from two radiographs. Inter observer error of this system was 0.09 mm, intra observer error was 0.08 mm. Fifteen patients after THA was taken anterior-posterior (AP) and semi-lateral radiographs in both standing and supine position one year post operation. The difference of the 3D position of the femoral head was not observed between standing and supine position. However 8.1 degrees (mean) and 0.2 to 16.5 degrees (range) pelvic tilt was observed between these positions. 0.8 mm (mean) difference was observed by 2-Dimensional measurement system although no difference was observed by 3D system. Small separation between head and socket was observed in a few patients. However the influence of pelvic tilt was main origin of the difference between 2D and 3D measurement methods.