Mobile-bearing knee prostheses have been designed in order to provide less constrained knee kinematics compared to fixed-bearing prosthesis. Currently, there is no evidence to confirm the superiority of either of the two implants with regard to walking performances. It has been shown that subjective outcome scores correlate poorly with real walking performance and it has been recommended to obtain an additional assessment of walking ability with objective gait analysis. We assessed recovery after total knee arthroplasty (TKA) with mobile- and fixed-bearing between patients during the first postoperative year, and at 5 years follow-up, using a new objective method to measure gait parameters in real life conditions.INTRODUCTION
OBJECTIVES
The FIRST knee prosthesis (Free Insert in Rotation Stabilized in Translation, Symbios SA) is a new ultra congruent, postero-stabilized total knee arthroplasty (TKA) with a mobile bearing expected to reduce significantly polyethylene wear, to improve the range of motion and the overall stability of the knee while ensuring a physiological ligament balance. We compared subjective and really objective results of this new TKA with two other widespread models of TKA. A clinical prospective monocentric cohort study of 100 consecutive patients (47–88 yrs) undergoing a FIRST TKA for primary osteoarthritis is currently being done. Pre- and post-operative follow-ups (6 weeks, 4,5 months and 1 year) are done with well-recognized subjective evaluations (EQ-5D and WOMAC scores) and semi-objective questionnaires (KSS score and radiography evaluation) as well as with a really objective evaluation using gait parameters from 6 walking trials, performed at different speeds with an ambulatory in field gait analysis system (Physilog®, BioAGM CH). The outcomes after one year of follow-up of 32 FIRST TKA are compared to 29 NexGen® postero-stabilized TKA (Zimmer Inc) with a fixed bearing and to 26 NexGen® TKA with a mobile bearing using the same methods. The gait cycle time of the FIRST TKA was statistically significantly shorter at normal speed of walk, as well as double-support periods, as compared to both standard models. The normal walking speed was significantly higher with faster swing speed and stride lengths for the new TKA. Significantly better coordination scores were observed at normal walking speed for the FIRST TKA as compared to the fixed-bearing TKAs. The FIRST TKA showed statistically significantly better really objective outcomes in terms of gait after one year of follow-up and similar subjective and semi-objective evaluations compared to two widespread TKA designs.
Ten patients were studied using an ambulatory gait device (Physilog®). Each participant was asked to perform two walking trials of 30m long at 3 different speeds and to complete an EQ-5D questionnaire, a WOMAC and Knee Society Score. Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. The outcomes of the eight patients undergoing total knee arthroplasty, recorded pre-operatively and post-operatively at 6 weeks, 3 months, 6 months and 1 year were compared to 2 age-matched healthy subjects.
This randomized controlled double-blind study included to date 14 patients: the gait signatures of four patients with mobile-bearing were compared to the gait signatures of nine patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.
The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration.