Advertisement for orthosearch.org.uk
Results 1 - 20 of 684
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_15 | Pages 22 - 22
7 Aug 2024
Saunders F Parkinson J Aspden R Cootes T Gregory J
Full Access

Background. Lateral lumbar spine statistical shape models (SSM) have been used previously to describe associations with osteoarthritis and back pain. However, associations with factors such as osteoporosis, menopause and parity have not been explored. Methods and Results. A 143-point SSM, describing L1 to the top of L5, was applied to lateral spine iDXA scans from UK Biobank. Associations with self-reported osteoporosis, menopause, parity and back pain and the first 10 modes of variation were examined using adjusted binary logistic regression or linear regression (adjusted for age, height, weight and total spine BMD). We report odds ratios with 95% confidence intervals for each standard deviation change in mode. Complete data were available for 2494 women. Mean age was 61.5 (± 7.4) years. 1369 women reported going through menopause, 96 women self-reported osteoporosis and 339 women reported chronic back pain. 80% of women reported at least 1 live birth. Lumbar spine shape was not associated with back pain in this cohort. Two modes were associated with menopause (modes 1 & 2), 1 mode with parity (mode 1) and 2 modes with osteoporosis (modes 3 & 5). Mode 1 (43.6% total variation), describing lumbar curvature was positively associated with both menopause [OR 1.15 95% CI 1.00–1.33, p=0.05] and parity [OR 1.058 95% CI 1.03–1.0, p=0.01]. Mode 3, describing decreased vertebral height was positively associated with osteoporosis [OR 1.40 95% CI 1.14–1.73, p=0.001]. Conclusion. Menopause and parity were associated with a curvier lumbar spine and osteoporosis with decreased vertebral height. Shape was not associated with back pain. No conflicts of interest.  . Sources of funding. Wellcome Trust collaborative award ref 209233


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 157 - 157
1 Mar 2006
Carlo D Doria C Lisai P Milia F Sassu E Serra M Barca F
Full Access

Purpose: Lumbar interbody fusion cages is a valid technique in the treatment of disc diseases. The aim of this study is to evaluate its validity through the analysis of clinical outcomes and radiological findings.

Materials and methods: The paper reports a serie of 52 posterior lumbar interbody fusion cages operations. Clinical outcomes and radiological results were evaluated at a mean of 5 years post-surgery.

Results: Outcome analysis showed a gradual improvement in symptoms. After surgery, the majority of patients returned to their normal activities. Follow-up plain roentgenograms showed no loss of disc height and no signs of implant’s looseness. Computed Tomography (CT) scans showed the presence of mineralized autologous bone grafts inside the interbody cages.

Conclusions: Expandable interbody cages allow the restoration of the disc space height, giving support to the anterior column, opening the neuroforaminal area and providing increased stability. The interpretation of fusion on the basis of roentgenograms is subjected to arguement. Thin CT scan offers more information than X-rays about the fusion process.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 81 - 81
1 Oct 2022
Hvistendahl MA Bue M Hanberg P Kaspersen AE Schmedes AV Stilling M Høy K
Full Access

Background. Surgical site infection following spine surgery is associated with increased morbidity, mortality and increased cost for the health care system. The reported pooled incidence is 3%. Perioperative antibiotic prophylaxis is a key factor in lowering the risk of acquiring an infection. Previous studies have assessed perioperative cefuroxime concentrations in the anterior column of the cervical spine with an anterior surgical approach. However, the majority of surgeries are performed in the posterior column and often involve the lumbar spine. Accordingly, the objective was to compare the perioperative tissue concentrations of cefuroxime in the anterior and posterior column of the same lumbar vertebra using microdialysis in an experimental porcine model. Method. The lumbar vertebral column was exposed in 8 female pigs. Microdialysis catheters were placed for sampling in the anterior column (vertebral body) and posterior column (posterior arch) within the same vertebra (L5). Cefuroxime (1.5 g) was administered intravenously over 10 min. Microdialysates and plasma samples were continuously obtained over 8 hours. Cefuroxime concentrations were quantified by Ultra High Performance Liquid Chromatography Tandem Mass Spectrometry. Microdialysis is a catheter-based pharmacokinetic tool, that allows dynamic sampling of unbound and pharmacologic active fraction of drugs e.g., cefuroxime. The primary endpoint was the time with cefuroxime above the clinical breakpoint minimal inhibitory concentration (T>MIC) for Staphylococcus aureus of 4 µg/mL as this has been suggested as the best predictor of efficacy for cefuroxime. The secondary endpoint was tissue penetration (AUC. tissue. /AUC. plasma. ). Results. Mean T>MIC 4 µg/mL (95% confidence interval) was 123 min (105–141) in plasma, 97 min (79–115) in the anterior column and 93 min (75–111) in the posterior column. Tissue penetration (95% confidence interval) was incomplete for both the anterior column 0.48 (0.40–0.56) and posterior column 0.40 (0.33–0.48). Conclusions. Open lumbar spine surgery often involves extensive soft tissue dissection, stripping and retraction of the paraspinal muscles which may impair the local blood flow exposing the lumbar vertebra to postoperative infections. A single intravenous administration of 1.5 g cefuroxime resulted in comparable T>MIC between the anterior and posterior column of the lumbar spine. Mean cefuroxime concentrations decreased below the clinical breakpoint MIC for S. aureus of 4 µg/mL after 123 min (plasma), 97 min (anterior column) and 93 min (posterior column). This is shorter than the duration of most lumbar spine surgeries, and therefore alternative dosing regimens should be considered in posterior open lumbar spine surgeries lasting more than 1.5 hours


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 54 - 54
1 Apr 2012
Lakshmanan P Bull D Sher J
Full Access

Generally, it is considered to be safe in preventing iatrogenic instability if half of the facet joint is left intact during decompression surgeries. By removing half of the facets can we get adequate decompression of the nerve roots? Is there a difference at different levels in the lower lumbar spine? What is the inclination of the facet joint at each level and how does it affect the stability?. Retrospective study. We analysed 200 consecutive magnetic reasonance imaging (MRI) scans of the lumbosacral spine at L3/4, L4/5, and L5/S1 levels. We measured the difference in the distance from midline to the lateral border of the foramen and from midline to the middle of the facet joint at each level on either sides. The angle of the facet joint was also noted. The distance to the foramen from the level of the middle of the facet joints seem to be between 5-6mm lateral at every level. The angle of the facet joints at L3/4 is 35.9°+/−7.4°, while at L4/5 it is 43.2°+/−8.0°, and at L5/S1 it is 49.4°+/−10.1°. In lumbar spine decompression surgeries, after the midline decompression extending up to half of the facet joints, a further undercutting of the facet joints to 5-6mm is therefore required to completely decompress the nerve root in the foramen. The more coronal orientation of the facet joint at L5/S1 conforms better stability than that at L3/4level. Therefore, stabilisation of the spine should be considered if more than 2cm of the posterior elements are removed from midline at L3/4 level


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 462 - 462
1 Aug 2008
Govender S Nyati M
Full Access

40% Of the cases of tuberculous (TB) spondylitis involve the lumbar spine. Despite the large forces borne by the lumbar spine and subsequent disability that may result from the TB infection, no studies have reported on the functional outcome. We review the clinical, radiological and patient-orientated functional outcomes using the Oswestry Disability index (ODI) following treatment of lumbar spine TB. The final radiological and ODI assessment was undertaken at follow-up during October 2005 and March 2006 in 37 patients, treated non-operatively for TB of the lumbar spine. The diagnosis was established following a closed needle biopsy. The mean age at follow-up was 35 (range 16 to 76 years). The average duration of symptoms prior to presentation was 9 months (range 2 to 24 months). All patients presented with low backache and night pain but only 42% had constitutional symptoms. 92% had 2-body involvement and L3/4 segment was most commonly involved (35%). The kyphosis measured 13. 0. (range 40. 0. kyphosis to 13. 0. lordosis) and the mean overall lumbar curve was +1. 0. (range 26. 0. kyphosis to 36. 0. lordosis). Ten patients had coronal plane deformity averaging 10. 0. (0. 0. to 22. 0. ). All patients had a minimum of 6 months of anti-TB treatment (6 to 24 months), 76% used spinal brace for a mean of 5 months (2 to 24 months). At the last follow-up the kyphosis was 17. 0. (38. 0. kyphosis to 8. 0. lordosis) with overall average lumbar curve of +3. 0. (18. 0. kyphosis to 36. 0. lordosis). 11 Had mean coronal deformity of 9. 0. (0. 0. to 14. 0. ). 34 Of the patients showed full radiological fusion. The mean ODI was 19% (0 to 55%). We conclude that a favourable functional outcome can be expected with conservative treatment of lumbar spine TB, despite the deformity


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_6 | Pages 19 - 19
1 Feb 2016
Pavlova A Cooper K Meakin J Barr R Aspden R
Full Access

Purpose and Background:. Healthy adults with a curvy (lordotic) lumbar spine were shown to lift a load from the floor by stooping, while straight (flat) spines squatted. Since skin-surface motion capture often misrepresents internal curvature this study calculated internal lumbar curvature during lifting in the same cohort and compared lumbosacral motion. Methods:. Magnetic resonance imaging (MRI) was performed in standing and bending forward to 30, 45 and 60°, with markers on the skin at L1, L3, L5 and S1. Lumbar spine shape was characterised using statistical shape modelling and participants grouped into ‘curvy’ and ‘straight’ spine sub-groups (N=8). On a separate day participants lifted a box (6–15 kg) from the floor without instruction while Vicon cameras tracked sagittal movement of L1, L3 and L5 skin markers. Sacral angle (to horizontal) was calculated from pelvic markers. Matching markers during MRI and lifting sessions allowed vertebral centroid positions (L1, L3, L5, S1) during lifting to be calculated using custom MATLAB code. Results:. The curvy group had more internal lumbar lordosis at pick up despite stooping to lift the load. From upright standing motion occurred earlier at the upper lumbar levels (L1–L3) compared with lower lumbar (L3–L5). During lifting straight spines had greater rigid-body motion of the entire lumbar spine compared with curvy spines who demonstrated more varied intersegmental motion with greater sacral flexion. Conclusion:. Individuals with very lordotic spines retained some degree of internal lordosis despite stooping when lifting. The lumbar spine appears more mobile at the upper levels, L1–L3, and constrained motion was seen in those with the least lordosis


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_6 | Pages 11 - 11
1 Apr 2014
Torrie P Purcell R Morris S Harding I Dolan P Adams M Nelson I Hutchinson J
Full Access

Aim:. To determine if patients with coronal plane deformity in the lumbar spine have a higher grade of lumbar spine subtype compared to controls. Method:. This was a retrospective case/control study based on a review of radiological investigations in 250 patients aged over 40 years who had standing plain film lumbar radiographs with hips present. Measurements of lumbar coronal plane angle, lumbar lordosis, sacral slope, pelvic tilt and pelvic incidence were obtained. “Cases” with degenerative scoliosis (n=125) were defined as patients with a lumbar coronal plane angle of >10°. Lumbar spine subtype was categorised (1–4) using the Roussouly classification. Lumbar spine subtype was dichotomised into low (type 1,2) or high (type 3,4). Prevalence of lumbar spine subtype in cases versus controls was compared using the Chi squared test. Pelvic incidence was compared using an unpaired T-test. Predictors of lumbar coronal plane angle were identified using stepwise multiple regression. Significance was accepted at P<0.05. Results:. The prevalence of type 1–4 lumbar spine subtypes in the case group were 12.8%, 20.8%, 30.4% and 36% respectively and in the control group were 10.4%, 38.3% and 28% and 23.3% respectively. Types 3 and 4 lumbar spine subtypes were more prevalent in the cases group (66.4% vs 51.2% respectively, P=0.0207). Pelvic incidence was not significant different between groups (P=0.0594). No significant predictors of lumbar coronal plane angle were determined. Lumbar spine subtype (P=0.969), pelvic incidence (P=0.740), sacral slope (P=0.203) pelvic tilt (P=0.167) and lumbar lordosis (P=0.088) were not significant. Discussion:. Results show that neither the lumbar spine subtype nor pelvic parameters appear to have a significant influence on determining the coronal plane angle in the degenerative lumbar spine. Conflict Of Interest Statement: No conflict of interest


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_2 | Pages 25 - 25
1 Feb 2015
Pavlova A Eseonu O Jeffrey J Barr R Cooper K Aspden R
Full Access

Purpose and Background. Low birth weight is related to decreased lumbar spine vertebral canal size and bone mineral content later in life, suggesting that antenatal factors affect spine development. The purpose of this study was to explore associations between antenatal factors and lumbar spine morphology in childhood. Methods. Antenatal data and supine MR images of the lumbar spine were available for 161 children. Shape modelling, using principle components analysis, was performed on mid-sagittal images to quantify different modes of variation in lumbar spine shape. Previously collected measures of spine canal dimensions were analysed. Results. Almost 75 % of all of the variation in lumbar spine shape was explained by just three modes. Modes 1 and 3 described the total amount and the distribution of curvature along the spine, respectively. Mode 2 (M2) captured variation in vertebral shape and size; increasing mode scores represented flatter vertebral bodies with increasing anterior-posterior dimensions. We saw no significant associations between mode scores and birth weight z-scores, placental weight, gestation length and no effect of maternal smoking (P>0.05). Controlling for gestation length revealed a positive correlation between birth weight and M2 (P=0.02). Males, longer babies and those from heavier mothers had higher M2 scores (P<0.05). This sex difference remained even when controlling for the other factors (P<0.001). Modes 1 and 2 correlated with spine canal dimensions (P<0.05). Conclusions. Our results suggest that antenatal factors have some effect on vertebral body morphology but not overall lumbar spinal shape. Perhaps environmental factors during growth and genetics play a larger role in determining the overall spine shape. This abstract has not been previously published in whole or substantial part nor has it been presented previously at a national meeting. Conflicts of interest: No conflicts of interest. Sources of funding: This work was supported by a studentship granted to the University and awarded to AVP


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 463 - 463
1 Sep 2009
Sarti-Martínez MÁ Fuster-Ortí MÁ Barrios-Pitarque C
Full Access

Kinematics characteristics of the spine and pelvis are one measure proposed to assess lumbar dysfunction. To extent our knowledge about this matter we described the relationship between the orientation of the sacrum, in the sagittal plane, at upright position and the differential lumbar spine and pelvis range of flexion at the toe touch position in free-pain subjects. Position and motion measurements were recorded by an electrogoniometer. Individuals (n=39), were divided into two groups according to whether they have either pelvis (pelvis -group, n=18) or lumbar spine (spine-group, n=21) dominant movements during flexion. The mean age was 23,67±4,94 years (range18 to 33 years) in the pelvis-group, and 22,55 ± 2,70 years (range 19 to 27 years) in the spine –group. The range of pelvis flexion was significantly greater in the pelvis group than in the spine group, the range of lumbar spine flexion was significantly greater in the spine group than in the pelvis group (α≤.001); however, no differences were found in the range of back flexion (combined lumbar spine and pelvis motion) between the two groups. In the pelvis group the sacrum was significantly more horizontal than in the spine group (α≤.001). In the pelvis-group very strong correlation between sacrum orientation and the maximum range of pelvis flexion was found (r =0, 61). In the Spine group, sacrum orientation showed a negative strong correlation with the maximum range of spine flexion (r= − 0, 71). These results suggest the influence of the individual morphology on the lumbo-pelvic patterns of movements


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 273 - 273
1 Nov 2002
Mann C Parikh M O’Dowd J
Full Access

We compared magnetic resonance imaging (MRI) scans and plain antero-posterior (AP) and lateral radiographs of 100 randomly selected patients in order to detect segmental abnormalities of the lumbar spine. We started by identifying those who appeared to have a segmental defect of the lumbar spine on MRI scan. We then checked all 100 plain radiographs to detect the true rate of segmental abnormality. We detected 17 patients with a segmental abnormality that correlates well with other studies. We believe that MRI scanning alone is not sufficient to detect reliably all segmentation defects in the lumbar spine, and that a plain lateral and an AP x-ray is also required. Of those who do have a segmentation disorder we have identified a sub-group who are at risk of surgery at the wrong level, if the correct pre-operative work-up is not performed. The difficulty will occur when a segmental abnormality is present (as determined by plain radiographs) and it is missed by MRI scan, and plain films are not taken, and the correct level is determined by counting upwards from the lumbosacral take-off angle using the image intensifier in theatre. We believe that all patients undergoing nerve root decompression should have an AP and lateral plain film and an MRI scan as well as pre-operative image intensification in theatre. Although the number of patients that would be affected by this is small, the consequences of operating on the wrong level are well recognised and can be avoided by being aware of the potential problem and by adhering to the above recommendations


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 224 - 224
1 Jul 2014
Emohare O Christensen D Morgan R
Full Access

Summary Statement. Pedicle screws provide robust fixation and rigid immobilization. There has been no attempt to correlate the anatomic dimensions of thoracic and lumbar pedicles with the accuracy of navigated insertion. This study demonstrates that comparable accuracy using this technique. Introduction. Pedicle screws provide robust mechanical fixation, which makes their use attractive; their use enables fixation of the three spinal columns. There remains concern about the potential both for misplacement; various investigators have studied the accuracy of pedicle screw insertions, comparing different techniques. What is not clear, however, is whether there is any relation between the variables of pedicles’ anatomic dimensions, screw dimensions and accuracy. This study aims to elucidate the relationship between these variables. Patients & Methods. We conducted a retrospective review of consecutive pedicle screws that were inserted in the thoracic and lumbar spine at our institution. Screws were inserted using the navigated method (Stealth Station® TREON™, Medtronic, Louisville, CO). The accuracy of the screw insertion was measured using the classification system developed by Gertzbein and Robbins; pedicle dimensions were measured from post-operative computed tomography scans. The corresponding pre-operative scans were then used to measure the pedicle dimensions at the other levels. The magnitude of a cortical breach in the pedicle was represented by a letter: A (no breach), B (<2mm), C (>2mm, <4mm), D (>4mm, <6mm) and E (>6mm). In addition, measurements were made of the anatomic dimensions of the pedicles. The combination of these two measures allowed for direct correlation to be made between the accuracy of screw insertion, screw dimensions and pedicle anatomy. We then computed the proportion of each pedicle (width) occupied by a screw. Results. A total of 765 screws were reviewed, 493 were in the thoracic spine and 272 in the lumbar spine. Of the screws in the thoracic spine, 472 (96%) were either fully in the pedicle or less than 2mm beyond the cortex (within the A+B classification); when considered separately, 323 (66%) were completely within the pedicle (A) and 149 (30%) were less than 2mm beyond the cortex. A total of 21 (4%) screws were beyond 2mm but within 6mm (C+D). In the lumbar spine, 270 (99%) were either completely within the cortex or less than 2mm exposed (classified as A or B). The nadir of pedicle width was at T4. From L1 to L5, measured pedicle width also rose. This pattern was followed, although it was less profound, when screw diameter was measured in the lumbar spine (and even less so in the thoracic vertebrae). The height of pedicles was noted to progressively increase, peaking at the thoraco-lumbar junction. The mid thoracic region was associated with screws occupying the greatest proportion of pedicle diameter. Discussion/Conclusion. The use of pedicle screws in the thoracic and lumbar spine remains relatively safe. The accuracy of navigated insertion was found to compare well to previous series’. Although there is some association between the anatomical dimensions of pedicles and the dimensions of screws, this doesn't seem to be a strong association. Based on the findings in this series, future studies that relate the long term outcome (e.g. failure or screw loosening) with proportion of pedicle diameter taken up by a screw may be warranted


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 148 - 148
1 Mar 2009
Grupp T Yue J Garcia R Cocchi P Schilling C Cristofolini L Blömer W
Full Access

Introduction: Degenerative disc desease is one of the most frequently encountered spinal disorders. The intervertebral disc is a complex anatomic and functional structure, which makes the development of an efficient artificial disc a challenge [. 1. ]. Based on the complexity of the anatomical structures and the nearly unknown loading conditions at the moment only contradictory knowledge exists about the kinematics after TDA and in particular the location of the center of rotation in the human lumbar spine [. 2. ]. The objective of our study was to evaluate the kinematics of the human lumbar spine and the ability of TDA to restore the native conditions in regard to range of motion (ROM), neutral zone (NZ) and center of rotation (COR). Material and Methods: In-vitro flexibility testing on functional spinal units (FSU) out of 12 fresh frozen lumbar spines has been performed. The FSU (L2/L3 and L4/L5) were tested first in the native condition, followed by nucleotomy and partial annulus resection and also after TDA with activ L (lumbar artificial disc, Aesculap Germany). Therefore a spinal simulator has been customized, applying pure moments for flexion/extension, lateral bending and axial rotation (+/−7.5Nm) and axial preload (FP=400N) with a defined velocity (1°/s). The instantaneous COR has been calculated based on the velocity pole method using a 3D ultrasonic motion analysis system, measuring the twelve components of motion. Results: The TDA with activ L leads to a good restoration of ROM and NZ in all loading directions under in-vitro flexibility testing. The instantaneous COR is exemplary described for the native condition under flexion/ extension in the sagittal plane. For the native condition the COR is located in the center of the inferior vertebral endplate. After nucleotomy the COR shifts dorsally into the region of the spinal cord and a significant grade of instability has been measured. After insertion of the lumbar artificial disc the instability can be reduced to the native grade of motion and the COR is located again in the main axis of the spinal column in the upper third of the inferior vertebra. Conclusion: The instantaneous COR has been estimated in-vitro for the different loading situations in the human lumbar spine before and after TDA. Based on the newly introduced method further optimizations of TDA devices can be undergone in regard to the particular aspect of physiological kinematics


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 354 - 355
1 Mar 2004
Mariconda M Lotti G Longo C Ammendolia A Corrado B Milano C
Full Access

Aims: The purpose of this study is to evaluate the possible utility of a low-cost radiation-free technique for predicting degenerative changes in the lumbar spine. Methods: In 117 patients with low back pain or pain in the lower limb, ultrasonographic parameters (speed of sound, broadband ultrasound attenuation, stiffness) of the calcaneus were correlated with (1) evidence for degenerative changes and stenosis on magnetic resonance scans of the lumbar spine and (2) Oswestry Low Back Pain Disability Questionnaire Score. Linear and logistic regression as well as ROC curves analyses were used to evaluate the correlation. Results: Lumbar spine stenosis was associated with elevated calcaneal ultraso-nographic parameters. For the identiþcation of a narrowing of the lumbar spinal canal below 100mm2 of dural sac crosssectional area, speed of sound showed an 89% sensitivity in males older than 60. In these patients, we also found a signiþcant positive correlation between ultrasonographic parameters and scores on a MRI-based degenerative scale. No signiþcant correlation was found between disability score and lumbar spine degeneration or ultrasonographic parameters. Conclusions: Calcaneal ultrasonography is frequently used as a diagnostic test for osteoporosis. Its values are highly correlated with lumbar spine stenosis in elderly symptomatic males, and this low-cost radiation-free diagnostic method can be used to identify those patients needing more extensive diagnostic testing


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 231 - 232
1 Mar 2003
Themistocleous G Stylianessi E Karavolias CE Kaseta M Eustathiou P Sapkas G
Full Access

Purpose: This is a prospective study to examine the post-operative self-satisfaction of the patients and the stability of the lumbar spine. Material and Method: Twenty patients (11 female and 9 male), mean age 40 years old (range 35–58 years) were operated on for: central disc protrusion-sequestration (14 cases), lumbar Stenosis (3 cases) and lumbar instability (3 cases). For the stabilization of the lumbar spine, the Dynesis system (Sulzer-Medica) was applied. In 9 cases a one-motion segment was included in the stabilization, in 8 cases a two-motion and finally in 3 cases a three-motion segment were included. The pre and post-operative examination included a) the self assessment evaluation included the Oswesrty and Roland-Morris questionnaires and b) the radiological parameters related to the type of spinal problem and to the lumbar stability. Results: The mean follow up was 12 months (range 9 to 24 months).There was statistically significant improvement of both the self assessment tests. The radiological examination demonstrated stable lumbar spines and no implant loosening or hardware failure. Conclusion: In spite of the short follow-up the overall results prove that the dynamic stabilization of the lumbar spine with the Dynesis system, in cases of wide laminotomy (ies) for disc excision, and Stenosis as well as for stabilization of depenerative type lumbar instability, is able to provide satisfactory early results


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 58 - 58
1 Nov 2018
Wang X Bian Z Li M Zhu L
Full Access

Aging has been associated with decreases in muscle strength and bone quality. In elderly patients, paravertebral muscle atrophy is accompanied by vertebral osteoporosis. The purpose of this study was to use paravertebral injection of botulinum toxin-A (BTX) to investigate the effects of paravertebral muscle atrophy on lumbar vertebral bone quality. Forty 16-week-old female SD rats were randomly divided into four groups: (1) a control group (CNT); (2) a resection of erector spinae muscles group (RESM); (3) a botulinum toxin-A group (BTX) that was treated with local injection of 5U BTX into the paravertebral muscles bilaterally; and (4) a positive control group (OVX) that underwent bilateral ovariectomy. At 3 months post-surgery the lumbar vertebrae (L3 – L6) were collected. The BMDs of the RESM and BTX groups were significantly lower than that of the CNT group (P < 0.01). Micro-CT scans showed that rats in the three experimental groups had fewer trabeculae and trabecular connections than rats in the CNT group. The bone loss trend of the trabecular networks was most obvious in the OVX rats. Vertebral compression testing revealed that the three experimental groups had significantly lower maximum load, energy absorption, maximum stress, and elastic modulus values than the CNT group (P < 0.01), and these parameters were lowest in the OVX group (P < 0.05). Our results demonstrate that the new paravertebral muscle atrophy model using local BTX injection causes sufficient muscle atrophy and dysfunction to result in local lumbar vertebral bone loss and quality deterioration


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 532 - 532
1 Dec 2013
Sharma A Carr C Cheng J Mahfouz M Komistek R
Full Access

Mathematical modeling provides an efficient and easily reproducible method for the determination of joint forces under in vivo conditions. The need for these new modeling methodologies is needed in the lumbar spine, where an understanding of the loading environment is limited. Few studies using telemetry and pressure sensors have directly measured forces borne by the spine; however, only a very small number of subjects have been studied and experimental conditions were not ideal for giving total forces acting in the spine. As a result, alternative approaches for investigating the lumbar spine across different clinical pathologies are essential. Therefore, the objective of this study was to develop of an inverse dynamic mathematical model for theoretically deriving in-vivo contact forces as well as musculotendon forces in patients having healthy, symptomatic, pathological and post-operative conditions of the lumbar spine. Fluoroscopy and 3D-to-2D image registration were used to obtain kinematic data for patients performing flexion-extension of the lumbar spine. This data served as input into the multi-body, mathematical model. Other inputs included patient-specific bone geometries, recreated from CT, and ground reaction forces. Vertebral bones were represented as rigid bodies, while massless frames symbolized the lower body, torso and abdominal wall (Figure 1). In addition, ligaments were selected and modeled as linear spring elements, along with relevant muscle groups. The muscles were divided into individual fascicles and solved for using a pseudo-inverse algorithm which enabled for decoupling of the derived resultant torques defining the desired kinetic trajectory for the muscles. The largest average contact forces in the model for healthy, symptomatic, pathological, and post-operative lumbar spine conditions occurred at maximum flexion at L4L5 level and were predicted to be 2.47 BW, 2.33 BW, 3.08 BW, and 1.60 BW, respectively. The FE rotation associated with these theoretical force values was 43.0° in healthy, 40.5° in symptomatic, 44.4° in pathological, and 22.8° in post-operative patients. The smallest forces occurred as patients approached the upright, standing position, followed by slight increases in the contact force at full extension. The theoretically derived muscle forces exhibited similar contributory force profiles in the intact spine (healthy, symptomatic, and pathologic); however, surgically implanted spines experienced an increase in the contribution of the external oblique muscles accompanied with decreased slope gradients in the muscle force profiles (Figure 2). These altered force patterns may be associated with the decrease in the predicted contact forces in post-operative patients. In addition, the decreased slope gradients in surgically implanted patients corresponds with the observed difficulty of performing the prescribed motion, possibly due to improper muscle firing, thereby leading to slower motion cycles and less ranges-of-motion. On the contrary, patients having an intact spine performed the activity at a faster speed and to greater ranges-of-motion, which corresponds with the higher contact forces derived in the model. In conclusion, this research study presented the development of a mathematical modeling approach utilizing patient-specific data to generate theoretical in-vivo joint forces. This may serve to help progress the understanding for the kinetic characteristics of the native and surgically implanted lumbar spine


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_4 | Pages 17 - 17
1 Feb 2014
Pavlova AV Meakin JR Cooper K Barr RJ Aspden RM
Full Access

Background and Aim. Low back pain is highly prevalent, particularly in manual occupations. We previously showed that the lumbar spine has an intrinsic shape, identifiable in lying, sitting and standing postures, that affects the spine's response to load. Its effects on motion are unknown. Here we investigate whether intrinsic spinal shape is detectable throughout a greater range of postures and its effect on how healthy adults lift a weighted box. Methods. The lumbar spine was imaged using a positional MRI with participants (n=30) in 6 postures ranging from extension to full flexion. Active shape modelling was used to identify and quantify ‘modes’ of variation in lumbar spine shape. 3D motion capture analysed participants' motion while lifting a box (6–15 kg, self-selected). Results. Two modes accounted for 89.5% of variation in spinal shape, describing the overall curvature (mode 1) and distribution of curvature (mode 2). Within the first 9 modes, scores were significantly correlated between all six postures (r = 0.4−0.97, P<0.05), showing that intrinsic shape was partially maintained throughout. Individuals with straighter spines lifted with greater knee flexion (r = 0.4, P = 0.03) typical of squatting. Knee flexion negatively correlated with lumbar (r = −0.5 to −0.86, P<0.01) and pelvic flexion (r = −0.81, P<0.001). Those with curvier spines flexed significantly more at the back (r = −0.79, P=0.02) typical of stooping. Conclusion. In summary, individuals with straight spines squatted to lift while those with curvy spines stooped, indicating that the way we move to pick up a load is associated with the shape of our spine


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 141 - 141
1 Jul 2002
Bucknill A Coward K Plumpton C Tate S Bountra C Birch R Hughes S Anand P
Full Access

Study Design: To examine the innervation of the lumbar spine from patients with lower back pain, and spinal nerve roots from patients with traumatic brachial plexus injuries. Objectives: To demonstrate the presence of nerve fibres in lumbar spine structures and spinal nerve roots, and determine whether they express the sensory neuronespecific sodium channels SNS/PN3 and NaN/SNS2. Summary of background data: The anatomical and molecular basis of low back pain and sciatica is poorly understood. Previous studies have demonstrated sensory nerves in facet joint capsule and prolapsed intervertebral disc, but not in ligamentum flavum. The voltagegated sodium channels SNS/PN3 and NaN/SNS2 are expressed by sensory neurones which mediate pain, but their presence in the lumbar spine is unknown. Methods: Tissue samples (ligamentum flavum n=32; facet joint capsule n=20; intervertebral disc n=15; spinal roots n=8) were immunostained with specific antibodies to protein gene product (PGP) 9.5, a pan-neuronal marker, SNS/PN3 and NaN/SNS2. Results: PGP 9.5-immunoreactive nerve fibres were detected in 72% of ligamentum flavum and 70% of facet joint capsule but only 20% of intervertebral disc specimens. SNS/PN3-and NaN/SNS2-positive fibres were detected in 28% and 3% of ligamentum flavum and 25% and 15% of facet joint capsule specimens respectively. Numerous SNS/PN3 and NaN/SNS2-positive fibres were found in the acutely injured spinal roots, and some were still present in dorsal roots in the chronic state. Conclusions: SNS/PN3 and NaN/SNS2-immunoreactivity is present in a subset of nerve fibres in lumbar spine structures, including ligamentum flavum and injured spinal roots. This is the first time that sensory nerve fibres have been demonstrated in the ligamentum flavum, and this raises the possibility that, contrary to the conclusions of previous studies, this unique ligament may be capable of nociception. Selective SNS/PN3 and NaN/ SNS2 blocking agents may provide new effective therapy for back pain and sciatica, with fewer side effects. Other novel ion channels are being studied in these tissues


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_I | Pages 17 - 17
1 Jan 2012
Chhikara A McGregor A Rice A Bello F
Full Access

Background. The clinical assessment of Chronic Low Back Pain (CLBP) is usually undertaken at a single time point at clinic rather than through continuous monitoring. To address this, a wearable prototype sensor to monitor motion of the lumbar spine and pelvis has been developed. Sensor Development, Testing and Results. The system devised was based on inertial sensor technology combined with wireless Body Sensor Network (BSN) platform. This was tested on 16 healthy volunteers for ten common movements (including sit to stand, lifting, walking, and stairs) with results validated by optical tracking. Preliminary findings suggest good agreement between the optical tracker and device with mean average orientation error (°) ranging from 0.1 ± 2.3 to 4.2 ± 2.6. The sensor repeatability errors range from 0 to 4° while subject movement variability ranged from 4% to 14%. Parameters of angular motion suggest greater movement of the lumbar spine compared to the pelvis with mean velocities (°/s) for lumbar spine ranging from 15.3 to 74.13 and pelvis ranging from 5.6 to 40.74. Further analysis revealed the extent to which the pelvis was engaged, as a proportion of the total movement. This demonstrated that the pelvis underwent smooth transitions from low (0.02), moderate (0.4) to high (0.99) use during different movement phases. Conclusion. A wearable sensor has been developed to record and quantify lumbar and pelvic movement. This permits an understanding of the lumbo-pelvic relationship to be characterized in an objective way during daily tasks. The next stage of the project will involve testing with CLBP patients


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 442 - 443
1 Nov 2011
Carr C Komistek R Cheng J Mahfouz M Mitchell J
Full Access

Low back pain (LBP) in the region of the lumbar spine is a significant problem among individuals, and efforts focused on treating both the symptoms and causes of LBP have proven to be difficult. Aside from conservative treatments, the predominant surgical approach for treating degenerative spine conditions has been to fuse the vertebral bodies at the symptomatic level. Even today, surgical fusion and its effect on adjacent levels are still not fully understood. Therefore, the objective of this study was to use fluoroscopy and mathematical modeling techniques to identify the in vivo kinematics and kinetics in subjects having either a normal, degenerative or fused condition of the lumbar spine. Twenty-five subjects (ten normal, ten degenerative, and five fusion) were evaluated under fluoroscopic surveillance while performing flexion/extension of the lumbar spine. Subjects within the normal and degenerative groups were analyzed only once, while subjects from the fusion group were analyzed both pre-operatively and at a minimum of six months post-operative. The fusion group consisted of three subjects symptomatic at L4/L5, with the remaining two subjects symptomatic at L5/S1. In vivo kinematics data were derived using a 3D-to-2D model fitting algorithm and served as input into a 3D mathematical model of the lumbar spine. The parametric, inverse dynamics mathematical model was created to allow for the determination of the bearing surface contact and muscle forces at each level of the lumbar spine. Three-dimensional kinematics analyses revealed that subjects classified as having a normal lumbar spine experienced a more uniform motion pattern compared to those observed in the degenerative and fusion groups. Alternatively, the degenerative and fusion subjects demonstrated a more coupled motion pattern in order to perform in plane flexion/extension. Compared to the normal group, rotations in the sagital plane decreased by an average of 28% at the pathological level in the degenerative group, while in the fusion group segmental motions slightly increased at the adjacent levels. Results from the mathematical model also revealed higher out-of-plane forces and increased loading at symptomatic and adjacent levels in both the degenerative and fused groups compared to forces observed in the normal spine. The abnormal motion patterns, which result from decreased or loss of motion at pathological levels in the degenerative and fusion groups, are believed to result in higher resultant forces in the spine. This may be subjecting the intervertebral discs to increased stresses, and as a consequence may be linked to more rapid degeneration at levels where the abnormal kinematics are occurring