Advertisement for orthosearch.org.uk
Results 1 - 20 of 102
Results per page:
Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 220 - 220
1 Nov 2002
Kyle R
Full Access

A new and very unstable intertrochanteric fracture complex is described. The intertrochanteric fracture with extension into the femoral neck is rare but results in an extremely high failure rate because of its instability. A ten-year retrospectic analysis of patients (246) with intertrochanteric fractures treated with a sliding compression hip screw at Hennepin County Medical center was performed. Of these 246 fractures, 20 were classified as fractures with a major intertrochanteric component with extension into the femoral neck. These fractures were similar to intertrochanteric fractures type I-IV described by Kyle and Gustilo in demographics, osteoporosis, and surgical treatment, but this new fracture fracture now described as Type V had a statistically higher rate of mechanical complications 0.0001, reoperation 0.0002, and failure of fixation 0.0001. The overall failure rate was 50%. The majority of these fractures were the result of complete collapse of the hip screw. We feel this higher complication and reoperation rate is secondary to inherent instability in the intertrochanteric fracture which extends into the femoral neck. This instability leads to cmplete collapse of a sliding hip screw result ing in a rigid device that leads to failure of fixation. This fracture complex also has a higher rate of nonunion and avascular necrosis. Although rare, this fracture must be recognized in the fracture classification of intertrochanteric fractures because of its poor prognosis. Other forms of treatment than a sliding hip screw may be considered with this fracture complex because of its high failure rate with standard treatment


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 25 - 25
1 Nov 2018
Kawamura T Minehara H Matsuura T Tazawa R Takaso M
Full Access

The reduction for unstable femoral intertrochanteric fracture should be extramedullary, which means that the proximal fragment protrudes for the distal fragment. However, only few articles have compared extramedullary and intramedullary reductions in a biomechanical study. Thus, we created unstable femoral intertrochanteric fracture models using imitational bone (extramedullary and intramedullary groups, each with 12 cases) and evaluated their biomechanical stabilities. The fracture type was 31-A2 according to the AO-OTA Classification of Fractures and Dislocations and greatly lacked bone on the posterior side. We performed compression examination and evaluated stiffness. The implant used for fixation was TFNA (DePuy Synthes). We applied axial compression with 20 adduction in the standing position. Statistical analysis was performed using the Mann-Whitney U test. No significant difference in initial loading force was found between the two groups. However, the axial stiffness of the extramedullary bone showed a significant increase (p < 0.05) in high loading force (800–1000 N). This means that the stability of the extramedullary reduction was superior to that of the intramedullary reduction in terms of high loading force in the standing position. We suggest that antero-medial bony buttress is important for unstable femoral intertrochanteric fractures. These data indicate that extramedullary reduction and fixation for unstable femoral intertrochanteric fractures increase stability


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 600 - 600
1 Dec 2013
Yoshioka S Kanematsu Y Yamamoto N Naohito H Takahashi M Tatsuhiko H
Full Access

We report an intertrochanteric fracture in a patient who had undergone hip arthrodesis 30 years previously. A 53-year-old man was injured in a head-on car crash and was referred to our hospital for treatment. Plain radiographs showed an intertrochanteric fracture of the right proximal femur and deformity of the right hip joint. He had undergone hip arthrodesis surgery 30 years previously at another hospital. Computed tomography scan showed marked atrophy of the gluteus and iliopsoas muscles. He preferred undergoing total hip arthroplasty (THA) to internal fixation. THA was performed using the anterolateral approach with the patient in the supine position as he had undergone hip arthrodesis through the Smith–Petersen approach, and we were concerned about damaging the gluteus muscle and dislocation if we took the posterolateral approach. The femoral head was removed using curved chisels under fluoroscopy. A cementless THA (J Taper stem, Aquala polyethylene liner; Kyocera Medical Corporation, Osaka, Japan) was inserted and fixed appropriately. Full weight-bearing using a walking frame was allowed 2 weeks after the surgery. Six months after the operation, he was able to walk independently and had good range of movement of the hip joint but continued to have weakness in the abductor muscles. Very few cases of proximal femur fracture in a previously arthrodesed hip have been reported. Manzotti et al. reported a similar case but they performed open reduction and internal fixation. No previous reports in the literature describe THA for intertrochanteric fracture in an arthrodesed hip. The conversion of an arthrodesed hip to THA is technically challenging. It has a high risk of complications such as nerve injuries and hip instability. We were able to treat the patient successfully, but surgeons should carefully decide the treatment method depending on the case


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 289 - 289
1 Mar 2013
Ogawa K
Full Access

Introduction. Fracture of the proximal femur frequently occur in children with osteogenesis imperfecta(O.I.) or fibrous dysplasia and may lead to progressive coxa vara and a “shepherds crook” deformity. In adults, these changes introduce difficulties that are not ordinarily encountered with routine osteosynthesis. There is minimal literature on this topic and the cases reported are few in number. Objective. The purpose of this case report was to describe a intertrochanteric fracture in a elderly woman with O.I. successfully treated by 115 degrees hip osteotomy plate and cannulated screws. Methods. We present a case of a 82-year-old female who was injured by falling. She had O.I. type â�£ A according to Sillence. Radiographs showed a intertrochanteric fracture of the femur with severe deformity. The femoral shaft had 25 degrees angular deformity and moderate rotation at the proximal. The angle between femoral neck and shaft was 105 degrees (severe coxa vara) and the proximal femur had a “shepherds crook” deformity (See Figure 1). She had presented 70 years previously ipsilateral fractures of the femur which had healed. These mal-united fracture involved anatomical changes such as medicalization of the femoral canal and intramedullary remodeling and sclerosis (See Figure 2). Recognizing the anatomical changes before and during surgery, standard dynamic hip screw or AO angled blade plate could not fit the femur and not provide stability. Using 115 degrees hip osteotomy plate and cannulated screws, osteosynthesis was performed (See Figure 3). Results. Twelve months postoperatively, the fracture united without complications and the patient felt comfortable and satisfied with gait. Conclusion. An unusual case was presented in which a 82-year-old woman was successfully treated with 115 degrees hip osteotomy plate and cannulated screws for a intertrochanteric fracture of the femur with osteogenesis imperfecta. Standard plate osteosynthesis was unlikely to provide sufficient stable fixation in this case


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 52 - 52
1 Oct 2018
Parry J Langford J Koval K Haidukewych G
Full Access

Introduction. The vast majority of intertrochanteric fractures treated with cephalomedullary nails (CMN) will heal. Occasionally even though bony union occurs excessive lag screw sliding can cause persistent pain and soft tissue irritation and return to surgery for hardware removal. The purpose of this study was to evaluate if fracture stability, lag screw tip-apex distance (TAD), and quality of reduction have any impact excessive lag screw sliding and potential cutout. Methods. As part of our level one trauma center's institutional hip fracture registry, a retrospective analysis identified 199 intertrochanteric fractures fixed with CMN between 2009 and 2015 with follow up to union or a minimum of three months. The mean follow-up was 22 months (3 to 94 months). Mean patient age was 75 years (50 to 97 years) and 72% were women. Postoperative radiographs were used to measure the TAD, quality of reduction, neck-shaft angle (NSA), and lateral lag screw prominence. Follow-up radiographs were reviewed to assess fracture union, translation, and progression of lateral lag screw prominence. Complications and reoperations were recorded. Results. The average lag screw sliding was 5±5 mm. Excessive lag screw sliding (defined as > 10 mm; one standard deviation above the mean) was present in 12% of patients. Lag screw sliding was more common in unstable fracture patterns (21% vs. 5%, p<0.01) and patients with calcar fracture gapping > 4 mm (26% vs. 4%, p<0.01). Lag screw sliding was not associated with age (p=0.9), sex (p=0.4), TAD (p=0.3), implant (p=0.8), distal interlocking screws (p=0.3), or NSA (p=0.2). There were seven (3%) patients with prominent lag screws that required removal. These patients experience more lag screw sliding than those that did not require removal (9 mm vs. 5 mm, p<0.01). The average TAD was 17±5 mm. 15 (7%) of patients had TAD of 25 mm or more. There were 2 cutouts (1%). The average TAD was larger in the cutout group (26 vs. 17 mm, p<0.01). Conclusion. In this series, the incidence of cutout was low and associated with a larger tip-apex distance. Excessive lag screw sliding was associated with unstable fracture patterns, calcar fracture gapping, and more reoperations for symptomatic hardware. Careful attention to calcar fracture reduction may minimize excessive lag screw sliding


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 475 - 475
1 Dec 2013
Park SE Yeo DH
Full Access

The first case was that of an 89-year-old woman with advanced dementia. After falling onto the left hip, she was admitted to the emergency room. Standard x-rays revealed an unstable intertrochanteric fracture. Closed reduction and internal fixation was performed using the long PFNA with a 105-mm helical blade, the second patient treated with this implant in our series. The operation was performed by an attending surgeon who was experienced with treatment of trochanteric fractures with intramedullary devices. Six weeks later the patient presented again with severe pain after she had fallen onto her left hip for a second time. Follow-up x-rays showed a perforation of the helical blade through the cortex of the femoral head after a shortening of the femoral neck by 2 cm. CCD angle was still 129 degrees, and there were no radiological signs of rotational displacement. The acetabular cartilage appeared intact. At her second operation, a replacement of the blade was performed using a shorter 95-mm implant. Postoperatively the patient was again mobilized under full weight bearing, and at 12 weeks follow-up, we found cut through again, we replaced hip with biopolar hemiarthroplasty


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 105 - 105
1 May 2016
Kim J Park B Cho H
Full Access

Purpose. To observe the follow-up results of standard cemented bipolar hemiarthroplasty with double loop and tension band wiring technique for treatment of unstable intertrochanteric hip fractures in elderly patients with osteoporosis. Materials and Methods. From May 2000 to May 2006, 86 cemented bipolar hemiarthroplasties were performed in elderly patients who had unstable intertrochanteric fractures. The mean age at the time of surgery was 82 years old. The average follow-up period were 5.3 years. We evaluated post-operative results after operation by clinical and radiographic methods. Results. Clinically, the final follow-up of Harrsi hip score was noted 79.2. The mean time needed for full weight bearing following surgery was 4.2 weeks and 82.5% of patients regained their preoperative ambulatory level. All patients achieved union in lesser trochanter fracuture, but great trochanter displacement were observed in 4 cases. There was one case of acetabular erosion. Post-operative superficial infections were found in 2 cases. 1 case with stem subsidence(<5 mm) showed satisfactory results without further subsidence in follow-ups. Conclusion. If we properly apply indications in technique with cemented bipolar hemiarthroplasty in the treatment of unstable intertrochanteric hip fracture in elderly, we will achieve systematic postoperative rehabilitation, pain control and handy nursing which is its one of merits


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 245 - 245
1 Sep 2012
Brin Y Palmanovich E Nyska M Kish B
Full Access

Background. Hip fractures affect annually over 350,000 people in the USA and over 1.6 million worldwide. About 50% of these numbers are intertrochanteric fractures,. The surgeon should be able to minimize the morbidity associated with the fracture by: recognizing the fracture pattern, choosing the appropriate fixation device, performing accurate reductions with ideal implant placement and being conscious of implant costs. In this study we assessed the ability of the orthopaedic surgeons to recognize fractures pattern, and choosing the ideal implant for the recognized fracture. Methods. We assessed 134 orthopaedic surgeons with questionnaires that assessed 14 different intertrochanteric femoral fractures. We evaluated the fractures as stable or unstable. We chose for each fracture the appropriate fixation device: either a Dynamic Hip Screw (for stable fractures) or an Intra Medullary Nail (for unstable ones), taking into consideration fracture's stability and implants’ costs. We compared the answers of the assessed surgeons to ours. Results. 134 orthopaedic surgeons fulfilled our questionnaires. The average agreement among the assessed surgeons and the authors for fractures’ stability distributed as follows: 78.2% agreement for the stable fractures, 86.2% for the unstable fractures. The agreement for the appropriate fixator between both groups (authors and surgeons) distributed as follows: in choosing the dynamic hip screws for the stable fractures 79.6% agreed with our choice. When choosing the Intra Medullary Nail for the unstable fractures 72.4% of the surgeons agreed with our choice. Interestingly, surgeons that their subspecialty is orthopaedic trauma tended to use more the Intra Medullary Nails in the stable fractures compared to the other surgeons. Conclusions. The majority of the assessed surgeons know to recognise inertrochanteric fractures’ stability and to choose the appropriate fixation device. 20% of surgeons did not agree with our choices. Choosing an Intra Medullary Nail for the stable fracture is not a mistake, but the wrong fixation device for the unstable fracture may cause non-union, mal-union or hardware failure, and might complicate patients’ rehabilitation and cure. We believe that a team discussion should take place for each and any case before operation, and whenever there is a doubt about fractures stability, the Iintra Medullary Nail should be chosen


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 164 - 164
1 Sep 2012
Gibson D Keogh C Morris S
Full Access

Introduction. Lag screw cut-out following fixation of unstable intertrochanteric fractures in osteoporotic bone remains an unsolved challenge. A novel new device is the X-Bolt which is an expanding type bolt that may offer superior fixation in osteoporotic bone compared to the standard DHS screw type device. Aims. The aim of this study was to test if there was a difference in cut-out using the X-Bolt implant compared with the standard DHS system. Methods. Specimens of low density surrogate bone (5pcf) were inserted into a simplified biomechanical fracture model and had either an X-Bolt or DHS implant inserted. There were eight samples in each group. The fracture model was tested with an incremental cyclical loading programme in a Material Test System. Displacement, cycle count and force exerted were continuously recorded until cut-out of the implant. Results. All of the specimens failed by varus collapse with superior cut-out and resulted in an automatic stop of the MTS. Specimens with the X-Bolt implant inserted lasted longer on cyclical count and withstood a greater force at cut-out compared with DHS specimens. The mean number of cycles to cutout in the DHS specimens was 4345 and in specimens with the X-Bolt inserted was 6898. The mean force at which cutout occurred in the DHS group was 1.025kN and in specimens with the X-Bolt inserted was 1.275kN. A statistically significant difference was observed with a P-value of 0.005 and a power of 87.2% with respect to cycle count and a P-value of 0.008 and power 84.8% with respect to force exerted at failure when comparing between the two groups. Conclusion. This study shows that the X-Bolt device demonstrated superior cut-out resistance and withstood greater loads compared to the DHS in low density surrogate bone in an unstable fracture model under cyclical axial loading


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 250 - 250
1 May 2006
Jesudason E Jeyem M
Full Access

Introduction Intertrochanteric fractures are common and represent a major source of morbidity and mortality. As with all orthopaedic implants a DHS can fail. One of the most important predictors of failure has been shown to be the Tip-Apex Distance (TAD). An audit was carried to assess the following:. What was our rate of cut out and implant failure?. Where we achieving an acceptable screw position and TAD?. Was there any difference between TAD and grade of surgeon?. Methods An audit of the case notes and x-rays of 54 consecutive patients with hip fractures, treated with DHS, within a twelve-month period were reviewed. Demographic data, grade of surgeon, fracture stability, DHS position, mortality and implant failure were assessed. Findings Our rate of failure was 2 out of 54 patients, 3.7%. Both of the patients that failed had a TAD of greater than 20mm, and none of the patients with a TAD below 20mm required further surgery. There was no statistical correlation between TAD and grade of operating surgeon. Recommendations It is paramount importance to ensure that the basic principles of DHS position are well taught to surgical trainees in order to reduce the risk of failure. Following DHS fixation, patients should be followed up for a minimum of 3 months until evidence of radiographic union is evident. DHS failure rates and screw positions should be constantly audited to ensure that failure rates are minimised


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 426 - 426
1 Nov 2011
Thakur R
Full Access

Failure of internal fixation of intertrochanteric fractures is associated with delayed union or malunion resulting in persistent pain and diminished function. We evaluated 15 elderly patients treated with a tapered, fluted, modular, distally fixing cementless stem. At an average follow up of 2.86 years, mean Harris hip score improved from 35.90 preoperatively to 83.01 (P < 0.01). Fourteen stems had stable bony ingrowth and one stem was loose. Distal fixation with a tapered fluted modular cementless stem allows stable fixation with good functional outcome in a reproducible fashion in this challenging cohort of patients


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 54 - 54
1 Dec 2020
Kacmaz IE Egeli E Basa CD Zhamilov V
Full Access

Proximal femur fractures are common in the elderly population. The aim of this study was to determine the relationship between fracture type and proximal femoral geometric parameters. We retrospectively studied the electronic medical records of 85 elderly patients over 60 years of age who were admitted to the orthopedic department with hip fractures between January 2016 and January 2018 in a training and research hospital in Turkey. Age, fracture site, gender, implant type and proximal femoral geometry parameters (neck shaft angle [NSA], center edge angle [CEA], femoral head diameter [FHD], femoral neck diameter [FND], femoral neck axial length [FNAL], hip axial length [HAL], and femoral shaft diameter [FSD]) were recorded. Patients with femoral neck fractures and femur intertrochanteric fractures were divided into two groups. The relationship between proximal femoral geometric parameters and fracture types was examined. SPSS 25.0 (IBM Corparation, Armonk, New York, United States) program was used to analyze the variables. Independent samples t test was used to compare the fracture types according to NSA, FHD, FND and FSD variables. A statistically significant difference was found in FSD (p=0,002) and age (p=0,019). FSD and age were found to be greater in intertrochanteric fractures than neck fractures. Gender, site, CEA, FNAL, HAL, NSA, FHD and FND parametres were not significantly different. In the literature, it is seen that different results have been reached in different studies. In a study conducted in the Chinese population, a significant difference was found between the two groups in NSA, CEA and FNAL measurements. In a study conducted in the Korean population, a significant difference was found only in NSA measurements. The FSD is generally associated with bone mineral densitometry in the literature and has been shown to be a risk factor for fracture formation. However, a study showing that there is a relationship between FSD and fracture type is not available in the literature. In this study; FSD was found to be higher in intertrochanteric fractures (p = 0.002). However, for the clinical significance of this difference, we think that larger patient series and biomechanical studies are needed


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 74 - 74
4 Apr 2023
Mariscal G Barrés M Barrios C Tintó M Baixauli F
Full Access

To conduct a meta-analysis for intertrochanteric hip fractures comparing in terms of efficacy and safety short versus long intralomedullary nails. A pubmed search of the last 10 years for intertrochanteric fracture 31A1-31A3 according to the AO/OTA classification was performed. Baseline characteristics of each article were obtained, complication measures were analyzed: Peri-implant fracture, reoperations, deep/superficial infection, and mortality. Clinical variables consisted of blood loss (mL), length of stay (days), time of surgery (min) and nº of transfusions. Functional outcomes were also recorded. A meta-analysis was performed with Review Manager 5.4. Twelve studies were included, nine were retrospective. The reoperations rate was lower in the short nail group and the peri-implant fracture rate was lower in the long nail group (OR 0.58, 95% CI 0.38 to 0.88) (OR 1.88, 95% CI 1.04 to 3.43). Surgery time and blood loss was significantly higher in the long nail group (MD −12.44, 95% CI −14.60 to −10.28) (MD −19.36, 95% CI −27.24 to −11.48). There were no differences in functional outcomes. The short intramedullary nail has a higher risk of peri-implant fracture; however, the reoperation rate is lower compared to the long nail. Blood loss and surgery time was higher in the long nail group


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 54 - 54
23 Jun 2023
Shaath MK Yawman J Anderson T Avilucea F Langford J Munro M Haidukewych GJ
Full Access

Intertrochanteric fractures are common, accounting for nearly 30% of all fracture related admissions. Some have suggested that these fractures should be treated in community hospitals so as not to tax the resources of Level One trauma centers. Since many factors predictive of fixation failure are related to technical aspects of the surgery, the purpose of this study was to compare radiographic parameters after fixation comparing trauma fellowship trained surgeons to non-fellowship trained community surgeons to see if these fractures can be treated successfully in either setting. Using our hospital system's trauma database, we identified 100 consecutive patients treated with cephalomedullary nails by traumatologists, and 100 consecutive patients treated by community surgeons. Quality of reduction, neck shaft angle (NSA), tip-to apex distance (TAD) were compared. The mean TAD for the trauma group was 10mm compared to 21mm for the community group (p<0.001). The mean postoperative NSA for the trauma group was 133 degrees compared to 127 degrees for the community group (p<0.001). The mean difference in the NSA of the fractured side compared to the normal hip was 2.5 degrees of valgus in the trauma group compared to 5 degrees of varus for the community group (p<0.001). There were 93 good reductions in the trauma group compared to 19 in the community group (p<0.001). There were no poor reductions in the trauma group and 49 poor reductions in the community group (p<0.001). Fellowship trained traumatologists achieved significantly more accurate reductions and implant placement during cephalomedullary nailing of intertrochanteric hip fractures


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 113 - 113
10 Feb 2023
Burrows K Lock A Smith Z McChesney S
Full Access

Failure of cephalomedullary fixation for proximal femur fractures is an uncommon event associated with significant morbidity to the patient and cost to the healthcare system. This institution changed nailing system from the PFNA (DePuy Synthes) to InterTan (Smith and Nephew) in February 2020. To assess for non-inferiority, a retrospective review was performed on 247 patients treated for unstable proximal femur fractures (AO 31 A2; A3). Patients were identified through manual review of fluoroscopic images. Stable fracture patterns were excluded (AO 31 A1). Pre/post operative imaging, demographic data, operative time and ASA scores assessed. Internal/external imaging and national joint registry data were reviewed for follow up. No significant difference was found in overall failure rate of PFNA vs InterTan (4.84% vs 3.23%; p = 0.748). Overall, short nails were more likely to fail by cut-out than long nails (7.5% vs 1.2%; p = 0.015). Nails which failed by varus cut-out had a higher tip/apex distance (TAD) (26.2mm vs 17.0mm; p < 0.001). Of concern, varus cut-out occurred in two InterTan nails with TAD of <25mm. The PFNA enjoyed a shorter operative time for both the short (59.1 vs 71.8 mins; p = 0.022) and long nails (98.8 vs 114.3 mins; p = 0.016) with no difference in 120-day survival rate. Overall failure rates of the PFNA and InterTan nailing systems were comparable. However, the failure rate of short nails in this study is concerning. Using long nails with a lag screw design for unstable intertrochanteric femoral fractures may reduce failure rates. Cumulative frequency analysis suggests stringent tip-apex distances of less than 21mm may reduce failure rates in lag-screw design cephulomedullary nails. This dataset suggests that unstable intertrochanteric fractures may be more reliably managed with a long cephalomedullary device


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 12 - 12
1 Oct 2022
Fes AF Leal AC Alier A Pardos SL Redó MLS Verdié LP Diaz SM Pérez-Prieto D
Full Access

Aim. The most frequent mechanical failure in the osteosynthesis of intertrochanteric fractures is the cut-out. Fracture pattern, reduction quality, tip-apex distance or the position of the cervico-cephalic screw are some of the factors that have been associated with higher cut-out rates. To date, it has not been established whether underlying bacterial colonization or concomitant infection may be the cause of osteosynthesis failure in proximal femur fractures (PFF). The primary objective of this study is to assess the incidence of infection in patients with cut-out after PFF osteosynthesis. Method. Retrospective cohort study on patients with cut-out after PFF osteosynthesis with endomedullary nail, from January 2007 to December 2020. Demographic data of patients (such as sex, age, ASA), fracture characteristics (pattern, laterality, causal mechanism) and initial surgery parameters were collected (time from fall to intervention, duration of surgery, intraoperative complications). Radiographic parameters were also analyzed (tip-apex distance and Chang criteria). In all cut-out cases, 5 microbiological cultures and 1 anatomopathological sample were taken and the osteosynthesis material was sent for sonication. Fracture-related infection (FRI) was diagnosed based on Metsemakers et al (2018) and McNally et al (2020) diagnostic criteria. Results. Of the 67 cut-out cases, 16 (23.9%) presented clinical, analytical or microbiological criteria of infection. Of these sixteen patients, only in 3 of them the presence of an underlying infection was suspected preoperatively. A new osteosynthesis was performed in 24 cases (35.8%) and a conversion to arthroplasty in the remaining 43 (64.2%). A comparative analysis was performed between cases with and without infection. The groups were comparable in terms of demographic data and postoperative radiological data (using Chang criteria and tip-apex distance). Patients with underlying infection had a higher rate of surgical wound complication (56.3% vs 22%, p = 0.014), higher rates of leukocytes counts (11.560 vs 7.890, p = 0.023) and time to surgery (5.88 vs 3.88 days, p = 0.072). Conclusions. One out of four osteosynthesis failure in PFF is due to underlying FRI and in almost 20% were not unsuspected before surgery. In PFF osteosynthesis failures, underlying infection should be taken into account as a possible etiological factor and thus a preoperative and intraoperative infection study should be always performed


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 4 - 4
1 May 2016
Lo H
Full Access

Introduction. Osteoporotic intertrochanteric fracture (ITF) is frequent injuries affecting elderly, osteoporotic patients leading to significant morbidity and mortality. Successful prognosis including union and alignment is challenging even though initial successful reduction with internal fixation. Although many factors are related to the patient's final prognosis. Well reduction with stable fracture fixation is still the goal of treatment to improve the quality of life and decrease morbidity in patients with hip fractures, but this in turn depends on the type of fracture and bone quality. Poor bone quality is responsible for common complications, such as failure of fixation, varus collapse and lag screw cut-out, in elderly patients. Kim et al. found that the complication rate when using conventional DHS in unstable ITFs can be as high as 50% because of screw cut-out. We used the dynamic hip screws (DHS) strengthened by calcium phosphate cement (CPC) for treatment femoral intertrochanteric fracture and review the prognosis of our patients. Materials and Methods. From January of 2011 to January of 2014, 42 patients with femoral intertrochanteric fracture underwent surgery with DHS strengthened by CPC. Comparisons were made between the DHS plus CPC group with the other patients with only DHS used in our department. All patients were followed up for an average time of 14.8(6 to 24) months. X-ray was reviewed for the conditions of union and implant failure. Results. In DHS group, fixation failure happened in 3 case, delayed union and coax varus deformity in 2 cases. IN DHS plus CPC group, all fractures healed uneventfully, there is no non-union or malunion in this group. There is only 1 fixation cut-out and 1 secondary lag screw sliding was noted, however, union was still well over fracture site in this case, the patient had no clinical symptoms. Discussion. Residual bony defects present after DHS fixation in intertrochanteric fracture may lead to postoperative complications, including nonunion or implant failure. DHS strengthened by CPC is reliable fixation for old patients with intertrochanteric fracture, We demonstrated that augmentation of the bony defect with dynamic hip screw by reinforced calcium phosphate cement significantly improved the strength of osteoporotic bone, prevent screw loosening, and promote early healing of fracture. The patients can be decreased the risk of refracture and allow early weight bearing, especially in elderly patients with osteoporotic bone


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 35 - 35
1 Mar 2017
Taheriazam A Safdari F
Full Access

Introduction. Failure of intertrochanteric fracture fixation often occurs in patients, who have poor bone quality, severe osteoporosis, or unstable fracture patterns. Hip arthroplasty is a good replacement procedure even though it involves technical issues such as implant removal, bone loss, poor bone quality, trochanteric nonunion and difficulty of surgical exposure. The purpose of this study is to evaluate the outcomes of total hip arthroplasty (THA) as the replacement for failed fixation of intertrochanteric fractures of the femur. Patients and Methods. 203 patients of failed intertrochanteric fractures between April 2009 and October 2014 were included in the study. All of them underwent total hip arthroplasty through direct lateral approach. 150 patients were male (73.8%) and 53 patients (26.1%) were female and the mean of age was 59.02±10.34 years old (range: 56–90 years). The indications of the failure were nail cut out in 174 (85.7%), non-union in 15 (7.3%), plate failure in 14 cases (6.8%). One patient underwent two-stage protocol due to infection. We evaluated the possible clinical and radiological complications and measured functional outcome with modified Harris hip score (MHHS). We used cementless cup in nearly all of patients (95.2%), cementless long stem in 88.1% of patients. Results. We followed patients for the mean time of 4.43±1.11 years (range 3–5 years). The mean (MHHS) was improved from 45.32±12.41 (range 40–49) to 89.37±7.41 (range 85–98) significantly (P=0.002). There was no infection, no reoperation, no dislocation, no nerve palsy, no avascular necrosis, no pulmonary embolism (PTE) and deep vein thrombosis (DVT). There was only one intra-operative fracture which was treated. All patients were ambulatory at the final follow up. There were no significant differences in hospital stay, operating time, and transfusion volume between the 2 groups (P>0.05). Conclusions. We showed in a large population study that functional outcome can be achieved by hip arthroplasty excellently in elderly patients with failed intertrochanteric fractures. Though technically demanding, properly performed hip arthroplasty can be a good replacement option for this patient group


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 150 - 150
1 May 2016
Zhang C Zhang W Li W Huang Z Lin J
Full Access

Objective. Failures of internal fixation after intertrochanteric fractures pose great challenge to orthopaedic surgeons. Hip arthroplasty can be a remedy for such failures, however, the selection of femoral stem length is controversial. This study aims to report our experience of managing failed internal fixation after intertrochanteric fractures with standard femoral stem arthroplasty. Methods. A retrospective review of patients who were managed with hip arthroplasty for failed internal fixation after intertrochanteric fractures in the First Affiliated Hospital of Fujian Medical University, P.R. China between January 2001 to December 2013 was performed. Patients’ age, gender, pre- and postoperative Harris Hip Score (HHS), femoral stem types and surgical outcomes were traced and analyzed. Results. 14 patients were included. The average age at the time of internal fixation and hip arthroplasty was 74.6 years old (Range, 56–89) and 75.8 years old (Range, 58–90), respectively. The time duration between internal fixation and hip arthroplasty ranged from 3 to 26 months. 5 were total hip arthroplasty while 9 were hemiarthroplasty. 4 were implanted with long femoral stems while 10 with standard stems, including 4 cementless (SL-PLUS, Smith & Nephew)and 6 cemented stems. Standard femoral stems were defined as ones that are designed to be used in primary hip replacement, with the length of which ranging from 120 to 140mm. The distal ends of these stems did not exceed the distal screw hole levels of 2 cortical diameters. After a mean follow-up time of 6.4 years (Range, 1–13), 2 patients lost to follow-up and 2 died of non-surgically related diseases. For the 8 cases with standard stems, at the latest follow-up, no periprosthetic fractures or periprosthetic joint infections were observed. A total of 3 hip dislocations happened in 2 patients but were managed successfully with manipulative reduction followed by hip brace. The HHS score increased from an average of 35.6 preoperatively to 79.4 after surgery. Conclusions. Hip arthroplasty can be performed as revision for failed internal fixation after intertrochanteric fractures. Use of standard femoral stems is less invasive, reduces expenditure and can also achieve similar satisfactory clinical outcomes as long femoral stems. However, the long-term clinical outcomes required further follow-up


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 38 - 38
1 Oct 2016
MacLeod R Whitehouse M Gill HS Pegg EC
Full Access

Femoral head collapse due to avascular necrosis (AVN) is a relatively rare occurrence following intertrochanteric fractures; however, with over thirty-thousand intertrochanteric fractures per year in England and Wales alone, and an incidence of up to 1.16%, it is still significant. Often patients are treated with a hip fixation device, such as a sliding hip screw or X-Bolt. This study aimed to investigate the influence of three factors on the likelihood of head collapse: (1) implant type; (2) the size of the femoral head; and (3) the size of the AVN lesion. Finite element (FE) models of an intact femur, and femurs implanted with two common hip fixation designs, the Compression Hip Screw (Smith & Nephew) and the X-Bolt (X-Bolt Orthopaedics), were developed. Experimental validation of the FE models on 4. th. generation Sawbones composite femurs (n=5) found the peak failure loads predicted by the implanted model was accurate to within 14%. Following validation on Sawbones, the material modulus (E) was updated to represent cancellous (E=500MPa) and cortical (E=1GPa) bone, and the influence of implant design, head size, and AVN was examined. Four head sizes were compared: mean male (48.4 mm) and female (42.2 mm) head sizes ± two standard deviations. A conical representation of an AVN lesion with a lower modulus (1MPa) was created, and four different radii were studied. The risk of head collapse was assessed from (1) the critical buckling pressure and (2) the peak failure stress. The likelihood of head collapse was reduced by implantation of either fixation device. Smaller head sizes and greater AVN lesion size increased the risk of femoral head collapse. These results indicate the treatment of intertrochanteric fractures with a hip fixation device does not increase the risk of head collapse; however, patient factors such as small head size and AVN severity significantly increase the risk