Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 69 - 69
1 Sep 2012
Hirokawa S Fukunaga M Tsukamoto M Akiyama T Horikawa E Mawatari M
Full Access

The objective of this study is to determine the knee joint forces when rising from a kneeling position. We have developed a new type of knee prosthesis which is capable of attaining Japanese style sitting. To run the simulations and experiments needed to assess the performance of this prosthesis, it is necessary to know what forces act on the knee during deep flexion. Because these data are lacking, we created a 2D mathematical model of the lower leg to help determine knee joint forces during deep flexion. Healthy subjects of ten males (age of 25±4years, height of 170.3±9.1cm, and weight of 67.0±22.2kg) and five females (25±3years, 161±7.1cm, 47.7±6.2kg) participated in the experiment. Ground reaction force and joints angles were measured using a force plate and a motion recording system respectively. The collected data were entered into our mathematical model, and the muscle forces and the knee joint forces were calculated. To verify our model, we first used it to run simulation of middle and high flexions of the knee joint. In vivo data for these actions are available in the literature, and the results from our simulation were in good agreement with these data. We then collected the data and run simulation when rising from a kneeling position under the conditions shown in Fig. 1. They were a) double leg rising (both legs are aligned) without using the arms, b) ditto but using the arms, c) single leg rising (legs are in the front and the rear respectively) without using the arms, and d) ditto but using the arms. We obtained the following results. The statistics of the maximum values on the single knee joint for each condition were; a) Fmax=5.1±0.4 [BW: (force on the knee joint)/(body weight)] at knee flexion angle of Q=140±8°, b) Fmax=3.2±0.9[BW] at Q=90±10°, c) Fmax-d=5.4±0.5[BW] at Qd=62±20° for the dominant leg and Fmax-s=3.0±0.5[BW] at Qs=138±6° for the supporting leg respectively, and d) Fmax-d=3.9±1.5[BW] at Qd=70±17° for the dominant, and Fmax-s=2.1±0.5 [BW] at Qs=130±11° for the supporting. We may conclude that the single leg rising should be recommended since the maximum knee joint force did not become large as long as the knee was at deep flexion. The values introduced in this study could be used to assess the strength of the knee prosthesis at deep flexion. To obtain more realistic values of the joint forces, it is necessary to determine the ratio of the forces exerted by the mono-articular and the bi-articular joint muscles


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 102 - 102
1 Nov 2021
Forriol F
Full Access

The knee joint has also a periarticular adipose tissue, which is known as Hoffa's fat pad (IPFP). IPFP has a dual function in the joint it reduces the concentration of Nitric Oxide, the release of glycosaminoglycans and the expression of MMP1 in the cartilage, but it also contains MSC and macrophages. Our hypothesis is that synovial fluid contains elements, not all of which are understood, which act as messengers and alter the “homeostasis” of the knee and the metabolism of all the cellular components of the joint, including the MSC of Hoffa's fat pad, thus making them another piece in the puzzle as far as OA of the knee is concerned. The IPFP of 37 patients with OA and 36 patients with ACL rupture were analyzed. Isolation, primary culture, and a functional and proteomic study of MSCs from IPFP were performed. Our results show that OA of the knee, in its more severe phases, also affects the MSC's of IPFP, which is a new actor in the OA degenerative process and which can contribute to the origin, onset and progression of the disease. A differential protein profile between OA and ACL patients were identified. Infrapatellar pad should be regarded as an adipose tissue with its own characteristics and it´s also able to produce and excrete important inflammatory mediators directly into the knee joint


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 80 - 80
7 Aug 2023
Liu A Qian K Dorzi R Alabdullah M Anand S Maher N Kingsbury S Conaghan P Xie S
Full Access

Abstract. Introduction. Knee braces are limited to providing passive support. There is currently no brace available providing both continuous monitoring and active robot-assisted movements of the knee joint. This project aimed to develop a wearable intelligent motorised robotic knee brace to support and monitor rehabilitation for a range of knee conditions including post-surgical rehabilitation. This brace can be used at home providing ambulatory continuous passive movement obviating the need for hospital admissions. Methodology. A wearable sensing system monitoring knee range of motion was developed to provide remote feedback to clinicians and real-time guidance for patients. A prototype of an exoskeleton providing dynamic motion assistance was developed to help patients complete their exercise goals and strengthen their muscles. The accuracy and reliability of those functions were validated in human participants during exercises including knee flexion/extension (FE) in bed and in chair, sit-to-stand and stand-to-sit. Results. The knee FE measurement from the sensing system showed high accuracy (correlation coefficient of 0.99°) in human participants. The real-time FE data during exercises showed that the desired exoskeleton rotation fitted well with the participant's knee rotation. This indicated the exoskeleton could coordinate with the participant's knee motion by providing consistent motion assistance. The development of user interfaces to provide feedback is currently underway. Conclusion. A wearable robotic knee brace to monitor and support knee rehabilitation exercises was successfully developed. Further development of this device with the use of artificial intelligence has the potential to aid patient rehabilitation in a variety of knee conditions


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 97 - 97
11 Apr 2023
Milakovic L Dandois F Fehervary H Scheys L
Full Access

This study aims to create a novel computational workflow for frontal plane laxity evaluation which combines a rigid body knee joint model with a non-linear implicit finite-element model wherein collateral ligaments are anisotropically modelled using subject-specific, experimentally calibrated Holzpfel-Gasser-Ogden (HGO) models. The framework was developed based on CT and MRI data of three cadaveric post-TKA knees. Bones were segmented from CT-scans and modelled as rigid bodies in a multibody dynamics simulation software (MSC Adams/view, MSC Software, USA). Medial collateral and lateral collateral ligaments were segmented based on MRI-scans and are modelled as finite elements using the HGO model in Abaqus (Simulia, USA). All specimens were submitted varus/valgus loading (0-10Nm) while being rigidly fixed on a testing bench to prevent knee flexion. In subsequent computer simulations of the experimental testing, rigid bodies kinematics and the associated soft-tissue force response were computed at each time step. Ligament properties were optimised using a gradient descent approach by minimising the error between the experimental and simulation-based kinematic response to the applied varus/valgus loads. For comparison, a second model was defined wherein collateral ligaments were modelled as nonlinear no-compression spring elements using the Blankevoort formulation. Models with subject-specific, experimentally calibrated HGO representations of the collateral ligaments demonstrated smaller root mean square errors in terms of kinematics (0.7900° +/− 0.4081°) than models integrating a Blankevoort representation (1.4704° +/− 0.8007°). A novel computational workflow integrating subject-specific, experimentally calibrated HGO predicted post-TKA frontal-plane knee joint laxity with clinically applicable accuracy. Generally, errors in terms of tibial rotation were higher and might be further reduced by increasing the interaction nodes between the rigid body model and the finite element software. Future work should investigate the accuracy of resulting models for simulating unseen activities of daily living


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 58 - 58
11 Apr 2023
Jansen M Salzlechner C Barnes E DiFranco M Custers R Watt F Vincent T Lafeber F Mastbergen S
Full Access

Knee joint distraction (KJD) has been associated with clinical and structural improvement and synovial fluid (SF) marker changes. However, structural changes have not yet been shown satisfactorily in regular care, since radiographic acquisition was not fully standardized. AI-based modules have shown great potential to reduce reading time, increase inter-reader agreement and therefore function as a tool for treatment outcome assessment. The objective was to analyse structural changes after KJD in patients using this AI-based measurement method, and relate these changes to clinical outcome and SF markers. 20 knee OA patients (<65 years old) were included in this study. KJD treatment was performed using an external fixation device, providing 5 mm distraction for 6 weeks. SF was aspirated before, during and immediately after treatment. Weight-bearing antero-posterior knee radiographs and WOMAC questionnaires were collected before and ~one year after treatment. Radiographs were analysed with the Knee Osteoarthritis Labelling Assistant (KOALA, IB Lab GmbH, Vienna, Austria), and 10 pre-defined biomarker levels in SF were measured by immunoassay. Radiographic one-year changes were analysed and linear regression was used to calculate associations between changes in standardized joint space width (JSW) and WOMAC, and changes in JSW and SF markers. After treatment, radiographs showed an improvement in Kellgren-Lawrence grade in 7 of 16 patients that could be evaluated; 3 showed a worsening. Joint space narrowing scores and continuous JSW measures improved especially medially. A greater improvement in JSW was significantly associated with a greater improvement in WOMAC pain (β=0.64;p=0.020). A greater increase in MCP1 (β=0.67;p=0.033) and lower increase in TGFβ1 (β=-0.787;p=0.007) were associated with JSW improvement. Despite the small number of patients, also in regular care KJD treatment shows joint repair as measured automatically on radiographs, significantly associated with certain SF marker change and even with clinical outcome


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 149 - 149
4 Apr 2023
Killen B Willems M Hoang H Verschueren S Jonkers I
Full Access

The aim of this research was to determine biomechanical markers which differentiate medial knee osteoarthritis (OA) patients who do and do not show structural progression over a 2-year period. A cohort of 36 subjects was selected from a longitudinal study (Meireles et al 2017) using Kellgren-Lawrence (KL) scores at baseline and 2-year follow-up. The cohort consisted of 10 healthy controls (HC) (KL=0 at both time points), 15 medial knee OA non-progressors (NPKOA) (KL≥1 at baseline and no change over 2 years), and 11 medial knee OA progressors (PKOA) (KL≥1 at baseline and increase of ≥1 over 2 years). 3D integrated motion capture data from three walking trials were processed through a musculoskeletal modelling framework (Smith et al 2016) to estimate knee joint loading parameters (i.e., magnitude of mean contact pressure, and centre of pressure (COP)). Parameters at first and second peak were extracted and compared between groups using Kruskal-Wallis and Mann-Whitney tests. Higher magnitudes were observed in PKOA vs NPKOA, and PKOA vs HC groups at both time points. Additionally, a posterior (1st and 2nd peak), and lateral (2nd peak) shift in medial compartment COP was shown between PKOA and NPKOA, and PKOA and HC subjects. Interestingly, in the studied parameters, no differences were observed between NPKOA and HC groups. Significantly higher magnitude, and a more posterior and lateral COP was observed between PKOA and NPKOA patients. These differences, combined with an absence of difference between NPKOA and HC suggest structural OA progression is driven by a combination of altered loading magnitude and location. These results may serve as guidelines for targeted gait retraining rehabilitation to slow or stop knee OA progression whereby shifting COP anterior and medial and reducing magnitude by ~22% may shift patients from a PKOA to a NPKOA trajectory


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 61 - 61
1 Jul 2022
Wang D Willinger L Athwal K Williams A Amis A
Full Access

Abstract. Background. Little scientific evidence is available regarding the effect of knee joint line obliquity (JLO). Methods. 10 fresh-frozen human cadaveric knees were axially loaded to 1500 N in a materials testing machine with the joint line tilted 0, 4, 8, and 12 degrees varus and valgus, at 0, and 20 degrees of knee flexion. The mechanical compression axis was aligned to the centre of the tibial plateau. Contact pressures / areas were recorded by sensors inserted between the tibia and femur below the menisci. Changes in relative femoral and tibial position in the coronal plane were obtained by an optical tracking system. Results. medial and lateral JLO caused significant tibiofemoral subluxation and pressure distribution changes. Medial (varus) JLO caused the femur to sublux medially down the coronal slope of the tibial plateau, and vice versa for lateral (valgus) downslopes (P=0.01). Areas of peak pressure moved 12 mm and 8 mm across the medial and lateral condyles, onto the ‘downhill’ meniscus and the ‘uphill’ tibial spine. Changes in JLO had only small effects on maximum contact pressures. Conclusion. A change of JLO during load bearing caused significant mediolateral tibiofemoral subluxation. The femur slid down the slope of the tibial plateau to abut the tibial eminence and also to rest on the downhill meniscus. Clinical Relevance. These results provide important information for understanding the consequences of creating coronal JLO and for clinical practice in terms of osteotomy planning regarding the effect on JLO


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 42 - 42
1 Feb 2020
Innocenti B Bori E Paszicsnyek T
Full Access

INTRODUCTION. Applying the proper amount of tension to knees collateral ligaments during surgery is a prerequisite to achieve optimal performance after TKA. It must be taken into account that lower values of ligament tension could lead to an instable joint while higher values could induce over-tensioning thus leading to problems at later follow-up: a “functional stability” must then be defined and achieved to guarantee the best results. In this study, an experimental cadaveric activity was performed to measure the minimum tension required to achieve functional stability in the knee joint. METHODS. Ten cadaveric knee specimens were investigated; each femur and tibia was fixed with polyurethane foam in specific designed 3D-printed fixtures and clamped to a loading frame. A constant displacement rate of 0.05 mm/s was applied to the femoral clamp in order to achieve joint stability and the relative force was measured by the machine: the lowest force guaranteeing joint stability was then determined to be the one corresponding to the slope change in the force/displacement curve, representing the activation of the elastic region of both collateral ligaments. The force span between the slack region and the found point was considered to be the tension required to reach the functional stability of the joint. This methodology was applied on intact knee, after ACL-resection and after further PCL-resection in order to simulate the knee behavior in CR and PS implants. The test was performed at 0, 30, 60 and 90° of flexion using a specifically designed device. Each configuration was analyzed three times for the sake of repeatability. RESULTS. Results demonstrated that an overall tension of 40–50N is sufficient to reach stability in native knee with intact cruciate ligaments. Similar values appear to be sufficient in an ACL-resected knee, while higher tension is required (up to 60N) for stability after ACL and PCL resection. Moreover, the tension required for stabilization was slightly higher at 60° of flexion compared to the one required at the other angles, reflecting thus the mid-flection instability behavior. DISCUSSION AND CONCLUSIONS. The results are in agreement to other experimental studies. 1,2. and show that the tensions necessary to stabilize a knee joint in different ligament conditions are way lower than the ones usually applied via tensioners nowadays. To reach functional stability, surgeons should consider such results intraoperatively to avoid laxity, mid-flexion instability or ligament over-tension


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 4 - 4
2 Jan 2024
Han S Yoo Y Choi H Lee K Korhonen R Esrafilian A
Full Access

It is known that the gait dynamics of elderly substantially differs from that of young people. However, it has not been well studied how this age-related gait dynamics affects the knee biomechanics, e.g., cartilage mechanical response. In this study, we investigated how aging affects knee biomechanics in a female population using subject-specific computational models.

Two female subjects (ages of 23 and 69) with no musculoskeletal disorders were recruited. Korea National Institute for Bioethics Policy Review Board approved the study. Participants walked at a self-selected speed (SWS), 110% of SWS, and 120% of SWS on 10 m flat ground. Three-dimensional marker trajectories and ground reaction forces (Motion Analysis, USA), and lower limbs’ muscle activities were measured (EMG, Noraxon USA). Knee cartilage and menisci geometries were obtained from subjects’ magnetic resonance images (3T, GE Health Care). An EMG-assisted musculoskeletal finite element modeling workflow was used to estimate knee cartilage tissue mechanics in walking trials. Knee cartilage and menisci were modeled using a transversely isotropic poroviscoelastic material model.

Walking speed in SWS, 110%, and 120% of SWS were 1.38 m/s, 1.51 m/s, and 1.65 m/s for the young, and 1.21 m/s, 1.34 m/s and 1.46 m/s for the elderly, respectively. The maximum tensile stress in the elderly tibial cartilage was ~25%, ~33%, and ~32% lower than the young at SWS, 110%, and 120% of SWS, respectively. These preliminary results suggest that the cartilage in the elderly may not have enough stimulation even at 20% increases in walking speed, which may be one reason for tissue degeneration. To enhance these findings, further study with more subjects and different genders will investigate how age-related gait dynamics affects knee biomechanics.

Acknowledgments: Australian NHMRC Ideas Grant (APP2001734), KITECH (JE220006)


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 122 - 122
1 Mar 2021
Teunissen M Popov-Celeketic J Coeleveld K Meij BP Lafeber F Tryfonidou MA Mastbergen SC
Full Access

Knee joint distraction (KJD) is a joint-preserving treatment strategy for severe osteoarthritis (OA) that provides long-term clinical and structural improvement. Data from both human trials and animal models indicate clear cartilage regeneration from 6 months and onwards post-KJD. However, recent work showed that during distraction, the balance between catabolic and anabolic indicators is directed towards catabolism, as indicated by collagen type 2 markers, proteoglycan (PG) turnover and a catabolic transcription profile [unpublished data]. The focus of this study was to investigate the cartilage directly and 10 weeks after joint distraction in order to elucidate the shift from a catabolic to an anabolic cartilage state. Knee OA was induced bilaterally in 8 dogs according to the groove model. After 10 weeks of OA induction, all 8 animals received right knee joint distraction, employing the left knee as an OA control. After 8 weeks of distraction, 4 dogs were euthanized and after 10 weeks of follow-up the 4 other dogs. Macroscopic cartilage degeneration and synovial tissue inflammation was assessed using the OARSI canine scoring system. PG content was determined spectrometrically using Alcian Blue dye solution and the synthesis of newly formed PGs was determined using . 35. SO. 4. 2-. as a tracer, as was described before. Directly after KJD, macroscopic cartilage damage of the right tibial plateau was higher compared to the left OA control (OARSI score: 1.7±0.2 vs 0.6±0.3; p < 0.001). 10 weeks post-KJD this difference persisted (OARSI score: 1.4± 0.6 vs 0.6±0.3; p = 0.05). Directly after KJD, there was no difference in synovial inflammation between KJD and OA control (OARSI score: 1.4±0.5). At 10 weeks synovial inflammation increased significantly in the distracted knee (OARSI score: 2.1±0.3 vs 1.4±0.5; p < 0.05). Biochemical analysis of the tibia cartilage directly after KJD revealed a lower PG content (20.1±10.3 mg/g vs 23.7±11.7 mg/g). At 10 weeks post-KJD this difference in PG content was less (24.8±6.8 mg/g vs 25.4±7.8 mg/g). The PG synthesis rate directly after KJD appeared significantly lower vs. OA (1.4±0.6 nmol/h.g vs 5.9±4.4 nmol/h.g; p < 0.001)). However, 10 weeks post-KJD this difference was not detected (3.7±1.2 nmol/h.g vs 2.9±0.8 nmol/h.g), and the synthesis rate in the distracted knee was increased compared to directly after distraction (p < 0.01). Further in-depth investigation of the material is ongoing; these first results suggest that the shift from a catabolic to an anabolic state occurs within the first weeks after joint distraction, mostly reflected in the biochemical changes. As such, the post-distraction period seems to be essential in identifying key-players that support intrinsic cartilage repair


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 441 - 441
1 Dec 2013
Murase K Tsutsumi S Takai S Yoshino N
Full Access

The contact condition in the human knee joint must play important roles especially in dynamic loading situations where the loads transfer in the knee. In this study, the impact stress propagations through the inside of the knee joint were simulated using the three-dimensional finite element analysis (FEA). And the differences in the stress distribution were investigated between the intact knee and the total replacement condition. The finite element (FE) models of an intact human knee joint and a total replaced knee joint were constructed with high shape fidelity. The intact model included the cortical bone, cancellous bone, articular cartilage, bone marrow, and meniscus. And the total replacement knee FE model, which is consisted of the artificial femoral and tibial components were also prepared to compare the impact propagations with the intact model (Figure 1). Impact load were applied to the proximal femur of the FE models under the same conditions as those of the weight-drop experiments with the knee joint specimens. The FEA results showed that the impact stress propagated to the tibia through the knee joint for several milliseconds. The values and the time dependent change of the compressive strain on the cortical surface had good agreement with the experimental results. The compressive stress mainly propageted at the medial side, with 1.0 MPa at 1.2 milliseconds. Especially, the impact stress propagated not only in the cortical surface area which has hard material property but also in the soft cancellous bone region inside the knee joint. The mass density of the cancellous bone has similar to that of the cortical bone, and thus the role of the load bearing in the cancellous area must be much increasing under the impact condition. In the total replacement model, concentration of the impact compressive stress was observed with 2.8 MPa at the tibial region, while not under the normal intact conditions (Figure 2). Since the total replacement model is formed of different materials and the impact propagations were inhibited by the interfacial condition, such as sliding or debonding, it is considered that the contact condition between such materials have a great effect on the stress propagation


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 4 - 4
1 Dec 2021
J⊘rgensen AR Hanberg P Bue M Thomassen MB J⊘rgensen N Stilling M
Full Access

Aim. This study evaluated target tissue concentrations of double dose cefuroxime administered intravenously as either one 15 min infusion of 3,000 mg (Group 1) or two single 15 min infusions of 1,500 mg administered 4 h apart (Group 2). Method. Sixteen pigs were randomised into two groups of eight. Cortical and cancellous bone, synovial fluid of the knee joint and subcutaneous adipose tissue concentrations were measured based on sampling via microdialysis. Plasma samples were collected as a reference. Comparison of the groups was based on time with concentrations above relevant minimal inhibitory concentrations (fT>MIC) of 4 μg/mL. Results. The mean time fT>MIC (4 μg/mL) across compartments was longer for Group 2 (280–394 min) than for Group 1 (207–253 min) (p<0.01). Cortical bone showed a tendency towards longer fT>MIC (4 μg/mL) in Group 2 (280 min) than in Group 1 (207 min) (p=0.053). Within 50 min after administration, the mean concentration of 4 μg/mL was reached in all compartments for both groups. The mean concentrations decreased below 4 μg/mL after approximately 4 h (Group 1) and 3 h (Group 2) from initiation of administration (time zero). Conclusions. During an 8 h interval, double-dose cefuroxime administered as 2 × 1,500 mg with a 4 h interval provides longer time above MIC breakpoint for Staphylococcus aureus (4 μg/mL) than a single bolus of 3,000 mg cefuroxime. To maintain sufficient tissue concentrations during longer surgeries, re-administration of cefuroxime (1,500 mg) should be considered 3 h after the first administration


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 7 - 7
1 Dec 2021
Frank BJH Simon S Aichmair A Dominkus M Schwarz GM Hofstaetter JG
Full Access

Aim. Little is known about microbiological spectrum and resistance patterns as well as the clinical outcome in patients who undergo a repeat first stage procedure as part of a 2-stage revision arthroplasty for the treatment of periprosthetic hip and knee joint infections. Methods. Between 2011 and 2019, a total of 327 2-stage revision arthroplasties were performed on 312 patients with PJI of the knee and hip at our institution. We performed a retrospective analysis of all patients, who underwent a repeat first stage procedure regarding re-revision rate, host factors, culture negative and positive stages, monomicrobial and polymicrobial infections as well as microbiological spectrum and antimicrobial resistance patterns. Results. Overall, 52/312 (16.7%) patients (27 knee/25 hip) underwent a repeat first stage procedure. There were 35/52 (67.3%) culture positive first, 17/52 (32.7%) culture positive repeat first and 12/52 (23.1%) culture positive second stage procedures. In 13/52 (25%) patients a re-revision surgery was necessary at a median follow-up of 46.8 months (range, 12.2 to 93.3 months). High re-revision rates (10/12 [83.3%]) were found in patients with culture positive second stage and low re-revision rates (3/40 [7.5%]; p<0.01) were found in patients with culture negative second stage. The microbiological spectrum changed in 9/11 (81.8%) patients between culture positive first and repeat first stage, in 3/4 (75%) patients between culture positive repeat first and second stage and in 5/6 (83.3%) between culture positive second stage and subsequent re-revision surgery. Moreover, the antimicrobial resistance pattern changed in 6/9 (66.7%) of persistent microorganisms. Conclusion. Microbiological results during first, repeat first and second stage procedures significantly impacted the re-revision rates and changes in microbiological spectrum and resistance patterns between stages are common. However, if eradication of the microorganism at second stage can be accomplished, low re-revision rates can be achieved, even in patients who require a repeat first stage procedure


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 66 - 66
1 May 2016
Murase K Tsutsumi S Takai S
Full Access

The Total Knee Replacement (TKR) has been used as the effective treatment for osteoarthritis of the knee. The load of the knee joint is generally applied at the heel strike as the impact loading. In the elderly who had muscle weakness or weakening eyesight, it can be anticipated that more excessive loads are often added to the knees when they stumble or trip over. And the varus / valgus alignments of the femur and tibia differs among patients. However, most finite element analyses considering the effect of the alignments have rarely been performed. In this study, the mounting angle of the tibia component in the TKR knee was changed, and the effect of the change on the load transfer was assess using finite element analyses. Based on the CT images, the three-dimensional finite element models of the natural knee joint and TKR knee joint were created [Fig. 1]. Each model was constructed from hexahedoral elements with the isotropic material. The numbers of nodes and elements were 10,666 and 8,677 respectively. Under normal alignment, 5 degrees of varus, and 5 degrees of valgus knee, the static analyses at an applied load of 1000N and impact analyses at an applied load of 50 kg were performed. LS-DYNA ver760 software was used for the analyses. The finite element analyses results showed that under the static loading, no stress shielding was observed in the tibial cancellous bone of the intact knee or TKR knee, and the maximum compressive stress was 1.5 MPa. While under the impact loading, the compressive stress generated inside of the cancellous bone was three times higher in the TKR knee joint than that in the intact knee, and the load transfer time was reduced. This result reveals that the cancellous bone have load bearing function especially in the impact condition. When the impact load was applied to the varus and valgus TKR knee, the stress shielding was observed in the tibial cancellous bone, especially in the varus condition. In a case where the tibia component was mounted by tilting it at −5 to 5 degrees depending on the varus/valgus of the knee, the stress shielding was alleviated; the distribution of load was almost the same as that of the TKR knee joint model under the normal alignment [Fig.2]. The effect of a slight difference in the alignment on the stress distribution is expected to be a contributor to determine artificial knee joint shape, loading condition, and other design factors in developing revision arthroplasty or custom-made implant


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 78 - 78
4 Apr 2023
Voropai V Nieher M Kratsch A Kirchner W Giggel B Lohmann C Bertrand J Weißmantel S Döring J
Full Access

Total knee arthroplasty is one of the most common surgeries. About 92% of all implanted knee endorposthesis in 2020 were manufactured from uncoated CoCrMo articulating on ultra-high-molecular-weight polyethylene. All articluations generate wear particles and subsequent emission of metal ions due to the mechanical loading. These wear particles cause diverse negative reactions in the surrounding tissues and can lead to implant loosening. Coating technologies might offer the possibility to reduce this wear. Therefore, we investigated the applicability of tetrahedral amorphous carbon (ta-C) coating on CoCrMo alloy.

Polished specimens made of CoCrMo wrought alloy according to ISO 5832-12 were coated with ta-C coatings with different layer structure using pulsed laser deposition (PLD). This process allows the deposition of ta-C coatings with low internal stress using an additional relaxation laser. Surface quality and mechanical properties of the coating were characterised using optical surface measurements (NanoFocus μsurf expert, NanoFocus AG) and a nanoindentation tester NHT3 (Anton Paar GmbH). Scratch tests were performed on Micro Scratch Tester MST3 (Anton Paar TriTec SA) to define the coating adhesion. Pin-on-plate tribological tests, with a polyethylene ball sliding on the ta-C-coated plate under a defined load according to ISO 14243-1 were performed using a linear tribometer (Anton Paar GmbH) to evaluate the tribological and wear properties.

The ta-C coatings showed a mean roughness Ra of 5-20 nm and a hardness up to 60 GPa (n=3). The adhesion of the ta-C coatings (n=3) was comparable to the commercial coatings like TiN and TiNbN. The pin-on-plate tests showed an improvement of tribological properties in comparison with the polished uncoated CoCrMo specimens (n=3).

The ta-C coatings applied by DLP technology show increased hardness compared to the base material and sufficient adhesion. Further research will be needed to investigate the optimal coating strategy for implant coating.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 76 - 76
22 Nov 2024
Gardete-Hartmann S Sebastian S Berdalli S Simon S Hofstaetter J
Full Access

Aim

Unexpected negative-cultures (UNC) are a common diagnostic problem in periprosthetic joint infection (PJI) of the hip and knee when using culture-based methods. A novel molecular approach (MC)1 based on the identification of the vast majority of bacterial species in a single assay using species-specific bacterial interspacing region length polymorphisms and phylum-specific 16S rDNA sequence polymorphisms has demonstrated clinical utility in PJI diagnostics (1). In addition, MC provides an estimate of the leukocyte concentration in the specimen analysed. The aim of this retrospective, blinded study was to evaluate the performance of MC in identifying the microbiological content and determining the leukocyte count in synovial fluid (SF) collected from hip and knee revision arthroplasty cases with UNC. It was also assessed whether antibiotic treatment would have been changed if the result from MC had been known.

Method

A total of 89 SF samples from 70 patients (43 female; 27 male) who underwent revision arthroplasty (14 hip; 75 knee) were included. Using European and Bone Joint Infection Society (EBJIS) criteria, 82 cases were classified as infected (77 UNC and 5 septic culture-positive controls), five as non-infected (aseptic culture-negative controls), and two as likely infected, but infected by clinical observation. MC was performed and evaluated together with SF parameters. Antibiotic treatment, clinical outcome, patient demographics and surgical details were analysed.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 163 - 163
1 Jul 2002
Barrett DS Taylor M
Full Access

Purpose: Posters of study: To produce a virtual reality model of prosthetic knee joint motion, giving detail regarding contact area and contact pressures during the process of walking. Method: Using serial CT scans and data regarding the material properties of bone, cartilage, ligaments and other soft tissue structures a computational “virtual reality model” of the knee has been constructed. This computational model which is a 3D dynamic representation of a human knee joint, may be programmed to replicate the standard gait pattern of the human knee. This study details the development of this model and its validation against the accepted Stenmore Test Rig for modelling of knee joint movement and knee prosthetic wear. The validation results will be presented,. The model allows the calculation and representation of contact pressures and contact areas in the knee joint as it moves through the gait cycle. This study also shows the effect of uni-condular loading and varus mal-positioning which may occur at surgery and the effect this has on the contact area and contact pressures of a prosthetic knee in ambulation. The resultant gait pattern produced by uni-condular loading and exhibited by the virtual knee closely resembles that seen in In Vivo Kinematic Studies reported by other authors. In conclusion we present this as a valid computational dynamic model of knee prosthetic wear and kinematics which represents an enormous advantage over standard mechanical testing and presents possibilities for rapid analysis in new knee joint designs and the effect of abnormalities of gait and wear


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 4 - 4
1 Jan 2022
Reddy G Rajput V Singh S Iqbal S Anand S
Full Access

Abstract

Background

Fracture dislocation of the knee involves disruption of two or more knee ligaments with associated tibial plateau fracture. If these injuries are not evaluated swiftly, can result in a limb-threatening injury. The aim of this study is to look at the clinical outcomes of a single surgeon case series at a major trauma centre.

Methods

Prospectively collected data was analysed for a 5-year period. Primary outcome measures used were International Knee Documented Committee(IKDC) score and Knee Injury & Osteoarthritis Outcome Score(KOOS). The secondary outcome measures include Tegner activity scale, knee range of movements & complications.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 198 - 198
1 Mar 2013
Hirokawa S Fukunaga M Mawatari M
Full Access

The objective of this study is to investigate the effect of the tensile force ratio between the two extensor muscles for the hip joint on the forces acting on the knee joint. We have created a mathematical model of lower limb and have performed some simulations to introduce the forces acting on the knee joint for various daily activities. With only one exception, our results for knee joint forces were in good or close agreement involving all range of knee flexion either with the in vivo data or other literature data. The exception was that, at high knee flexion angle (knee bend), the tangential components of knee joint force became pretty larger than those from the in vivo data, while the normal components did not differ much with each other though as shown in Fig. 1. We considered that the above mentioned discrepancy was attributed to the fact that in order to solve an indeterminate problem, we had assumed the hamstrings and the gluteus maximus work together with the same force with each other, thereby introducing the hamstrings force too great. Then we expected that the above discrepancy could be eliminated if we change the tensile force ratio between the hamstrings and the gluteus maximus basing upon a certain biomechanical criterion, for example the biological cross-sectional areas. Thus we modified our model so that we could introduce the knee joint forces as a function of the tensile force ratio. Simulation was performed for the various tensile ratio values and it was found that the knee joint force was sensitively affected by the tensile ratio and the above mentioned discrepancy between the simulation results and the in vivo data could be eliminated if the ratio value was appropriately chosen. Figure 2 shows the situation; Variations of Fn and Ft as a function of knee angle q for the various tensile force ratio r between the hamstrings and the gluteus maximus. Where, r=1.56 was determined from the biological cross-sectional areas of the hamstrings and the gluteus maximus and r=4.5 was determined so that the simulation results best fit to the in vivo data. It has been criticized that there exist large variations of knee joint forces obtained from model analyses. And the reasons for this have been attributed to for example such facts that the model is 2D and the parameter values are incorrect. Yet, another important issue may be to find out the way how to determine the value of the synergetic muscles' force ratio with reflecting a biological rationality


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 162 - 162
1 Sep 2012
Scheys L Wong P Callewaert B Leffler J Franz A Vandenneucker H Labey L Leardini A Desloovere K
Full Access

INTRODUCTION. In patients with neural disorders such as cerebral palsy, three-dimensional marker-based motion analysis has evolved to become a well standardized procedure with a large impact on the clinical decision-making process. On the other hand, in knee arthroplasty research, motion analysis has been little used as a standard tool for objective evaluation of knee joint function. Furthermore, in the available literature, applied methodologies are diverse, resulting in inconsistent findings [1]. Therefore we developed and evaluated a new motion analysis framework to enable standardized quantitative assessment of knee joint function. MATERIALS AND METHODS. The proposed framework integrates a custom-defined motion analysis protocol with associated reference database and a standardized post-processing step including statistical analysis. Kinematics are collected using a custom-made marker set defined by merging two existing protocols and combine them with a knee alignment device. Following a standing trial, a star-arc hip motion pattern and a set of knee flexion/extension cycles allowing functional, subject-specific calibration of the underlying kinematic model, marker trajectories are acquired for three trials of a set of twelve motor tasks: walking, walking with crossover turn, walking with sidestep turn, stair ascent, stair descent, stair descent with crossover turn, stair descent with sidestep turn, trunk rotations, chair rise, mild squat, deep squat and lunge. This specific set of motor tasks was selected to cover as much as possible common daily life activities. Furthermore, some of these induce greater motion at the knee joint, thus improving the measurement-to-error ratio. Kinetics are acquired by integrating two forceplates in the walkway. Bilateral muscle activity of 8 major muscles is monitored with a 16 channel wireless electromyography (EMG) system. Finally, custom-built software with an associated graphical user interface was created for automated and flexible analysis of gait lab data, including repeatability analysis, analysis of specific kinematic, kinetic and spatiotemporal parameters and statistical comparisons. RESULTS. Following ethical approval and informed consent, the proposed framework was successfully applied in a control group of 80 normal subjects within a wide age-range (age: 54.5Y±19.1; BMI: 25.5±4.0; 40M/40F; 60 Caucasian, 20 Asian) thus constructing the reference database for control. Moreover, the same framework was applied successfully in a randomly selected group of 10 patients with a bi-compartmental knee replacement (BKR) (age: 67.3Y±5.3; BMI: 29.7±3.1; time post-op: 1.65Y±0.4; 2M/8F Caucasian). Comparison between these patients and age-matched controls demonstrates that, for a large range of motor tasks, knee joint kinematics after BKR are as much consistent with the healthy controls (coefficient of multiple correlation (CMC) =0.49) as the consistency within a group of controls or BKR-subjects individually (CMC=0.52). Nevertheless, also significant differences (p<0.0167) were identified which are indicative for retention of pre-operative motion patterns and/or remaining compensations. CONCLUSION. The proposed framework allows in-vivo evaluation of knee joint performance in a standardized, objective and non-invasive way. It is applicable in both healthy subjects and knee replacement patients and is shown to be sufficiently sensitive to detect even relatively small differences between the two populations