Advertisement for orthosearch.org.uk
Results 1 - 20 of 192
Results per page:
Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 393 - 393
1 Jul 2010
Rajkumar S Singer G
Full Access

Introduction: Peri-prosthetic fractures following hip resurfacing arthroplasty are difficult fractures to treat. The surgeon is faced with the task of either attempting to fix the fracture if feasible or revise the resurfacing implant to a conventional total hip replacement. Method & Results: Here we report of a novel way of fixing a peri-prosthetic fracture following resurfacing hip arthroplasty using Polyaxial locking plate fixation. A 53 year old man sustained a intertrochanteric fracture below his resurfacing metal on metal hip prosthesis following a fall. He had his hip resurfaced 3 years back for osteoarthritis in another hospital. He underwent surgery to fix the fracture using a polyaxial locking plate with no post-operative complications. He was mobilised non-weight bearing for the initial six weeks and weight bearing as tolerated thereafter. He went on to union and was moblising without any problems in three months time. His follow-up x-rays at 8 months showed fracture healed with no evidence of prosthesis problems. Discussion: There are various methods of treating a periprosthetic fracture of a well fixed resurfaced hip implant. The two types of management are open reduction and internal fixation and revision to a stemmed hip implant. These fractures can be fixed with cannulated hip screws, blade plate device or plating with screws avoiding the stem of the resurfacing prosthesis. We used the polyaxial locking plate device with good result thereby avoiding the need for revision surgery with its attendant risks. Using this implant is a useful alternative for these fracture patterns


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 79 - 79
11 Apr 2023
Underwood T Mastan S O'Brien S Welton C Woodruff M
Full Access

There has been extensive research into neck of femur fractures in the elderly. Fragility non-hip femoral fractures share many of the same challenges [1]. Surgical management is complex, patients are frail and mortality rates have been reported as high as 38% [2]. Despite this, relatively little data is available evaluating the level of MDT care provided to non-hip femoral fractures. This audit aimed to evaluate the standard of MDT care provided for patients with non-hip femoral fractures according to the NHFD key performance indicators. The following fractures were included in the dataset: distal femoral, femoral shaft and peri-prosthetic femoral. Patients under 65 were excluded. Data was retrospectively collected using post-operative and medical documentation. Performance was assessed according to five key performance indicators:. Did orthogeriatrics review the patient within 72-hours?. Was surgery performed within 36-hours?. Was the patient weight bearing post-operatively?. Was a confusion assessment completed?. Was the patient discharged home?. 38 patients met the inclusion criteria. 84% of patients were seen by orthogeriatrics within 72 hours of admission. 32% of patients were operated on within 36-hours of admission, with time to theatre exceeding 36-hours in 92% of peri-prosthetic fractures. 37% of patients were not advised to full weight bear post operatively. 84% of patients received a confusion assessment whilst 61% of patients were discharged to their prior place of living. Our results suggest that non-hip femoral fractures do not receive the same standard of MDT care as neck of femur fractures. Greater prioritisation of resources should be given to this patient subset so that care is equivalent to hip-fracture patients. Time to surgery is a particular area for improvement, particularly in peri-prosthetic fractures, a trend that is mirrored nationally. Greater emphasis should be placed on encouraging full-weight bearing post-operatively to prevent post-surgical complications


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 22 - 22
1 Apr 2022
Lewis C Baker M Brooke B Metcalf B McWilliams G Sidhom S
Full Access

Constrained acetabular inserts provide a solution for both complex primary and revision hip arthroplasty, but there have been ongoing concerns for high risk of failure and their longevity. The Stryker® Trident acetabular insert is pre-assembled with its constrained ring. We believe this to be the largest series of constrained acetabular inserts with a minimum of 5 year follow-up. We retrospectively reviewed all Stryker® Trident ‘All-Poly’ constrained acetabular inserts cemented into bone in our unit between 2008 and 2016. We collated demographic details and reviewed all patients’ radiographs and clinical notes. Indications for surgery, latest Oxford Hip Scores (OHS) and clinical and radiographic complications were identified. 117 consecutive Stryker® Trident ‘All-Poly’ constrained inserts were cemented into bone in 115 patients during the study period with a mean age of 80 (47–97). Most common indications for surgery were recurrent dislocation (47), complex primary arthroplasty (23), revision arthroplasty (19) and failed hemiarthroplasty (12). 41 patients required revision of the acetabular component only. Follow-up was a minimum of 5 years (mean 8.6, range 5–13). There were three 30-day mortalities and six 1-year mortalities. The mean latest OHS was 37 (24–45). Four cups failed in three patients, one at the cement-bone interface, two at the cement-prosthesis interface and one at the bipolar interface. These were treated conservatively in three patient and with excision arthroplasty in one patient. There were four peri-prosthetic fractures, one Vancouver C distal femur fracture treated conservatively and three Vancouver B1 fractures, two treated conservatively and one treated with open reduction internal fixation. There was breakage of one constrained ring with no adverse effects and one superficial wound infection requiring oral antibiotics only. This series demonstrated that despite the elderly and complex nature of these patients’ clinical situations, constrained acetabular inserts offer a useful and pragmatic solution, with relatively low complications, including in our series a cup failure rate of 3% and peri-prosthetic fracture rate of 3%


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_12 | Pages 11 - 11
1 Oct 2021
Turnbull G Nicholson J Marshall C Macdonald D Breusch S Clement N
Full Access

The Olympia femoral stem is a stainless steel, anatomically shaped, polished and three-dimensionally tapered implant designed for use in cemented total hip arthroplasty (THA). The primary aim of this study was to determine the long-term survivorship, radiographic outcome, and patient reported outcome measures (PROMs) of the Olympia stem. Between May 2003 and December 2005, 239 patients (264 THAs) underwent a THA with an Olympia stem in our institution. PROMs were assessed using the Oxford Hip Score (OHS), EuroQol-5 dimensions (EQ-5D) score and patient satisfaction at mean 10-years following THA. Patient records and radiographs were then reviewed at a mean of 16.5 years (SD 0.7, 15.3 to 17.8) following THA to identify occurrence of complications or revision surgery for any cause. Mean patient age at surgery was 68.0 years (SD 10.9, 31–93 years). There were 156 women (65%, 176 THAs). Osteoarthritis was the indication for THA in 204 patients (85%). Stem survivorship at 10 years was 99.2% (95 % confidence interval [CI], 97.9%-100%) and at 15 years was 97.5% (94.6%–100%). The 15-year stem survival for aseptic loosening was 100%. Only one occurrence of peri-prosthetic fracture was identified, with no episodes of dislocation found. At a mean of 10 (SD 0.8, 8.7 –11.3) years follow-up, mean OHS was 39 (SD 10.3, range 7 – 48) and 94% of patients reported being very satisfied or satisfied. The Olympia stem demonstrated excellent 10-year PROMs, very high rates of stem survivorship and negligible peri-prosthetic fracture and dislocation rate at final follow-up beyond 15 years


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 85 - 85
1 Jul 2022
Rahman A Heath D Mellon S Murray D
Full Access

Abstract. Introduction. In cementless UKR, primary fixation of the tibial component is achieved by press-fitting a keel (i.e. with interference) into a vertical slot cut into the proximal tibia. This may adversely affect the structural integrity of surrounding bone. Early post-operative peri-prosthetic tibial fractures are 7x more common in very small knees, but the aetiology of these fractures is unknown - such sizes are rarely used in the UK but more common in Asian populations. This study explores the effect of keel-related features in fracture risk of these very small tibias. Method. This in vitro study compares the effect of keel and slot depth (standard vs 33% shallower vs nil) and loading position (anterior/posterior gait range limits: mid-tibia vs 8mm posterior) on fracture load and path. 3D-printed titanium components were implanted using surgical instrumentation/technique, in bone-analogue foam machined to a CT-reconstructed very small tibia which subsequently experienced a peri-prosthetic fracture. Results. Introducing a standard slot reduces load-to-fracture by 50% (1421N-vs-710N, p<0.0001). Press-fitting a standard keel further reduces load-to-fracture by 40% (710N-vs-423N, p=0.0001). A shallower slot/keel increases load-to-fracture substantially (slot: 27% increase, 904N-vs-710N p=0.0003, slot+keel: 60% increase, 683N-vs-423N p=0.0004). Deeper keels fractured more vertically (current 8.2° vs shallow 15.5° vs nil 21°, degrees-to-vertical, p<0.0001). There was no difference caused by loading position. Conclusion. In very small tibias, a standard cementless keel significantly weakens the bone and may contribute to fractures. Therefore, decreasing interference or using a shallower keel should decrease the risk of fracture, although it might compromise fixation


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 7 - 7
1 Jul 2016
Lokikere N Saraogi A Sonar U Porter M Kay P Wynn-Jones H Shah N
Full Access

Distal femoral replacement is an operation long considered as salvage operation for neoplastic conditions. Outcomes of this procedure for difficult knee revisions with bone loss of distal femur have been sparsely reported. We present the early results of complex revision knee arthroplasty using distal femoral replacement implant, performed for severe osteolysis and bone loss. Retrospective review of clinic and radiological results of 25 consecutive patients operated at single centre between January 2010 and December 2014. All patients had single type of implant. All data was collected till the latest follow up. Re-revision for any reason was considered as primary end point. Mean age at surgery was 72.2 years (range 51 – 85 years). Average number of previous knee replacements was 2.28 (range 1 to 6). Most common indications were infection, aseptic loosening and peri-prosthetic fracture. Average follow up was 24.5 months (range: 3–63 months). 1 patient died 8 months post-op due to unrelated reasons. Re-revision rate was 2/25 (8%) during this period. One was re-revised for aseptic loosening and one was revised for peri-prosthetic fracture of femur. Two other peri-prosthetic fractures were managed by open reduction and internal fixation. All 3 peri-prosthetic fractures occurred with low energy trauma. It is noteworthy that there was no hinge or mechanical failures of the implant. Peri-prosthetic fracture in 12% of patients in this series is of concern. There are no similar studies to compare this data with. The length of the stem, type of fixation of the stem, weight of the distal femoral component of implant can be postulated as factors contributing to risk of peri-prosthetic fracture


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 31 - 31
2 May 2024
Stedman T Hatfield T McWilliams A
Full Access

Arthroplasty in patients who are intravenous drug abusers presents a complex challenge, frequently requiring intervention at a younger age. The cohort suffer increased complication rates due to significant co-morbidities and poor engagement in medical services, in comparison to other patients undergoing lower limb arthroplasty. Multiple small studies show arthroplasty in this patient cohort is associated with high complication and mortality rates. A search of electronic databases were undertaken with the assistance of the library services from the Rotherham NHS Foundation Trust, including Chocraine, SCOPUS and PubMed. Abstracts were reviewed and relevant studies extracted for full review. Full text articles were reviewed based on strict inclusion and exclusion criteria. Searches identified Two thousand and forty-four papers; twenty-seven studies were identified for full review of the paper based on the inclusion criteria above. From this, nine studies were deemed appropriate to for data extraction. These nine papers present one hundred and thirty-two cases of lower limb arthroplasty, fifty nine Total Knee Arthroplasty and seventy three Total Hip Arthroplasty. From this the authors examined incidences of implant failure due to infection, revision, mortality, dislocation, aseptic loosening, peri-prosthetic fracture, or other causes. Of these, 58% of patients (n = 77) with a history of intravenous drug abuse suffered some form of significant complication; 4% of this cohort (n = 5) were lost to follow up. Infection was reported in 32% of cases and a mortality rate of 4.7%. The rising demand of lower limb arthroplasty for intra-venous drug abusers presents a very real problem for the modern Orthopaedic surgeon. Within the studies examined, more than half report implant failure. This study synthesises the available literature regarding treatment of these patients to help facilitate decision making and informed consent


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 5 - 5
4 Apr 2023
Vicary-Watts R McLauchlan G
Full Access

Cannulated hip screws are frequently used in the management of hip fractures. There have been concerns over the failure rate of the technique and the outcomes of those that subsequently require conversion to total hip replacement (THR). This study utilised a database of over 600 cannulated hip screw (CHS) fixations performed over a 14-year period and followed up for a minimum of one year (1-14). We identified 57 cases where a conversion to THR took place (40 females, 17 males, mean age: 71.2 years). Patient demographics, original mechanism of injury, fracture classification, reason for fixation failure, time until arthroplasty, implant type and post-arthroplasty complications were recorded. Clinical outcomes were measured using the Oxford Hip Score. The failure rate of cannulated screw treatment was 9.4% and the mean time from initial fixation to arthroplasty was 15.4 (16.5) months. Thirty six fractures were initially undisplaced and 21 were displaced. As one might expect the displaced cases tended to be younger but this didn't reach statistical significance [66.5(14.3) vs 72.7(13.1), p=0.1]. The commonest causes of failure were non-union (25 cases, 44%) and avascular necrosis (17 cases, 30%). Complications after THR consisted of one leg length discrepancy and one peri-prosthetic fracture. The mean Oxford score pre-arthroplasty was 12.2 (8.4), improving to 38.4 (11.1) at one-year. Although the pre op Oxford scores tended to be lower in patients with undisplaced fractures and higher ASA scores, the improvement was the same whatever the pre-op situation. The one-year Oxford score and the improvement in score are comparable to those seen in the literature for THR in general. In conclusion, CHS has a high success rate and where salvage arthroplasty is required it can provide good clinical outcomes with low complication rates


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 48 - 48
19 Aug 2024
Falez F Casella F Zaccagno S
Full Access

Post-operative peri-prosthetic femoral fracture (PO-PPFF) is one of the most relevant complications in primary Total Hip Arthroplasty (pTHA), accountable for a significant clinical and socio-economic burden both in revision and fixation settings. We retrospectively reviewed of our series of 1586 cementless total hip arthroplasty performed between 1999 and 2019 (achieving a minimum of 5-years follow-up) with different short stems. We have observed a cumulative low incidence of PO-PPFF of 0,33% (5 cases): we divided Po-PPFF in two groups: fracture occurred around a short stem (A) and around a standard shortened stem (B), according to French Hip & Knee Classification of Short Stems. Despite the length of observed period (mean follow-up 12 years, min 5 years max 24 years) a total of 1512 cases (mean age at surgery 61 years, max 74, min 40 years) were available to clinical and radiographic follow-up, being this population enrolled in elective surgery clinical protocols. Our data exceed the low incidence of post-operative femoral fracture around bone -preserving previously reported by Kim in 2018 (12 fracture out of 1089 cases:1.1%). No correlation have been observed among occurrence of PO-PPF age of the patient and no fracture occurred around cemented short stems despite patient's characteristics were unfavourable in term of age and bone quality. This result is not unexpected, giving the lower incidence of peri-prosthetic fracture even cemented conventional stems, as reported in all registry and systematic reviews. A similar behaviour was reported in 2020 Australian Joint Registry, where Post-operative periprosthetic femoral fracture showed a steep curve in early period, but remaining firmly below 1% during the following 12 years. Our clinical data seems to confirm previous studies by Jones (conducted on synthetic bone and fresh-frozen cadaveric femurs) where higher fracture angles and higher fracture torque were detected in short hips compared to standard stems


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 12 - 12
23 Jun 2023
Yee AHF Chan VWK Chiu K
Full Access

Uncemented femoral components have been used in total hip arthroplasties (THAs) for over three decades. Data on long-term performance of hydroxyapatite-coated femoral stems is however limited. This study reports the survivorship of a collarless, straight, hydroxyapatite-coated femoral stem (Omnifit HA, Osteonic) with a minimum of 20 years of follow-up. We reviewed the results of 165 THAs using Omnifit HA in 138 patients performed between August 1993 and December 1999. The mean age at surgery was 46 years (range 20 – 77 years). Avascular necrosis was the most common cause of THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (range 20–31 years). At 20 and 25 years, 113 arthroplasties (91 patients) and 63 arthroplasties (55 patients) were available for follow-up respectively, while others had deceased or were lost to follow-up. Kaplan-Meier survivorship analysis was performed to evaluate the survival of the femoral component. Radiographs were reviewed at regular intervals, and implant stability was evaluated using Engh classification. Seven out of 165 stems were revised upon the latest follow-up; that included one case of aseptic loosening with revision done at 15 years, three peri-prosthetic fractures, two infections, and one recurrent dislocation. At 20 years, survivorship with revision of the femoral stem for any cause and aseptic loosening as the endpoint was 96.0% (95% CI, 92.6 – 99.5%) and 98.4% (95% CI, 96.2 – 100%) respectively. At 25 years, the corresponding survivorship rates were 94.5% (95% CI, 91.9 – 97.3%) and 98.1% (95% CI, 95.7 – 99.6%) respectively. Radiographic findings of stable bony fixation were seen in 86 stems (76.1%) and those of loosening in 4 stems (3.5%) at 20 years. All patients with radiographic signs of loosening were asymptomatic and did not require revision. The Omnifit HA femoral stem offered promising long-term survivorship into the third decade


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 1 - 1
23 Jun 2023
Parker J Horner M Jones SA
Full Access

Contemporary acetabular reconstruction in major acetabular bone loss often involves the use of porous metal augments, a cup-cage construct or custom implant. The aims of this study were: To determine the reproducibility of a reconstruction algorithm in major acetabular bone loss. To determine the subsequent success of reconstruction performed in terms of re-operation, all-cause revision and Oxford Hip Score (OHS) and to further define the indications for custom implants in major acetabular bone loss. Consecutive series of Paprosky Type III defects treated according to a reconstruction algorithm. IIIA defects were planned to use a superior augment and hemispherical cup. IIIB defects were planned to receive either augment and cup, cup-cage or custom implant. 105 procedures in cohort 100 patients (5 bilateral) with mean age 73 years (42–94). IIIA defects (50 cases) − 72.0% (95%CI 57.6–82.1) required a porous metal augment the remainder treated with a hemispherical cup alone. IIIB defects (55 cases) 71.7% (95%CI 57.6–82.1) required either augments or cup-cage. 20 patients required a hemispherical cup alone and 6 patients received a custom-made implant. Mean follow up of 7.6 years. 6 re-revisions were required (4 PJI, 2 peri-prosthetic fractures & 1 recurrent instability) with overall survivorship of 94.3% (95% CI 97.4–88.1) for all cause revision. Single event dislocations occurred in 3 other patients so overall dislocation rate 3.8%. Mean pre-op OHS 13.8 and mean follow-up OHS 29.8. Custom implants were used in: Mega-defects where AP diameter >80mm, complex discontinuity and massive bone loss in a small pelvis (i.e., unable to perform cup-cage). A reconstruction algorithm can >70% successfully predict revision construct which thereafter is durable with a low risk of re-operation. Jumbo cup utilized <1/3 of cases when morphology allowed. The use of custom implants has been well defined in this series and accounts for <5% of cases


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 112 - 112
10 Feb 2023
Ross M Vince K Hoskins W
Full Access

Constrained implants with intra-medullary fixation are expedient for complex TKA. Constraint is associated with loosening, but can correction of deformity mitigate risk of loosening?. Primary TKA's with a non-linked constrained prosthesis from 2010-2018 were identified. Indications were ligamentous instability or intra-medullary fixation to bypass stress risers. All included fully cemented 30mm stem extensions on tibia and femur. If soft tissue stability was achieved, a posterior stabilized (PS) tibial insert was selected. Pre and post TKA full length radiographs showed. i. hip-knee-ankle angles (HKAA). ii. Kennedy Zone (KZ) where hip to ankle vector crosses knee joint. 77 TKA's in 68 patients, average age 69.3 years (41-89.5) with OA (65%) post-trauma (24.5%) and inflammatory arthropathy (10.5%). Pre-op radiographs (62 knees) showed varus in 37.0%. (HKAA: 4. o. -29. o. ), valgus in 59.6% (HKAA range 8. o. -41. o. ) and 2 knees in neutral. 13 cases deceased within 2 years were excluded. Six with 2 year follow up pending have not been revised. Mean follow-up is 6.1 yrs (2.4-11.9yrs). Long post-op radiographs showed 34 (57.6%) in central KZ (HKKA 180. o. +/- 2. o. ). . Thirteen (22.0%) were in mechanical varus (HKAA 3. o. -15. o. ) and 12 (20.3%) in mechanical valgus: HKAA (171. o. -178. o. ). Three failed with infection; 2 after ORIF and one with BMI>50. The greatest post op varus suffered peri-prosthetic fracture. There was no aseptic loosening or instability. Only full-length radiographs accurately measure alignment and very few similar studies exist. No cases failed by loosening or instability, but PPF followed persistent malalignment. Infection complicated prior ORIF and elevated BMI. This does not endorse indiscriminate use of mechanically constrained knee prostheses. Lower demand patients with complex arthropathy, especially severe deformity, benefit from fully cemented, non-linked constrained prostheses, with intra-medullary fixation. Hinges are not necessarily indicated, and rotational constraint does not lead to loosening


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 33 - 33
7 Jun 2023
Jones S Raj S Magan A
Full Access

Dual mobility (DM) is most often used by surgeons to reduce instability in high risk patients. NJR data on DM has not demonstrated a reduction in all cause revision and has reported an increase in revision for peri-prosthetic fracture (PPF). The aim of our study was:. Report outcome of DM used in high-risk patients including non-revision re-operations (dislocation & PPF). Comparison with conventional bearing THA (cTHA) with local, national and NJR benchmarking data. Retrospective cohort assessment of falls risk for patients receiving DM. Prospective F/U of a DM implant since 2016 and enrolled into Beyond Compliance (BC). Primary outcome measure all-cause revision with secondary outcome including any re-operation and Oxford Hip Score (OHS). All patients were risk stratified and considered high risk for instability. Complications were identified via hospital records, clinical coding linkage, NJR and BC. Benchmarking data for comparison was obtained from same data sources we also considered all B type PPF that occurred with cemented polished taper stem (PTS). 159 implants in 154 patients with a mean age 74.0 years and a maximum F/U of 6.7 years. Survivorship for all-cause revision 99.4% (95% CI 96.2–99.8). One femoral only revision. Mean gain in OHS 27.4. Dislocation rate 0.6% with a single event. Patients with a PTS rate of Type B PPF 2.1% requiring revision/fixation. Compared to cTHA this cohort was significantly older (74.0 vs 68.3 years), more co-morbidity (ASA 3 46.5% vs 14.4%) and more non-OA indications (32.4% vs 8.5%). Relative risks for dislocation 0.57 (95%CI 0.08–4.1) and PPF 1.75 (95%CI 0.54–5.72). Every patient had at least one risk factor for falling and >50% of cohort had 4 or more risk factors using NICE tool. The selective use of DM in high-risk patients can reduce the burden of instability. These individuals are very different to the “average” THA patient. A “perfect storm” is created using a high-risk implant combination (DM & PTS) in high-risk falls risk population. This re-enforces the need to consider all patient and implant factors when deciding bearing selection


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_3 | Pages 11 - 11
23 Jan 2024
Raj S Magan A Jones SA
Full Access

Dual mobility (DM) is an established bearing option in Total Hip Arthroplasty (THA). The traditional mono-block DM designs have limited ability for additional fixation, whereas the modular DM designs allow additional screw fixation but limit internal diameter and have the potential to generate metal debris. We report the early results of a CoCrMo alloy mono-block implant manufactured by additive technology with a highly porous ingrowth surface to enhance primary fixation and osseointegration. Prospective follow-up of the Duplex. TM. implant first inserted in March 2016 enrolled into Beyond Compliance (BC). Primary outcome measure was all-cause revision and secondary outcomes dislocation, peri-prosthetic fracture (PPF) and Oxford Hip Score (OHS). Patients were risk stratified and all considered to be high risk for instability. Complications were identified via hospital records, clinical coding linkage using national database and via BC website. 159 implants in 154 patients with a mean age 74.0 years and a maximum F/U of 7 years. Survivorship for all-cause revision 99.4% (95% CI 96.2–99.8). One femoral only revision. Mean gain in OHS 27.4. Dislocation rate 0.6% with a single event. Patients with a cemented Polished taper stem (PTS) had a Type B PPF rate of 2.1% requiring revision/fixation. Compared to conventional THA this cohort was significantly older (74.0 vs 68.3 years), more co-morbidity (ASA 3 46.5% vs 14.4%) and more non-OA indications (32.4% vs 8.5%). Every patient had at least one risk factor for falling and >50% of cohort had 4 or more risk factors using NICE tool. We believe our results demonstrate that risk stratification successfully aids implant selection to prevent dislocation in high-risk patients. This novel design has provided excellent early results in a challenging cohort where individuals are very different to the “average” THA patient. NJR data on DM has reported an increase in revision for PPF. A “perfect storm” maybe created using DM in high-risk falls risk population. This re-enforces the need to consider all patient and implant factors when deciding bearing selection


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 11 - 11
1 Jan 2018
Saraogi A Lokikere N Siney P Nagai H Purbach B Raut V Kay P
Full Access

Introduction: Revision hip arthroplasty for aseptic loosening of femoral component is successfully treated with impaction bone grafting technique. Owing to easier technique and shorter operative time, distally fixed non-cemented long stems have gained popularity in the present era. However, use of long stems could make subsequent re-revision difficult due to further bone loss. The standard length stem has been often critiqued due to apprehension of peri-prosthetic fracture. This study aims to determine the long-term outcomes of the impaction bone grafting of the femur for aseptic loosening in revision hip arthroplasty using standard length C-stems. 168 total hip revisions of 162 patients with impaction bone grafting and cemented standard C-stem (done with standardized technique) between 1995 and 2008 at a tertiary referral centre were included. Revisions for infection and segmental bone defects were excluded. Mean follow-up of the 168 revision hips was 10.5 years (range 5 – 19.1 years). 14 patients (8.3%) were re-revised, reasons being, persistent deep infection (1.8%), repeated dislocations (1.2%), cup loosening (4.8%) and stem loosening (1.2%). Only 1 patient (0.6%) was re-revised due to stem loosening alone. No peri-prosthetic fractures (intra-operative or post-operative) or stem breakage were identified. Use of standard stem length in hip revisions with impaction bone grafting does not increase the risk of peri-prosthetic fractures, instead, reconstitutes the bone stock. This questions the conventional principle of bypassing the distal cavitation of femur by 2 cortical diameters with the use of long stem. In our experience, a good proximal femur support is key to performance of standard length cemented stems in revision for aseptic loosening irrespective of grade of distal cavitation for cavitatory defects of femur when treated with impaction bone grafting


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 25 - 25
1 Apr 2018
Haidar F Osman A Elkabbani M Tarabichi S
Full Access

Introduction. Early complication post total knee replacement reported to be higher in obese patient in general. Also the outcome of cruciate retaining and PS knee has been fully discussed before and there was no major difference in the outcome. However, the purpose of this paper is to find out if early complication postTKR such as fracture and instability is more common in PS implant than in CR knee. This is a retrospective study comparing two groups of obese patients. The first using PS implant and the other using CR implant. These two groups were matched for age, body mass and severity of deformity. We clearly showed that there is significant increase in peri-prosthetic fracture and instability in the group that use PS implant. Materials & Methods. At our institution we have been using Persona implant which has the option of using PS insert or a CR. The decision to proceed with CR or PS mainly depends on the availability of the implant and also the ability to well balance the knee in patients. In most patients we try to proceed with CR implant. However, the flow of implant sometime sometimes limit us from using CR or the imbalance in the ligament force us to process with PS implant. We have reviewed a chart of over 200 patients in each group of obese patient they were done within the last three years. All cases had a minimum follow up of 6 months. Those groups were matched for body mass, age and severity of deformity. After matching the groups we documented knee score, blood loss, post – operative pain and complications. All surgeries were performed by the same surgeon. Results. We had 7 cases of per-prosthetic fracture in the PS group and non in the CR implant. We had 3 revisions in the PS group for instability and MCL insufficiency. We had non in the CR implant. Infection, wound complication, blood loss, knee score and patient satisfaction were same in both groups. Discussion. Our study clearly show that the decrease incidence of peri-prosthetic fracture in the CR implant which could be easily explained by the fact that a good cortical bone is resected in order to make room for the PS spine. Also, the fact that resecting the posterior cruciate ligament might cause more stress on the implant versus the CR. Instability also were more common in the PS group. We believe this has to do with the fact that the PCL serve as a secondary constraint to the MCL. The presence of the PCL help maintain the stability in case of incidental injury to the MCL during surgery which was reported to be higher in obese patients. Practically the same in both group shows there is no apparent advantage of either implant. Conclusion. There is clear advantage of decreasing the early postoperative complications in obese patient using CR knee and we strongly recommend using CR implant in obese patients in order to reduce the incidence of peri-prosthetic fracture and the revision for instability


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 38 - 38
1 Aug 2013
Baird E Spence S Ayana G
Full Access

Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemented prosthesis should be a final operation. A peri-prosthetic fracture is considered a failure of treatment as the patient then has to undergo an operation with a far greater surgical insult. We looked at all neck of femur fractures over a period of Jan 2007 to June 2010. The number of the peri-prosthetic fractures for uncemented hip hemiarthroplasties was established, and a case note review was carried out. There was 1397 neck of femur fractures. 546 hemiarthroplasties were carried out, of which 183 were cemented, and 363 uncemented. 15 patients (4% of uncemented hemiarthoplasties) had peri-prosthetic fractures. There were no peri-prosthetic fractures in the cemented group, p = 0.004 using Fisher's exact test. The case notes of these patients were analysed. We found there was a common link of significant cardiovascular risk, lack of falls assessment (only 14% of the patients had a completed falls assessment and 21% sustained their fracture during an admission to hospital) and confusion (50% had a degree of dementia that caused significant confusion). Cemented implants should be considered in all patients, especially those who are cognitively impaired or have failed falls assessments; even if the cardiovascular risk is significant. This decision should be made in conjunction with a senior anaesthetist. This is being implemented in our unit and a prospective audit is being carried out over the same time period (July 2010 to Dec 2013) to assess the benefit


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 10 - 10
1 Jul 2016
Saraogi A Lokikere N Siney P Nagai H Purbach B Raut V Kay P
Full Access

The choice of stem length in total hip revision with impaction bone grafting of femur is essentially based upon the grade of cavitation of femur and surgeon's preference. The standard length stem has been often critiqued for the apprehension of peri-prosthetic fracture. Our study highlights the importance of proximal bone stock rather than distal cavitation in determining the length of femoral stem. 168 total hip revisions of 162 patients with impaction bone grafting and cemented standard C-stem (done with standardized technique) between 1995 and 2008 at a tertiary referral centre were included. Revisions for infection and segmental bone defects were excluded. Serial radiographs were retrospectively analysed by two people independently, using Endoklinik classification, Gruen zones and more and outcomes were analysed. Mean follow-up of the 168 revision hips was 10.5 years (range 5 – 19.1 years). 14 patients (8.3%) were re-revised, reasons being, persistent deep infection (1.8%), repeated dislocations (1.2%), cup loosening (4.8%) and stem loosening (1.2%). Only 1 patient (0.6%) was re-revised due to stem loosening alone. No peri-prosthetic fractures or stem breakage were identified. Use of standard stem length in hip revisions with impaction bone grafting doesn't increase the risk of peri-prosthetic fractures even during long term follow up period. This questions the principle of bypassing the distal cavitation of femur by 2 cortical diameters with the use of long stem. In our experience, a good proximal femur support aids in the performance of standard length cemented stems in revision for aseptic loosening irrespective of grade of distal cavitation for cavitory defects of femur treated with impaction bone grafting


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 32 - 32
1 Jun 2016
Sharma V Shamoon R Maheson M Jones SA
Full Access

Introduction. The Corail stem is a fully HA coated tapered implant that has demonstrated long-term success. On the NJR it has become one of the most commonly used implants in the UK. The aim of our study was to document our experience of the revision of this implant together highlighting some important technical considerations. Patients/Materials & Methods. A retrospective review of a consecutive case series of revision procedures where the Corail stem was extracted. We considered time since implantation, collared or uncollared design, indication for revision, Paprosky classification of femoral deficiency, endo-femoral reconstruction or extended approach/osteotomy, subsequent reconstruction either further primary type implant (cemented or cementless) or revision femoral implant. Results. 49 patients required extraction of Corial Stem as part of revision THA. Mean time to extraction 5.2 years (range 1.1 to 10.5 years). Indication for revision in 27 cases ARMD, 7 aseptic loosening, 7 PJI, 6 Peri-prosthetic fractures and 2 instability. The only cases that utilised an extended approach were those performed for peri-prosthetic fracture (5 B2 & 1 Type C fractures) all of which were reconstructed with a Modular Taper Fluted Stem. Of the remaining 43 cases revised for other reasons femoral bone stock was Paprosky Grade 2 in 21 cases, grade 3A in 22 cases. Stems were extracted with implant specific extraction device via endo-feomral route and subsequent reconstruction utilised a primary type femoral implant in 34% of cases. Discussion. All stems, apart from those revised for peri-prosthetic fracture were reconstructed via endo-femoral route. Safe implant extraction is key in this approach and the success of this method in our series emphasizes the major importance of the implant specific extraction instrumentation. Conclusion. As a result of safe implant extraction over 1/3. rd. of patients were able to have a primary implant inserted at the time of revision surgery


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVI | Pages 16 - 16
1 Apr 2012
Rambani R Qamar F Venkatesh R Tsiridis E Giannoudis P
Full Access

With the ever increasing rate of total hip replacement and life span of these patients, there has been an upward trend towards the incidence of peri-prosthetic fractures. Previous studies does suggest the implant cost to as high as 30% of the total reimbursement in primary hip arthroplasty but this figure is much higher in periprosthetic fractures where long stem revisions are commonly used. A prospective comparative study analyzing the total cost of hospital stay for a cohort of 52 consecutive patients with peri-prosthetic fractures of long bones treated in two hospitals from October 2007 to march 2009 was conducted. Demographic data, fracture classification and method of surgical treatment along with the length of hospital stay were recorded in detail. The total cost calculated was then compared to the range of reimbursement price based on HRG (human Resource Group) coding. The implant cost was determined from the buying cost by each institution. 52 patients were available for review. Average age of the patients operated was 78.5 years. 69 percent of the peri-prosthetic fractures in our series were around the proximal femur. The average cost of stay was £ 16453 (£ 1425- 26345). The reimbursement to the hospital ranged from £ 1983 to £ 8735. Hospital source utilization for peri prosthetic fractures is quite high compared to the reimbursement being given to hospitals for treating such patients. This can be as low as £ 1500 as acute phase tariff to £ 9100 for elective revisions and the implant cost can vary from 50% to 200% of the total reimbursement cost. Current recording system for peri-prosthetic fracture is unclear resulting in discrepancy between resource utilization and reimbursement thus resulting in substantial financial losses for hospitals that perform these procedures